HomeMy WebLinkAboutE5-2 - Symbols and Fixture Schedule.pdf
Panelboard; see schedule for details Quadplex Receptacle Duplex Receptacle Communications Outlet (4" SQ Box w/Single Gang Ring) Fire Alarm Speaker/Strobe -Wall Mounted Fire Alarm Strobe
-Wall Mounted Smoke Detector -Duct Mounted Variable Frequency Drive a Single Pole Light Switch; a is switch leg Light Fixtures; see schedule for details F Manual Pull Station Duplex
Receptacle -Emergency Electrical Symbols Lighting Symbols Fire Alarm Symbols Power Symbols Smoke Detector -Ceiling Mounted Plan Note Symbols Electrical Demolition Notes Power Plan Notes
Lighting Plan Notes A AA Combination Starter; see schedule for details CR Card Reader Nonfused Disconnect; see schedule for details Fused Disconnect; see schedule for details T/P Manual
Starter w/Pilot & Thermal Duplex Receptacle; Horizontal Mount Duplex Receptacle, Ground Fault Circuit Interrupt IG Duplex Receptacle, Isolated Ground GFCI Special Receptacle; see drawings
34DKM Three-way Light Switch Four-way Light Switch Dimmer Switch Key Operated Switch Momentary Momentary Switch LV Low Voltage Switch P Single Pole Switch with Pilot Light OS Ceiling
Mounted Occupancy Sensor -Line Voltage OS L Ceiling Mounted Occupancy Sensor -Low Voltage SO Wall Mounted Occupancy Sensor -Line Voltage S Wall Mounted Occupancy Sensor -Low Voltage
O L Fire Alarm Annunciator Panel FACP Fire Alarm Control Panel FAAP Thermal Detector -Duct Mounted Thermal Detector -Ceiling Mounted J Junction Box S Fire Alarm Speaker -Ceiling Mounted
F Motorized Smoke Damper Fire Alarm Bell Flow Detector Tamper Detector M Communication Symbols Communications Outlet Floor Box; see schedule C Ceiling mounted clock C Wall mounted clock
V Volume Control; mount at +48" AFF S Ceiling mounted speaker S Wall mounted speaker Input jack WA Wireless Access Point; mount 6" above ceiling IC M Intercom Station; M indicates Master
Station A Communication Plan Notes Security Symbols ES Door Strike VR Video Recorder VM Video Monitor MM Ceiling mounted motion detector Wall mounted motion detector D Door mounted security
switch REX Request To Exit H Door Hold Open Security camera; see specifications Security camera in enclosure NOT ALL SYMBOLS MAY BE USED Universal Mount Exit Sign -Single Face Universal
Mount Exit Sign -Double Face Nurse Call Symbols B Code Blue; mount at +48" AFF C Sidecom/Aux. jack; mount at +16" AFF E Emergency Pull Station; mount at +24" AFF N Nurse Station Console;
mount at +16" AFF P Patient Bed Station; mount at +48" AFF R Staff Registration Station; mount at +48" AFF D Duty Station; mount at +48" AFF S Staff Assist Station; mount at +48" AFF
Dome Light YELLOW LAMP 2 (EMERGENCY) YELLOW BLU/WHT BLU/WHT RED RED LAMP 1 (EMERGENCY) LAMP 3 BROWN BROWN RED YELLOW YEL/BLK BLU/WHT BLUE BLUE BLUE WHT/BLK WHITE WHITE BLACK COMMON RED
WHT/RED RED/WHT WHITE VIOLET (+) BROWN (-) INVERTER CONNECTOR BUZZER SELECTOR CHARGING INDICATOR (CAP UNUSED LEAD) HOT TEST SWITCH EMERGENCY BALLAST 3-LAMP PROGRAM START BALLAST WALL
SWITCH BLACK 120V ORANGE 277V WARNING: DO NOT CONNECT BROWN CONNECTOR NO SCALE Three(3) Lamp Program Start Ballast GENERAL NOTES -APPLY TO ALL SHEETS: 1. Installations shall conform
with federal, state, and local laws, codes, ordinances, rules, and regulations which are hereby made a part of these contract documents the same as if repeated herein. 2. Contractor
shall include in bid/proposal cost required to completely and properly install work required for the project. 3. Contractor shall include in bid/proposal cost for cutting and patching
as required to install new or existing work, equipment or systems. 4. Clearances indicated are based on best available information. Contractor shall verify piping, ductwork, routing,
and structural details prior to submitting a bid/proposal and include such costs as required to install work as shown and intended. 5. Verify all dimensions from architectural plans.
6. Fluorescent fixtures installed in acoustical tileshall be on one foot module. Fixtures installed in grid ceiling shall be equipped with safety chain (from two corners) connected to
structural member above the the ceiling. 7. Dimensions shown on outlet boxes shall be to the bottom of the box. 8. Conduit to lights is shown to indicate switching and does not indicate
quantity or exact location. 9. Provide plaster rings where required by ceiling construction. 10. Verify location of lights in rooms containing exposed ductwork and piping with mechanical
contractor and relocate as necessary and/or as directed by the engineer. 11. Contractor shall thoroughly examine the work of other contractors prior to submitting a bid/proposal. 12.
Contractor shall coordinate and assure that no piping, ducts, or equipment foreign to electrical equipment shall be installed in, either, or pass through electrical spaces or rooms per
NEC Article 408. 13. All power outages shall be coordinated and scheduled in advance with the owner. 14. Whereas plans generally show individual home run single phase branch circuits,
contractor may run up to three (3) such circuits in a raceway. 15. Verify types of ceiling and dimensions before placing order for light fixtures. 16. Circuit numbers shown for existing
panels are based on existing drawings, schedules, and field survey. Field verify as required. 17. Light fixtures to be reused shall be cleaned and relamped. Ballasts shall be replaced
to match new fixtures. 18. Refer to site plan for additional electrical work. 19. Contract documents consist of both project manual and drawings and both are meant to be complementary.
Anything appearing on either must be executed the same as if shown on both. 20. Some electrical work may be required to be performed off regular work hours. Cost for premium time shall
be included in the bid/proposal. 21. Verify location of all outlets in equipment and built-in furniture with equipment supplier prior to roughing-in. 22. Verify location of all outlets
at counter tops and cabinets with architectural elevation drawings prior to roughing-in. 23. All existing equipment that is to remain is intended to be operational at the completion
of the job. This contractor shall recircuit where necessary to ensure this continued operation. System Furniture and Low Wall Feed Detail TELE/DATA J-BOX WALL TO LOW WALL POWER J-BOX
NO SCALE TO LOW WALL 1-1/4" FLEX CONNECTION 3/4" FLEX CONNECTION SYSTEM FURNITURE LOW WALL OR WALL OR FLOOR BOX Lighting Control Schedule Relay # Circuit Load Control Scheme 1 L-16,18
Site (Pole) Lighting for Security Photocell 2345678 L-15,17 Site (Pole) Lighting for Operation Photocell plus Timer L-13 Site (Bollards) Lighting for Operation Photocell plus Timer EM-18
Facade Lighting & Canopy over ATM Photocell EM-18 Canopy Lighting for Operation Photocell plus Timer L-10 Common Hallway Timer plus Override Switches L-5 Lobby Timer for Normal Operation/Occupancy
Sensor for Off Hours 910 11 12 L-11 Sign Light -South L-13 Sign Light -East L-14 Sign Light -North Photocell plus Timer Photocell plus Timer Photocell plus Timer P1-26 Exhaust Fan Timer
for Normal Operation/Occupancy Sensor for Off Hours Spare COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE The concepts, ideas, designs, plans, and details as shown on this document are
the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall
be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies
for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice
317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION MSKTD 5629 BUILD 65076 CONSTRUCTION SET 3-21-11 3/18/2011 3:17:03 PM 100 W 96th
St Indianapolis, Indiana 46290 E5.22-11-11 Indianapolis North Symbols and Fixture Schedule Lake City Bank LUMINAIRE SCHEDULE Type Fixture Detail Lamp Detail Ballast Detail Mount Description
Basis of Design Alternate 1 Alternate 2 Alternate 3 Count Min. Eff. % Description Qty Wattage Qty Start Type BF Max THD % Min. Start Temp. °F Input Wattage F02 Recess General purpose
specification grade lensed troffer, 2' x 4'. Grid mount. Flush steel door. #12 pattern acrylic lens, .125" thick. 83.8 T8; 24,000HR; 2950 Lumens Initial; 3500°K; 85CRI. 2 32 1 Program
Start 0.88 10 0 56 VA DayBrite SPG Series Columbia ST8 Series Lithonia SP8 Series Metalux GC8 Series 4 F05 Recess Basket Style fixture, 2'x2', Recessed Satine Lens, non air handling.
80 T8; 24,00HR; 1400 Lumens Initial; 3500°K; 85CRI. 3 17 1 Program Start 1.01 10 0 54 VA Pinnacle ADEO AD22A Lithonia Avante Series Metalux Ovation Series Day-Brite Perform Series 113
F05E Recess Basket Style fixture, 2'x2', Recessed Satine Lens, non air handling. Provide emergency battery pack. 80 T8; 24,00HR; 1400 Lumens Initial; 3500°K; 85CRI. 3 17 1 Program Start
1.01 10 0 54 VA Pinnacle ADEO AD22A Lithonia Avante Series Metalux Ovation Series Day-Brite Perform Series 6 F06 Recess Narrow 3" slot T5 fluorescent with concave parobolic louver 62
T5; 25,000HR; 1350 Lumens Initial; 3500°K; 82 CRI. 1 54 1 Program Start 1 10 0 57 VA Focal Point Avenue B Series Day-O-Lite PTP44 Series Pinnacle Edge Series 18 F07 Pendant Shallow decorative
bowl with white opal diffuser lens and spun metal trim ring; swivel canopy; 5/8" metal stem; OAH 41.7in. 72 CFL Long; 4 pin; 2G11 Base; 15,000HR; 2900 Lumens Initial; 3500°K; 82CRI.
6 36 3 Program 0.94 10 0 207 VA Advent AIP8509 Series OCL Horizon HR1 Series 1 F07E Pendant Shallow decorative bowl with white opal diffuser lens and spun metal trim ring; swivel canopy;
5/8" metal stem; OAH 41.7in. Provide Emergency Battery Pack. 72 CFL Long; 4 pin; 2G11 Base; 15,000HR; 2900 Lumens Initial; 3500°K; 82CRI. 6 36 3 Program 0.94 10 0 207 VA Advent AIP8509
Series OCL Horizon HR1 Series 1 F08 Pendant Shallow decorative bowl with white opal diffuser lens and spun metal trim ring; swivel canopy; 5/8" metal stem; OAH 41.7in. 72 CFL Long; 4
pin; 2G11 Base; 15,000HR; 2900 Lumens Initial; 3500°K; 82CRI. 2 36 1 Program 0.94 10 0 69 VA Advent AIP8508 Series OCL Horizon HR1 Series 17 F08E Pendant Shallow decorative bowl with
white opal diffuser lens and spun metal trim ring; swivel canopy; 5/8" metal stem; OAH 41.7in. Provide emergency battery pack. 72 CFL Long; 4 pin; 2G11 Base; 15,000HR; 2900 Lumens Initial;
3500°K; 82CRI. 2 36 1 Program 0.94 10 0 69 VA Advent AIP8508 Series OCL Horizon HR1 Series 2 F09 Wall Direct/indirect wall mount fixture. Brushed aluminum housing. Upper and lower acrylic
diffusers. 50 T8, 24000HR, 1400 Lumens Initial, 3500°K, 85CRI. 2 17 1 Program Start 0.88 10 0 29 VA Metalux BAU Series Lithonia W Series 4 F10 Undercabinet Specification grade, solid
front low profile undercabinet light, 4ft nominal length. Rocker Switch. 68 T8, 24000HR, 2950 Lumens Initial, 3500°K, 85CRI. 1 32 1 Program Start 0.92 10 0 29 VA Day-Brite 8UC Series
Duray DSF Series Fail-Safe MAS Series Lithonia N2S Series 2 F11 Undercabinet Specification grade, solid front low profile undercabinet light, 3ft nominal length. Rocker Switch. 68 T8,
24000HR, 2225 Lumens Initial, 3500°K, 85CRI. 1 25 1 Program Start 0.92 10 0 22 VA Day-Brite 8UC Series Duray DSF Series Fail-Safe MAS Series Lithonia N2S Series 1 K01 Recess 6" Open
Reflector LED Downlight; Haze finish; White painted flange; Dimmable. 1500 Lumens 80 Integral LED; 3500°K; 80CRI. 1 25 1 N/A 1 10 -20 27 VA Portfolio LD615 Omega OM6LED Series Prescolite
LF6LED Series Indy SDG Series 24 K02 Recess 6" Open Reflector LED Wallwash; Haze finish; White painted flange; Dimmable. 1500 Lumens 80 Integral LED; 3500°K; 80CRI. 1 25 1 N/A 1 10 -20
27 VA Portfolio LD615 Omega OM6LED Series Prescolite LF6LED Series Indy SDG Series 12 K03 Recess 6" Open Reflector LED Downlight; Haze finish; White painted flange; Dimmable. 900-1000
Lumens 80 Integral LED; 3500°K; 80CRI. 1 15 1 N/A 1 10 -20 18 VA Portfolio LD610 Omega OM6LED Series Prescolite LF6LED Series Indy SDG Series 35 K03E Recess 6" Open Reflector LED Downlight;
Haze finish; White painted flange; Dimmable. 900-1000 Lumens. Provide emergency battery pack. 80 Integral LED; 3500°K; 80CRI. 1 15 1 N/A 1 10 -20 18 VA Portfolio LD610 Omega OM6LED Series
Prescolite LF6LED Series Indy SDG Series 2 K04 Recess 7" Recessed lens Vertical downlight. LI reflector. 87 70W PAR38 MH Flood 1 70 1 N/A 1 0 -20 80 VA Portfolio MD7X Series Prescolite
LF6MH 7 K05 Wall Die-cast aluminum quarter sphere fixture. Medium throw distribution; multi-volt. Include remote mount emergency ballast. Color to be selected. 25.3 CFL Cluster; 4 pin;
G24q Base; 12,000HR; 1800 Lumens Initial; 3500°K; 82 CRI. 2 26 1 Program Start 1 10 -20 52 VA Lithonia WSQ Series Devine BWD Series Gardco 106 Series McGraw Edison ISS Series 1 K06 Wall
Decorative Die-cast aluminum fixture. Forward throw distribution; multi-volt. Full Cutoff Bronze Color Cutoff Shield 25.3 PSMH; Clear; Vertical; 24,000HR; 14,000 Lumens Initial; 1 150
1 Pulse Start 1 10 -20 180 VA Hubbell Laredo Series Devine BWD Series Gardco 106 Series McGraw Edison ISS Series 1 Not to Scale EM Ballast Wiring Diagram Revisions: Date: By: