Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M2-1 - Mechanical HVAC Floor Plan.pdf
A D F H 23 I J K L 578 10 11 X B E G 46 Y 9 FCU-1 8"ø 14"x12" 10"x12" 18"x12" 18"x12" 12"x12" 14"x12" 18"x12" 18"x14" 24"x14" 12"x12" 12"x12" 18"x14" 18"x12" 18"x14" 24"x12" 10"x12" 12"x12" 8"ø 8"ø 14"x12" 10"x12" 6"ø 8"ø 8"ø 6"ø 8"ø 8"ø 8"ø 8"ø 8"ø 14"x14" 18"x18" 16"x16" 14"x12"10"x12" 8"ø 8"ø 12"x10" 10"x12" 8"ø 8"ø 8"ø 8"ø 8"ø 12"x10" 10"x10" 18"x12" 14"x8" 6"x6" 8"ø 8"ø 10"x12" 8"ø 8"ø 10"x12" 8"ø 8"ø 8"ø 8"ø8"ø 8"ø 8"ø 8"ø 8"ø 8"ø 8"ø 12"x12" SD-2 175 CFM SD-1 125 CFM SD-1 125 CFM SD-1 125 CFM SD-1 125 CFM SD-1 125 CFM SD-2 275 CFM SD-2 150 CFM SD-2 150 CFM SD-2 150 CFM SD-2 200 CFM SD-2 275 CFM SD-2 SD-2 225 CFM 150 CFM SD-1 75 CFM SD-1 150 CFM SD-2 200 CFM SD-2 150 CFM SD-2 150 CFM SD-2 300 CFM SD-2 225 CFM SD-2 225 CFM SD-2 150 CFM SD-2 200 CFM SD-2 200 CFM SD-2 200 CFM SD-2 200 CFM SD-2 225 CFM SD-2 175 CFM SD-2 175 CFM SD-2 150 CFM SD-2 275 CFM SD-1 100 CFM SD-2 200 CFM SD-2 150 CFM SD-2 150 CFM SD-2 150 CFM SD-2 200 CFM SD-2 200 CFM SD-1 50 CFM SD-2 200 CFM SD-2 175 CFM SD-2 175 CFM SD-2 175 CFM CFM SD-2 175 CFM SD-2 250 CFM SD-2 250 CFM UH-1 OFFICE 122 OFFICE 123 OFFICE 124 OFFICE 125 VISITING OFFICE 126 VISITING OFFICE 127 BREAKROOM 133 TELLER WORKROOM 136 TELLER AREA 137 SAFE DEPOSIT JAN. CLOS. 138 135 BANKING LOBBY 139 OFFICE 141 OFFICE 142 OFFICE 143 OFFICE 144 LOBBY 101 VESTIBULE 100 HALLWAY 102 PUBLIC MEETING ROOM 106 WAITING 110 CONFERENCE 112 OFFICE 115 OFFICE 116 OFFICE 117 OFFICE 118 HALLWAY 114 OFFICE 119 OPEN OFFICE 120 WORKROOM 128 HALLWAY 121 HALLWAY 130 MEN 131 WOMEN 132 MEN 105 WOMEN 104 CONFERENCE RM 140 SERVER 129 ELECT 108TABLE/CHAIR STORAGE 109 HALLWAY 107 SG-1 450 CFM SG-1 450 CFM SG-1 450 CFM SG-1 450 CFM EG-2 325 CFM EG-2 300 CFM EG-2 350 CFM EG-2 675 CFM EG-2 300 CFM EG-3 75 CFM EG-3 150 CFM EG-3 225 CFM EG-3 75 CFM EG-2 250 CFM EG-2 1800 CFM EG-2 250 CFM EG-2 500 CFM EG-2 550 CFM EG-2 400 CFM EG-1 75 CFM SD-1 100 CFM SD-1 100 CFM 6"ø 16"x10" 8"x8" 8"x8" 18"x14" 6"ø 6"ø 22"x18" 16"x16" 14"x12" 8"x12" 12"x6" EG-2 800 CFM EG-2 200 CFM T T T T T T T T T T TO RTU-6 TO RTU-7TO RTU-5 TO RTU-1 TO RTU-2 TO RTU-3 TO RTU-3 TO RTU-4 TO RTU-8 TO UH-1 1 11 1 1 1 1 1 2 2 3 3 3 4 4 4 4 4 4 UP TO EF-1 5 5 B.O.D. 11'-4" A.F.F. RETURN AIR OPENING TO PLENUM (TYP.) COVER WITH 1/2" WIRE MESH S S S CO2 CO2 CO2 T MECH 113 RG-1 200 CFM RG-1 175 CFM RG-1 175 CFM RG-1 175 CFM RG-1 175 CFM RG-1 175 CFM RG-1 125 CFM RG-1 125 CFM RG-1 125 CFM RG-1 125 CFM RG-1 125 CFM RG-1 200 CFM RG-1 150 CFM RG-1 150 CFM RG-1 300 CFM 8"ø 8"ø 8"ø 18"x12" 12"x12" 6"ø 6"ø 6"ø 6"ø 6"ø 16"x10" TA TA 12x12 RA SOUND BOOT (TYP.), SEE DETAIL SHEET M5.1 6 PROVIDE TURNING VANES AND DUCTWRAP FOR ACOUSTICAL DAMPENING 6 666 6 7 7 7 7 MICHAEL D. NICHT I ENGINEER REGISTERED 890360 STATE OF I I ND A AN No. PROFESSONAL ER * * COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION MSKTD 5629 BUILD 65076 CONSTRUCTION SET 3-21-11 3/18/2011 4:46:34 PM 100 W 96th St Indianapolis, Indiana 46290 M2.1 2-11-11 Indianapolis North Mechanical HVAC Floor Plan Lake City Bank 1/8" = 1'-0" Mechanical First Floor HVAC Plan M2.1 CONSTRUCTION NOTES 1 ROUTE STEAM FROM HUMIDIFIERS TO DUCT AT THIS LOCATION. SEE SHEET P2.1 FOR ADDITIONAL STEAM PIPING NOTES AND INSTRUCTIONS. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. DELETE DUCT LINER 10' AFTER HUMIDIFIER, REPLACE WITH DUCT WRAP. 2 HUMIDIFIER UNIT LOCATIONS, SEE P2.1 FOR INSTRUCTIONS. HUMIDISTATS SHALL BE LOCATED IN CORRESPONDING RTU RETURN DUCTWORK. 3 GRAVITY RELIEF CAP ON ROOF ABOVE. SEE SHEET M2.2. 4 BASEBOARD ELECTRIC HEATERS BY E.C., SEE ELECTRICAL DRAWINGS. 5 THERMOSTATS SHALL BE AVERAGED BETWEEN THE TWO SPACES SHOWN. 6 DUCT UP TO ROOF, TRANSITION TO 16x16 CONNECTION TO UNIT (SUPPLY AND RETURN). VERIFY WITH EQUIPMENT MANUFACTURER. 7 CENTER DIFFUSER ON WALL BETWEEN COLUMNS. Revisions: Date: By: