Loading...
HomeMy WebLinkAboutT1-1 - Title Sheet.pdf Civil: Jon Sheidler Woolpert Engineering 317.223.2310 Architectural: Ken Etter MSKTD & Associates 260.432.9337 Structural: Jim Schmidt MSKTD & Associates 260.432.9337 Mechanical & Plumbing: Mike Nichter Kirk Wing MSKTD & Associates 260.432.9337 Electrical: Mike Iott MSKTD & Associates 260.432.9337 Interiors: Valerie Lothamer Strahm Group Inc. 260.489.8041 TYPICAL CONTROL JOINT LOCATIONS 20" MAX 20" MAX 20" MAX 20" MAX 1/2 WALL HEIGHT (1/2h) h CL COLUMNS CONTROL JOINT CONTROL JOINT @CHANGES IN WALL HEIGHT CONTROL JOINTS --ONE SIDE @OPENINGS UNDER 6'-0" AND BOTH SIDES @OPENINGS OVER 6'-0" BUILDING CORNER International Building Code, 2006 Project Name: Lake City Bank Indianapolis North Project Location: 100 West 96th Street, Indianapolis, IN 46290 Building Information Proposed Use: Bank Facility Occupancy: B Construction Type: VB Building Area: 11,011 sf Building Height: 1 story Sprinkled: Fully Sprinkled General Building Limitations Max Allowable Area: 9000 sf x 300% (sprinkled area increase) -27,000 sf Max Allowable Stories: 2 stories Fire Ratings: no fire resistance requirements Max Travel Distance: 300' (sprinkled) Plumbing Fixtures: Based on actual or anticipated number of occupants -28 employees W 96th St N Meridian St (US 31) Interstate 69 Allisonville Road N Keystone Ave Interstate 465 North Michigan Road PROJECT LOCATION CARMEL INDIANAPOLIS JAMES R. KRATZ AT ARCHI TECTREGISTERE D 19500182 STATE OF I I ND A AN No. COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION MSKTD 5629 BUILD 65076 CONSTRUCTION SET 3-21-11 3/18/2011 11:49:22 AM 100 W 96th St Indianapolis, Indiana 46290 T1.12-11-11 Indianapolis North Title Sheet Lake City Bank Contacts Drawing Index T1.1 Title Sheet C100 Existing Conditions /Demolition Plan C110 Phase 1 Stormwater Pollution Prevention Plan C111 Phase 2 Stormwater Pollution Prevention Plan C200 Overall Site Plan C201 Site Plan C300 Grading Plan C400 Utility Plan C401 Storm Plan and Profile C402 Electrical Site Plan C500 Landscape Plan C600 Construction Details C601 Construction Details C602 Construction Details C603 Construction Details C604 Construction Details A2.1 Floor Plan A2.2 Roof Plan A3.1 Enlarged Plan, Toilet Accessories Schedule & Details A4.1 Elevations A5.1 Wall Sections A5.2 Wall Sections A5.3 Wall Sections A6.1 Details A6.2 Details A6.3 Details A7.1 Door Schedule & Details A7.2 Exterior Window Elevations A9.1 Reflected Ceiling Plan A10.1 Casework Elevations A10.2 Casework Elevations A11.1 Room Finish Schedule and Plan S1.1 Structural Notes & Typical Details S1.2 Typical Details S2.1 Foundation Plan S3.1 Foundation Sections S4.1 Roof Framing Plans S5.1 Framing Sections S5.2 Framing Sections M2.1 Mechanical HVAC Floor Plan M2.2 Mechanical HVAC Roof Plan M5.1 Mechanical Schedules and Details P2.1 Plumbing Domestic Water, Gas and Fire Floor Plan P2.2 Plumbing Storm, Sanitary and Vent Floor Plan P5.1 Plumbing Schedules and Details P6.1 Plumbing Isometric Diagrams E2.1 First Floor Power Plan E2.2 Roof Electrical Plan E3.1 First Floor Lighting Plan E5.1 Details & Schedules E5.2 Symbols and Fixture Schedule Code Summary Masonry Joint Locations A New Office for Indianapolis North Not to Scale Project Location Map Revisions: Date: By: