HomeMy WebLinkAbout05020051-Heating/Cooling Specs IIOINiIES 8465 Keystone Crossing Suite 145 Indianapolis, Indiana 46240 (317) 254-0336 HALLMARK HALLMARK REGENCY__ & SHOWCASE SERIES STANDARD HEATING A/~D COOLING SPECIFICATIONS The Heating Subcontractor understands that the HVAC System and base price is based upon our All Electric standard house specifications, (including the ~e- ~ignated standard foundation type), which mill include R-35 ceiling insulation. R-13 walls with insulated sheathing, and R-11 four foot drape on the basement walls, air infiltration package and thermally broken windows, The Heating Subcontractor agrees that his base. orice includes an electric furnace and heat pum~ of the specified sizes, all necessary ductwork required for ceil- ings of any and all heights and supply runs to all walk-in closets on outside walls, registers and grilles, (including individual return a~r ducts in the Hallmark Regency and Showcase Series models only), dryer venting, temporary thermostats during winter months, the covering of all duct openings to eli- minate the infiltration of debris during construction, bath fan venting directly to the outside with seperate wall cover or roof louver, furnaces set during rough-in stage as required, non-insulated duct work in all non-conditioned areas including crawl space, damoers On all supply runs, low voltage wiring,' ell required permits, licenses and fees, price'orotection through all selection sheets received by December 31, 1989 and year round, 24 hour, emergency service throughout the warranty pe:idd. Ail work shall be installed per the Heating Subcontractor s layout, in a workman like manner, in strict compliance with any and all applicable codes, rules, regulations and ordinances so a~ to provide and ~ a 75° temperature difference on heating and a 20 temperature difference on cooling for each of the model homes including the balancing of the'system, the insulation of a new furnace filter at the end of the construction ~eriod and a minimum warranty of one (l) year on all parts and labor, five (5) years on the compressor and one (1) year on the furnace. M/! HOMES 8465 Keystone Crossing Suile 145 Indianapolis, Indiana 46240 (317j 254.0336 HALLMARK, HALLMARK REGENCY & ~HOWCASE SERIES SPECIFIC PLUMBING SPECFICATiON~ All soil lines, stacks and vents shall be PVC Plastic with 3" risers to the 2nd floor C.I. 2. Furnish and install plastic laundry box (dryer venting by others). 3. Furnish and install 2" floor drain to sump pump (delete and issue credit if not applicable). 4. Furnish and install 2%" anti-freeze sillcocks. 5. Furnish and install 1 Zoeller #53 Sump Pump (pit by others) with with sump line stubbed 3' beyond foundation (delete and issue credit if not applicable. 6. Provide any and all plumbing work for electric furnace, heat pump and electric water heater. 7. Provide rough-in and prepare for hook-up of 1 icemaker. 8. Furnish and install ~;I radon vent from basement, stub to attic & cap. 9. Furnish and install water heater Yenting to furnace flue installed by others. 10. Install dishwasher hook up only. 11. All backfill, lay tops, dishwasher and dryer vents to be installed by others. FIXTURES 1. Tub-American Standard 5' steel (colored) or equal with Hoen Chateau fixtures and trim. 2. Water Closets-Gerber ~71-212 Elongated Closet Combination Color or equal. 3. Lay Trim-LaV. tops by others with Hoen Chateau fixtures and tram. 4. Kitchen Sink-Elkay CHR-3322 D,C, Stainless Steel Sink with Noen Chateau fixtures, trim and sprayer. 5. Shower Base-36" x 36"(or designated size) molded stone shower base wi and trim. ~91 Whirlat, ay Disposal or equal. ~ter-A.O. S%:ith 52 gallon electric hot water heater. M/IHOMES 8465 Keystone Crossing Suile 145 Indianapolis, Indiana 46240 (31~ 254-0336 HALLMARK HALLMARK REGENCY & SHOWCASE SERIES STANDARD PLUM~ING SP CIFICATIONS GENERAL SPECIFICATIONS~ All required permits, fees, licenses, etc. shall be obtained by the_ Plumbing Contractor and'shall be included in his base bid price. All work shall comply with any and all applicable local, state and national codes, regulations, rules and ordinances. 3. All open ends of. pipes and drains shall be temporarily sealed to prevent infiltration of construction debris. 4. 4" PVC Soil Line shall be stubbed to 3' beyond foundation or connected to sewer line installed by others. 5. All water supply lines shall be copper with 3/4" water line stubbed 3' beyond foundation or connected to water service line installed by others. 6~ All base bid prices shall be based upon the designated standard Ail Electric house.plan (excluding any options and/or extras) including the standard foundation type for each specific plan. 7. The number of fixtures and/or appurtenance may vary according to each standard house plans (e~clu~i. ng option). The Plumbing Subcontractor Wa~rant~.that his base bid price.includes all fixtures and/or appur- tenances'required for a complete job'of plumbing.~or each standard house plan. 8. The Plumbing Subcontractor shall keep the job site clear of all related debris in designated area and broom sweep house as may be required. 9. Base bid prices shall include a minimal 1 year warranty on all work- manship, parts and labor. 8465 KeystOne Crosslng Suite 145 Indianapolis, Indiana 46240 (317) 254.033B ~,. ~D~LLI~ARK P~EGENCY &_ SHO'~CASE SERIES ~~CTRIC) ELECTRICkL %~!RIHG sP£CIFICATIOHS 200 A~..o Service 220V Furnace Ci'rcuit , 220V Air Conditioning Circuit '220V Range Circuit 220V'DrYe c Circuit · ~er Heater Cir'cuit 220V r~a~ 110; ./icing for Su~o pump ll0'! Circuit an, H~sh - 'll0V Circuit for D~sposa! ll0V CirCUit for DishWasher ll0V Circuit for Range Hood . 1 rotection Pa= code [c !es-Per Plh.n Plan .& Code c Plan ' '"" Bath/Fan Light Combination-per Plan ~ ~ixtu=es-~er Plan rewires w~h 3ac;~s for Garage Door Opener es-Per. Plan Recessed 51oh~s (Qith ?ri~ & Lamps)-Per Plan Installation of Ligh~ Ffxtures-Per Plan Oceaings-?er Plan " · I!0V Wiring for end ins~a!la~ion or [ Al! Z!ectricai Permits, Licenses= ~ Fees ? ~lectrica! Subcontractor understands that in some instances, diag,am, . sko~n on various ~odel.clans may b~ incomplete, ~mproparl?being ~/or no= in compliance with local codes as some are currently The Electrical Subcontractor agrees that the ~iring included in his orice will co~O!y with all adp] es and the intent of wiring shown . '. ' with electrical openings (i.e.: )lens and will provide our s and all ot~er devicesi which function correctly end are properly ~h vol:age wiring from the exterior wall to the condensor(including ROUGH FRAMING SPECIFICATIONS_ This document defines both M/I Schottenstein Homes, Inc. and the framing responsibilities in the framing phase of construction. It is that will define M/I Schottenstein Homes, Inc. standard sionalism. The framing subcontractor's work will not be te until all specifications here-in contained are fully met. GENERAL SPECIFICATIONS subcontractor with an accessible backfilled foundation ready to frame on. Provide a complete set of blue prints indicating any options, ectrical power within 150' of foundation. will check with frame carpenter at least once a day to answer questions or interpret prints, and get material shortage list. issued and approved by supervisor. - - Ail options and extras to be invoiced separately zrom standard bid. All labor, t~ols and equipment required to be provided by ~ubcontractor. 11 work to comply with the following framing specifications.' is responsible for protecting materials during the neglect, misuse or Subcontracto correction completion punchout checklist at FRAMING SPECIFICATION~ Check foundation for correct dimensions, square and level. Install all beams level and straight (string side to side and front to rear). Shimming in beam pockets to Stanchion posts to adjustable base down and to flange. done with steel shims. plumb on solid bearing with tightly wrapped around beam .11 sealer will be installed at all locations indicated on attached drawing. 2. Sill plates to be treated material, installed 5/8" inside foundation to allow for insulated sheathing, with foundation straps properly secured. 3. Install joist system per provided layout. 4. All joists to be crowned up with excessive crowns (3/8") thrown out ~2 for blocking. 5. to be toe-nailed into sill plates and beam plate with (3) 8d end and laps nailed, d (properly separate where crossed) with (4) 6. each and kept above bottom of joists. 7. blocking to be installed above all bearing points (beams or walls) except where cantilevered over. 8 nes~ve to be applied at the rate of (1) 32 oz. tube per of subfloor. 9, be glued with both surfaces clean and nailed per nailing ,ne sheet at a time. 10. both T&G and butt, to be glued. Butt joints to be blocked from below. Basement Stairs 1. Maximum rise to be 8-1/4". Minimum effective tread to be 9" (see diagram}. 2 Install treads with (3) 16d nails per side through stringer, 3. Install stairs with (3) 16d nails per side through stringer into floor system. 4. If stairwell has sidewalls, nail stringer into each stud with 7/16" shim between from underside of stairs. 5. Minimum headroom from top of stringer to any obstruction is 6'-8". 6. Check treads for level. 7. s to be hung from floor system with (4) 2X4'S in winter (if no floor). 8. 2] 2x4's per side of basement stairs without sidewalls, one at bottom and one approximately 4 back from handrail mounting. Exterior Walls 1. All exterior walls to be studded 16" O.C. with double top plate (all 2 story houses with walkout basements to be 12 O. · ). 2. Headers tO be size indicated on print or chart, with solid 3. 4. wind bracing installed at corners or t-ply if window or door openings are too close to corner. 5. sight all studs and put bows the same way. 6. Exterior wall corners to be 3 stud as diagram. Window rough openings to be per supervisor's direction. to be installed with cap nails at perimeter 12" O.C. ~tted in field only]. vertical butt Joints to break on studs. All sheathing joints or breaks to be taped. Holes are to be filled and taped. 11. Fireplace openings per detail. ~2. Garage door openings to be correct size, square and per detail. 13. A continuous bead of glue to be applied at all bottom plates to subfloor. Windows_a~d Doors I. Ail windows to be set per manufacturer's instructions, plumb and square with exterior nailing flange taped. 2. All wood windows to have 1/2" inside revealed for drywall. 3. Ali doors to have aluminum flashing underneath. 4. Ail doors to be set plumb, with a 1/2" reveal to inside for drywall, shimmed at 3 places on each side jamb and nailed with 16d galvanized casing nails, and install long screws provided for top hinge. 5. Doors shall be checked for square by checking for even margin between door and jambs along top and sides. 6. On aluminum windows, sills to be set in glue with 1-1/2" projecting into room. Window side of sill to be stuffed with sill sealer before installation. 2. 3. Set trusses per truss layout. All trusses and rafters to be nailed per nailing schedule. Gable ends and trusses to be braced per the manufacturer's instructions. 4. Install lx4 catwalk above ceiling joist full length of roof system. 5. Roof sheathing to be installed with H-clips (1 per each bay). 6. Roof decking to have a 1-1~2" to 2" gap at peak for ridge vent. 7. Truss tails to be aligned and straightened before lx6 subfascia is installed. 8. 2x6 blocking is required between studs at roof lines to allow for installation of ste!~ flashing. 9, Blocking is required between studs at ceilina lines of cathedral and vaulted ceiling for fireblocking. Interior Wall? 1. Ail interior wall studs to be 16" O.C. and stacked over and under floor joists where possible. 2.Sight studs and put bows the same way, 3. Install (3) flat cross blocks between exterior wall studs_ where interior walls intersect (see detail). 4. Install 2x4 flat blocking between trusses every 24" over interior partitions {see detail~. 5.Door headers on non-load bearing walls can 2x4.. 6.Door headers on load bearing walls to be 2x6. 7. Medicine cabinet rough-in to be 14" wide and 18" high. Top of rough-in to be 72" AFF and rough-in to be no closer than 3" from inside corner. 8. Bottom plate of interior walls that run perpendicular to floor joists are to be nailed into joists only. Walls parallel to joist are to be nailed into 2x4 flat blocking under subfloor every 24". Stairs_ 1. Set stairs with treads level. Shim 1/2" each side and nail into every s~dewall stud from underneath treads. Install 2x4 flat blocking on bottom side of all finished stairs at every other tread bay. 1. Ail inside corners at walls and ceilings to be checked for drywall nailers. 2, Install 2x4 blocking for handrails and shower doors. 3. Install 22-1/2"x30" attic access per plan and wrap with 12" plywood rips, 4. locks to be window and out 12" if required, to ~all 2x6 garage /4" block per drawing. kitchen cabinet bulkheads, if required (proper length x14" 85" above subfloor if vinyl, 85-1/2" if tile or wood. door or each window, centered on top window. per drawing. into opening with torsion bar 10. Blocking or plywood rips to be installed at dropped ceilings, bulkheads and stair rake ceilings. 11. All cantilevers and overhangs to be covered with t-ply. 12. All chases to be covered wi~h plywood caps. 13. All cathedral and vaulted ceilings to have fan blocks in center of room. 14. Install garage step. 1. 2. 3. House and basement shall be left broom clean, with' debris removed from crawl. All debris to be placed in one pile in front yard in trash ~asket (located by supervisor). All good material is to be s :d neatly in garage on floor next to outside wall if floor is If floor is not poured, material is to be placed on a rack built on the outside wall. will be expected to make one return trip to house at to complete and perfor~ p~nchout. 1. vanities and tops 2. Ail window and door rough-ins 3. Tub and shower area 4. Vinyl floor areas for squareness and flatness Subcontractor M/I Schottenstein Homes, Inc. Date, Date: 4 ES.¸ Suite 14~ ' HALLMARK, HALLMARK REGE_NCY & SHOWCA_SE SERIES STANDARD_ DRYWALL SPECIFICATIONS The Drywall Subcontractor understands and agrees that his base price for each of the Standard Model Plans includes all labor. ~laterials, insurance, tools, equipment and taxes necessary to complete all drywall stocking, hanging, finishing and ceiling texturing in a prompt, competent and workmanlike manner including the following: I. Ail drywall to be 1/2" regular except as follows: A. Nater resistant (WR) board around all tubs and showers. B. All 2' 0" O.C. Trusses or Rafters to have 5/8" 2. All ceilings to recexve a "Light Daub" texture (E×cep~ garage ceilings in Hallmark Series l-iodels;. 3. All raised, vaulted and/or cathedral ceilings and arches and as shown on standard model plans (Excluding optional and/or extra 4. Ail scraplng and sweeping of floors and hauling away of all related waste and debris from ~ob site. 5.All final touch-up and punch-out work including 1 year warranty inspection and punch-out (Including nail pops, settl~n,g cracks and tape and/or texture defects). Standard garage work shall be as follows: A. Hallmark Series Garages-all common walls and ceilings to De drywalled and fire taped only. B. Hallmark Regency & Showcase Series Gara~es-all walls are to be drywalled, taped and f~nished and all ceilings to be drywalled, taped and textured. Drywall Subcontractor B~': ~ Date