HomeMy WebLinkAboutI5461132.B12211197.pdfB12211197
ProBuild (Mooresville).
My license renewal date for the state of Indiana is July 31, 2012.
Pages or sheets covered by this seal:
Wedgewood Const. 17 Grandin Hall
The truss drawing(s) referenced below have been prepared by DrJ Consulting, LLC under my direct supervision
based on the parameters provided by
The seal on these Truss Design Drawings indicates acceptance of professional engineering responsibility for the design
assumptions as defined on this truss design drawing, solely for the truss component(s) depicted. The design assumptions,
loading conditions, suitability and use of this component for any particular building is the responsibility of the building
designer or owner of the trusses, per ANSI/TPI 1. The responsibilities and duties of the truss designer, truss design
engineer and truss manufacturer shall be in accord with the latest edition of ANSI/TPI 1 Chapter 2 unless otherwise
defined by a contract agreed upon by the parties involved.
Re:
I5461132 thru I5461207
MiTek 20/20 7.2
Important Notice: The accuracy of the Truss Design Drawings relies upon:
1. Accurate metal plate connector design values as published by MiTek.
2. Accurate design values for solid sawn lumber. Design values (E, Emin, Fb, Fc, Fcperp, Ft, and Fv) for solid sawn lumber and approved, grade stamped,
finger jointed lumber shall be as defined by the grade stamp prior to cross cutting and in accordance with the published values of lumber rules writing agencies
approved by the Board of Review of the American Lumber Standards Committee in accordance with the latest edition of ANSI/TPI 1 Section 6.3.
Ryan J. Dexter, P.E.
DrJ Consulting, LLC
6300 Enterprise Lane
Madison, Wisconsin, 53719
May 2,2012
Job
B12211197
Truss
CG01
Truss Type
Diagonal Hip Girder
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461132
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:28 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-iY1NFCJRhAAFNOiC6AaM5gKJ36kejLoLJNqVDizKZcj
Scale = 1:19.9
T1
B1
HW1
1
2
5
6
3
7 8
3x4 4
3x8
4-9-1
4-9-1
-1-9-10
1-9-10
4-9-1
4-9-1
0-10-14
3-6-8
3-6-4
2-11-2
6.66 12
Plate Offsets (X,Y): [2:0-0-0,0-1-1], [2:0-2-1,0-4-6]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
Job
B12211197
Truss
CG02
Truss Type
Diagonal Hip Girder
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461133
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:28 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-iY1NFCJRhAAFNOiC6AaM5gKJ36kejLoLJNqVDizKZcj
Scale = 1:19.9
T1
B1
HW1
1
2
5
6
3
7 8
3x4 4
3x8
4-9-1
4-9-1
-1-9-10
1-9-10
4-9-1
4-9-1
0-10-14
3-6-8
3-6-4
2-11-2
6.66 12
Plate Offsets (X,Y): [2:0-0-0,0-1-1], [2:0-2-1,0-4-6]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
Job
B12211197
Truss
CG03
Truss Type
Diagonal Hip Girder
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461134
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:28 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-iY1NFCJRhAAFNOiC6AaM5gKI56jejLoLJNqVDizKZcj
Scale = 1:23.5
T1
B1
HW1
1
2
5
3
6
3x4 4
3x8
5-11-8
5-11-8
-1-9-10
1-9-10
5-11-8
5-11-8
0-10-14
4-2-8
4-2-4
3-7-2
6.66 12
Plate Offsets (X,Y): [2:0-0-0,0-1-1], [2:0-2-1,0-4-6]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
Job
B12211197
Truss
GE01
Truss Type
GABLE
Qty
2
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461135
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:29 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-AkblSYK3SUI6?YHOft6bdutUlV4ESlcUY1Z2m8zKZci
Scale = 1:39.1
W1
T1 T1
W1
B1
ST4
ST3
ST2
ST1
ST3
ST2
ST1
1
2
3
4
5
6
7
8
9
10
11
20 19 18 17 16 15 14 13 12
3x8
4x6
3x8
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
11-11-0
11-11-0
-1-0-0
1-0-0
5-11-8
5-11-8
Job
B12211197
Truss
GE02
Truss Type
Special Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461136
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:31 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-77jVtEMKz5YpEsQnnI83iJyiGJeXwZln?L29q1zKZcg
Scale = 1:72.3
T2
T3
T4
B1
W1
W2
W3
W4
W5
W4
W5
W4
W6 W7
HW1
W9
W8
ST20
ST21
ST18
ST19
ST17
ST15
ST16
ST13
ST14
ST11
ST12
ST9
ST10
ST7
ST8
ST6
ST5
ST3
ST4
ST2
ST1
ST22
ST23
ST24
ST25
ST26 ST27
T1 ST28
B2 B3
Job
B12211197
Truss
GE03
Truss Type
GABLE
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461137
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:32 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-bJGu5ZMykPggs??zL?fIFWVzJj5df6OwE?ojMTzKZcf
Scale = 1:56.8
W1
T1 T2
W1
B1
ST7
ST6
ST5
ST4
ST3
ST2
ST1
ST6
ST5
ST4
ST3
ST2
ST1
B2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
3x8
4x6
3x8
3x6
18-4-0
18-4-0
-1-0-0
1-0-0
9-2-0
Job
B12211197
Truss
GE04
Truss Type
Special Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461138
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:32 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-bJGu5ZMykPggs??zL?fIFWVrfjygf?XwE?ojMTzKZcf
Scale = 1:67.1
T1
T2
T3
T4
B1
W3
W4
W5 W6
W7
W6
W7
W6
W1
W2
W9
W8
ST19
ST20
ST17
ST18
ST14 ST16
ST15
ST12
ST13
ST10
ST11
ST8
ST9
ST7
ST5
ST6
ST4
ST2 ST3
ST1
ST21
ST22
B2 B3
1
2
3
4 5 6
7
15 14 13
12 11
Job
B12211197
Truss
GE05
Truss Type
GABLE
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461139
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:33 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-3WqGIvNaVioXU9aAujAXnk29e7SBOZb4TfXGvwzKZce
Scale = 1:42.8
W1
T1
T2
W1
B1
ST5
ST4
ST3
ST2
ST1
ST4
ST3
ST2
ST1
1
2
3
4
5
6
7
8
9
10
11
12
23 22 21 20 19 18 17 16 15 14 13
3x8
4x6
3x8
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
Job
B12211197
Truss
GE06
Truss Type
Common Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461140
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:33:14 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-cxRSVSbxjkXC5hoaJQUDN1jNQqtoZBuxhtV6yZzKZb3
Scale = 1:75.0
T2
T2
B1
W2
W1
W2
HW1 W1
HW1
ST5
ST3
ST4
ST2
ST1
ST3
ST4
ST2
ST1
T1
T1
B2
1
2
3
4
5
6
7
8
9
10
11
17 16
15 14 13 12
4x6
3x4
4x10
4x6
4x6
3x6
3x4
1.5x4
3x4
1.5x4
4x10
Job
B12211197
Truss
GE07
Truss Type
GABLE
Qty
2
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461141
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:34 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-XiOeWFOCG0wO5J9MSQhmKxaIGWmb73KDhJHpRMzKZcd
Scale = 1:22.7
T1
W1
B1
ST5
ST4
ST3
ST2
ST1
1
2
3
4
5
6
7
8
14 13 12 11 10 9
1.5x4
3x4 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
12-2-4
12-2-4
-1-6-6
1-6-6
12-2-4
12-2-4
0-3-14
3-7-8
3.25 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
Job
B12211197
Truss
GE08
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461142
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:34 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-XiOeWFOCG0wO5J9MSQhmKxaKxWoW73IDhJHpRMzKZcd
Scale = 1:11.8
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
2-11-1
2-11-1
2-11-1
2-11-1
1-11-6
8.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.07
0.04
0.00
DEFL
Vert(LL)
Job
B12211197
Truss
GR01
Truss Type
Common Truss
Qty
1
Ply
2
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461143
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:35 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-?uy0jbPq1K2FjTkY08C?t97T7w2ssQ3Mwz0NzozKZcc
Scale = 1:77.7
T2
T3
T2
B1
W1 W2
W3 W4
W5 W6
W5 W6
W5
W4
W3
W2
W1
ST17
ST18
ST15
ST16
ST13
ST14
ST11
ST12
ST10
ST8
ST9
ST6
ST7
ST5
ST3
ST4
ST2
ST1
ST19
ST20
ST21
ST22
ST23
ST24
ST25
ST26
ST27
ST28
T1 T1
1 B2 B1
2
Job
B12211197
Truss
GR01
Truss Type
Common Truss
Qty
1
Ply
2
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461143
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:36 2012 Page 2
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-T5WOwxPSodA6LdJlarkEPMgetKN5btJW9dmwVEzKZcb
NOTES
14) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 172 lb down and 92 lb up at 4-6-12, 119 lb down and 80 lb up at 6-6-12, 119 lb
down and 80 lb up at
8-6-12, 119 lb down and 80 lb up at 10-6-12, 119 lb down and 80 lb up at 12-6-12, 119 lb down and 80 lb up at 14-6-12, 119 lb down and 80 lb up at 16-6-12, 119 lb down and 80 lb up at
18-6-12, 119 lb
down and 80 lb up at 20-6-12, 119 lb down and 80 lb up at 22-0-4, 119 lb down and 80 lb up at 24-0-4, 119 lb down and 80 lb up at 26-0-4, 119 lb down and 80 lb up at 28-0-4, 119 lb down
and 80 lb up at
30-0-4, 119 lb down and 80 lb up at 32-0-4, 119 lb down and 80 lb up at 34-0-4, and 119 lb down and 80 lb up at 36-0-4, and 172 lb down and 92 lb up at 38-0-4 on bottom chord. The design/selection
of
such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-6=-60, 6-8=-60, 8-13=-60, 2-12=-20
Concentrated Loads (lb)
Vert: 19=-119 17=-119 73=-172(F) 74=-119 75=-119 76=-119 77=-119 78=-119 79=-119 80=-119 81=-119 82=-119 83=-119 84=-119 85=-119 86=-119 87=-119 88=-172(F)
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
Job
B12211197
Truss
GR02
Truss Type
Half Hip Truss
Qty
2
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461144
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:36 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-T5WOwxPSodA6LdJlarkEPMggfKTxbz5W9dmwVEzKZcb
Scale = 1:19.6
T1
T2
W2
B1
W2 W3
W1
1
2
3 4
7
6 5
1.5x4
4x6
3x8
2x4
4x8
2-8-0
2-8-0
4-0-0
1-4-0
-1-0-0
1-0-0
2-8-0
2-8-0
4-0-0
1-4-0
0-10-14
3-6-14
12.00 12
Plate Offsets (X,Y): [3:0-6-8,0-2-0], [7:0-5-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
Job
B12211197
Truss
GR03
Truss Type
Common Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461145
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:36 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-T5WOwxPSodA6LdJlarkEPMgduKQ2bsoW9dmwVEzKZcb
Scale = 1:65.8
T2
T3
T4
B1
W1 W2
W3
W4
W5
W3
W6
W7
HW1
W9
W8
ST6
ST7
ST5
ST2 ST4
ST1 ST3
ST8
ST9
ST10
ST11 ST12
ST13
T1
B2
1
2
3
4
5 6
7
8
16 15
14 13 12 11 10 9
3x6
4x8 4x8
4x6
5x8 4x6
4x6 4x6
3x6
2x4
3x4
3x4 3x4
Job
B12211197
Truss
GR04
Truss Type
COMMON TRUSS
Qty
1
Ply
3
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461146
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:37 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-xH4n8HQ4ZxJzynux7YFTyaCmtkjHKDlfNHVU2hzKZca
Scale = 1:62.2
T1
T2
T3
B1
W1 W2
W3
W4 W5
W6 W7
B2
HW2
1
2
3 4
5
6
12
11
10 9 8
13 14 16 15 17 18 19 20 21 7 22
5x8
4x6 4x8
5x12
6x6
6x8 6x6
5x12
3x12 5x8
5x6
3x6
3x6
5-5-5
5-5-5
11-9-4
6-3-15
15-2-14
3-5-10
20-1-7
4-10-9
25-3-8
5-2-1
5-5-5
5-5-5
10-7-2
5-1-13
15-2-14
Job
B12211197
Truss
GR04
Truss Type
COMMON TRUSS
Qty
1
Ply
3
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461146
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:37 2012 Page 2
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-xH4n8HQ4ZxJzynux7YFTyaCmtkjHKDlfNHVU2hzKZca
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: 10=-432(B) 8=-432(B) 7=-432(B) 13=-1674(B) 14=-1674(B) 15=-1674(B) 16=-1671(B) 17=-1671(B) 18=-1671(B) 19=-432(B) 20=-432(B) 21=-432(B) 22=-432(B)
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
Job
B12211197
Truss
GR05
Truss Type
Common Truss
Qty
1
Ply
2
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461147
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:37 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-xH4n8HQ4ZxJzynux7YFTyaCiCkjgKEffNHVU2hzKZca
Scale = 1:58.2
T1
T1
B1
W3
W2 W1
W1 W2
HW1 HW1
B2
1
2
3
4
5
9 8
10 11 12 7 13 14 6 15 16
4x6
6x8 10x10
4x8
3x12
4x8
3x12
10x10 10x10
4-8-12
4-8-12
9-2-0
4-5-4
13-7-4
4-5-4
18-4-0
4-8-12
4-8-12
4-8-12
9-2-0
4-5-4
13-7-4
4-5-4
18-4-0
4-8-12
0-10-14
10-0-14
0-10-14
12.00 12
Plate Offsets (X,Y): [1:0-1-4,0-3-0], [5:0-1-4,0-3-0]
LOADING (psf)
Job
B12211197
Truss
GR06
Truss Type
Special Truss
Qty
1
Ply
2
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461148
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:38 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-PTe9LdRjKFRqawT7hGmiUnl_c81j3iApcxF1a7zKZcZ
Scale = 1:74.7
T1
T2
T3
B1
W3 W4
W5 W6
W7
W8
W9 W10
W11
W12
W13
W14
W1 W15
W2
ST11
ST12
ST9
ST10
ST8
ST6
ST7
ST5
ST3
ST4
ST1
ST2
ST13
ST14
ST15
ST16
ST17
ST18
ST19
ST20
ST21
ST22 ST23
T4
B2 B3
1
2
3
4
5
Job
B12211197
Truss
GR06
Truss Type
Special Truss
Qty
1
Ply
2
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461148
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:39 2012 Page 2
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-ugCXZzSL5YZhC42JFzHx1?I9MXNyo9Qyrb_a6ZzKZcY
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-5=-60, 5-11=-60, 10-21=-20
Concentrated Loads (lb)
Vert: 21=-201 14=-201 57=-201 58=-201 59=-201 60=-201 61=-201 62=-201 63=-201 64=-201 65=-201 66=-201 67=-201 68=-201 69=-201 70=-366(B)
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
Job
B12211197
Truss
GR07
Truss Type
Common Truss
Qty
1
Ply
2
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461149
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:39 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-ugCXZzSL5YZhC42JFzHx1?I4CXOyo8ayrb_a6ZzKZcY
Scale = 1:40.5
T1
T2
B1
W2
W1
W2
W1
HW1 HW2
1
2
3
4
5
6
8 9 7 10 11
4x10
5x8 12x12 5x8
1.5x4
12x12
1.5x4
4-3-8
4-3-8
8-3-8
4-0-0
12-7-0
4-3-8
-1-0-0
1-0-0
3-3-8
3-3-8
6-3-8
3-0-0
9-3-8
3-0-0
12-7-0
3-3-8
0-10-14
7-2-6
0-10-14
12.00 12
Plate Offsets (X,Y): [2:0-2-2,0-2-0], [6:0-2-2,0-2-0]
LOADING (psf)
TCLL
TCDL
Job
B12211197
Truss
GR08
Truss Type
Half Hip Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461150
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:39 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-ugCXZzSL5YZhC42JFzHx1?IAEXUkoJbyrb_a6ZzKZcY
Scale = 1:24.6
T1
T2
W2
B1
W2 W3
W1
1
2
3 4
7
6 5
8
9
1.5x4
4x6
3x8
2x4
4x8
3-4-0
3-4-0
6-0-0
2-8-0
-1-0-0
1-0-0
3-4-0
3-4-0
6-0-0
2-8-0
0-10-14
4-2-14
12.00 12
Plate Offsets (X,Y): [3:0-6-8,0-2-0], [7:0-5-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Job
B12211197
Truss
J01
Truss Type
Jack-Open Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461151
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:39 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-ugCXZzSL5YZhC42JFzHx1?IBaXVtoKXyrb_a6ZzKZcY
Scale = 1:13.5
W1
T1
B1
1
2
4
6
3
1.5x4 5
2x4
1-4-2
1-4-2
-1-0-0
1-0-0
1-4-2
1-4-2
0-10-14
2-3-0
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.07
Job
B12211197
Truss
J02
Truss Type
Jack-Open Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461152
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:39 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-ugCXZzSL5YZhC42JFzHx1?IBaXVtoKXyrb_a6ZzKZcY
Scale = 1:13.5
W1
T1
B1
1
2
4
6
3
1.5x4 5
2x4
1-4-2
1-4-2
-1-0-0
1-0-0
1-4-2
1-4-2
0-10-14
2-3-0
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.07
Job
B12211197
Truss
J03
Truss Type
Jack-Open Truss
Qty
2
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461153
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:40 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-MslvmJTzsshYpEcWphoAaCqMvxqKXnn64Fk8e0zKZcX
Scale = 1:16.6
T1
B1
HW1
1
2
4
5
3
6
3x8
3-5-0
3-5-0
3-6-14
0-1-14
-1-0-0
1-0-0
3-6-14
3-6-14
0-6-14
2-11-8
2-10-12
2-5-8
8.00 12
Plate Offsets (X,Y): [2:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
Job
B12211197
Truss
J04
Truss Type
Jack-Open Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461154
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:40 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-MslvmJTzsshYpEcWphoAaCqMvxqKXnn64Fk8e0zKZcX
Scale = 1:16.6
T1
B1
HW1
1
2
4
5
3
6
3x8
3-5-0
3-5-0
3-6-14
0-1-14
-1-0-0
1-0-0
3-6-14
3-6-14
0-6-14
2-11-8
2-10-12
2-5-8
8.00 12
Plate Offsets (X,Y): [2:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
Job
B12211197
Truss
J05
Truss Type
Jack-Open Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461155
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:40 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-MslvmJTzsshYpEcWphoAaCqMKxrsXnn64Fk8e0zKZcX
Scale = 1:16.6
W1
T1
B1
1
2
5
3
4
1.5x4
3x4
2-0-2
2-0-2
-1-0-0
1-0-0
2-0-2
2-0-2
0-10-14
2-11-0
2-10-8
2-4-0
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
Job
B12211197
Truss
J06
Truss Type
Jack-Open Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461156
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:40 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-MslvmJTzsshYpEcWphoAaCqJixoLXnn64Fk8e0zKZcX
Scale = 1:22.5
T1
B1
HW1
1
2
3
3x8 4
5-6-0
5-6-0
-1-0-0
1-0-0
5-6-0
5-6-0
0-6-14
4-2-14
3-9-11
8.00 12
Plate Offsets (X,Y): [2:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.30
0.21
Job
B12211197
Truss
M01
Truss Type
Monopitch Truss
Qty
16
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461157
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:40 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-MslvmJTzsshYpEcWphoAaCqLRxqBXnn64Fk8e0zKZcX
Scale = 1:26.0
T1
W2
B1
W1
1
2
3
5
4
2x4
2x4
2x4
2x4
4-0-0
4-0-0
-1-0-0
1-0-0
4-0-0
4-0-0
0-10-14
4-10-14
4-7-6
0-3-8
12.00 12
Plate Offsets (X,Y): [4:0-2-0,0-0-6]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
Job
B12211197
Truss
M02
Truss Type
Monopitch Truss
Qty
6
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461158
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:40 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-MslvmJTzsshYpEcWphoAaCqMPxqLXnn64Fk8e0zKZcX
Scale = 1:14.4
T1
W1
B1
HW1
1
2
3
4
1.5x4
3x8
1.5x4
2-10-4
2-10-4
-1-0-0
1-0-0
2-10-4
2-10-4
0-6-14
2-5-11
2-2-3
0-3-8
8.00 12
Plate Offsets (X,Y): [2:0-3-8,Edge], [4:0-2-0,0-0-6]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
Job
B12211197
Truss
M03
Truss Type
Monopitch Truss
Qty
10
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461159
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:40 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-MslvmJTzsshYpEcWphoAaCqKcxnsXb_64Fk8e0zKZcX
Scale = 1:22.1
T1
W3
B1
W1 W2
1
2
3
4
6
5
1.5x4
3x4
3x4
3x4
1.5x4
6-5-14
6-5-14
12-2-4
5-8-6
-1-6-6
1-6-6
6-5-14
6-5-14
12-2-4
5-8-6
0-3-14
3-7-8
3.25 12
Plate Offsets (X,Y): [2:0-3-4,0-0-2]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
Job
B12211197
Truss
M04
Truss Type
Monopitch Truss
Qty
14
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461160
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:41 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-q2JH_eTbdApPROBiMOJP6QNUFL9oGE0FIvThBSzKZcW
Scale = 1:36.8
T1
W2
B1
W1
1
2
3
5
4
3x4
3x8 2x4
6-0-0
6-0-0
-1-0-0
1-0-0
6-0-0
6-0-0
0-10-14
6-10-14
6-7-6
0-3-8
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
Job
B12211197
Truss
PB01
Truss Type
Piggyback Truss
Qty
4
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461161
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:41 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-q2JH_eTbdApPROBiMOJP6QNV2L9nGEJFIvThBSzKZcW
Scale = 1:19.6
T1 T1
B1
ST1
1
2
3
4
5
6
4x6
2x4 1.5x4 2x4
9-9-10
9-9-10
4-10-13
4-10-13
9-9-10
4-10-13
0-4-7
3-3-3
0-1-8
0-4-7
0-1-8
8.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
Job
B12211197
Truss
PB02
Truss Type
Piggyback Truss
Qty
17
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461162
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:41 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-q2JH_eTbdApPROBiMOJP6QNVxL8rGD2FIvThBSzKZcW
Scale = 1:26.5
T1 T1
B1
ST1
1
2
3
4 5
6
4x6
3x12 3x12
1.5x4
13-10-14
13-10-14
6-11-7
6-11-7
13-10-14
6-11-7
0-4-7
4-7-10
0-1-8
0-4-7
0-1-8
8.00 12
Plate Offsets (X,Y): [2:1-0-7,0-1-6], [4:1-0-7,0-1-6]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
Job
B12211197
Truss
PB03
Truss Type
Piggyback Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461163
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:41 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-q2JH_eTbdApPROBiMOJP6QNYfLAKGE0FIvThBSzKZcW
Scale = 1:12.9
T1 T1
B1
1
2
3
4
5
3x4
2x4 2x4
4-7-12
4-7-12
2-3-14
2-3-14
4-7-12
2-3-14
0-5-3
2-3-14
0-1-8
0-5-3
0-1-8
12.00 12
Plate Offsets (X,Y): [2:0-2-6,0-1-0], [3:0-2-0,Edge], [4:0-2-6,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
Job
B12211197
Truss
PBE01
Truss Type
GABLE
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461164
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:41 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-q2JH_eTbdApPROBiMOJP6QNXBLB4GEWFIvThBSzKZcW
Scale = 1:19.6
T1 T1
B1
ST2
ST1 ST1
1
2
3
4
5
6
7
10 9 8
4x6
2x4 1.5x4 1.5x4 2x4
1.5x4
1.5x4
1.5x4
9-9-10
9-9-10
4-10-13
4-10-13
9-9-10
4-10-13
0-4-7
3-3-3
0-1-8
0-4-7
0-1-8
8.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
Job
B12211197
Truss
PBE02
Truss Type
GABLE
Qty
2
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461165
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:42 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-IFtgB_UDOTxG3Ymuw6qefdvjPlWd?htOXYDEjuzKZcV
Scale = 1:26.5
T1 T1
B1
ST4
ST3
ST2
ST1
ST3
ST2
ST1
1
2
3
4
5
6
7
8
9
10
11
18 17 16 15 14 13 12
4x6
3x4 3x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
13-10-14
13-10-14
6-11-7
6-11-7
13-10-14
6-11-7
0-4-7
4-7-10
0-1-8
Job
B12211197
Truss
PBE03
Truss Type
GABLE
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461166
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:42 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-IFtgB_UDOTxG3Ymuw6qefdvjOlWf?h6OXYDEjuzKZcV
Scale = 1:12.9
T1 T1
B1
ST1
1
2
3
4
5
6
4x6
2x4 1.5x4 2x4
4-7-12
4-7-12
2-3-14
2-3-14
4-7-12
2-3-14
0-5-3
2-3-14
0-1-8
0-5-3
0-1-8
12.00 12
Plate Offsets (X,Y): [2:0-2-6,0-1-0], [4:0-2-6,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
Job
B12211197
Truss
T01
Truss Type
Common Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461167
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:43 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-mRR2OKVr9n36giL5UpMtBrSmE9kMk1FYmCyoFKzKZcU
Scale = 1:71.7
T2
T3
T2
B1
W1
W2
W3
W4
W5 W5
W4
W3
W2
W1
HW1 HW1
T1 T1
B2 B1
1
2
3
4
5
6 7 8
9
10
11
12
13
19 18 17 16
15 14
3x6
5x6
5x6
3x6
6x8
3x4 3x6
1.5x4
3x4
3x8
3x4
3x8
3x4
3x4
1.5x4
6x8
Job
B12211197
Truss
T01A
Truss Type
Common Truss
Qty
3
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461168
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:43 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-mRR2OKVr9n36giL5UpMtBrSmD9kKk14YmCyoFKzKZcU
Scale = 1:71.6
T2
T3
T2
B1
W1
W2
W3
W4
W5 W5
W4
W3
W2
W1
HW1 HW1
T1
T4
B2 B1
1
2
3
4
5
6 7 8
9
10
11
12
18 17 16 15
14 13
3x6
5x6
5x6
3x6
6x8
3x4 3x6
1.5x4
3x4
3x8
3x4
3x8
3x4
3x4
1.5x4
6x8
Job
B12211197
Truss
T03
Truss Type
Common Truss
Qty
2
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461169
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:43 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-mRR2OKVr9n36giL5UpMtBrSrH9qik6HYmCyoFKzKZcU
Scale = 1:39.1
T1
T2
B1
W2
W1 W1
1
2
3
4
7
6
5
4x6
4x10
4x10 1.5x4
5-11-8
5-11-8
11-11-0
5-11-8
-1-0-0
1-0-0
5-11-8
5-11-8
11-11-0
5-11-8
0-10-14
6-10-6
0-10-14
12.00 12
Plate Offsets (X,Y): [4:Edge,0-3-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
Job
B12211197
Truss
T04
Truss Type
Special Truss
Qty
2
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461170
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:44 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-Ed?QcgWUw5BzIrwH2Xt6k2?x_Y4aTRzh_siLnnzKZcT
Scale = 1:72.3
T2
T3
T4
B1
W1
W2
W3
W4
W5
W4
W5
W4
W6 W7
HW1
W9
W8
T1
B2 B3
1
2
3
4
5
6 7 8
9
10
18 17
16 15
14
13 12 11
3x6
5x6
5x6
5x6
6x8
3x4 3x6
1.5x4
3x4
3x8 1.5x4
3x8
3x8
3x4
3x6
3x6 2x4
Job
B12211197
Truss
T06
Truss Type
Special Truss
Qty
7
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461171
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:44 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-Ed?QcgWUw5BzIrwH2Xt6k2?_YY5bTNeh_siLnnzKZcT
Scale = 1:71.8
T2
T3
T4
B1
W1
W2
W3
W4
W5
W4
W5
W4
W6
W7
HW1
W9
W8
T1
B2 B3
1
2
3
4
5 6 7
8
9
17 16 15 14
13 12
11 10
3x6
5x6
5x6
3x4
5x6
3x4 3x6
1.5x4
3x4
3x8 1.5x4
3x8
5x8 2x4 3x6
6x8
3x6
8-2-15
8-2-15
Job
B12211197
Truss
T07
Truss Type
Common Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461172
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:44 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-Ed?QcgWUw5BzIrwH2Xt6k2?_ZY6OTWJh_siLnnzKZcT
Scale = 1:56.8
T1 T2
B1
W3
W2 W2
W1 W1
B2
1
2
3
4
5
6
10
9 8
7
4x6
4x10
4x10 3x6
3x8
1.5x4
1.5x4
9-2-0
9-2-0
18-4-0
9-2-0
-1-0-0
1-0-0
4-8-4
4-8-4
9-2-0
4-5-12
13-7-12
4-5-12
18-4-0
4-8-4
0-10-14
10-0-14
0-10-14
12.00 12
Plate Offsets (X,Y): [6:Edge,0-3-8]
LOADING (psf)
TCLL
TCDL
BCLL
Job
B12211197
Truss
T08
Truss Type
Special Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461173
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:45 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-ipZop0W6gOJqw?VTbEOLHGX9NyOiCrurDWRvKDzKZcS
Scale = 1:66.7
T2
T3
T4
B1
W1
W2
W3
W4
W5
W4
W5
HW1
W7
W6
T1
B2 B3
1
2
3
4
5 6 7
8
14 13
12
11
10 9
3x6
4x8
5x6
3x4
6x6
3x4 3x6
1.5x4
3x4
3x4
1.5x4
4x8
3x6 3x6
8-2-15
8-2-15
16-4-11
8-1-12
23-5-14
7-1-3
Job
B12211197
Truss
T09
Truss Type
Special Truss
Qty
7
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461174
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:45 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-ipZop0W6gOJqw?VTbEOLHGX4GyLACrxrDWRvKDzKZcS
Scale = 1:67.1
T1
T2
T3
T4
B1
W3
W4
W5
W6
W7
W6
W7
W1
W2
W9
W8
B2 B1
1
2
3
4 5 6
7
14 13 12
11 10
9 8
5x8
4x8
5x6
3x4
2x4 4x10 3x8
3x4
3x4
1.5x4
4x8
5x6
3x6 3x6
7-6-2
7-6-2
16-4-11
8-10-9
23-5-14
7-1-3
33-11-8
10-5-10
Job
B12211197
Truss
T11
Truss Type
Special Truss
Qty
3
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461175
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:45 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-ipZop0W6gOJqw?VTbEOLHGX3gyNMCtvrDWRvKDzKZcS
Scale = 1:73.7
T1
T2
T3
B1
W3
W4
W5
W6
W5
W7
W1 W8
W2
HW2
T4
B2 B3
1
2
3
4
5
6
7
8 9
15 14
13 12
11 10
5x8
5x6
3x6
2x4 4x10 3x6
3x4
3x8
3x4
3x4
1.5x4
5x6
5x8
3x6
7-6-2
7-6-2
17-11-8
10-5-6
27-1-0
9-1-8
Job
B12211197
Truss
T12
Truss Type
Common Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461176
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:46 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-A07A1MXkRiRhX94g9xvapT4MAMs4xTx_SABSsfzKZcR
Scale = 1:40.8
T1
T2
B1
W2
W1 W1
1
2
3
4
7
6
5
4x6
3x12
3x12 1.5x4
6-3-8
6-3-8
12-7-0
6-3-8
-1-0-0
1-0-0
6-3-8
6-3-8
12-7-0
6-3-8
0-10-14
7-2-6
0-10-14
12.00 12
Plate Offsets (X,Y): [4:0-3-8,Edge], [7:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
Job
B12211197
Truss
T13
Truss Type
Special Truss
Qty
2
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461177
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:46 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-A07A1MXkRiRhX94g9xvapT4EtMhpxMO_SABSsfzKZcR
Scale = 1:70.2
T1
T2
T3
B1
W3
W4
W5
W6
W5
W7
W1
W2
W9
W8
T4
B2 B1
1
2
3
4
5
6
7
8
15 14 13
12 11
10 9
5x8
4x6
3x6
2x4 4x10 3x6
3x4
3x8
3x4
3x6
5x6
3x4
6x6
3x6
7-6-2
7-6-2
17-11-8
10-5-6
25-10-0
Job
B12211197
Truss
T14
Truss Type
SPECIAL TRUSS
Qty
3
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461178
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:46 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-A07A1MXkRiRhX94g9xvapT4EsMhoxMO_SABSsfzKZcR
Scale = 1:69.6
T1
T2
T3
B1
W3
W4
W5
W6
W5
W7
W1
W2
W9
W8
T4
B2 B1
1
2
3
4
5
6
7
14 13
12 11
10 9
8
5x8
4x6
3x6
2x4 4x10 3x6
3x4
3x8
3x4
3x6
5x6
3x4
5x6
3x6
7-6-2
7-6-2
17-11-8
10-5-6
25-10-0
Job
B12211197
Truss
T15
Truss Type
Common Truss
Qty
11
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461179
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:47 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-fCgZEiYMC0ZY9JfsjfQpMhdSxm87gse8hqx?O6zKZcQ
Scale = 1:69.3
T2 T2
B1
W3
W2
W3
W2
W1 W1
T1 T1
B2
1
2
3
4
5
6
7
8
9
14 13 12 11
10
3x6
4x6
3x6
5x12 3x6 3x4
1.5x4
3x4
1.5x4
5x12
7-5-13
7-5-13
14-9-3
7-3-5
22-3-0
7-5-13
-1-0-0
1-0-0
5-2-5
5-2-5
11-1-8
5-11-3
17-0-11
5-11-3
22-3-0
5-2-5
Job
B12211197
Truss
T16
Truss Type
Common Truss
Qty
7
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461180
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:47 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-fCgZEiYMC0ZY9JfsjfQpMhdSvm7ygsY8hqx?O6zKZcQ
Scale = 1:67.0
T2 T2
B1
W3
W2
W3
W2
T1
T3
B2
W1 W1
1
2
3
4
5
6
7
8
13 12 11 10
9
3x6
4x6
3x6
5x12 3x6 3x4
1.5x4
3x4
1.5x4
5x12
7-5-13
7-5-13
14-9-3
7-3-5
22-3-0
7-5-13
5-2-5
5-2-5
11-1-8
5-11-3
17-0-11
5-11-3
22-3-0
5-2-5
23-3-0
1-0-0
Job
B12211197
Truss
T17
Truss Type
Half Hip Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461181
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:47 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-fCgZEiYMC0ZY9JfsjfQpMhdXpmC9gwf8hqx?O6zKZcQ
Scale = 1:31.2
T1
T2
W3
B1
W2
W1
1
2
3 4
6
5
5x6 1.5x4
3x4
2x4
4x6
6-0-0
6-0-0
-1-0-0
1-0-0
4-8-0
4-8-0
6-0-0
1-4-0
0-10-14
5-5-1
5-6-14
5-1-9
0-3-8
5-5-1
12.00 12
Plate Offsets (X,Y): [3:0-4-3,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Job
B12211197
Truss
V01
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461182
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:48 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-7OExS2Z_zJhPnTE2HMx2uu9iHAZRPJVHvUgZxYzKZcP
Scale = 1:46.1
T1
T2
W1
B1
ST2
ST1 ST1
1
2
3
4
5
3x4 9 8 7 6
4x6
1.5x4
1.5x4 1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
14-1-11
14-1-11
8-1-8
8-1-8
14-1-11
6-0-4
0-0-4
8-1-8
2-1-4
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
Job
B12211197
Truss
V02
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461183
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:48 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-7OExS2Z_zJhPnTE2HMx2uu9iPAYQPNmHvUgZxYzKZcP
Scale = 1:38.6
T1 T1
B1
ST2
ST1 ST1
1
2
3
4
5
3x4 8 7 6
4x6
3x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
13-6-15
13-6-15
6-9-8
6-9-8
13-6-15
6-9-8
0-0-4
6-9-8
0-0-4
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
Job
B12211197
Truss
V03
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461184
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:48 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-7OExS2Z_zJhPnTE2HMx2uu9iFAWNPN?HvUgZxYzKZcP
Scale = 1:31.1
T1 T1
B1
ST1
1
2
3
3x8 4
4x6
3x8
1.5x4
10-10-15
10-10-15
5-5-8
5-5-8
10-10-15
5-5-8
0-0-4
5-5-8
0-0-4
12.00 12
Plate Offsets (X,Y): [1:0-5-13,Edge], [3:0-2-9,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
Job
B12211197
Truss
V04
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461185
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:48 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-7OExS2Z_zJhPnTE2HMx2uu9ilAYmPO0HvUgZxYzKZcP
Scale = 1:24.9
T1 T1
B1
ST1
1
2
3
4
2x4
4x6
1.5x4 2x4
8-2-15
8-2-15
4-1-8
4-1-8
8-2-15
4-1-8
0-0-4
4-1-8
0-0-4
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
Job
B12211197
Truss
V05
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461186
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:48 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-7OExS2Z_zJhPnTE2HMx2uu9jIAXePOlHvUgZxYzKZcP
Scale = 1:17.9
T1 T1
B1
1
2
3
2x4
3x4
2x4
5-6-15
5-6-15
2-9-8
2-9-8
5-6-15
2-9-8
0-0-4
2-9-8
0-0-4
12.00 12
Plate Offsets (X,Y): [2:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.07
Job
B12211197
Truss
V06
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461187
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:48 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-7OExS2Z_zJhPnTE2HMx2uu9kBAZrPOlHvUgZxYzKZcP
Scale = 1:9.5
T1 T1
B1
1
2
3
2x4
3x4
2x4
2-10-15
2-10-15
1-5-8
1-5-8
2-10-15
1-5-8
0-0-4
1-5-8
0-0-4
12.00 12
Plate Offsets (X,Y): [2:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.01
Job
B12211197
Truss
V07
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461188
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:49 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-bboJfNackdpGOdoEq4SHR6itcZui8osQ88Q6T_zKZcO
Scale = 1:53.8
T1
T2
W1
B1
ST2
ST1 ST1
B2
1
2
3
4
5
3x6 10 9 8 7 6
4x6
1.5x4
3x6 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
16-1-10
16-1-10
9-1-10
9-1-10
16-1-10
7-0-0
0-0-4
9-1-10
2-1-10
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Job
B12211197
Truss
V08
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461189
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:49 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-bboJfNackdpGOdoEq4SHR6it4Zvj8osQ88Q6T_zKZcO
Scale = 1:44.1
T1 T2
W1
B1
ST2
ST1 ST1
1
2
3
4
5
3x4 9 8 7 6
4x6
3x8
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
14-9-10
14-9-10
7-9-10
7-9-10
14-9-10
7-0-0
0-0-4
7-9-10
0-9-10
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Job
B12211197
Truss
V09
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461190
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:49 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-bboJfNackdpGOdoEq4SHR6iuBZue8qCQ88Q6T_zKZcO
Scale = 1:36.9
T1 T1
B1
ST2
ST1 ST1
1
2
3
4
5
3x4 8 7 6
4x6
3x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
12-11-5
12-11-5
6-5-10
6-5-10
12-11-5
6-5-10
0-0-4
6-5-10
0-0-4
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
Job
B12211197
Truss
V10
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461191
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:49 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-bboJfNackdpGOdoEq4SHR6iuGZtz8qZQ88Q6T_zKZcO
Scale = 1:29.4
T1 T1
B1
ST1
1
2
3
3x6 4
4x6
3x6
1.5x4
10-3-5
10-3-5
5-1-10
5-1-10
10-3-5
5-1-10
0-0-4
5-1-10
0-0-4
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
Job
B12211197
Truss
V11
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461192
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:50 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-3nMhsjaEVxx70mNROn_W_JF2hzEUtIgaNo9g?QzKZcN
Scale = 1:23.0
T1 T1
B1
ST1
1
2
3
4
2x4
4x6
2x4
1.5x4
7-7-5
7-7-5
3-9-10
3-9-10
7-7-5
3-9-10
0-0-4
3-9-10
0-0-4
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
Job
B12211197
Truss
V12
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461193
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:50 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-3nMhsjaEVxx70mNROn_W_JF44zDntIFaNo9g?QzKZcN
Scale = 1:14.2
T1 T1
B1
1
2
3
2x4
3x4
2x4
4-11-5
4-11-5
2-5-10
2-5-10
4-11-5
2-5-10
0-0-4
2-5-10
0-0-4
12.00 12
Plate Offsets (X,Y): [2:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.05
Job
B12211197
Truss
V13
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461194
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:50 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-3nMhsjaEVxx70mNROn_W_JF4ozFatIFaNo9g?QzKZcN
Scale: 1.5"=1’
T1 T1
B1
1
2
3
2x4
3x4
2x4
2-3-5
2-3-5
1-1-10
1-1-10
2-3-5
1-1-10
0-0-4
1-1-10
0-0-4
12.00 12
Plate Offsets (X,Y): [2:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.01
Job
B12211197
Truss
V14
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461195
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:50 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-3nMhsjaEVxx70mNROn_W_JF0OzDhtIFaNo9g?QzKZcN
Scale = 1:25.5
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
4-10-0
4-10-0
4-10-0
4-10-0
0-0-4
4-10-0
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.29
0.14
0.00
DEFL
Job
B12211197
Truss
V15
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461196
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:50 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-3nMhsjaEVxx70mNROn_W_JF2hzEqtIFaNo9g?QzKZcN
Scale = 1:19.3
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
3-6-0
3-6-0
3-6-0
3-6-0
0-0-4
3-6-0
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.14
0.07
0.00
DEFL
Job
B12211197
Truss
V16
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461197
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:50 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-3nMhsjaEVxx70mNROn_W_JF4NzFYtIFaNo9g?QzKZcN
Scale = 1:13.0
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
2-2-0
2-2-0
2-2-0
2-2-0
0-0-4
2-2-0
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.03
0.02
0.00
DEFL
Job
B12211197
Truss
V17
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461198
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:51 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-Xzw343btGE3_ewydyVVlWXnB1NY2cj9jbSvDXtzKZcM
Scale = 1:37.2
T1
W1
B1
ST1
1
2
3
3x8 5 4
3x4
2x4
1.5x4
1.5x4
10-6-9
10-6-9
10-6-9
10-6-9
0-0-4
7-0-6
8.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.30
Job
B12211197
Truss
V18
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461199
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:51 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-Xzw343btGE3_ewydyVVlWXnBvNagclhjbSvDXtzKZcM
Scale = 1:27.6
T1
W1
B1
ST1
1
2
3
5 4
2x4
1.5x4
1.5x4 1.5x4
1.5x4
7-6-9
7-6-9
7-6-9
7-6-9
0-0-4
5-0-6
8.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.30
Job
B12211197
Truss
V19
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461200
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:51 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-Xzw343btGE3_ewydyVVlWXnDkNaJclVjbSvDXtzKZcM
Scale = 1:16.9
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
4-6-9
4-6-9
4-6-9
4-6-9
0-0-4
3-0-6
8.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.19
0.12
0.00
DEFL
Job
B12211197
Truss
V20
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461201
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:51 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-Xzw343btGE3_ewydyVVlWXnFUNb0clVjbSvDXtzKZcM
Scale = 1:7.5
T1
W1
B1
1
2
3
2x4
5x6
1-6-9
1-6-9
1-6-9
1-6-9
0-0-4
1-0-6
8.00 12
Plate Offsets (X,Y): [2:0-2-9,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.01
0.01
0.00
DEFL
Job
B12211197
Truss
V21
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461202
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:51 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-Xzw343btGE3_ewydyVVlWXnD6NauclVjbSvDXtzKZcM
Scale = 1:20.3
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
3-8-10
3-8-10
3-8-10
3-8-10
0-0-4
3-8-10
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.16
0.08
0.00
DEFL
Job
B12211197
Truss
V22
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461203
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:51 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-Xzw343btGE3_ewydyVVlWXnFzNbhclVjbSvDXtzKZcM
Scale = 1:14.0
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
2-4-10
2-4-10
2-4-10
2-4-10
0-0-4
2-4-10
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.04
0.03
0.00
DEFL
Job
B12211197
Truss
V23
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461204
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:37:58 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-Habp5Z14r?JvAKW9y4apuwUzzJry5kMk_2I8v5zKZWd
Scale = 1:7.6
T1
W1
B1
1
2
3
4x6
1-0-10
1-0-10
1-0-10
1-0-10
0-0-4
1-0-10
12.00 12
Plate Offsets (X,Y): [1:0-6-10,0-1-2]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.00
0.00
0.00
DEFL
Vert(LL)
Job
B12211197
Truss
V24
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461205
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:52 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-?AUSHPcV1YCrF4XpWC0_3kKPlnxZLCltq6em4JzKZcL
Scale = 1:17.3
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
3-0-14
3-0-14
3-0-14
3-0-14
0-0-4
3-0-14
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.11
0.05
0.00
DEFL
Job
B12211197
Truss
V25
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461206
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:52 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-?AUSHPcV1YCrF4XpWC0_3kKQcnxsLCltq6em4JzKZcL
Scale = 1:14.7
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
2-6-6
2-6-6
2-6-6
2-6-6
0-0-4
2-6-6
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.05
0.03
0.00
DEFL
Job
B12211197
Truss
V26
Truss Type
Valley Truss
Qty
1
Ply
1
Wedgewood Const. 17 Grandin Hall
Job Reference (optional)
I5461207
PROBUILD, MOORESVILLE, IN 46158 7.250 s May 11 2011 MiTek Industries, Inc. Wed May 02 10:31:52 2012 Page 1
ID:_lVL6e6?4WOx?qSzvojM7JzKvE1-?AUSHPcV1YCrF4XpWC0_3kKQznx4LCltq6em4JzKZcL
Scale: 1"=1’
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
1-11-14
1-11-14
1-11-14
1-11-14
0-0-4
1-11-14
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.03
0.02
0.00
DEFL
edge of truss.
/ 16 " from outside
1
0 -
PRODUCT CODE APPROVALS
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
W4-6
W3-6
W3-7
W2-7
W1-7
C1-8
C7-8 C6-7 C5-6
C4-5
C3-4
C1-2 C2-3
TOP CHORD
TOP CHORD
8 7 6 5
4
1 2 3
BOTTOM CHORDS
TOP CHORDS
BEARING
LATERAL BRACING LOCATION
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T, I or proprietay bracing
(e.g. eliminator) if indicated.
The first dimension is the plate
width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
4 x 4
PLATE SIZE
This symbol indicates the
required direction of slots in
connector plates.
/ 16 "
1
For 4 x 2 orientation, locate
plates 0-
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
1 "
/ 4
3
PLATE LOCATION AND ORIENTATION
Symbols Numbering System
1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See
BCSI1.
2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral
braces themselves may require bracing, or alternative T, I, or Eliminator bracing should be
considered.
3. Never exceed the design loading shown and never stack materials on inadequately braced
trusses.
4. Provide copies of this truss design to the building designer, erection supervisor, property
owner and all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from the environment in accord with
ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative
treated, or green lumber.
10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General
practice is to camber for dead load deflection.
11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless
otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable environmental, health or performance
risks. Consult with project engineer before use.
19. Review all portions of this design (front, back, words and pictures) before use. Reviewing
pictures alone is not sufficient.
20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.
21. Unless information is otherwise provided to DrJ in writing, the use of these designs presumes
approval, through the building designer or owner of the trusses, of the loads and related
design assumptions (e.g. spans, profiles, deflection, etc.) found on each of the individual
design drawings.
22. These trusses are designed using MiTek Sapphire standard analysis methods in accordance
with ANSI/TPI 1 and related proprietary information.
23. It is extremely important to properly install temporary lateral restraint and diagonal bracing, in
accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).
24. Sheathing applied in the plane of the truss is not considered in the design of the individual truss
components unless specifically noted.
25. Graphical purlin representation, if shown, does not depict the size or orientation of the purlin
along the top and/or bottom chord. Purlins must be designed by others for size, and positioned
in such a way as to support the imposed load along the clearspan of the purlin.
26. Due to the lateral thrust developed by scissor type trusses, if scissor type trusses are part of
this design, careful consideration should be given to bearing wall conditions. Bearing walls of
scissor type trusses should be designed in such a manner that the walls will safely withstand
the lateral forces of the trusses. Consideration of these items is not a part of this truss design
and is not the responsibility of the truss plate supplier, the truss designer, nor the truss
fabricator. Competent professional advice should be secured relative to these items.
27. The accuracy of the truss design drawing relies upon accurate metal plate connector
design values as published by MiTek and accurate design values for solid sawn lumber.
Design values (E, Emin, Fb, Fc, Fcp, Ft, and Fv) for solid sawn lumber and approved,
grade stamped, finger jointed lumber shall be as defined by the grade stamp prior to
cross cutting and in accordance with the published values of lumber rules writing
agencies approved by the Board of Review of the American Lumber Standards
Committee in accordance with the latest edition of ANSI/TPI 1 Section 6.3.
Failure to Follow Could Cause Property
Damage or Personal Injury
General Safety Notes
* Plate location details available in MiTek 20/20
software or upon request.
Industry Standards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI1: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
' 2011 DrJ Consulting, LLC All Rights Reserved
WEBS
edge of truss.
/ 16 " from outside
1
0 -
ICC-ES Reports:
ESR-1311, ESR-1352, ER-5243, 9604B,
9730, 95-43, 96-31, 9667A
NER-487, NER-561
95110, 84-32, 96-67, ER-3907, 9432A
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
W4-6
W3-6
W3-7
W2-7
W1-7
C1-8
C7-8 C6-7 C5-6
C4-5
C3-4
C1-2 C2-3
TOP CHORD
TOP CHORD
8 7 6 5
4
1 2 3
BOTTOM CHORDS
TOP CHORDS
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
4 x 4
PLATE SIZE
This symbol indicates the
required direction of slots in
connector plates.
/ 16 "
1
For 4 x 2 orientation, locate
plates 0-
1 "
/ 4
3
PLATE LOCATION AND ORIENTATION
Symbols Numbering System General Safety Notes
* Plate location details available in MiTek 20/20
software or upon request.
Industry Standards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI1: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
6-4-8 dimensions shown in ft-in-sixteenths
WEBS
DrJ Consulting, LLC
6300 Enterprise Lane
Madison, WI 53719
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 6 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 1-11-14 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=61/1-11-14 (min. 0-1-8), 3=61/1-11-14 (min. 0-1-8)
Max Horz 1=46(LC 5)
Max Uplift 3=-18(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 8 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-6-6 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=83/2-6-6 (min. 0-1-8), 3=83/2-6-6 (min. 0-1-8)
Max Horz 1=63(LC 5)
Max Uplift 3=-25(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 10 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-0-14 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=105/3-0-14 (min. 0-1-8), 3=105/3-0-14 (min. 0-1-8)
Max Horz 1=79(LC 5)
Max Uplift 3=-31(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 3 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 1-0-10 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=24/1-0-10 (min. 0-1-8), 3=24/1-0-10 (min. 0-1-8)
Max Horz 1=18(LC 5)
Max Uplift 3=-7(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 7 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-4-10 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=77/2-4-10 (min. 0-1-8), 3=77/2-4-10 (min. 0-1-8)
Max Horz 1=58(LC 5)
Max Uplift 3=-23(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 12 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-8-10 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=131/3-8-10 (min. 0-1-8), 3=131/3-8-10 (min. 0-1-8)
Max Horz 1=98(LC 5)
Max Uplift 3=-39(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 4 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 1-6-9 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=38/1-6-9 (min. 0-1-8), 3=38/1-6-9 (min. 0-1-8)
Max Horz 1=19(LC 5)
Max Uplift 3=-7(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 13 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-6-9 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=158/4-6-9 (min. 0-1-8), 3=158/4-6-9 (min. 0-1-8)
Max Horz 1=80(LC 5)
Max Uplift 3=-27(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.09
0.05
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 23 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=82/7-6-9 (min. 0-1-8), 4=124/7-6-9 (min. 0-1-8), 5=352/7-6-9 (min. 0-1-8)
Max Horz 1=140(LC 5)
Max Uplift 1=-9(LC 4), 4=-22(LC 5), 5=-90(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-264/155
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.20
0.15
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 34 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=196/10-6-9 (min. 0-1-8), 4=84/10-6-9 (min. 0-1-8), 5=517/10-6-9 (min. 0-1-8)
Max Horz 1=200(LC 5)
Max Uplift 4=-30(LC 5), 5=-133(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-364/175
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=133.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 7 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=68/2-2-0 (min. 0-1-8), 3=68/2-2-0 (min. 0-1-8)
Max Horz 1=51(LC 5)
Max Uplift 3=-20(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-6-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=122/3-6-0 (min. 0-1-8), 3=122/3-6-0 (min. 0-1-8)
Max Horz 1=92(LC 5)
Max Uplift 3=-36(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-10-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=175/4-10-0 (min. 0-1-8), 3=175/4-10-0 (min. 0-1-8)
Max Horz 1=132(LC 5)
Max Uplift 3=-52(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.02
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 5 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-3-5 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=63/2-3-5 (min. 0-1-8), 3=63/2-3-5 (min. 0-1-8)
Max Horz 1=-18(LC 4)
Max Uplift 1=-2(LC 7), 3=-2(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.13
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 13 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-11-5 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=169/4-11-5 (min. 0-1-8), 3=169/4-11-5 (min. 0-1-8)
Max Horz 1=-49(LC 4)
Max Uplift 1=-5(LC 7), 3=-5(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
(Matrix)
0.14
0.09
0.04
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 22 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=173/7-7-5 (min. 0-1-8), 3=173/7-7-5 (min. 0-1-8), 4=206/7-7-5 (min. 0-1-8)
Max Horz 1=-80(LC 4)
Max Uplift 1=-29(LC 7), 3=-29(LC 7)
Max Grav 1=173(LC 1), 3=173(LC 1), 4=212(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.12
0.17
0.09
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 31 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=217/10-3-5 (min. 0-1-8), 3=217/10-3-5 (min. 0-1-8), 4=332/10-3-5 (min. 0-1-8)
Max Horz 1=-111(LC 4)
Max Uplift 1=-20(LC 7), 3=-20(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.13
0.07
0.12
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 42 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 12-11-5.
(lb) - Max Horz 1=-142(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-148(LC 6), 6=-148(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=301(LC 10), 6=301(LC 11)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=148, 6=148.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.13
0.06
0.20
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
6
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 52 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 14-9-10.
(lb) - Max Horz 1=180(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-171(LC 6), 7=-177(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 6, 8 except 9=352(LC 10), 7=320(LC 11)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-260/207
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=171, 7=177.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.16
0.13
0.20
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
6
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 60 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-8
REACTIONS All bearings 16-1-10.
(lb) - Max Horz 1=227(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 6, 8 except 1=-118(LC 4), 10=-204(LC 6), 7=-166(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=341(LC 7), 10=426(LC 10), 7=324(LC 11)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-250/261, 2-3=-112/269, 3-4=-105/250
WEBS 3-8=-289/74, 2-10=-305/240
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 8 except (jt=lb) 1=118, 10=204, 7=166.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.04
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 7 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-10-15 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=88/2-10-15 (min. 0-1-8), 3=88/2-10-15 (min. 0-1-8)
Max Horz 1=-26(LC 4)
Max Uplift 1=-2(LC 7), 3=-2(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.18
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 14 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-6-15 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=195/5-6-15 (min. 0-1-8), 3=195/5-6-15 (min. 0-1-8)
Max Horz 1=-57(LC 4)
Max Uplift 1=-5(LC 7), 3=-5(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.17
0.11
0.05
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 24 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=189/8-2-15 (min. 0-1-8), 3=189/8-2-15 (min. 0-1-8), 4=225/8-2-15 (min. 0-1-8)
Max Horz 1=-88(LC 4)
Max Uplift 1=-31(LC 7), 3=-31(LC 7)
Max Grav 1=189(LC 1), 3=189(LC 1), 4=232(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
(Matrix)
0.14
0.20
0.11
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 33 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=231/10-10-15 (min. 0-1-8), 3=231/10-10-15 (min. 0-1-8), 4=355/10-10-15 (min. 0-1-8)
Max Horz 1=119(LC 5)
Max Uplift 1=-21(LC 7), 3=-21(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.13
0.06
0.13
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 45 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 13-6-15.
(lb) - Max Horz 1=-150(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-152(LC 6), 6=-152(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=310(LC 10), 6=310(LC 11)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=152, 6=152.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.14
0.06
0.34
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
6
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 52 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 14-1-11.
(lb) - Max Horz 1=203(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 6, 8 except 1=-108(LC 4), 9=-177(LC 6), 7=-157(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=289(LC 1), 9=368(LC 10), 7=296(LC 11)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-270/214
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 8 except (jt=lb) 1=108, 9=177, 7=157.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.18
0.13
0.12
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.04
-0.11
0.00
0.03
(loc)
5-6
5-6
5
5-6
l/defl
>999
>620
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 28 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
W3: 2 X 4 SPF Stud, W2: 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and
2-0-0 oc purlins: 3-4.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): 4
REACTIONS (lb/size) 6=304/0-3-8 (min. 0-1-8), 5=221/0-1-8 (min. 0-1-8)
Max Horz 6=198(LC 6)
Max Uplift 5=-78(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-6=-250/46
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0-10-14
12-0-6
0-10-14
12.00 12
Plate Offsets (X,Y): [9:0-3-8,Edge], [13:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.50
0.46
0.38
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.10
-0.26
0.02
0.05
(loc)
10-12
10-12
9
10-12
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 110 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SP No.2 *Except*
W2: 2 X 3 SPF No.2, W1: 2 X 4 SYP No.1
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-6-15 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 13=877/0-3-8 (min. 0-1-8), 9=949/0-3-8 (min. 0-1-8)
Max Horz 13=-297(LC 4)
Max Uplift 13=-27(LC 7), 9=-57(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-986/114, 2-3=-865/199, 3-4=-846/250, 4-5=-844/248, 5-6=-863/198, 6-7=-990/114, 1-13=-782/96,
7-9=-863/136
BOT CHORD 12-13=-88/613, 11-12=-4/415, 10-11=-4/415, 9-10=0/606
WEBS 4-10=-142/375, 4-12=-144/378, 2-12=-254/245
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) The Fabrication Tolerance at joint 13 = 4%, joint 9 = 4%
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 9.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
23-3-0
1-0-0
0-10-14
12-0-6
0-10-14
12.00 12
Plate Offsets (X,Y): [10:0-3-8,Edge], [14:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.50
0.39
0.38
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.09
-0.23
0.02
0.04
(loc)
11-13
11-13
10
11-13
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 112 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SP No.2 *Except*
W2: 2 X 3 SPF No.2, W1: 2 X 4 SYP No.1
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-7-3 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 14=947/0-3-8 (min. 0-1-8), 10=947/0-3-8 (min. 0-1-8)
Max Horz 14=283(LC 5)
Max Uplift 14=-57(LC 6), 10=-57(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-987/113, 3-4=-860/197, 4-5=-841/248, 5-6=-841/248, 6-7=-860/197, 7-8=-987/113, 2-14=-861/135,
8-10=-861/135
BOT CHORD 13-14=-88/604, 12-13=-3/414, 11-12=-3/414, 10-11=0/604
WEBS 5-11=-142/373, 5-13=-142/373
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) The Fabrication Tolerance at joint 14 = 4%, joint 10 = 4%
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 10.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
7-10-8
33-11-0
8-1-0
7-6-2
7-6-2
10-2-4
2-8-2
17-11-8
7-9-4
25-10-0
7-10-8
33-11-0
8-1-0
3-6-9
5-6-15
12-6-9
1-10-14
3.25 12
8.00 12
Plate Offsets (X,Y): [7:Edge,0-1-12], [9:0-2-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.71
0.84
0.57
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.27
-0.73
0.05
0.07
(loc)
11-13
11-13
8
11-13
l/defl
>999
>549
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 165 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W5,W6: 2 X 4 SP No.2, W1,W9: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-1-11 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-11, 6-11
REACTIONS (lb/size) 14=1345/0-3-8 (min. 0-2-2), 8=1345/0-3-8 (min. 0-2-2)
Max Horz 14=306(LC 5)
Max Uplift 14=-62(LC 6), 8=-50(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1617/164, 2-3=-1833/241, 3-4=-1277/230, 4-5=-1140/233, 5-6=-1286/186, 6-7=-1602/165,
1-14=-1287/149, 7-8=-1268/134
BOT CHORD 13-14=-280/204, 12-13=-70/1375, 11-12=-70/1375, 10-11=-4/1237, 9-10=-4/1237
WEBS 2-13=-833/166, 3-13=-62/449, 3-11=-591/191, 4-11=-109/836, 6-11=-435/181, 1-13=-62/1586, 7-9=-1/1133
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 8.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
7-10-8
33-11-0
8-1-0
7-6-2
7-6-2
10-2-4
2-8-2
17-11-8
7-9-4
25-10-0
7-10-8
33-11-0
8-1-0
34-11-0
1-0-0
3-6-9
5-6-15
12-6-9
1-10-14
3.25 12
8.00 12
Plate Offsets (X,Y): [10:0-2-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.71
0.84
0.57
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.27
-0.73
0.05
0.07
(loc)
12-14
12-14
9
12-14
l/defl
>999
>549
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 167 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W5,W6: 2 X 4 SP No.2, W1,W9: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-1-13 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-12, 6-12
REACTIONS (lb/size) 15=1344/0-3-8 (min. 0-2-2), 9=1415/0-3-8 (min. 0-2-4)
Max Horz 15=297(LC 5)
Max Uplift 15=-62(LC 6), 9=-85(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1615/165, 2-3=-1831/243, 3-4=-1275/231, 4-5=-1139/234, 5-6=-1282/186, 6-7=-1602/171,
1-15=-1286/150, 7-9=-1338/171
BOT CHORD 14-15=-271/216, 13-14=-58/1373, 12-13=-58/1373, 11-12=0/1229, 10-11=0/1229
WEBS 2-14=-833/167, 3-14=-62/450, 3-12=-591/191, 4-12=-108/829, 6-12=-426/180, 1-14=-63/1584, 7-10=0/1084
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 9.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.24
0.18
0.09
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.03
-0.08
0.01
0.04
(loc)
6-7
6-7
5
6-7
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 43 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
W2: 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 7=564/0-3-8 (min. 0-1-8), 5=488/0-3-8 (min. 0-1-8)
Max Horz 7=184(LC 5)
Max Uplift 7=-47(LC 6), 5=-16(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-486/85, 3-4=-479/82, 2-7=-510/133, 4-5=-432/90
WEBS 3-6=0/269
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
35-11-0
8-10-0
7-6-2
7-6-2
11-3-0
3-8-14
17-11-8
6-8-8
24-8-0
6-8-8
30-3-11
5-7-11
35-11-0
5-7-5
36-11-0
1-0-0
3-6-9
5-6-15
12-6-9
0-6-14
3.25 12
8.00 12
Plate Offsets (X,Y): [8:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.74
0.73
0.65
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.26
-0.73
0.09
0.08
(loc)
12-14
12-14
8
12-14
l/defl
>999
>583
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 156 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W6: 2 X 4 SP No.2, W1: 2 X 4 SPF No.2
WEDGE
Right: 2 X 6 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-11-1 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-12, 5-12
REACTIONS (lb/size) 15=1424/Mechanical, 8=1495/0-3-8 (min. 0-2-6)
Max Horz 15=281(LC 5)
Max Uplift 15=-63(LC 6), 8=-96(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1729/172, 2-3=-2005/277, 3-4=-1394/243, 4-5=-1396/244, 5-6=-1763/212, 6-7=-1932/191,
7-8=-2121/185, 1-15=-1365/154
BOT CHORD 14-15=-254/213, 13-14=-36/1420, 12-13=-36/1420, 11-12=0/1433, 10-11=0/1433, 8-10=-56/1663
WEBS 2-14=-947/205, 3-14=-64/492, 3-12=-556/188, 4-12=-136/1027, 5-12=-575/188, 5-10=0/426, 1-14=-71/1704
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 8.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
7-6-2
7-6-2
10-10-6
3-4-5
16-4-11
5-6-5
23-5-14
7-1-3
30-3-9
6-9-11
33-11-8
3-7-15
3-6-9
5-6-15
11-6-0
9-0-11
11-6-0
3.25 12
8.00 12
Plate Offsets (X,Y): [4:0-5-12,0-2-0], [6:0-3-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.70
0.87
0.77
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.34
-0.88
0.05
0.08
(loc)
8-9
8-9
8
8-9
l/defl
>999
>461
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 206 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SP No.2 *Except*
W3,W4,W5,W2: 2 X 3 SPF No.2, W1,W9: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-2-6 oc purlins, except end verticals, and
2-0-0 oc purlins (5-6-12 max.): 4-6.
BOT CHORD Structural wood sheathing directly applied or 9-11-1 oc bracing.
WEBS 1 Row at midpt 3-11, 4-9, 5-9, 6-9, 7-8, 6-8
REACTIONS (lb/size) 14=1347/Mechanical, 8=1347/0-3-8 (min. 0-2-2)
Max Horz 14=369(LC 5)
Max Uplift 14=-51(LC 6), 8=-77(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1616/177, 2-3=-1878/282, 3-4=-1327/245, 4-5=-903/230, 5-6=-903/230, 1-14=-1284/157
BOT CHORD 13-14=-343/170, 12-13=-265/1323, 11-12=-265/1323, 10-11=-222/1031, 9-10=-222/1031, 8-9=-130/374
WEBS 2-13=-915/212, 3-13=-75/482, 3-11=-488/165, 4-11=-42/550, 5-9=-481/201, 6-9=-130/1029, 1-13=-77/1584,
6-8=-1214/241
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 8.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
33-11-8
10-5-10
5-6-6
5-6-6
10-11-9
5-5-2
16-4-11
5-5-2
23-5-14
7-1-3
30-3-9
6-9-11
33-11-8
3-7-15
0-6-14
11-6-0
9-0-11
11-6-0
8.00 12
Plate Offsets (X,Y): [5:0-5-12,0-2-0], [7:0-3-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.37
0.64
0.78
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.34
-0.86
0.07
0.08
(loc)
9-10
9-10
9
9-10
l/defl
>999
>471
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 197 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SP No.2 *Except*
W1,W2,W3: 2 X 3 SPF No.2, W7: 2 X 4 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-9-3 oc purlins, except end verticals, and
2-0-0 oc purlins (5-6-6 max.): 5-7.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 10-12.
WEBS 1 Row at midpt 4-12, 5-10, 6-10, 7-10, 8-9, 7-9
REACTIONS (lb/size) 1=1350/Mechanical, 9=1350/0-3-8 (min. 0-2-2)
Max Horz 1=368(LC 5)
Max Uplift 1=-49(LC 6), 9=-73(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2032/181, 2-3=-1860/184, 3-4=-1698/216, 4-5=-1331/240, 5-6=-906/226, 6-7=-906/226
BOT CHORD 1-14=-286/1600, 13-14=-253/1338, 12-13=-253/1338, 11-12=-218/1033, 10-11=-218/1033, 9-10=-129/375
WEBS 4-14=-18/447, 4-12=-518/171, 5-12=-54/545, 6-10=-481/202, 7-10=-126/1034, 7-9=-1218/237
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.38
0.39
0.29
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.13
-0.33
0.02
0.03
(loc)
8-10
8-10
7
8-10
l/defl
>999
>649
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 72 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W1: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-9-6 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 10=793/0-5-8 (min. 0-1-8), 7=719/0-5-8 (min. 0-1-8)
Max Horz 10=251(LC 5)
Max Uplift 10=-53(LC 6), 7=-22(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-773/106, 3-4=-594/154, 4-5=-595/154, 5-6=-774/106, 2-10=-701/132, 6-7=-625/92
BOT CHORD 9-10=-89/461, 8-9=-89/461, 7-8=0/469
WEBS 4-8=-123/476
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
16-4-11
8-1-12
23-4-2
6-11-7
30-3-9
6-11-7
33-9-12
3-6-3
42-7-0
8-9-4
5-6-6
5-6-6
10-11-9
5-5-2
16-4-11
5-5-2
23-4-2
6-11-7
30-3-9
6-11-7
36-4-1
6-0-8
42-7-0
6-2-15
0-6-14
11-6-0
3-3-11
11-6-0
8.00 12
Plate Offsets (X,Y): [1:Edge,0-1-4], [5:0-4-4,0-2-4], [7:0-4-4,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.38
0.51
0.84
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.15
-0.36
0.08
0.07
(loc)
10-11
10-11
10
1-17
l/defl
>696
>286
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 232 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W4,W5: 2 X 4 SP No.2, W9: 2 X 4 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-8-14 oc purlins, except end verticals,
and 2-0-0 oc purlins (5-2-0 max.): 5-7.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 11-12.
WEBS 1 Row at midpt 4-15, 6-15, 6-12, 7-12, 8-11, 8-10
REACTIONS (lb/size) 1=1364/Mechanical, 11=1618/0-3-8 (min. 0-2-9), 10=408/Mechanical
Max Horz 1=298(LC 5)
Max Uplift 1=-56(LC 6), 11=-2(LC 6), 10=-40(LC 7)
Max Grav 1=1364(LC 1), 11=1618(LC 1), 10=452(LC 11)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2054/199, 2-3=-1880/201, 3-4=-1715/234, 4-5=-1355/257, 5-6=-1052/249, 6-7=-439/209, 7-8=-643/208
BOT CHORD 1-17=-235/1619, 16-17=-201/1353, 15-16=-201/1353, 14-15=-159/933, 13-14=-159/933, 12-13=-159/933,
11-12=-379/118
WEBS 4-17=-20/440, 4-15=-517/172, 5-15=-32/404, 6-14=0/284, 6-12=-979/148, 8-12=-134/1224, 8-11=-1546/208,
8-10=-254/31
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 10.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
8-2-15
8-2-15
16-4-11
8-1-12
23-4-2
6-11-7
30-3-9
6-11-7
36-4-0
6-0-8
42-7-0
6-3-0
-1-0-0
1-0-0
5-6-6
5-6-6
10-11-9
5-5-2
16-4-11
5-5-2
23-4-2
6-11-7
30-3-9
6-11-7
36-4-0
6-0-8
42-7-0
6-3-0
0-6-14
11-6-0
3-3-11
11-6-0
8.00 12
Plate Offsets (X,Y): [2:0-0-12,Edge], [6:0-4-4,0-2-4], [8:0-4-4,0-2-4], [12:0-2-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.54
0.57
0.63
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.12
-0.37
0.13
0.08
(loc)
16-18
16-18
11
16
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 231 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W4,W5: 2 X 4 SP No.2, W9: 2 X 4 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-3-14 oc purlins, except end verticals,
and 2-0-0 oc purlins (4-2-10 max.): 6-8.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-16, 7-16, 7-13
REACTIONS (lb/size) 2=1761/0-3-8 (min. 0-2-12), 11=1691/Mechanical
Max Horz 2=304(LC 5)
Max Uplift 2=-92(LC 6), 11=-32(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2583/229, 3-4=-2412/231, 4-5=-2320/264, 5-6=-1926/293, 6-7=-1531/279, 7-8=-1330/266,
8-9=-1703/275, 9-10=-1619/190, 10-11=-1633/160
BOT CHORD 2-18=-219/2035, 17-18=-185/1813, 16-17=-185/1813, 15-16=-136/1612, 14-15=-136/1612, 13-14=-136/1612,
12-13=-14/1273
WEBS 5-18=-15/407, 5-16=-493/170, 6-16=-52/680, 7-16=-309/194, 7-15=0/266, 7-13=-632/165, 8-13=-38/547,
9-12=-501/101, 10-12=-49/1385
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.22
0.16
0.08
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.02
-0.07
0.01
0.03
(loc)
6-7
6-7
5
6-7
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 41 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
W2: 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 7=537/0-3-8 (min. 0-1-8), 5=462/0-3-8 (min. 0-1-8)
Max Horz 7=177(LC 5)
Max Uplift 7=-46(LC 6), 5=-15(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-457/82, 3-4=-450/79, 2-7=-485/130, 4-5=-407/87
WEBS 3-6=0/253
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
3x6
8-2-15
8-2-15
16-4-11
8-1-12
26-2-5
9-9-10
34-4-1
8-1-12
42-7-0
8-2-15
-1-0-0
1-0-0
5-6-6
5-6-6
10-11-9
5-5-2
16-4-11
5-5-2
21-3-8
4-10-13
26-2-5
4-10-13
31-7-7
5-5-2
37-0-10
5-5-2
42-7-0
5-6-6
0-6-14
11-6-0
0-6-14
11-6-0
8.00 12
Plate Offsets (X,Y): [2:0-0-12,Edge], [6:0-4-4,0-2-4], [8:0-4-4,0-2-4], [12:0-0-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.54
0.57
0.41
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.20
-0.59
0.16
0.10
(loc)
15-16
15-16
12
15-16
l/defl
>999
>867
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 210 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W4,W5: 2 X 4 SP No.2
WEDGE
Left: 2 X 4 SPF No.2, Right: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-2-15 oc purlins, except
2-0-0 oc purlins (4-6-15 max.): 6-8.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-16, 7-16, 7-15, 9-15
REACTIONS (lb/size) 2=1765/0-3-8 (min. 0-2-12), 12=1694/Mechanical
Max Horz 2=267(LC 5)
Max Uplift 2=-92(LC 6), 12=-56(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2587/226, 3-4=-2415/227, 4-5=-2250/260, 5-6=-1937/286, 6-7=-1538/272, 7-8=-1541/273,
8-9=-1941/287, 9-10=-2276/266, 10-11=-2441/233, 11-12=-2615/232
BOT CHORD 2-18=-117/2038, 17-18=-71/1819, 16-17=-71/1819, 15-16=-13/1604, 14-15=-37/1831, 13-14=-37/1831,
12-13=-116/2074
WEBS 5-18=-19/391, 5-16=-496/173, 6-16=-63/733, 7-16=-314/196, 7-15=-308/197, 8-15=-63/735, 9-15=-510/176,
9-13=-25/408
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
3x6
8-2-15
8-2-15
16-4-11
8-1-12
26-2-5
9-9-10
34-4-1
8-1-12
42-7-0
8-2-15
-1-0-0
1-0-0
5-6-6
5-6-6
10-11-9
5-5-2
16-4-11
5-5-2
21-3-8
4-10-13
26-2-5
4-10-13
31-7-7
5-5-2
37-0-10
5-5-2
42-7-0
5-6-6
43-7-0
1-0-0
0-6-14
11-6-0
0-6-14
11-6-0
8.00 12
Plate Offsets (X,Y): [2:0-0-12,Edge], [6:0-4-4,0-2-4], [8:0-4-4,0-2-4], [12:0-0-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.54
0.57
0.40
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.20
-0.58
0.16
0.09
(loc)
16-17
16-17
12
16-17
l/defl
>999
>872
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 211 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W4,W5: 2 X 4 SP No.2
WEDGE
Left: 2 X 4 SPF No.2, Right: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-3-13 oc purlins, except
2-0-0 oc purlins (4-7-1 max.): 6-8.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-17, 7-17, 7-16, 9-16
REACTIONS (lb/size) 2=1760/0-3-8 (min. 0-2-12), 12=1760/0-3-8 (min. 0-2-12)
Max Horz 2=262(LC 5)
Max Uplift 2=-92(LC 6), 12=-92(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2579/224, 3-4=-2408/226, 4-5=-2243/259, 5-6=-1929/285, 6-7=-1531/271, 7-8=-1531/271,
8-9=-1929/285, 9-10=-2243/259, 10-11=-2408/226, 11-12=-2579/224
BOT CHORD 2-19=-110/2032, 18-19=-67/1813, 17-18=-67/1813, 16-17=-9/1596, 15-16=-15/1813, 14-15=-15/1813,
12-14=-89/2032
WEBS 5-19=-19/391, 5-17=-496/173, 6-17=-62/729, 7-17=-310/196, 7-16=-310/196, 8-16=-62/729, 9-16=-496/173,
9-14=-20/391
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
TC
BC
WB
(Matrix)
0.03
0.02
0.01
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
4
5
4
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 13 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-7-12 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 2=111/3-6-6 (min. 0-1-8), 4=111/3-6-6 (min. 0-1-8), 6=102/3-6-6 (min. 0-1-8)
Max Horz 2=-44(LC 4)
Max Uplift 2=-24(LC 6), 4=-28(LC 7)
Max Grav 2=111(LC 1), 4=111(LC 1), 6=107(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0-4-7
0-1-8
8.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.03
0.03
0.03
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
10
11
10
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 47 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 12-5-0.
(lb) - Max Horz 2=-98(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 2, 16, 17, 18, 14, 13, 12
Max Grav All reactions 250 lb or less at joint(s) 2, 10, 15, 16, 17, 18, 14, 13, 12
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 16, 17, 18, 14, 13, 12.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.06
0.05
0.03
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
7
7
6
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 28 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 8-3-12.
(lb) - Max Horz 2=-66(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 2, 6, 10, 8
Max Grav All reactions 250 lb or less at joint(s) 2, 6, 9, 10, 8
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6, 10, 8.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
WB
(Matrix)
0.03
0.09
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
4
5
4
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-7-12 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 2=162/3-6-6 (min. 0-1-8), 4=162/3-6-6 (min. 0-1-8)
Max Horz 2=44(LC 5)
Max Uplift 2=-15(LC 6), 4=-15(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
TC
BC
WB
(Matrix)
0.21
0.25
0.13
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.02
0.04
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 36 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 2=277/12-5-0 (min. 0-1-10), 4=277/12-5-0 (min. 0-1-10), 6=495/12-5-0 (min. 0-1-10)
Max Horz 2=-98(LC 4)
Max Uplift 2=-41(LC 6), 4=-50(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-6=-287/53
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
BC
WB
(Matrix)
0.20
0.13
0.05
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.03
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 25 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 2=215/8-3-12 (min. 0-1-8), 4=215/8-3-12 (min. 0-1-8), 6=291/8-3-12 (min. 0-1-8)
Max Horz 2=66(LC 5)
Max Uplift 2=-44(LC 6), 4=-50(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
WB
(Matrix)
0.32
0.19
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.04
-0.12
0.00
0.05
(loc)
4-5
4-5
4
4-5
l/defl
>999
>564
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 26 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
W2: 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 5=304/0-3-8 (min. 0-1-8), 4=221/0-1-8 (min. 0-1-8)
Max Horz 5=237(LC 6)
Max Uplift 4=-128(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-5=-262/16
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=128.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.25
0.30
0.82
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.05
-0.15
0.02
0.13
(loc)
2-6
2-6
5
2-6
l/defl
>999
>979
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 38 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-5-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 7-4-1 oc bracing.
REACTIONS (lb/size) 5=470/0-3-8 (min. 0-1-8), 2=585/0-3-8 (min. 0-1-8)
Max Horz 2=114(LC 5)
Max Uplift 5=-144(LC 6), 2=-191(LC 4)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1011/649
BOT CHORD 2-6=-614/928, 5-6=-614/928
WEBS 3-6=-197/275, 3-5=-958/682
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=144, 2=191.
4) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
BC
WB
(Matrix)
0.07
0.08
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.00
-0.01
0.00
0.01
(loc)
2-4
2-4
4
2-4
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-10-4 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 2=188/0-3-8 (min. 0-1-8), 4=89/0-1-8 (min. 0-1-8)
Max Horz 2=68(LC 5)
Max Uplift 2=-63(LC 6), 4=-38(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
CSI
TC
BC
WB
(Matrix)
0.13
0.09
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.01
-0.02
0.00
0.01
(loc)
4-5
4-5
4
4-5
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 17 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
W2: 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 5=229/0-3-8 (min. 0-1-8), 4=139/0-1-8 (min. 0-1-8)
Max Horz 5=148(LC 5)
Max Uplift 5=-13(LC 6), 4=-68(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.05
-0.12
-0.00
0.00
(loc)
2-4
2-4
3
2
l/defl
>999
>540
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-6-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 3=151/Mechanical, 2=288/0-3-8 (min. 0-1-8), 4=53/Mechanical
Max Horz 2=138(LC 6)
Max Uplift 3=-89(LC 6), 2=-15(LC 6)
Max Grav 3=151(LC 1), 2=288(LC 1), 4=106(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
(Matrix)
0.07
0.04
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.00
-0.00
-0.00
0.00
(loc)
5
4-5
3
4-5
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 8 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-0-2 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 5=163/0-3-8 (min. 0-1-8), 3=37/Mechanical, 4=13/Mechanical
Max Horz 5=116(LC 6)
Max Uplift 3=-42(LC 6), 4=-8(LC 6)
Max Grav 5=163(LC 1), 3=37(LC 1), 4=32(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
TC
BC
WB
(Matrix)
0.10
0.08
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.01
-0.02
-0.00
0.00
(loc)
2-6
2-6
3
2
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-6-14 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 2=212/0-3-8 (min. 0-1-8), 3=89/Mechanical, 6=36/Mechanical
Max Horz 2=99(LC 6)
Max Uplift 2=-22(LC 6), 3=-58(LC 6)
Max Grav 2=212(LC 1), 3=89(LC 1), 6=72(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
TC
BC
WB
(Matrix)
0.10
0.08
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.01
-0.02
-0.00
0.00
(loc)
2-6
2-6
3
2
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-6-14 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 2=212/0-3-8 (min. 0-1-8), 3=89/Mechanical, 6=36/Mechanical
Max Horz 2=99(LC 6)
Max Uplift 2=-22(LC 6), 3=-58(LC 6)
Max Grav 2=212(LC 1), 3=89(LC 1), 6=72(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.03
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
0.00
-0.00
-0.00
0.00
(loc)
6
6
3
6
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 6 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 1-4-2 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 6=149/0-3-8 (min. 0-1-8), 5=2/Mechanical, 3=9/Mechanical
Max Horz 6=97(LC 6)
Max Uplift 6=-6(LC 6), 5=-12(LC 6), 3=-26(LC 6)
Max Grav 6=149(LC 1), 5=19(LC 2), 3=16(LC 4)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5, 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
0.03
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
0.00
-0.00
-0.00
0.00
(loc)
6
6
3
6
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 6 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 1-4-2 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 6=149/0-3-8 (min. 0-1-8), 5=2/Mechanical, 3=9/Mechanical
Max Horz 6=97(LC 6)
Max Uplift 6=-6(LC 6), 5=-12(LC 6), 3=-26(LC 6)
Max Grav 6=149(LC 1), 5=19(LC 2), 3=16(LC 4)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5, 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.16
0.10
0.12
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.00
-0.01
0.00
0.00
(loc)
6
6
5
6
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 34 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 6 SPF No.2
WEBS 2 X 4 SPF Stud *Except*
W1: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and
2-0-0 oc purlins: 3-4.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): 4
REACTIONS (lb/size) 5=386/Mechanical, 7=403/0-3-8 (min. 0-1-8)
Max Horz 7=131(LC 4)
Max Uplift 5=-129(LC 4), 7=-86(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-309/92, 2-7=-344/113
WEBS 3-5=-289/121
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end
vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb) 5=129.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 96 lb down and 133 lb up at 3-4-0, and 91 lb down and 88 lb
up at 4-0-12 on top chord, and 89 lb down at 3-4-0, and 66 lb down at 4-0-12 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20
Concentrated Loads (lb)
Vert: 6=-43(B) 3=-96(B) 8=-91(B) 9=-33(B)
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.54
0.47
0.83
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.04
-0.10
0.01
0.05
(loc)
7-8
7-8
6
7-8
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 188 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 10 SYP No.1
WEBS 2 X 4 SPF Stud
WEDGE
Left: 2 X 3 SPF No.2, Right: 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-7-11 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 6=5507/0-3-8 (min. 0-3-4), 2=3034/0-3-8 (min. 0-1-13)
Max Horz 2=164(LC 4)
Max Uplift 6=-857(LC 5), 2=-790(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3994/1095, 3-4=-3740/1112, 4-5=-4520/1123, 5-6=-4786/1099
BOT CHORD 2-8=-723/2564, 8-9=-505/2055, 7-9=-505/2055, 7-10=-670/3102, 10-11=-670/3102, 6-11=-670/3102
WEBS 4-7=-825/3859, 5-7=-141/346, 4-8=-800/1951, 3-8=-142/293
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 10 - 2 rows at 0-3-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end
vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=857, 2=790.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3277 lb down and 1359 lb up at 6-1-8, 1404 lb down and 75 lb
up at 8-0-12, and 1404 lb down and 75 lb up at 10-0-12, and 1404 lb down and 75 lb up at 12-0-12 on bottom chord. The design/selection of such connection
device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-4=-60, 4-6=-60, 2-6=-20
Concentrated Loads (lb)
Vert: 7=-1404(B) 9=-3277(B) 10=-1404(B) 11=-1404(B)
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
6
7
8
9
10
11
21 20 19 18 17 16 15 14 13 12
57 58 59 60 61 62
63 64 65 66 67 68
69 70
5x6
5x6
3x6
2x4
4x6
4x8 4x6 4x6
3x6
4x8
3x6
4x6
3x4
4x6
3x4
2x4
5x6
8x8
2x4
2x4
2x4 2x4
2x4 8x8
2x4 2x4 2x4 2x4 2x4
4x8
3-10-5
3-10-5
7-6-2
3-7-13
12-8-13
5-2-11
17-11-8
5-2-11
22-5-1
4-5-9
26-10-10
4-5-9
31-4-3
4-5-9
35-11-0
4-6-13
3-10-5
3-10-5
7-6-2
3-7-13
12-8-13
5-2-11
17-11-8
5-2-11
22-5-1
4-5-9
26-10-10
4-5-9
31-4-3
4-5-9
35-11-0
4-6-13
36-11-0
1-0-0
3-6-9
5-6-15
12-6-9
0-6-14
3.25 12
8.00 12
Plate Offsets (X,Y): [10:0-1-1,0-1-8], [13:0-2-8,0-2-0], [14:0-2-8,0-2-0], [15:0-4-0,0-4-8], [17:0-4-0,0-4-8], [18:0-2-8,0-2-0], [19:0-2-8,0-2-0], [20:0-2-8,0-2-0], [29:0-1-9,0-0-0],
[34:0-1-12,0-0-12], [37:0-1-11,0-0-0],
[54:0-1-14,0-0-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.21
0.54
0.71
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.10
-0.25
0.07
0.14
(loc)
14
14
10
16-18
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 548 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 6 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W9: 2 X 4 SP No.2, W1: 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-8-3 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 21=3297/Mechanical, 10=3009/0-3-8 (min. 0-2-6)
Max Horz 21=278(LC 4)
Max Uplift 21=-1333(LC 5), 10=-1013(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2680/1080, 2-3=-3782/1523, 3-4=-3748/1506, 4-5=-2964/1257, 5-6=-2944/1257, 6-7=-3608/1440,
7-8=-4211/1607, 8-9=-4282/1589, 9-10=-4800/1652, 1-21=-2981/1166
BOT CHORD 21-57=-256/214, 20-57=-256/214, 20-58=-1028/2559, 58-59=-1028/2559, 19-59=-1028/2559,
19-60=-1431/3639, 60-61=-1431/3639, 61-62=-1431/3639, 18-62=-1431/3639, 18-63=-1137/3059,
17-63=-1137/3059, 17-64=-1137/3059, 16-64=-1137/3059, 16-65=-1006/2939, 15-65=-1006/2939,
15-66=-1006/2939, 14-66=-1006/2939, 14-67=-1193/3504, 67-68=-1193/3504, 13-68=-1193/3504,
13-69=-1251/3818, 69-70=-1251/3818, 12-70=-1251/3818, 10-12=-1251/3818
WEBS 2-20=-1769/653, 2-19=-639/1654, 3-19=-727/230, 3-18=-826/414, 4-18=-594/1213, 4-16=-1310/657,
5-16=-1307/2906, 6-16=-1272/584, 6-14=-546/1239, 7-14=-969/395, 7-13=-328/892, 9-13=-405/114,
9-12=-68/412, 1-20=-1298/3334
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.
Webs connected as follows: 2 X 3 - 1 row at 0-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end
vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
6) All plates are 1.5x4 MT20 unless otherwise indicated.
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 21=1333, 10=1013.
11) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 201 lb down and 140 lb up at 0-1-12, 201 lb down and 140 lb
up at 2-4-4, 201 lb down and 140 lb up at 4-4-4, 201 lb down and 140 lb up at 6-4-4, 201 lb down and 140 lb up at 8-4-4, 201 lb down and 140 lb up at 10-4-4,
201 lb down and 140 lb up at 12-4-4, 201 lb down and 140 lb up at 14-4-4, 201 lb down and 140 lb up at 16-4-4, 201 lb down and 140 lb up at 18-4-4, 201 lb
down and 140 lb up at 20-4-4, 201 lb down and 140 lb up at 22-4-4, 201 lb down and 140 lb up at 24-4-4, 201 lb down and 140 lb up at 26-4-4, and 201 lb down
and 90 lb up at 28-4-4, and 366 lb down and 143 lb up at 30-4-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of
Continued others. on page 2
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.70
0.40
0.79
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.07
-0.18
0.03
0.05
(loc)
6-7
6-7
5
7-9
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 269 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 8 SYP DSS
WEBS 2 X 4 SPF Stud *Except*
W3: 2 X 4 SP No.2
WEDGE
Left: 2 X 12 SYP No.1, Right: 2 X 12 SYP No.1
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-5-13 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=5952/0-5-8 (min. 0-3-0), 5=6196/0-5-8 (min. 0-3-2)
Max Horz 1=-222(LC 3)
Max Uplift 1=-286(LC 6), 5=-303(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-6855/376, 2-3=-4679/351, 3-4=-4679/351, 4-5=-6887/378
BOT CHORD 1-10=-264/4475, 10-11=-264/4475, 9-11=-264/4475, 8-9=-264/4475, 8-12=-264/4475, 7-12=-264/4475,
7-13=-181/4498, 13-14=-181/4498, 6-14=-181/4498, 6-15=-181/4498, 15-16=-181/4498, 5-16=-181/4498
WEBS 3-7=-401/6217, 4-7=-1932/240, 4-6=-120/3050, 2-7=-1897/237, 2-9=-116/3001
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 8 - 2 rows at 0-7-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end
vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=286, 5=303.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1344 lb down and 68 lb up at 2-4-12, 1344 lb down and 68 lb
up at 4-4-12, 1344 lb down and 68 lb up at 6-4-12, 1344 lb down and 68 lb up at 8-4-12, 1344 lb down and 68 lb up at 10-4-12, 1344 lb down and 68 lb up at
12-4-12, and 1330 lb down and 61 lb up at 14-4-12, and 1327 lb down and 77 lb up at 16-4-12 on bottom chord. The design/selection of such connection
device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-5=-60, 1-5=-20
Concentrated Loads (lb)
Vert: 8=-1344(F) 10=-1344(F) 11=-1344(F) 12=-1344(F) 13=-1344(F) 14=-1344(F) 15=-1330(F) 16=-1327(F)
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
4-7-12
20-1-7
4-10-9
25-3-8
5-2-1
0-10-14
11-6-0
1-5-6
11-6-0
12.00 12
Plate Offsets (X,Y): [1:0-0-0,0-0-13], [3:0-4-4,0-1-12], [4:0-6-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.40
0.42
0.85
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.03
-0.06
0.01
0.02
(loc)
12
10-12
6
12
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 695 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 10 SYP No.1
WEBS 2 X 4 SP No.2 *Except*
W1,W7: 2 X 4 SPF Stud
SLIDER Right 2 X 8 SYP DSS 3-4-3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
2-0-0 oc purlins (10-0-0 max.): 3-4.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 9-10.
REACTIONS (lb/size) 1=4748/0-3-8 (min. 0-1-14), 6=941/0-3-8 (min. 0-1-8), 10=9377/0-3-8 (req. 0-3-11)
Max Horz 1=254(LC 4)
Max Uplift 1=-129(LC 6), 6=-133(LC 6), 10=-529(LC 5)
Max Grav 1=4767(LC 9), 6=964(LC 10), 10=9377(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-3649/106, 2-3=-56/1210, 3-4=0/903, 4-5=0/793, 5-6=-608/132
BOT CHORD 1-13=-213/2420, 13-14=-213/2420, 14-15=-213/2420, 12-15=-213/2420, 12-16=-213/2420, 16-17=-213/2420,
11-17=-213/2420, 11-18=-213/2420, 10-18=-213/2420, 10-19=-515/203, 9-19=-515/203, 9-20=-40/321,
20-21=-40/321, 8-21=-40/321, 7-8=-40/321, 7-22=-40/321, 6-22=-40/321
WEBS 2-12=-136/5934, 2-10=-4301/299, 3-10=-1074/106, 4-10=-1395/208, 4-9=-205/570, 5-9=-1243/287,
5-8=-131/1484
NOTES
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 10 - 2 rows at 0-4-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end
vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) WARNING: Required bearing size at joint(s) 10 greater than input bearing size.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=129, 6=133, 10=529.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1674 lb down and 68 lb up at 1-0-12, 1674 lb down and 68 lb
up at 3-0-12, 1674 lb down and 68 lb up at 5-0-12, 1671 lb down and 44 lb up at 5-11-12, 1671 lb down and 44 lb up at 7-11-12, 1671 lb down and 44 lb up at
9-11-12, 432 lb down and 56 lb up at 11-11-12, 432 lb down and 56 lb up at 13-11-12, 432 lb down and 56 lb up at 15-11-12, 432 lb down and 56 lb up at
17-11-12, 432 lb down and 56 lb up at 19-11-12, and 432 lb down and 56 lb up at 21-11-12, and 432 lb down and 56 lb up at 23-11-12 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-4=-60, 4-6=-60, 1-6=-20
Continued on page 2
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
3x6
3x4 2x4
2x4
1.5x4
2x4
2x4
2x4
3x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
2x4
2x4
1.5x4
1.5x4
2x4
1.5x4
1.5x4
1.5x4
2x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
5-4-13
5-4-13
10-7-2
5-2-5
11-9-4
1-2-2
15-2-14
3-5-10
20-1-15
4-11-1
25-3-8
5-1-9
-1-0-0
1-0-0
5-4-13
5-4-13
10-7-2
5-2-5
15-2-14
4-7-12
20-1-15
4-11-1
25-3-8
5-1-9
0-10-14
11-6-0
1-5-6
11-6-0
12.00 12
Plate Offsets (X,Y): [2:Edge,0-0-1], [5:0-6-4,0-1-12], [6:0-6-4,0-1-12], [22:0-0-4,0-1-8], [25:0-1-2,0-0-4], [32:0-1-12,0-0-12], [35:0-1-12,0-0-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.29
0.23
0.51
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.01
-0.03
0.00
0.01
(loc)
13-15
13-15
9
10-11
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 230 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 6 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W3,W4,W5: 2 X 4 SP No.2, W9: 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
SLIDER Left 2 X 6 SPF No.2 3-6-6
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and
2-0-0 oc purlins (10-0-0 max.): 5-6.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 12-13.
WEBS 1 Row at midpt 5-12, 6-12
REACTIONS (lb/size) 2=473/0-3-8 (min. 0-1-8), 12=1118/0-3-8 (min. 0-1-12), 9=481/0-3-8 (min. 0-1-8)
Max Horz 2=280(LC 4)
Max Uplift 2=-9(LC 5), 12=-88(LC 5)
Max Grav 2=491(LC 9), 12=1118(LC 1), 9=503(LC 10)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-457/28, 6-7=-254/123, 7-8=-485/34, 8-9=-457/23
BOT CHORD 2-16=-146/256, 15-16=-146/256, 14-15=-146/256, 13-14=-146/256, 10-11=0/278
WEBS 3-15=0/258, 3-13=-338/180, 5-12=-389/81, 6-12=-447/67, 6-11=-75/277, 7-11=-289/172
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end
vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.11
0.04
0.04
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.00
-0.00
-0.00
0.00
(loc)
6
6
5
7
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 25 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 6 SPF No.2
WEBS 2 X 4 SPF Stud *Except*
W1: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and
2-0-0 oc purlins: 3-4.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): 4
REACTIONS (lb/size) 5=192/Mechanical, 7=251/0-3-8 (min. 0-1-8)
Max Horz 7=111(LC 4)
Max Uplift 5=-80(LC 4), 7=-53(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end
vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 49 lb down and 92 lb up at 2-8-0 on top chord, and 65 lb down
at 2-8-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20
Concentrated Loads (lb)
Vert: 6=-29(F) 3=-49(F)
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
3
4
5
6 7 8
9
10
11
12
13
22 21 20
19 18 17 16
73 74 75 15 14
76 77 78 79 80 81 82
83 84 85 86 87 88
3x6
5x8
5x8
3x6
4x8
8x8
3x4
2x4 4x6
3x4
4x6 4x8 4x6
3x4
4x6
3x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4 2x4
2x4
2x4
2x4
2x4 2x4
2x4
4x8
4x8
5-6-6
5-6-6
10-11-9
5-5-2
16-4-11
5-5-2
21-3-8
4-10-13
26-2-5
4-10-13
31-7-7
5-5-2
37-0-10
5-5-2
42-7-0
5-6-6
-1-0-0
1-0-0
5-6-6
5-6-6
10-11-9
5-5-2
16-4-11
5-5-2
21-3-8
4-10-13
26-2-5
4-10-13
31-7-7
5-5-2
37-0-10
5-5-2
42-7-0
5-6-6
43-7-0
1-0-0
0-6-14
11-6-0
0-6-14
11-6-0
8.00 12
Plate Offsets (X,Y): [2:0-8-2,0-0-3], [6:0-6-4,0-2-4], [8:0-6-4,0-2-4], [12:0-8-2,0-0-3], [15:0-2-8,0-2-0], [21:0-2-8,0-2-0], [40:0-2-0,0-0-8], [49:0-1-13,0-0-4], [57:0-2-0,0-0-4], [66:0-1-13,0-0-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.23
0.42
0.41
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.10
-0.24
0.09
0.12
(loc)
19-21
19-21
12
19-21
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 735 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 6 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W5,W6: 2 X 4 SP No.2
OTHERS 2 X 3 SPF No.2 *Except*
ST10: 2 X 4 SP No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-9-2 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 6-8.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 2=2888/0-3-8 (min. 0-2-4), 12=2888/0-3-8 (min. 0-2-4)
Max Horz 2=-260(LC 3)
Max Uplift 2=-822(LC 5), 12=-822(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4566/1331, 3-4=-3968/1191, 4-5=-3881/1224, 5-6=-3325/1078, 6-7=-2851/961, 7-8=-2851/961,
8-9=-3325/1078, 9-10=-3881/1224, 10-11=-3968/1191, 11-12=-4566/1332
BOT CHORD 2-73=-1103/3637, 22-73=-1103/3637, 22-74=-1103/3637, 74-75=-1103/3637, 75-76=-1103/3637,
21-76=-1103/3637, 21-77=-970/3229, 20-77=-970/3229, 20-78=-970/3229, 19-78=-970/3229, 19-79=-797/2697,
79-80=-797/2697, 18-80=-797/2697, 18-81=-702/2697, 81-82=-702/2697, 17-82=-702/2697, 17-83=-830/3229,
16-83=-830/3229, 16-84=-830/3229, 15-84=-830/3229, 15-85=-986/3638, 85-86=-986/3638, 86-87=-986/3638,
14-87=-986/3638, 14-88=-986/3638, 12-88=-986/3638
WEBS 3-22=-122/427, 3-21=-510/217, 5-21=-289/751, 5-19=-920/402, 6-19=-466/1156, 6-18=-272/524,
7-18=-308/134, 8-18=-273/524, 8-17=-466/1156, 9-17=-920/402, 9-15=-289/751, 11-15=-510/218,
11-14=-123/427
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.
Webs connected as follows: 2 X 3 - 1 row at 0-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end
vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
6) Provide adequate drainage to prevent water ponding.
7) All plates are 1.5x4 MT20 unless otherwise indicated.
8) Gable studs spaced at 2-0-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=822, 12=822.
11) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
Continued on page 2
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 8 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-11-1 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 1=93/2-11-1 (min. 0-1-8), 3=93/2-11-1 (min. 0-1-8)
Max Horz 1=47(LC 5)
Max Uplift 3=-16(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Gable requires continuous bottom chord bearing.
4) Gable studs spaced at 2-0-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.24
0.16
0.06
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.05
0.00
(loc)
1
1
9
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 41 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 12-2-4.
(lb) - Max Horz 2=114(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 9, 2, 10, 11, 12, 14 except 13=-127(LC 1)
Max Grav All reactions 250 lb or less at joint(s) 9, 10, 11, 12, 13 except 2=285(LC 1), 14=494(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-14=-341/139
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Gable requires continuous bottom chord bearing.
4) Gable studs spaced at 1-4-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 2, 10, 11, 12, 14 except (jt=lb) 13=127.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
4x6
4x6
1.5x4
2x4
1.5x4
1.5x4
2x4
2x4
5x6
1.5x4
1.5x4
2x4
1.5x4
1.5x4
2x4
2x4
5x6
1.5x4
1.5x4
7-5-13
7-5-13
11-11-6
4-5-9
14-9-3
2-9-12
22-3-0
7-5-13
-1-0-0
1-0-0
5-8-0
5-8-0
11-1-8
5-5-8
16-7-0
5-5-8
22-3-0
5-8-0
23-3-0
1-0-0
0-10-14
12-0-6
0-10-14
12.00 12
Plate Offsets (X,Y): [2:0-5-15,Edge], [5:0-3-0,0-3-0], [6:0-1-8,0-1-8], [7:0-3-0,0-3-0], [10:0-5-15,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.27
0.24
0.46
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.06
-0.16
0.01
0.03
(loc)
2-17
2-17
10
2-17
l/defl
>999
>911
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 175 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SP No.2 *Except*
W1: 2 X 3 SPF No.2
OTHERS 2 X 3 SPF No.2 *Except*
ST5: 2 X 4 SP No.2
SLIDER Left 2 X 6 SPF No.2 4-1-1, Right 2 X 6 SPF No.2 4-1-1
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-13
REACTIONS All bearings 10-7-8 except (jt=length) 2=0-3-8, 15=0-3-8.
(lb) - Max Horz 2=273(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 2, 13, 10
Max Grav All reactions 250 lb or less at joint(s) 14, 12, 15 except 2=702(LC 1), 13=560(LC 1), 10=454(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-663/86, 3-4=-467/114, 4-5=-572/223, 5-6=-446/265, 6-7=-152/252, 7-8=-280/210, 8-9=-269/99,
9-10=-367/70
BOT CHORD 2-17=-120/396
WEBS 6-13=-286/52, 8-13=-295/249, 6-17=-173/423, 4-17=-287/246
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable studs spaced at 2-0-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 13, 10.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
1.5x4
1.5x4
12-7-0
12-7-0
-1-0-0
1-0-0
6-3-8
6-3-8
12-7-0
6-3-8
0-10-14
7-2-6
0-10-14
12.00 12
Plate Offsets (X,Y): [12:Edge,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.10
0.05
0.22
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
1
1
13
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 64 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 12-7-0.
(lb) - Max Horz 23=183(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 13, 19, 20, 21, 17, 16, 15 except 23=-120(LC 4), 22=-121(LC 5), 14=-115(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 23, 13, 18, 19, 20, 21, 22, 17, 16, 15, 14
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 19, 20, 21, 17, 16, 15 except (jt=lb) 23=120,
22=121, 14=115.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
10 9 8
5x8
4x8
4x8
3x4 4x10 3x6
3x4
3x4 4x8 5x6
5x6
3x4
4x6
2x4 2x4
3x6
7-6-2
7-6-2
16-4-11
8-10-9
23-4-2
6-11-7
30-3-9
6-11-7
33-11-8
3-7-15
7-6-2
7-6-2
11-11-6
4-5-5
16-4-11
4-5-5
23-4-2
6-11-7
30-3-9
6-11-7
33-11-8
3-7-15
3-6-9
5-6-15
11-6-0
9-0-11
11-6-0
3.25 12
8.00 12
Plate Offsets (X,Y): [4:0-5-12,0-2-0], [6:0-5-12,0-2-0], [7:0-3-0,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.69
0.64
0.66
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.16
-0.46
0.04
0.07
(loc)
12-14
12-14
8
12-14
l/defl
>999
>870
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 302 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W6,W7: 2 X 4 SP No.2, W1,W9: 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-2-10 oc purlins, except end verticals,
and 2-0-0 oc purlins (5-6-15 max.): 4-6.
BOT CHORD Structural wood sheathing directly applied or 9-11-7 oc bracing.
WEBS 1 Row at midpt 3-12, 4-10, 5-10, 6-10, 6-9, 7-8
REACTIONS (lb/size) 15=1347/0-3-8 (min. 0-2-2), 8=1347/0-3-8 (min. 0-2-2)
Max Horz 15=369(LC 5)
Max Uplift 15=-51(LC 6), 8=-77(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1615/178, 2-3=-1905/305, 3-4=-1306/253, 4-5=-901/234, 5-6=-901/234, 6-7=-534/200, 1-15=-1283/158,
7-8=-1323/158
BOT CHORD 14-15=-342/170, 13-14=-257/1256, 12-13=-257/1256, 11-12=-220/1031, 10-11=-220/1031, 9-10=-117/393
WEBS 2-14=-963/237, 3-14=-107/551, 3-12=-477/172, 4-12=-53/596, 4-10=-256/52, 5-10=-481/199, 6-10=-169/973,
6-9=-851/221, 1-14=-79/1584, 7-9=-142/1046
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 8.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
9-2-0
18-4-0
9-2-0
0-10-14
10-0-14
0-10-14
12.00 12
Plate Offsets (X,Y): [16:Edge,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.14
0.07
0.22
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
1
1
17
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 108 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 9-24, 8-25, 10-23
REACTIONS All bearings 18-4-0.
(lb) - Max Horz 32=250(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 25, 26, 27, 28, 30, 23, 22, 21, 20, 19 except 32=-153(LC 4), 17=-109(LC 5), 31=-153(LC
5), 18=-147(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 32, 17, 25, 26, 27, 28, 30, 31, 23, 22, 21, 20, 19, 18 except 24=251(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 9-24=-257/0
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 26, 27, 28, 30, 23, 22, 21, 20, 19 except
(jt=lb) 32=153, 17=109, 31=153, 18=147.
10) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
1
2
3
4
5
6 7 8
9
10
18
17
16 15
14
13 12 11
5x6
5x6
5x6
5x6
6x8
3x6
3x4
3x8
3x8
3x8
3x4
3x6
2x4
2x4
3x4
4x6
2x4
3x6
8-2-15
8-2-15
16-4-11
8-1-12
23-4-2
6-11-7
30-3-9
6-11-7
36-4-0
6-0-8
42-7-0
6-3-0
-1-0-0
1-0-0
5-6-6
5-6-6
10-11-9
5-5-2
16-4-11
5-5-2
23-4-2
6-11-7
30-3-9
6-11-7
36-4-0
6-0-8
42-7-0
6-3-0
0-6-14
11-6-0
3-3-11
11-6-0
8.00 12
Plate Offsets (X,Y): [2:0-0-12,Edge], [4:0-1-12,0-3-4], [6:0-4-4,0-2-4], [8:0-4-4,0-2-4], [12:0-2-8,0-1-8], [17:0-2-13,0-1-8], [18:0-0-10,0-2-0], [25:0-2-0,0-0-0], [59:0-1-12,0-0-12],
[62:0-1-12,0-0-12], [67:0-1-6,0-0-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.54
0.57
0.63
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.12
-0.37
0.13
0.08
(loc)
16-18
16-18
11
16
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 334 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2 *Except*
W4,W5: 2 X 4 SP No.2, W9: 2 X 4 SPF No.2
OTHERS 2 X 3 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-3-14 oc purlins, except end verticals,
and 2-0-0 oc purlins (4-2-10 max.): 6-8.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-16, 7-16, 7-13
REACTIONS (lb/size) 2=1761/0-3-8 (min. 0-2-12), 11=1691/Mechanical
Max Horz 2=304(LC 5)
Max Uplift 2=-92(LC 6), 11=-32(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2583/229, 3-4=-2412/231, 4-5=-2320/264, 5-6=-1926/293, 6-7=-1531/279, 7-8=-1330/266,
8-9=-1703/275, 9-10=-1619/190, 10-11=-1633/160
BOT CHORD 2-18=-219/2035, 17-18=-185/1813, 16-17=-185/1813, 15-16=-136/1612, 14-15=-136/1612, 13-14=-136/1612,
12-13=-14/1273
WEBS 5-18=-15/407, 5-16=-493/170, 6-16=-52/680, 7-16=-309/194, 7-15=0/266, 7-13=-632/165, 8-13=-38/547,
9-12=-501/101, 10-12=-49/1385
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11.
10) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
11-11-0
5-11-8
12-11-0
1-0-0
0-10-14
6-10-6
0-10-14
12.00 12
Plate Offsets (X,Y): [10:Edge,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
Yes
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.09
0.05
0.22
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
11
11
12
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 60 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 3 SPF No.2
OTHERS 2 X 3 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 11-11-0.
(lb) - Max Horz 20=162(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13
Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
WB
(Matrix)
0.15
0.13
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.02
-0.05
-0.00
0.00
(loc)
2-4
2-4
3
2-4
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 28 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 6 SPF No.2
BOT CHORD 2 X 6 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 3=156/Mechanical, 2=373/0-3-8 (min. 0-1-8), 4=63/Mechanical
Max Horz 2=139(LC 6)
Max Uplift 3=-116(LC 6), 2=-86(LC 6)
Max Grav 3=156(LC 1), 2=373(LC 1), 4=129(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 116 lb uplift at joint 3 and 86 lb uplift at joint 2.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 29 lb down and 69 lb up at 3-6-6, and 53 lb up at 3-6-9 on top
chord, and 32 lb down at 3-6-6, and 20 lb up at 3-6-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 2-4=-20
Concentrated Loads (lb)
Vert: 5=-6(F=23, B=-29) 6=-9(F=7, B=-16)
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
BC
WB
(Matrix)
0.09
0.07
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.01
-0.02
-0.00
0.00
(loc)
2-4
2-4
3
2-4
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 23 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 6 SPF No.2
BOT CHORD 2 X 6 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-9-1 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 3=109/Mechanical, 2=300/0-3-8 (min. 0-1-8), 4=49/Mechanical
Max Horz 2=118(LC 6)
Max Uplift 3=-92(LC 6), 2=-84(LC 6)
Max Grav 3=109(LC 1), 2=300(LC 1), 4=105(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 92 lb uplift at joint 3 and 84 lb uplift at joint 2.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 51 lb up at 2-4-2, and 29 lb down and 69 lb up at 3-6-6 on top
chord, and 24 lb up at 2-4-2, and 32 lb down at 3-6-6 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 2-4=-20
Concentrated Loads (lb)
Vert: 5=51(B) 6=-29(F) 7=18(B) 8=-16(F)
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012
BC
WB
(Matrix)
0.09
0.07
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.01
-0.02
-0.00
0.00
(loc)
2-4
2-4
3
2-4
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 23 lb FT = 20%
GRIP
197/144
LUMBER
TOP CHORD 2 X 6 SPF No.2
BOT CHORD 2 X 6 SPF No.2
WEDGE
Left: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-9-1 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 3=109/Mechanical, 2=300/0-3-8 (min. 0-1-8), 4=49/Mechanical
Max Horz 2=118(LC 6)
Max Uplift 3=-92(LC 6), 2=-84(LC 6)
Max Grav 3=109(LC 1), 2=300(LC 1), 4=105(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=20ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 92 lb uplift at joint 3 and 84 lb uplift at joint 2.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 51 lb up at 2-4-2, and 29 lb down and 69 lb up at 3-6-6 on top
chord, and 24 lb up at 2-4-2, and 32 lb down at 3-6-6 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 2-4=-20
Concentrated Loads (lb)
Vert: 5=51(F) 6=-29(B) 7=18(F) 8=-16(B)
WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design
valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability
of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint
designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/
diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure
is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage,
delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from
SBCA at www.sbcindustry.com.
May 2,2012