Loading...
HomeMy WebLinkAboutA1.5 Reflected Ceiling Plan.PDF Project Number: Revisions: Issue Date Drawn By Checked By James Robert Stutzman, AIA, NCARB Architecture /Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: MATT THE MILLER'S Carmel, Indiana 46032 Carmel City Center -Suite 101 11 W. City Center Drive COPYRIGHT & OWNERSHIP OF DOCUMENTS N DN M MM MM M M M M M M M MM M M M M MM M M MMM M MM TRASH DISP. DA3Mtr Rm 1A-2 (A148) Stair SA4 Elev EA12 Stair SA3 Elev EA6 Stair SA5 Stair SA1 Elev EA9 Elev EA8 Elev EA1 Stair SA2 Stair SA6 Elev EA11 ELEV EA4 ELEV EA5 Elev EA3 Elev EA2 Elev EA7 Elev EA10 KEY PLAN SUITE 101 Monday, March 26, 2012; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A INTERIORS:TENANTS:MATT THE MILLER:Drawings:IBASE.pln PEDCOR DESIGN GROUP, L.L.C. A1.5 Reflected Ceiling Plan 03/26/2012 LES MC STATE RELEASE SET: 03/26/2012 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, 2010, 2011,2012 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA N 1'-3" 15'-7 1/2" 1'-3" 1'-2 3/4" 16'-0" 1'-2 1/2" 3'-5" 6'-0" 1'-0" 2'-0" 1'-0 3/8" 6'-0" 1'-0 3/8" 4'-6" 2'-4 5/8" 4'-0" 4'-6" 3'-1 3/8" 4'-6" 4'-6" 4'-6" 2'-1 3/4" 4'-8 1/2" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 2'-9 7/8" 5'-0" 11'-9 7/8" 5'-0" 2'-7 5/8" 12'-7 5/8" 3'-3" 6'-1 5/8" 6'-1" 5'-6 7/8" 1'-7 3/4" 6'-1" 6'-1" 6'-1" 6'-1" 3'-10 1/2" 11'-6 3/8" 4 7/8" 9 1/4" 1'-3" 12'-4 3/8" 1'-3" 1'-7 1/2" 10'-0" 1'-7 1/2" 2'-0" 1'-0 1/2" 12'-0" 1'-0 1/2" 1'-2 1/2" 16'-0" 2'-7 1/2" 8'-0" 1'-6" 4'-8 1/4" 2'-0" 11 1/2" 16'-0" 11 1/2" 2'-0" 1'-0" 16'-0" 1'-0" 2'-0" 1'-11 3/8" 4'-4" 4'-4" 4'-5 5/8" 4'-5 5/8" 4'-5 5/8" 4'-5 5/8" 4'-5 5/8" 5'-9 5/8" 1'-11 3/8" 4'-4" 4'-4" 4'-1 7/8" 4'-10 7/8" 4'-10 7/8" 4'-1 7/8" 2'-9 3/8" 7'-1 3/8" 11'-3 3/8" 4'-11 1/2" 2'-0" 18'-0" 2'-0" 18'-0" 2'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-6" 12'-6" 11'-9" 11'-9" 11'-9" 11'-9" 11'-9" 11'-9" 11'-4" 11'-4" 11'-4" 11'-4" 11'-4" 11'-4" 11'-4" 11'-4" 11'-4" 11'-4" 12'-6" 11'-4" 14'-0" 14'-0" OPEN OPEN OPEN OPEN OPEN OPEN 9'-9" 9'-9" 9'-9" 9'-9" 10'-2" OPEN 10'-2" 12'-0" OPEN 10'-0" 10'-0" 10'-0" 10'-0" 12'-0" R 4'-0" 5 A4.9 6 A4.9 8 A4.9 3 A4.9 5 A4.9 8 8 A4.9 8 A4.9 6 A4.9 6 A4.9 2 3 A4.9 A4.9 4 A4.9 5 A4.9 7 A4.9 1 A4.10 9 A4.9 2 A4.10 3 A4.10 5 A4.10 5 A4.10 9 A4.10 CP5 CP6 CP6 CP6 CP7 CP7 CP7 CP7 CP8 CP8 CP8 CP8 CP8 CP9 CP9 CP9 CP10 CP11 CP11 CP11 CP11 CP11 CP11 CP11 CP11 CP12 CP12 CP12 CP12 CP12 CP12 CP12 CP12 CP14 CP14 CP14 CP2 CP15 CP15 CP2 CP2 CP6 CP8 CP22 CP22 CP22 CP22 CP22 CP11 CP23 CP23 CP21 CP4 CP17 CP17 CP17 CP17 CP17 CP17 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP4 CP14 CP16 CP1 CP16 CP6 CP8 CP11 CP18 CP17 CP14 CP14 CP22 CP19 CP20 CP20 CP25 CP24 CP24 CP24 CP7 CP24 CP3 CP26 CP5 CP27 G G A BB C C C F F FF H H H H H HH HH H H HHHHH H H K K K K K K K K K K KK K K K K K K K KK K K K K K K K K K K K K P1 P1 P1 P1 P9 P2 P2 P2 P2 P2 P3 P3 P3 P3 P3 P3 P3 P3 P3 D D D DD DD D A A A AA A A A C P9 P9 P9 P9 P9 P9 P9 P9 P P P P N N NN SIM. SIM. SIM. SIM. SIM. SIM. SIM. LLL L L L LL L L LL LL E QQQQ QQ Q Q Q Q Q TYP. D TYP. ST1 ST1 ST1 ST1 ST1 ST1 ST1 K P D D D M M M M M M M M MM MM MM N JJ JJ JJ JJ JJ JJ JJ P9 L L L N N N EE EE Q Q D M M M M M M M M TRASH DISP. DA3 Mtr Rm 1A-2 (A148) 14'-0" 1 A4.9 4 A4.10 8 A4.10 CP13 CP13 CP13 CP13 CP13 CP13 CP4 CP13 CP17 DD P P.5 Q Q.5 R R.5 28 27.5 27 26.5 26 25 ACCESS PANELS ARE TO BE PROVIDED IN NON-ACCESSIBLE CEILINGS AS NEEDED AND AT EXISTING EXTERIOR JUNCTION BOXES AND AT PCU ACCESS POINTS. PANELS ARE TO BE PAINTED TO MATCH THE ADJACENT CEILING SURFACE. COORDINATE LOCATION OF ACCESS PANELS WITH THE ARCHITECT. ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. GENERAL CEILING NOTES: CEILING PLAN NOTES: PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. EMERGENCY STROBES ARE TO BE WHITE AND LIGHT FIXTURES ARE TO BE BLACK UNLESS NOTED OTHERWISE. COORDINATE IN THE FIELD WITH THE ARCHITECT AND TENANT. INSTALL ACOUSTICAL CEILING PANELS WITH GRAIN/TEXTURE RUNNING IN THE SAME DIRECTION UNLESS NOTED OTHERWISE. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. COORDINATE ALL SWITCHING AND LOCATIONS WITH THE TENANT AND ARCHITECT. LIGHTING TIMER IS TO BE PROVIDED TO MEETING ENERGY CODE. LARGER TIMING PANEL MAY BE REQUIRED. SWITCHES ARE TO BE BLACK CONFIRM ALL LOCATIONS AND COLORS WITH THE TENANT AND THE ARCHITECT IN THE FIELD. CP1 11. 10. 9. 8. 7. 4. 5. 6. 3. 1. 2. HVAC DIFFUSERS AND GRILLES, FIRE SPRINKLERS ARE TO BE CENTERED WITHIN CEILING TILES. REFLECTED CEILING LEGEND: ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE SHEET A1.2 FOR OTHER WALL TYPE INFORMATION. SEE M-SERIES, E-SERIES, AND P-SERIES SHEETS FOR MEP CONSULTANTS DRAWINGS. ALL QUESTIONS OR DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING CONTRACTOR IS TO VERIFY THERMOSTAT LOCATIONS WITH TENANT BEFORE PROCEEDING. LOCATE NEW SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM ARCHITECT AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICES. DEVICES. CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE. HEIGHTS ARE NOTED ABOVE +2'-0" (TENANT CONCRETE SLAB). CP2 CP8 PROVIDE AND INSTALL TIMER CONTROL SYSTEM AT THIS LOCATION. ALL LIGHTS NOT CONTROLLED WITH OCCUPANCY SENSORS ARE TO BE CONTROLLED ON THE TIMER. COORDINATE CIRCUITS AND SWITCHING WITH THE ARCHITECT. PROVIDE OPEN CEILING, ALL EXPOSED SURFACES TO BE PAINTED P2. PROVIDE SPIRAL DUCT, HARD PIPE CONDUIT FOR ALL WIRING, AND ALIGNMENT OF ALL VISIBLE ITEMS. PROVIDE & INSTALL TYPE 1 EXHAUST HOOD W/FIRE-SUPPRESSION, LIGHTING, MAKE-UP AIR, AND FAN. COORDINATED WITH MEP CONSULTANTS. CP5 PROVIDE ELECTRICAL FOR CEILING SPEAKERS AND ALARM SYSTEM. LOCATIONS FOR CAMERAS ARE TO BE DETERMINED WITH THE TENANT ONCE A PROVIDER IS DETERMINED. SPEAKERS FOR THE DINING AREA ARE TO BE CONTROLLED AT THE HOSTESS STAND. SPEAKERS FOR THE PRIVATE DINING AREA ARE TO BE CONTROLLED IN THAT ROOM. SPEAKERS FOR THE BAR DINING AREA, AND RESTROOMS ARE TO BE CONTROLLED IN THE BACK BAR. CP4 12. EXISTING HVAC UNITS ARE TO REMOVED AND RETURNED TO THE OWNER. CP9 PROVIDE 2'x2' SUSPENDED ACOUSTICAL CEILING TO BE ACT1. CP12 PROVIDE PAINTED DRYWALL CEILING WITH DOWNLIGHTS. SEE PLAN FOR PAINT COLORS AND LIGHTING LOCATIONS. CP13 SPRINKLER HEADS AND LINES ARE TO BE RAISED AS NEEDED TO MAINTAIN DESIRED CEILING HEIGHTS. CP6 PROVIDE WINDOW BLINDS IN STOREFRONT. BLINDS TO BE: HUNTER DOUGLAS -2" CHALET WOOD BLINDS -HAVANA. INSTALLER IS TO FIELD MEASURE STOREFRONT. BLINDS ARE TO EXTEND TO THE WAINSCOT LEDGE. BLINDS ARE TO BE PROVIDED BY THE TENANT. ALARM SYSTEM, TELEVISIONS AND SOUND SYSTEM ARE TO BE COORDINATED WITH THE PROVIDER. SPEAKERS ARE TO BE LOCATED IN THE BAR DINING, DINING, PRIVATE DINING, RESTROOMS AND ON THE PATIO. THERE ARE TO BE (6) SPEAKERS IN THE BAR DINING AREA. SPEAKERS IN THE BAR DINING, PRIVATE DINING AND RESTROOMS ARE TO BE MOUNTED IN THE CEILINGS. THE SPEAKERS IN THE DINING AREA ARE TO BE MOUNTED ABOVE THE CEILING CLOUDS AND DIRECTED DOWN IN THE SPACES BETWEEN CLOUDS AND BULKHEADS. CONSTRUCTION MANAGER TO PROVIDE PRICING FROM (2) DIFFERENT CONTRACTORS FOR EACH OF THESE ITEMS FOR THE TENANT TO REVIEW AND SELECT A PROVIDER. 13. 14. BLOCKING IS TO BE PROVIDED FOR ALL CEILING MOUNTED FIXTURES AS NEEDED. EMERGENCY NIGHT LIGHTS. PROVIDE EMERGENCY LIGHTS AS REQUIRED AND DETERMINED BY MEP CONSULTANT. FIXTURES ARE TO BE BLACK. LIGHTING CONTROL. GYPSUM BOARD CEILING TO BE PAINTED. SEE FINISH SCHEDULE FOR PAINT SELECTIONS. INDICATION DUAL-LITE TO BE: MERCURY LIGHTING MER-ELXTE OR EQUAL. EXIT SIGNS ARE TO BE BLACK. CEILING MOUNTED EXIT LIGHT W/DIRECTION 2' X 4' FLUORESCENT FIXTURE TO BE: LIGHTOLIER -XP2GVA332. LESS EXPENSIVE OR EQUAL ALTERNATE IS TO BE SUBMITTED. 2' X 2' SUSPENDED CEILING TO BE ACT1/ACT2 OR ACT3. G RECESSED DOWN LIGHT WITH SLOT APETURE TO BE: LIGHTOLIER -302MRX/309BKX OR EQUAL. LIGHT FIXTURES ARE TO BE DIMMABLE. 1' X 4' CHAIN HUNG LIGHT FIXTURE TO BE: LIGHTOLIER -WA4A232. LESS EXPENSIVE OR EQUAL ALTERNATE IS TO BE SUBMITTED. FIXTURE TO BE MOUNTED AT 14'-0" AFF. IN THE MECH. RM. LIGHT FIXTURES IN THE COOLERS ARE TO BE MOUNTED HIGH TO THE DECK. E J DECORATIVE DOWNLIGHT FIXTURE TO BE: JUNO -TC1-4103 FROST -SC. LIGHT FIXTURES ARE TO BE DIMMABLE. CEILING FAN TO BE: FANIMATION -LOUVRE -FP1320PW-B6030MH. LESS EXPENSIVE OR EQUAL ALTERNATE IS TO BE SUBMITTED. FAN IS TO HAVE 6" DOWNROD. MONOPOINT TRACK HEAD LIGHTING TO BE: LIGHTOLIER -6190BK MONOPOINT WITH 6074BK EXTENSION AND 6275BBK HEAD. LIGHT FIXTURE IS TO BE DIMMABLE. FIXTURES ARE TO BE MOUNTED AT 11'-9" TO THE BOTTOM OF THE TRACK HEAD. L EXHAUST GRILLE IN CEILING FOR USE WITH BUILDING'S EXHAUST SYSTEM. D H RECESSED DOWN LIGHT TO BE: LIGHTOLIER -302MRX/313BKX OR EQUAL. LIGHT FIXTURES ARE TO BE DIMMABLE. K DECORATIVE DOWNLIGHT FIXTURE TO BE: JUNO -IC1-4150 FROST -SC. LIGHT FIXTURES ARE TO BE DIMMABLE. TRACK HEAD TO BE: LIGHTOLIER -6190BK MONOPOINT WITH 6275BBK HEAD. ATTACHED HEAD TO ACOUSTICAL CEILING OR BULKHEAD AS INDICATED ON PLAN. LIGHT FIXTURES ARE TO BE DIMMABLE. M CHANDELIER LIGHT FIXTURE IS TO BE: CUSTOM SHADE WITH (1) FIXTURE WITH (2) 60W A INCANDESCENT LAMPS. LIGHT FIXTURES ARE TO BE DIMMABLE. SEE DETAIL 2/A1.5. CHANDELIER LIGHT FIXTURE IS TO BE: CUSTOM SHADE WITH (2) FIXTURES WITH (2) 60W INCANDESCENT LAMPS IN EACH. LIGHT FIXTURES ARE TO BE DIMMABLE. SEE B DETAIL 3/A1.5. CHANDELIER LIGHT FIXTURE IS TO BE: CUSTOM SHADE WITH (1) FIXTURE WITH (2) 60W INCANDESCENT LAMPS. LIGHT FIXTURES ARE TO BE DIMMABLE. LIGHT FIXTURE IS TO BE 2700 K LIGHT TEMPERATURE. SEE DETAIL 4/A1.5. HEIGHTS OF FIXTURE ARE TO VARY BASED ON LOCATION. CABLES ARE TO BE FIELD ADJUSTABLE. CONFIRM HEIGHTS IN THE FIELD WITH THE TENANT. C RESTROOM WALL SCONCES LIGHT FIXTURE IS TO BE: ROBERT ABBEY -111X. LIGHT F FIXTURE IS TO BE DIMMABLE. SEE ELEVATIONS ON A4.1 FOR LOCATION OF SCONCES. INTERIOR GOOSENECK LIGHT FIXTURE IS TO BE: JUNO/ALFA -WA213-STN OR STONE LIGHTING PLARC200SNR. MOUNT THE CANOPY 6" ABOVE THE FRAMED ARTWORK OR CHALKBOARD. CONFIRM LOCATIONS OF ARTWORK AND CHALKBOARD LOCATIONS WITH THE TENANT. N PUCK LIGHT FIXTURES IN CASEWORK (QTY: 15). ADDITIONAL STRIP LIGHT FIXTURES IN ACCENT COLUMNS TO BE: SISTEMALUX -ST128 (QTY: 17). SEE CASEWORK DETAILS ON SHEET A4.11. SEE NOTE (CP25) FOR ALTERNATE. P EXTERIOR SIGN LIGHT IS TO BE: HI-LITE -HL-H/91 WITH H-18110/91. LIGHT FIXTURE IS TO BE CONTROLLED ON TIMER. LIGHT FIXTURE HEIGHT IS TO BE COORDINATED WITH THE ARCHITECT. Q FIRE PROOFING IS TO BE REMOVED FROM THE DECK AND OTHER ITEMS IN OPEN CEILING AREAS THAT ARE NOT NEEDED TO BE FORE PROOFED. 15. CEILING FINISHES: P1 PAINT -SHERWIN WILLIAMS -SW7532 URBAN PUTTY P2 PAINT -SHERWIN WILLIAMS -SW7510 CHATEAU BROWN P3 PAINT -SHERWIN WILLIAMS -SW2803 ROOKWOOD TERRA COTTA DIMMERS FOR THE SPACE ARE TO BE INSTALLED AT MULTIPLE LOCATIONS BASED ON WHAT LIGHT FIXTURES THE DIMMER CONTROLS. LOCATIONS OF DIMMERS ARE TO BE DETERMINED IN THE FIELD. DIMMER AND SWITCH COLORS ARE TO BE BLACK. THE TENANT IS TO DETERMINE WHAT LIGHT FIXTURES ARE CONTROLLED TOGETHER. CP3 LOCATION OF SWITCHES AND DIMMERS TO CONTROL FIXTURE 'K' AND 'J' IN THE BAR DINING, FIXTURE 'M' AND 'P' IN THE BAR, FIXTURE 'N', FIXTURE 'Q' FOR AWNINGS AND SIGNAGE SIGNAGE LIGHTING. FANS ARE TO BE CONTROLLED AT THIS LOCATION. CONFIRM WITH THE TENANT. CP10 PROVIDE 2'x2' SUSPENDED ACOUSTICAL CEILING TO BE ACT2. CP11 PROVIDE 2'x2' SUSPENDED ACOUSTICAL CEILING TO BE ACT3. CP7 PROVIDE EXHAUST GRILLE IN RESTROOMS AND MECHANICAL ROOM. CONNECT EXHAUST TO BUILDING SYSTEM. CP14 PROVIDE CUSTOM WOOD CEILING. SEE DETAILS 6/A4.9. FIVE PERCENT (5%) ATTIC STOCK IS TO BE PROVIDE TO THE TENANT FOR ALL CEILING TILES. THESE ARE TO BE PROVIDED TO THE TENANT IN UNOPENED BOXES. 16. 17. HVAC DIFFUSERS AND GRILLES ARE TO BE PAINTED TO MATCH THE ADJACENT CEILING. PROVIDE ELECTRICAL FOR TENANT PROVIDED BACKLIT EXTERIOR SIGNAGE. SEE ELEVATIONS ON A2.1. CP15 CP16 PROVIDE ELECTRICAL FOR EXTERIOR GOOSENECK SIGNAGE LIGHT FIXTURES. WOOD SLAT CEILING ATTACHED TO DRYWALL BULKHEAD. WOOD TO BE ST1. SEE SECTION 6/A4.9. PROVIDE STRUCTURAL STEEL BRACING AND BLOCKING ABOVE THE CEILING CLOUDS AS NEEDED TO SUPPORT THE WEIGHT OF THE CUSTOM CHANDELIER LIGHT FIXTURES 'A', 'B' & 'C'. CP17 PROVIDE ELECTRICAL FOR TENANT PROVIDED SECURITY SYSTEM. COORDINATE WITH THE TENANT THE EXACT LOCATIONS OF CAMERAS. CP18 CONFIRM HEIGHTS OF CEILING IN THE PRIVATE DINING WITH THE TENANT PRIOR TO CONSTRUCTION. CP19 INSIDE THE COOLERS ARE TO BE SPRINKLERED. THE OPEN SPACE ABOVE EACH COOLER IS TO BE SPRINKLERED AS WELL. CP20 18. CONTROL JOINTS ARE TO BE PLACED IN DRYWALL CEILINGS AS NEEDED. SEE DETAIL 15/A3.1. 19. CP21 PROVIDE EXHAUST HOOD FOR DISHWASHER. COORDINATE WITH MEP CONSULTANTS. CP22 PROVIDE AWNINGS. SEE DETAILS ON SHEETS A2.2 AND A2.3. CP23 ADJUST EXISTING EMERGENCY EXIT SIGN ARROWS BASED ON THE REVISED EGRESS PATHS. P9 PAINT -SHERWIN WILLIAMS -CUSTOM COLOR. CEILING CLOUD SUPPORTS FOR ALL ACOUSTICAL CLOUDS IN THE DINING AREA ARE NOT TO BE VISIBLE. 20. A COORDINATION MEETING IS TO TAKE PLACE TO DETERMINE WHAT LIGHT FIXTURES ARE TO BE CONTROLLED TOGETHER. PRIVATE DINING FIXTURES ARE TO BE CONTROLLED IN THE ROOM. VESTIBULE, WAITING AND DINING FIXTURES ARE TO BE CONTROLLED AT THE HOSTESS STAND. BAR, RESTROOMS AND BAR DINING ARE TO TO BE CONTROLLED FROM THE BACK BAR. 21. PROVIDE APPROPRIATE HVAC NEEDS IN OFFICE. OFFICE TO HOUSE WINE AND LIQUOR STORAGE, TELEVISION CABLE BOXES AND LIGHTING, MUSIC, AND SECURITY SYSTEM CONTROLS. COORDINATE WITH MEP CONSULTANT. 22. MEP CONSULTANT TO RUN THE NECESSARY CALCULATIONS TO DETERMINE THAT THE LIGHTING LAYOUT MEETS THE ENERGY CODE. IF IT DOES NOT PLEASE ADDRESS THIS WITH THE ARCHITECT AND THE TENANT TO REVISE LIGHT SELECTIONS AS NEEDED. 23. MEP CONSULTANT IS TO SUBMIT DRAWINGS SHOWING LOCATIONS OF ALL NECESSARY HORN STROBES, FIRE PULLS AND EMERGENCY LIGHTS. LOCATION OF FOUR (4) SECURITY CAMERAS. LOCATION ARE TO BE CONFIRMED IN THE FIELD WITH THE TENANT. CP24 PROVIDE ALTERNATE FOR STRIP LIGHT LOCATIONS (QTY: 17) IN BACK BAR CASEWORK TO BE: LED STRIP. CP25 LOCATION FOR DIMMERS AND SWITCHES FOR LIGHT FIXTURE 'K' IN THE VESTIBULE AND ENTRY, FIXTURE 'A', 'B', 'C', 'H' AND 'L' IN THE MAIN DINING AREA. CONFIRM LIGHTING CONTROLS WITH THE TENANT PRIOR TO CONSTRUCTION. CP26 REMOVE EXISTING DROP-IN CEILING AND PROVIDE NEW CFS FRAMED CEILING AND EXTERIOR FINISH SYSTEM TO MATCH EXISTING EIFS FINISH. PROVIDE ACCESS PANEL (30"X24") WITH SAME FINISH. CP27 5 A1.5 2'-6" 3'-2" 4'-0" 2'-6" 3'-2" 4'-0" 10 5/8" 7 3/8" 1'-6" 1" STEEL BAND POWDERED COATED BLACK. TYP. 1/8" WHITE ACRYLIC (ACR1). 18" X 18" X 1/2" STEEL PLATE WELDED TO TUBES. 1" TUBE POWDER COATED BLACK. TYP. 18" X 18" X 1/2" STEEL PLATE WELDED TO TUBES. 1" TUBE POWDER COATED BLACK. TYP. 1" STEEL BAND POWDERED COATED BLACK. TYP. 1/8" WHITE ACRYLIC. LIGHT FIXTURE 'A' 5 A1.5 6'-6" 7'-2" 8'-0" 2'-6" 3'-2" 4'-0" 10 5/8" 7 3/8" 2'-2" 2'-2" 2'-2" 1'-6" 1" STEEL BAND POWDERED COATED BLACK. TYP. 1/8" WHITE ACRYLIC (ACR1). 18" X 18" X 1/2" STEEL PLATE WELDED TO TUBES. 1" TUBE POWDER COATED BLACK. TYP. 18" X 18" X 1/2" STEEL PLATE WELDED TO TUBES. TYP. 1" TUBE POWDER COATED BLACK. TYP. 1" STEEL BAND POWDERED COATED BLACK. TYP. 1/8" WHITE ACRYLIC. LIGHT FIXTURE 'B' 4" 2" 9" 2" 1'-1" 1'-5" 1/8" FORMED WHITE ACRYLIC PANEL (ACR1). 2" METAL BAND POWDER COATED BLACK. CONNECT WITH (4) 1" VERTICAL BANDS. METAL STAR POWDER COATED BLACK. METAL STAR POWDER COATED BLACK. 2" METAL BAND POWDER COATED BLACK. CONNECT WITH (4) 1" VERTICAL BANDS. CABLE SUSPENSION. LIGHT FIXTURE 'C' 1" 1" 8 5/8" 1" 1" 1" 5" R 1'-0" 1/8" WHITE ACRYLIC. 48" x 48" REMOVABLE STEEL TOP PLATE. 1" STEEL BAND POWDER COATED BLACK, TYPICAL. 1/8" FORMED WHITE ACRYLIC. SCALE: 3/16" = 1'-0" 1 Reflected Ceiling Plan A1.5 SCALE: 3/4" = 1'-0" 2 Light Fixture Details A1.5 SCALE: 3/4" = 1'-0" 3 Light Fixture Details A1.5 SCALE: 3/4" = 1'-0" 4 Light Fixture Details A1.5 SCALE: 1 1/2"= 1'-0" 5 Light Fixture Edge Detail A1.5