Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LS.2 Life Safety Plan.PDF
Project Number: Revisions: Issue Date Drawn By Checked By James Robert Stutzman, AIA, NCARB Architecture /Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: MATT THE MILLER'S Carmel, Indiana 46032 Carmel City Center -Suite 101 11 W. City Center Drive COPYRIGHT & OWNERSHIP OF DOCUMENTS N DN M MM MM M M M M M M M MM M M M M MM M M MMM M MM TRASH DISP. DA3Mtr Rm 1A-2 (A148) Stair SA4 Elev EA12 Stair SA3 Elev EA6 Stair SA5 Stair SA1 Elev EA9 Elev EA8 Elev EA1 Stair SA2 Stair SA6 Elev EA11 ELEV EA4 ELEV EA5 Elev EA3 Elev EA2 Elev EA7 Elev EA10 KEY PLAN SUITE 101 Friday, March 23, 2012; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A INTERIORS:TENANTS:MATT THE MILLER:Drawings:IBASE.pln PEDCOR DESIGN GROUP, L.L.C. LS.2 Life Safety Plan 03/26/2012 LES MC STATE RELEASE SET: 03/26/2012 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, 2010, 2011,2012 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA N 2'-11" 2'-11" 2'-11" 3'-2" WH VESTIBULE 100 66'-6" MATT THE MILLER'S TAVERN TOTAL: 5,517 SQUARE FEET DINING: 4,056 SQ. FT. @15 SQ. FT. PER PERSON = 270 OCCUPANTS KITCHEN: 1,461 SQ. FT. @200 SQ. FT. PER PERSON = 7 OCCUPANTS BUSINESS: 85 SQ. FT @100 SQ.FT. PER PERSON = 1 OCCUPANT TOTAL = 278 OCCUPANTS 84'-10" 56'-11" 53'-5" WAITING 101 BAR DINING 113 BAR 114 OFFICE 116 COOLER 115 DINING 109 DINING 102 KITCHEN 104 COOLER 105 MECH. 106 DISH AREA 107 WOMENS 112 MENS 111 HALL 110HALL 108 10'-7" 21'-2" EXIT EXIT 38'-7" M M M M M M M M TRASH DISP. DA3 Mtr Rm 1A-2 (A148) Stair SA3 PRIVATE DINING 103 76'-4" MAINTAIN REQUIRED EGRESS WIDTH SERVICE CORRIDOR MATT THE MILLER'S TAVERN RESTAURANT LIFE SAFETY & CODE SUMMARY PROJECT SUMMARY This project is a new tenant improvement project known as the Matt the Miller's Tavern, occupying 5,517 square feet of the ground floor of an existing Shell and Core project known as Carmel City Center. The Matt the Miller's project occupies approximately nine percent (9%) of the ground floor area of a seven (7) story building. Beneath the ground floor and separated with a 3-hour fire resistive assembly, is an unheated parking garage. The Matt the Miller's project is a Group A-2 occupancy, and the construction type of this project and the shell and core is I-B. The entire facility is fully protected by an automatic sprinkler system, and is surrounded by at least 30 feet of yard depth. The Matt the Miller's Tavern tenant is an Assembly Occupancy providing a restaurant and drinking facility for the residences of Carmel. APPLICABLE CODES & STANDARDS Indiana General Administrative Rules (675 IAC 12) 2006 Indiana Building Code (IBC 2006) 2008 Accessibility-Indiana Building Code (ANSI A117.1-2003) 2008 Minimum Design Loads for Buildings (ASCE 7-2005) 2008 Indiana Plumbing Code (UPC 1997) 1999 Indiana Mechanical Code (IMC 2006) 2008 Indiana Electrical Code (NFPA 70-2008) 2009 Indiana Fuel Gas Code (IFGC 2006) 2008 Indiana Fire Code (IFC 2006) 2008 Indiana Energy Conservation Code (ASHRAE 90.1 2007) 2010 NFPA 10-2002 Portable Fire Extinguishers 2006 NFPA 13-1999 Installation of Fire Sprinkler Systems 2002 NFPA 72-2002 National Fire Alarm Code 2006 NFPA 90A-Installation of Air Conditioning & Ventilating Systems 1999 NFPA 90B — Installation of Warm Air Heating & Air Conditioning Systems 1999 Americans with Disabilities Act (ADA-ABA Accessibility Guidelines 2004) 2004 Americans with Disabilities Act (ADAAG 1991-2002) 1991 OCCUPANCY CLASSIFICATIONS: Matt the Miller's Tenant: Group A-2 Building Shell & Core: Group A-2, A-3, B, M, R-2 Parking Garage: Group S-2 OCCUPANT LOAD Matt the Miller's Total Gross Area 5,517 sq ft Total: 278 persons A-2 Occupancy Dining Area 4,056 sf @15 sf/person 270 persons A-2 Occupancy Kitchen Area 1,461 sf @200 sf/person 7 persons A-2 Occupancy Business Area 85 sf @100 sf/person 1 person CONSTRUCTION TYPES: Matt the Miller's Tenant: Type I-B Building Shell & Core: Type I-B Parking Garage: Type I-A BUILDING AREAS: Matt the Miller's Tenant: 5,517 sf Shell & Core: (Ground Floor) 59,470 sf Shell & Core: (Total Building A) 309,587 sf Shell & Core: (Total Phase I) 508,691 sf FIRE RESISTANCE Matt the Miller's Tenant & Shell Shell & Core (Ground Floor): Walls: All construction to be non-combustible Exit Passageways: 2 hours Fire walls: 2 hours Exit Access Corridors: 1 hour Floor: 3 hours (Separating A-2 and S-2) Ceiling: 2 hour (Separating A-2 and R-2) INTERIOR FINISHES Matt the Miller's Tenant & Shell & Core (Ground Floor): Vertical Exits & Passageways: Class B Exit Access Corridors Class C All Others Class C FIRE PROTECTION 100% protection by an automatic sprinkler system per NFPA 13-1999 100% protection by a fire alarm & annuciator system meeting NFPA 72-2002 Sprinkler fire pump and backup power meeting NFPA 20-1999 Stairway pressurization meeting IBC 2008 and NFPA 92A-2002 ACCESSIBILITY REQUIREMENTS All tenant restrooms comply with ICC/ANSI A117.1-2003; Section 604.5.1 PREVIOUS IDHS APPROVALS Project No. 317769 CDR Letter Foundation Release 04.25.06 Project No. 317796 CDR Letter Standard Release -Architectural & Structural 06.19.07 Variance 05-06-68 Issued 06.15.05 Variance 05-10-16 Issued 10.05.05 Variance 06-10-31 Issued 10.05.06 Variance 07-12-34 Issued 12.05.07 28 27.5 27 26.5 26 25 N.5 P P.5 Q Q.5 R R.5 SCALE: 3/16" = 1'-0" 1 Life Safety Plan LS.2 LEGENDEGRESS PATH, POINT OF BEGINNING EGRESS PATH, POINT OF EXITING EGRESS PATH, DISTANCE TRAVEL X'-X"