Loading...
HomeMy WebLinkAboutA7 Site Plan - Details1020 14567238911121314151617181921222324 C L F8Note: Carmel Specialty Existing inlet to remain Carefully remove and reinstall any existing A7 Existing Lawn. wall panels in order to perform new work. Surgery Center No Modifications Slope to drain North 11' - 0"11' - 0"+/- 34' - 0" H20 A7 Match existing RNew landscaping bed,R H15 20' - 0" Re: Landscape plans Tenant Improvement New condensingExisting landscape RDunits, Re: Mechanicalarea to remain Linear metal soffit per Meridian Crossing First Floor details (05500) 11590 N Meridian Street 17' - 0" Area of underground utilitiesCarmel, IN 46032 Remove existing canopy (01732) QQ A8 8' - 6" 4' - 0"4' - 0" Existing electrical Align equipment to remain A7L8 New sidewalk, Re: Civil Remove existing 923 NE Woods Chapel Road, Suite 550 landscaping in conflict Lee's Summit, MO with new work along Recessed light fixture, Re:v 866.700.3757 / f 866.760.3757 building facade PP Electrical. Paint trim ring to match Existing sidewalk to soffit panels, typ. Align layout with Remove existing lighting, concrete remain ISSUED FOR: soffit panel spacing Locations of support bases, and any landscaping in structure, typ. conflict with new work, give Zoning Review4/20/2012 salvaged items to owner (01732) TI Permit5/7/2012 Partial Site Plan - Canopy M8 Site Improvements5/23/2012 Column, typ. 1" = 20'-0"NORTH A6 NN 05'10'20' Provide covers matching existing metal panels at hanger rod openings Canopy Reflected Ceiling PlanPartial Site Plan - Generator Enclosure M1M15 Existing building beyond, protect existing finishes 1/8" = 1'-0" 1" = 20'-0" A6 NORTH MM 05'10'20' Remove existing suspended canopy (01732) 20' - 0" Single-ply roofing membrane,Fascia reveals, 5 equally spaced 12' - 0" turn down face of plywoodeach side A20 Aluminum coping to match color Prefinished aluminum 1/2" cover board over tapered insulation 1' - 6"9' - 0"1' - 6" of existing window system A7 coping, color to match existing window system Continuous treated wood cant (06105) LAluminum canopy to matchL D15 2x continuous treated wood blocking existing (05500) top and bottom, typ. (06105)A7 Aluminum column cover Brick veneer to match (05500) existing color blend and Exposed concrete base with Extended edge gravel stop/fascia panel, with texture brick rubbed finish, typ. (03700) continuous cleats top and bottom (SMACNA Fig. Flush metal panel on 2-2c, sim.) 6' - 2"Existing DriveExisting Island KK 2"x2"x1/4" tube steel Gastinger frame, miter corners, weld all connections. Powder Walker Steel framing,3/4" treated plywood (06105) Saw cut existing paving at new coat finish, color to match Re: Structural column locations Harden Heavy dutyWelded pad lock existing window system Continuous J-0.052 prefinished aluminum, typ.; align Canopy North Elevation Remove existing sculpture and accenthinge, typ.eyes, 1 each gate (05500)Architects L8 channel to matchface with existing at buliding facade lighting, give to owner (01732)(05500) Cane bolt (mounted at soffit panel 817 Wyandotte 1/8" = 1'-0" A7 3-5/8" metal stud framing,16" o.c. JJ Kansas City, MO 64105 interior) (05500) Continuous 3"x3"x1/4" steel angleBrick veneer to match color blend 816 421 8200 p 816 421 1262 f and texture of existing brick Existing metal panels to remain, carefullySteel framing, designwithinsight.com remove and reinstall sections in order toRe: Structural 1" install new canopy flashing A1 G1 Align Enclosure East ElevationEnclosure Gate Elevation Roof drain, connect to existing H15H20 Electrical / Plumbing A7 Tapered insulation over metal A7 Secondary support framing suspended from rain leaders concealed at Sim. deck, slope to drain (07210)PKMR Engineers building facade structure 1/4" = 1'-0" 1/4" = 1'-0" A7A7 HH 8801 Ballentine, Suite 200 SlopeSlope 7/8", 18 gauge, galv. metal 'Z' sections 24" Overland Park, KS 66214 1' - 6" o.c. (multiple span)Enclosure wall per details 913.492.2400 / 2437 fax (04810, 04860) 1" deep x 12" wide flush linear soffit panel, run Linear soffit panel,Aluminum column cover with parallel with building face run parallel withsupport framing (05500)10"x3"x1/4" thick bent plate Mechanical Prefinished aluminum coping to Canopy Fascia building face G1 jamb full height of gate (hold Wiegmann Associates, Inc. Structural column match existing window system, Continuous cleat beyond, typical 3" above paving and extend 750 Fountain Lakes Blvd. turn down 4" min. each face 1" = 1'-0" A7 GG under coping above), paint to Double reveal, typ.St. Charles, MO 63301 Continuous 2x treated match gate (05500) 314.409.3350 1" reveal at base, typ.3" wood blocking Face of building behind existing metal panels Grout full cells at jambs Cast-in-place concrete with Structural brick rubbed finish, typ. 3/4" diameter expansion anchors,Bob D. Campbell & Co. Remove and reinstall existing wall panel as (03300) 24" o.c., anchors to begin 6" from required to install new roof flashingBrick veneer with 4338 Belleview top and bottom edges of plate reinforcing at 24" o.c.Kansas City, MO 64111 Elevation of existing drive Continuous sealant joint FF vertically (04860)816.531.4144 1' - 8" Canopy Section F8 Sheet metal flashing by expansion cover mfr. Civil 1/8" = 1'-0" A7 Flexible expansion cover Cripe Architects + Engineers Flexible vapor retarder with compressible insulation 3939 Priority Way South Drive, Suite 400 CMU wall, Re: Structural (04810)Indianapolis, IN 46240 Tube steel frame (05500)Heavy duty roller bearing 317.844.6777 Treated wood cant (06105)Existing metal wall panels to remain, removeCanopy metal color to match weld-on gate hinge EE and reinstall as needed for new workexisting wall panels, typ. 2x treated wood blocking (06105) Vertical metal panels, with powder 3.5"x1.5" (2 per gate) Landscape coated finish, welded to framePaint CMU to match gate 1/2" cover board Vive Exterior Design (05500) Roof membrane, extend over blocking 15325 Herriman Blvd. Noblesville, IN 46060 Reinforced concrete slab Detail at Enclosure Jamb Tapered insulation on D15 317.773.9933 within enclosure, Re: F8 2" metal deck Structural A7 1 1/2" = 1'-0" ConnectA7 DD Steel framing, Re: Structural canopy fascia1/2" continuous foam 5" KEY PLAN to sameisolation joint with sealant location as Fascia profile per detail existing each Per plan side Reveal detail, SMACNA Secondary support framing suspendedIsolation slab Fig. 1-29B sim. from structure Grout cells below grade CC Treated 3/4" plywood Drawn ByJKy 7/8", 18 gauge, galv. metal hat Reinforced concrete base, between metal studs at Checked ByJBT channels 24" o.c. (multiple span) Re: Structural reveals per elevation 3/4"x3/4" recess joint at upper 1" deep x 12" wide flush linear soffit Enlarged Site Plans, Details fascia, return aluminum back panel, run parallel with building face at sides, top, and bottom Continuous J-channel to match soffit panel BColumn cover color to matchB 3/4" exposed A7 existing wall panels, typ. backup plate lap Continuous recessed sealant joint along Isometric Connect new roof drain to existingExposed concrete base withjoint at lower fascia building face (07920) No Scale rain leaders each side of entrybrick rubbed finish, typ. Section Canopy Expansion Joint at BuildingCanopy West ElevationCanopy Fascia RevealSection at Enclosure Wall A1A8A15A20 1" = 1'-0" 1/8" = 1'-0" 1" = 1'-0" 1/2" = 1'-0" A7A7A7 AA 132456789101112131415161718192021222324 c Project Number:2012.105Copyright 2012