HomeMy WebLinkAboutA7 Site Plan - Details1020
14567238911121314151617181921222324
C
L
F8Note:
Carmel Specialty
Existing inlet to remain
Carefully remove and reinstall any existing
A7
Existing Lawn.
wall panels in order to perform new work.
Surgery Center
No Modifications
Slope to drain North
11' - 0"11' - 0"+/- 34' - 0"
H20
A7
Match existing
RNew landscaping bed,R
H15
20' - 0"
Re: Landscape plans
Tenant Improvement
New condensingExisting landscape
RDunits, Re: Mechanicalarea to remain
Linear metal soffit per
Meridian Crossing First Floor
details (05500)
11590 N Meridian Street
17' - 0"
Area of underground utilitiesCarmel, IN 46032
Remove existing canopy (01732)
QQ
A8
8' - 6"
4' - 0"4' - 0"
Existing electrical
Align
equipment to remain
A7L8
New sidewalk,
Re: Civil
Remove existing
923 NE Woods Chapel Road, Suite 550
landscaping in conflict
Lee's Summit, MO
with new work along
Recessed light fixture, Re:v 866.700.3757 / f 866.760.3757
building facade
PP
Electrical. Paint trim ring to match
Existing sidewalk to
soffit panels, typ. Align layout with
Remove existing lighting, concrete
remain
ISSUED FOR:
soffit panel spacing
Locations of support
bases, and any landscaping in
structure, typ.
conflict with new work, give
Zoning Review4/20/2012
salvaged items to owner (01732)
TI Permit5/7/2012
Partial Site Plan - Canopy
M8
Site Improvements5/23/2012
Column, typ. 1" = 20'-0"NORTH
A6
NN
05'10'20'
Provide covers matching existing metal panels
at hanger rod openings
Canopy Reflected Ceiling PlanPartial Site Plan - Generator Enclosure
M1M15
Existing building beyond, protect existing finishes
1/8" = 1'-0" 1" = 20'-0"
A6 NORTH
MM
05'10'20'
Remove existing suspended canopy (01732)
20' - 0"
Single-ply roofing membrane,Fascia reveals, 5 equally spaced
12' - 0"
turn down face of plywoodeach side
A20
Aluminum coping to match color
Prefinished aluminum
1/2" cover board over tapered insulation
1' - 6"9' - 0"1' - 6"
of existing window system
A7
coping, color to match
existing window system
Continuous treated wood cant (06105)
LAluminum canopy to matchL
D15
2x continuous treated wood blocking
existing (05500)
top and bottom, typ. (06105)A7
Aluminum column cover
Brick veneer to match
(05500)
existing color blend and
Exposed concrete base with
Extended edge gravel stop/fascia panel, with
texture
brick rubbed finish, typ. (03700)
continuous cleats top and bottom (SMACNA Fig.
Flush metal panel on
2-2c, sim.)
6' - 2"Existing DriveExisting Island
KK
2"x2"x1/4" tube steel
Gastinger
frame, miter corners, weld
all connections. Powder Walker
Steel framing,3/4" treated plywood (06105)
Saw cut existing paving at new
coat finish, color to match
Re: Structural
column locations Harden
Heavy dutyWelded pad lock
existing window system
Continuous J-0.052 prefinished aluminum, typ.; align
Canopy North Elevation Remove existing sculpture and accenthinge, typ.eyes, 1 each gate
(05500)Architects
L8
channel to matchface with existing at buliding facade
lighting, give to owner (01732)(05500)
Cane bolt (mounted at
soffit panel
817 Wyandotte
1/8" = 1'-0"
A7
3-5/8" metal stud framing,16" o.c.
JJ
Kansas City, MO 64105
interior) (05500)
Continuous 3"x3"x1/4" steel angleBrick veneer to match color blend 816 421 8200 p
816 421 1262 f
and texture of existing brick
Existing metal panels to remain, carefullySteel framing,
designwithinsight.com
remove and reinstall sections in order toRe: Structural
1"
install new canopy flashing
A1
G1
Align
Enclosure East ElevationEnclosure Gate Elevation
Roof drain, connect to existing
H15H20
Electrical / Plumbing
A7
Tapered insulation over metal A7
Secondary support framing suspended from rain leaders concealed at
Sim.
deck, slope to drain (07210)PKMR Engineers
building facade
structure 1/4" = 1'-0" 1/4" = 1'-0"
A7A7
HH
8801 Ballentine, Suite 200
SlopeSlope
7/8", 18 gauge, galv. metal 'Z' sections 24"
Overland Park, KS 66214
1' - 6"
o.c. (multiple span)Enclosure wall per details
913.492.2400 / 2437 fax
(04810, 04860)
1" deep x 12" wide flush linear soffit panel, run
Linear soffit panel,Aluminum column cover with
parallel with building face
run parallel withsupport framing (05500)10"x3"x1/4" thick bent plate
Mechanical
Prefinished aluminum coping to
Canopy Fascia
building face
G1
jamb full height of gate (hold
Wiegmann Associates, Inc.
Structural column match existing window system,
Continuous cleat
beyond, typical 3" above paving and extend
750 Fountain Lakes Blvd.
turn down 4" min. each face
1" = 1'-0"
A7
GG
under coping above), paint to
Double reveal, typ.St. Charles, MO 63301
Continuous 2x treated
match gate (05500)
314.409.3350
1" reveal at base, typ.3"
wood blocking
Face of building behind existing metal panels
Grout full cells at jambs
Cast-in-place concrete with
Structural
brick rubbed finish, typ.
3/4" diameter expansion anchors,Bob D. Campbell & Co.
Remove and reinstall existing wall panel as
(03300)
24" o.c., anchors to begin 6" from
required to install new roof flashingBrick veneer with 4338 Belleview
top and bottom edges of plate
reinforcing at 24" o.c.Kansas City, MO 64111
Elevation of existing drive
Continuous sealant joint
FF
vertically (04860)816.531.4144
1' - 8"
Canopy Section
F8
Sheet metal flashing by expansion cover mfr.
Civil
1/8" = 1'-0"
A7
Flexible expansion cover
Cripe Architects + Engineers
Flexible vapor retarder with compressible insulation 3939 Priority Way South Drive, Suite 400
CMU wall, Re: Structural (04810)Indianapolis, IN 46240
Tube steel frame (05500)Heavy duty roller bearing
317.844.6777
Treated wood cant (06105)Existing metal wall panels to remain, removeCanopy metal color to match
weld-on gate hinge
EE
and reinstall as needed for new workexisting wall panels, typ.
2x treated wood blocking (06105)
Vertical metal panels, with powder
3.5"x1.5" (2 per gate)
Landscape
coated finish, welded to framePaint CMU to match gate
1/2" cover board
Vive Exterior Design
(05500)
Roof membrane, extend over blocking
15325 Herriman Blvd.
Noblesville, IN 46060
Reinforced concrete slab
Detail at Enclosure Jamb
Tapered insulation on
D15
317.773.9933
within enclosure, Re:
F8
2"
metal deck
Structural
A7
1 1/2" = 1'-0"
ConnectA7
DD
Steel framing, Re: Structural
canopy fascia1/2" continuous foam
5"
KEY PLAN
to sameisolation joint with sealant
location as
Fascia profile per detail
existing each
Per plan
side
Reveal detail, SMACNA
Secondary support framing suspendedIsolation slab
Fig. 1-29B sim.
from structure
Grout cells below grade
CC
Treated 3/4" plywood
Drawn ByJKy
7/8", 18 gauge, galv. metal hat
Reinforced concrete base,
between metal studs at
Checked ByJBT
channels 24" o.c. (multiple span)
Re: Structural
reveals per elevation
3/4"x3/4" recess joint at upper
1" deep x 12" wide flush linear soffit
Enlarged Site Plans, Details
fascia, return aluminum back
panel, run parallel with building face
at sides, top, and bottom
Continuous J-channel to match soffit panel
BColumn cover color to matchB
3/4" exposed
A7
existing wall panels, typ.
backup plate lap
Continuous recessed sealant joint along
Isometric
Connect new roof drain to existingExposed concrete base withjoint at lower fascia
building face (07920)
No Scale
rain leaders each side of entrybrick rubbed finish, typ.
Section
Canopy Expansion Joint at BuildingCanopy West ElevationCanopy Fascia RevealSection at Enclosure Wall
A1A8A15A20
1" = 1'-0" 1/8" = 1'-0" 1" = 1'-0" 1/2" = 1'-0"
A7A7A7
AA
132456789101112131415161718192021222324
c
Project Number:2012.105Copyright 2012