HomeMy WebLinkAbout0130-SU2.2.pdf10'-0" MIN. 10'-0" MIN.
(TYP.)
O.D. + 1'-0" MIN.
2'-0"
WATER
SANITARY
CONC. COLLAR
10' MIN.
LESS THAN 18" OR IN
CASES WHERE
WATER IS BELOW
SAN. SEWER
NOTES
1. THE CLEAR DISTANCES SHALL BE AS MEASURED FROM
THE OUTSIDE EDGE OF THE SANITARY SEWER FACILITY
(SEWER, FORCE MAIN, MANHOLE, OR LIFT STATION) TO
THE OUTSIDE EDGE OF THE WATER SUPPLY (WATER MAIN
OR WELL SCREEN).
2. THE VERTICAL SEPARATION SHALL ONLY BE APPLICABLE
WHEN SANITARY SEWERS AND WATER MAINS CROSS.
WHEN CROSSING, THE SEWER AND WATER MAIN SHALL
CROSS AT A MINIMUM ANGLE OF FORTY-FIVE (45)
DEGREES AS MEASURED FROM THE CENTERLINES OF THE
PIPES AND MAINTAIN THE MINIMUM VERTICAL
SEPARATION A MINIMUM DISTANCE OF TEN (10) FEET ON
EITHER SIDE OF THE SANITARY SEWER. THE JOINTS OF
THE SANITARY SEWER SHALL BE EQUIDISTANT AND AS
FAR AS POSSIBLE FROM THE WATER MAIN JOINTS.
3. SEPARATION DISTANCES LESS THAN THOSE SHOWN WILL
BE CONSIDERED AND MAY BE ALLOWED IF ALL THE
FOLLOWING CONDITIONS ARE MET:
3.1. THE PIPE MATERIAL IS PRESSURE RATED PVC, DIP,
OR PCCP FORCE MAIN MATERIAL PER SECTION 304.
3.1. THE SANITARY SEWER AND WATER MAIN ARE NOT IN
CONTACT.
3.2. THE SANITARY SEWER JOINTS ARE COMPRESSION
TYPE AND PLACED EQUIDISTANT FROM THE WATER
MAIN.
3.3. THE SANITARY SEWER AND WATER MAIN ARE LAID
ON SEPARATE TRENCH SHELVES.
SEE NOTES FOR ALLOWABLE
PIPE MATERIALS
FLEXIBLE COUPLING
OR ADAPTOR
SANITARY LINE AND WATER
LINE SEPARATION
8'-0" MIN.
WATER LINE
SANITARY OR
STORM WATER
MANHOLE
WATER LINE AND MANHOLE
SEPARATION
10'-0" MIN.
WATER LINE
SANITARY LIFT
STATION OR
GRINDER PUMP
STATION
WATER LINE AND SANITARY
LIFT STATION SEPARATION
SANITARY SEWER SERVICE LATERAL
SANITARY SEWER SADDLE TEE CONNECTION
24" MIN. 24" MIN.
24" MIN. 24" MIN.
THAN 18 INCHES OF SEPARATION
NOTE: CONCRETE SADDLE IS
LINE INTERSECTION HAS LESS
SANITARY SEWER AND UTILITY
TO BE USED WHENEVER A
CONCRETE ENCASEMENT
24" MIN.
24" MIN. 24" MIN.
24" MIN.
24" MIN. 24" MIN.
FIRE HYDRANT ASSEMBLY
JOINT RESTRAINT TABLE
CONCRETE CRADLE
WATER LINE CROSSING NOTES
CLEANOUT TYPE 2
SIDE VIEW
TOP VIEW
NOTE: COVER FITTING AND
STAINLESS STEEL STRAPS
WITH PLASTIC WRAP AND
ENCASE WITH ONE FOOT
OF MIXED CONCRETE IN
ALL DIRECTIONS