HomeMy WebLinkAbout04080146 Miscellaneous
PAGE-001
RESIDENTIAL
3ARMEL
TISION:
CONTRACTOR:
SPECIAL :RESIDENTIAL ADDITION TO BASEMENT AND FIRST FLOOR,
PERMIT :ALSO A PORCH. ELECTRICAL AND PLUMBING INVOLVED.
CONDITIONS:688 SQ.FT. TO BSMT; 789 TO 1ST FLR; AND 280 SQ.FT
AND NOTES :PORCH. SEE NOTEPAD--IMPORTANT INFO...
17130300£0028005
BLOCK:
ELI LILLY II
BARNARD BARNARD, E.
10319 DITCH ROAE
(317) 979-4578
PPRICPLU
INSPECTION TYPE: 01
~NSPECTION AREA:
SCHED DATE: 09/I0/{4
CONTACT INFO:
INSPECTOR: WGH
INSTRUCTIONS:
~TS:
PRICE PLUMBING
LOWER FOOTING
INSPECT TIME:
HOHLT, WILLIAM G.
RESULTS:
~OTES:
PASS FAIL
CANCEL RE-FEE FAIL CODE:
PRIOR INSPECTION RESULTS:
LOWER FOOTING
UPPER FOOTING
ROUGH-IN
INSPECTION NOTES:
09/10/04 P
09/10/04 P
03/01/05 F OK TO INSULATE
1 Post permit in front window
2 hange} for beam not approved
3 remove untreated furring
4 fireblock at top and drop ceilings
of stud walls
5 add header
6 sister 2x6 across room to meet irc
802.4
7 vapor barrier between white wood and
basement walls.
8 amend plans at office
*** canno~ locate file*~
WGH
WGH
JAO
INSPECTION WORK LOG - ONE PER PAGE DETAIL FORMA~
PRINTED ON 03/04/05
~ INSPECTION SHEET - CONTINUE£
PERMIT NUMBER: 0408~146 10819 DITCH RD
INSPECTION TYPE: 01
PAGE-002
CARMEL
PRIOR INSPECTION RESULTS {cont'd):
13 ROUGH-IN RE-INSPECTI 03/07/05 JAO