Loading...
HomeMy WebLinkAboutCarmel Specialty Surgery Center (TI).pdfBT WH WS BT Drawing Index Architectural A0 Cover Sheet A1 Demolition, Dimension, and Equipment Plans A2 Finish, Reflected Ceiling & Enlarged Plans A3 Interior Elevations A4 Interior Elevations & Details A5 Schedules & Details Plumbing/Electrical PE1 Plumbing / Electrical - Site Plan PE2 Plumbing / Electrical - Demolition PE3 Plumbing / Electrical - Through Penetration Details P1 Plumbing - Floor Plan P2 Plumbing - Schedules P3 Plumbing - Details P4 Plumbing - Riser Diagrams E1 Electrical - Lighting - Floor Plan E2 Electrical - Power - Floor Plan E3 Electrical - Special Systems - Floor Plan E4 Electrical - Riser Diagram E5 Electrical - Panelboard Schedules E6 Electrical - Schedules / Details Mechanical (for reference only) M0-1 Cover Sheet M0-2 Symbols / Abbreviations / General Notes M1-1 HVAC Airflow Diagram M1-2D Mechanical Floor Plan - Demo M1-2 Mechanical Floor Plan M2-1 Mechanical Floor Plan - Piping M2-2 Medical Gas Piping Plan M3-1 Schedules M3-2 Schedules M4-1 Details Note: Mechanical drawings are included for reference only because design/build scope of work. General Project Information: Project Name: Carmel Specialty Surgical Center Project Address: 11590 N. Meridian Street Carmel, Indiana 46032-6954 Owner: Carmel Specialty Surgical Center Proposed Use: Tenant Improvement / Ambulatory Surgical Center (ASC) Code Enforcement Jurisdiction: City of Carmel Applicable Building Codes: Building Code - 2006 International Building Code with Indiana Amendments Electrical Code - 2008 National Electrical Code with Indiana Amendments Plumbing Code - 1997 Uniform Plumbing Code with Indiana Amendments Mechanical Code - 2006 International Mechanical Code with 2008 Indiana Amendments Energy Code - Indiana Energy Conservation Code 2010 (ASHRAE/IESNA 90.1 2007 Edition) BT WH WS BT BT WH WS BT Building Mechanical (no work) Occupied tenant space, no work this area. Building Mechanical (no work) Occupied tenant space, no work this area. Remove existing construction Remove existing doors and windows Remove existing doors, windows, and frames, give to landlord Remove existing millwork Remove millwork and sink Remove existing Remove construction existing doors and windows Remove existing doors Remove existing storefront and prep for new doors Remove existing windows and doors Remove existing wall from elevator shaft to column 5' - 0" 126 1 Min. 8' - 0" 4' - 0" 108 1 127 1 128 1 BT WH WS BT Med Gas 119 Electrical 120 Sterile Supplies 121 PACU 113 Nurse's Station 114 Staff Toilet 117 Clean Linen 116 Soiled Linen 115 Private Recovery 118 Clean Workroom 122 Soiled Workroom 123 Equipment Storage 124 406 SF Operating Room 1 127 405 SF Operating Room 2 128 Staff Corridor 129 Staff Shower 133 Staff Dress 132 Staff Shower 131 Staff Dress 130 Waiting 101 Reception/ Gypsum board soffit, paint (09260) Plastic laminate upper cabinet with adjustable shelves (06402) 1" filler panel at upper and base cabinets, typ. (06402) Plastic laminate countertop and 4" side and backsplash (06402) Plastic laminate base cabinet with adjustable shelves (06402) Soap dispenser (10801) Sink/faucet, Re: Plumbing Paper towel dispenser (10801) Finished End Finished End Integral sheet vinyl cove base, Re: Room Finish Schedule (09652) Vertical single-hung window (operable side at Soiled Workroom), sill mounted approx 4" below countertop. Countertop to be installed continuius and flush through window opening (08561) 4014 4024 3624 3614 3624 Finished End Finished End 3' - 0" 1' - 11" 3' - 0" 1" 8' - 0" 4' - 7" 6" 6" Modify drawer depth at recessed window 1" A21 A4 Gypsum board soffit, paint (09260) Plastic laminate upper cabinet with adjustable shelves (06402) 1" filler panel at upper and base cabinets, typ. (06402) Plastic laminate countertop and 4" side and backsplash (06402) Plastic laminate base cabinet with adjustable shelves (06402) Soap dispenser (10801) Sink with eye wash, Re: Plumbing Paper towel Melamine interiors Plastic all exposed surfaces (06402) 4" wire pull, typical Provide continuous fire treated wood blocking at top and bottom rail of all wall cabinets (06105) Plastic laminate drawer front and drawer box Melamine interior Base over 2x4 continuous blocking, Re: finish schedule Melamine 3/4" particle board adjustable shelf and bottom 3/4" plywood doors, plastic laminate on all exposed surfaces Sink beyond, re: plans and plumbing Adjustable melamine shelves (2) Provide locks where indicated on elevations Plastic laminate countertop with 4" backsplash and side splashes (06402) Partition construction Refer to casework elevations Varies Refer to casework elevations 2' - 0" 1" 1' - 2" Continuous joint sealant (07920) Soffit per Reflected Ceiling Plan Melamine interiors Standards beyond (06402) Plastic laminate door (06402) 4" wire pull Melamine interior Base over 2x4 continuous blocking, Re: finish schedule Melamine 3/4" particle board adjustable shelf Fixed melamine shelf (3) Melamine 3/4" particle board adjustable shelves 2' - 1" Provide continuous fire treated wood blocking (06105) A4 Frame Type 'B' Welded Hollow Metal Frame Painted (08110) Per Schedule 2" Per Schedule Per Schedule Double Door Width 8" 8" 2' - 8" 8" Per Schedule Per Schedule 2" Per Schedule Door Type '4' Solid Wood Door With Lite with stained finish (08211, 08800) 8" 8" 2' - 8" 8" Per Schedule 8" 8" 2' - 8" 8" Door Type '3' Solid Wood Door With Lite with stained finish (08211, 08800) Frame Type 'A' Knock Down Hollow Metal Frame, Painted (08110) Door Type '1' Solid Wood Door with stained finish (08211, 09910) Per Schedule Door Type '2' Hollow Metal Door, Painted (08110) 2" 2" 2" 2" 3' - 2" 3' - 2" 3' - 2" Per Schedule Per Schedule Door Type '5' Aluminum Entrance Door With Full Lite to match building standard (08410) Per Schedule 2" V.I.F. Per Schedule V.I.F. 2" 2" V.I.F. Frame Type 'C' Aluminum Storefront to Project Title: Carmel Specialty Surgery Center Report date: 05/04/12 Data filename: Z:\12\12.089\Design\Elec\12089 typical surgcenter comcheck report.cck Page 1 of 4 COMcheck Software Version 3.9.0 Interior Lighting Compliance Certificate 2009 IECC Section 1: Project Information Project Type: New Construction Project Title : Carmel Specialty Surgery Center Construction Site: Owner/Agent: Designer/Contractor: 11590 N Meridian Street Carmel, IN 46032 Carmel Specialty Surgery Center CA Darren Thrasher PKMR Engineers 8801 Ballentine Suite 200 Overland Park, KS 66214 913-492-2400 Section 2: Interior Lighting and Power Calculation A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B x C) Hospital 5765 1.2 6918 Total Allowed Watts = 6918 Section 3: Interior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) Hospital (5765 sq.ft.) Linear Fluorescent 1: Type A: Williams Series 50G / 48" T8 32W / Electronic 4 10 128 1280 Linear Fluorescent 2: Type B: Williams Series 50G / 48" T8 32W / Electronic 3 24 96 2304 Linear Fluorescent 2a: Type B1: Williams Series 50G / 24" T8 17W / Electronic 3 3 51 153 Linear Fluorescent 3: Type C: Williams Series 50G / 48" T8 32W / Electronic 2 13 64 832 Linear Fluorescent 3a: Type C1: Williams Series 50G / 24" T8 17W / Electronic 2 1 34 34 Linear Fluorescent 4: Type D: Williams DI Series / 48" T8 32W / Electronic 3 1 96 96 Linear Fluorescent 4a: Type D1: Williams DI Series / 24" T8 17W / Electronic 3 6 51 306 Linear Fluorescent 5: Type F: Williams Series 77 / 48" T8 32W / Electronic 2 4 64 256 Linear Fluorescent 6: Type F1: Williams Series 77 / 24" T8 17W / Electronic 2 1 34 34 Compact Fluorescent 1: Type H: Williams PV60 Series / Triple 4-pin 32W / Electronic 1 12 32 384 Compact Fluorescent 2: Type K: Williams PVSL60 Series / Triple 4-pin 32W / Electronic 1 1 32 32 Project Title: Carmel Specialty Surgery Center Report date: 05/04/12 Data filename: Z:\12\12.089\Design\Elec\12089 typical surgcenter comcheck report.cck Page 2 of 4 ❑ 3. Daylight zones have individual lighting controls independent from that of the general area lighting. Exceptions: ❑ Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device. ❑ Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a separate switch for general area lighting. ❑ 4. Independent controls for each space (switch/occupancy sensor). Exceptions: ❑ Areas designated as security or emergency areas that must be continuously illuminated. ❑ Lighting in stairways or corridors that are elements of the means of egress. ❑ 5. Master switch at entry to hotel/motel guest room. ❑ 6. Individual dwelling units separately metered. ❑ 7. Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. ❑ 8. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either controlling all luminaires, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switching the middle lamp luminaires independently of other lamps, or switching each luminaire or each lamp. Exceptions: ❑ Only one luminaire in space. ❑ An occupant-sensing device controls the area. ❑ The area is a corridor, storeroom, restroom, public lobby or sleeping unit. ❑ Areas that use less than 0.6 Watts/sq.ft. ❑ 9. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: ❑ Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security. ❑ 10.Photocell/astronomical time switch on exterior lights. Exceptions: ❑ Lighting intended for 24 hour use. ❑ 11.Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts). Exceptions: ❑ Electronic high-frequency ballasts; Luminaires on emergency circuits or with no available pair. Interior Lighting PASSES: Design 17% better than code. Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2009 IECC requirements in COMcheck Version 3.9.0 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Darren Thrasher - Project Manager 5/7/12 Project Title: Carmel Specialty Surgery Center Report date: 05/04/12 Data filename: Z:\12\12.089\Design\Elec\12089 typical surgcenter comcheck report.cck Page 3 of 4 COMcheck Software Version 3.9.0 Exterior Lighting Compliance Certificate 2009 IECC Section 1: Project Information Project Type: New Construction Project Title : Carmel Specialty Surgery Center Exterior Lighting Zone: 3 (Other) Construction Site: Owner/Agent: Designer/Contractor: 11590 N Meridian Street Carmel, IN 46032 Carmel Specialty Surgery Center CA Darren Thrasher PKMR Engineers 8801 Ballentine Suite 200 Overland Park, KS 66214 913-492-2400 Section 2: Exterior Lighting Area/Surface Power Calculation A Exterior Area/Surface B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B x C) F Proposed Watts 00 No 0 0 Total Tradable Watts* = 0 0 Total Allowed Watts = 0 Total Allowed Supplemental Watts** = 750 * Wattage tradeoffs are only allowed between tradable areas/surfaces. ** A supplemental allowance equal to 750 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Section 3: Exterior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) Project Title: Carmel Specialty Surgery Center Report date: 05/04/12 Data filename: Z:\12\12.089\Design\Elec\12089 typical surgcenter comcheck report.cck Page 4 of 4 Exterior Lighting Efficacy: ❑ 6. All exterior building grounds luminaires that operate at greater than 100W have minimum efficacy of 60 lumen/watt. Exceptions: ❑ Lighting that has been claimed as exempt and is identified as such in Section 3 table above. ❑ Lighting that is specifically designated as required by a health or life safety statue, ordinance, or regulation. ❑ Emergency lighting that is automatically off during normal building operation. ❑ Lighting that is controlled by motion sensor. Exterior Lighting TBD: Invalid exterior use type Main entry (100 ft of door width): Non-tradable Wattage HID 1: TYPE Q: INVUE ENTRI SERIES / Metal Halide 100W / Standard 1 2 100 200 Total Tradable Proposed Watts = 0 Section 4: Requirements Checklist Lighting Wattage: ❑ 1. Within each non-tradable area/surface, total proposed watts must be less than or equal to total allowed watts. Across all tradable areas/surfaces, total proposed watts must be less than or equal to total allowed watts. Compliance: Invalid exterior use type Controls, Switching, and Wiring: ❑ 2. All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt lighting. ❑ 3. Lighting not designated for dusk-to-dawn operation is controlled by either a a photosensor (with time switch), or an astronomical time switch. ❑ 4. Lighting designated for dusk-to-dawn operation is controlled by an astronomical time switch or photosensor. ❑ 5. All time switches are capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. Total Proposed Watts = 5711 Section 4: Requirements Checklist Lighting Wattage: ❑ 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 6918 5711 YES Controls, Switching, and Wiring: ❑ 2. Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to vertical fenestration. Match Existing Building Standard (08410) 8' - 8" V.I.F. Per Schedule Per Schedule Per Schedule Per Schedule Per Schedule Per Schedule Door Type '6' Private Recovery (08343) Note: All door glazing to be tempered (T). T T T T T T T Sliding section Partition per floor plan Double studs at all jamb and head conditions for all openings (09260) Flush frame where occurs Hollow metal frame, Paint: 3 jamb anchors per jamb min. (08110) 2" 1/2" Varies by wall type Sealant continuous around frame (07920) Door per schedule 1/2" Door per schedule Partition per floor plan Double studs at all jamb and head conditions for all openings (09200) Flush frame where occurs Hollow metal frame, Paint: 3 jamb anchors per jamb min. (08110) 2" 1/2" 6" Varies by wall type Door per schedule Partition per floor plan Sealant continuous around frame (07920) Flush frame where occurs Hollow metal frame, Paint: 3 jamb anchors per jamb min. (08110) 2" 1/2" 6" Varies by wall type Double studs at all jamb and head conditions for all 2" openings (09260) Door and Frame Schedule Comments: 1. Painted hollow-metal door. 2. Match building standards. 3. Automatic door operator (08711). 4. Mount hospital latch at 45" A.F.F. (08711). 5. Provide 3/4" undercut; Re: Mech. 6. Sliding ICU/CCU door and frame (08343). General Notes: A. All doors, frames, and hardware to match the building standard unless otherwise noted. All hardware shall comply with ADA standards. B. All means of egress doors shall be of a side-swinging type. C. All means of egress doors shall be readily openable from the side of which egress is to be made without the use of a key, special knowledge or effort. D. Door handles, pulls, latches, locks and other operating devices shall be at maixmum height of 48" above the finished floor. E. Thresholds are not to exceed 1/2" in height with beveled edges no greater than 1:2 slope. typ. F. Doors opening into mechanical or electrical equipment rooms, stairs, loading docks, and entrances to vehicular traffic areas shall have a detectible warning knurled surface on the door handle. General Notes: A. All windows to receive window blinds. (12491) B. Clean and protect all surfaces/finishes to remain during construction. C. All interior door frames to be painted P-4 D. Gypsum board soffits and ceilings to be painted P-1. (09910) E. Provide crash rails and corner guards per plans and specifications. (10260) F. Contractor shall submit all finishes for Architect/Designer's approval prior to installation. G. Contractor shall submit a seaming diagram for all carpet and resilient flooring for Architect/Designer's approval prior to installation. H. Patch all finishes affected by demolition/construction. All scratches, dents, cracks and/or openings on existing and new walls surfaces are to be filled and sanded smooth to provide a "like new" surface condition prior to installing new finishes. I. Provide a smooth finished wall surface down to the subfloor to allow for the proper installation of the specified wall base for all existing wall construction within the area of work. This is inclusive, but not limited to taping, finishing, trim beads, and the filling of screw holes and voids. J. Feather existing irregular flooring conditions to achieve a smooth, unnoticeable transition. K. All floor surfaces shall be stable, firm, and slip resistant per ICC/ANSI A117.1 2003; changes in floor level shall not exceed 1/4" vertical height. L. All carpet pile thickness shall not exceed 1/2" per ICC/ANSI A117.1 2003. M. Specified flooring is to be extended under all existing millwork knee spaces, equipment, and/or other openings where the floor is exposed. N. Ceiling heights may vary slightly due to floor variations, verify existing conditions in the field. O. Provide straight (toeless) base at carpet and cove base at VCT/resilient flooring, typ. P. Cove base to be installed tightly to adjacent partition to eliminate gaps. Room Finish Schedule Comments: 1. Provide 6" integral sheet vinyl cove base. 2. Provide epoxy paint. 3. Provide epoxy paint, color P-1, at operating room ceilings. 4. Provide 48" high fiberglass reinforced panels on all surrounding sides of sink. 5. Provide 3/4" fire retardant plywood over walls to height of 7'-0" on East & West walls. (06105) 6. Use PL-2 on locker faces and sides. 7. Use PL-1 for countertops and PL-2 on cabinets. 8. Use PL-1 for Nurse Station countertops and PL-2 for base cabinets. Use PL-1 for transaction countertop. At nurse station front face, use PL-2 for primary laminate, use PL-1 for accent band. 9. Refer to floor pattern plan for sheet vinyl design. 10. Refer to elevations for wood finish on front and paper composite transaction top and accent band. Cabinets to be PL-2 and countertop worksuface to be PL-1. Finish Scheme 'A' - "Spa Treatment" Floor Finish Legend: CPT Carpet Tile: Patcraft Pattern: Tranquil Modular I0243 Color: Calm 00112 Installation: Monolithic SV-1 Sheet Vinyl: Mannington Pattern: BioSpec MD Color: Sandrift #15203 Rod Color: matching SV-2 Sheet Vinyl: Mannington Pattern: BioSpec MD Color: Blue Ridge#15376 SV-3 Sheet Vinyl: Mannington Pattern: BioSpec MD Color: Bedrock #15369 SV-4 Sheet Vinyl: Mannington Pattern: BioSpec MD Color: Sandrift #15203 SC Sealed Concrete RB Rubber Base: Roppe Color: #194 Burnt Umber Ceiling Finish Legend: ACT1 2x4 Acoustical Ceiling Tile (09511) ACT2 2x2 Acoustical Ceiling Tile (09511) ACT3 2x4 Vinyl Wrapped Acoustical Ceiling Tile (09511) GYP Gypsum Board Painted Ceiling Paint to be P-1 Plastic Laminate Cabinetry, Countertops, etc.: PL-1 Formica, Chocolate Warp #5881-58 (Countertops) PL-2 Formica, Natural Maple #756-58 (Base/Upper Cabinets) MT-1: Mosiac Tile: Avani, Hypnotic Blend Solid Surface (if needed): SS-1 Avonite Color: Bone, F1-8010 Alternate: Corian, Vanilla Paper Composite Countertop: Richlite Color: Browns Point, Northwest Collection 3 cm thick Fabric Wrapped Tackable Surface: Designtex Pattern: Gravity Color: Carbon #4106-804 Doors: to match Haworth Office Espresso Finish Cubicle Curtain: Knoll Textiles Name: Avenue Style Number: C1088/6 Color: Wisteria Corner Guards and Crash Rails: C/S Acrovyn Color: Cappuccino #479 or InPro IPC Color: Monterey 0110 Wall Finish Legend: WC-1 Wall Covering: Maharam Pattern: Inscribe 399486 Color: Moth 003 (Waiting, Reception, Files, Multi- Purpose) WC-2 Wall Covering: Versa Pattern: Reflections Color: ASL-126003 Snow Field (Pre-Op/Recovery) P-1 Paint: Sherwin Williams Color: SW 7006 Extra White (ceilings) P-2 Paint: ICI Color: Manuscript, #40YY 60/103 Order #: A1844 (walls) P-3 Paint: Color: Order #: (accent walls) P-4 Paint: ICI Color: Manor House, #50YR 08/038 Order #: A1701 (door frames) FRP Fiberglas Reinforced Plastic InPro Corporation Color: Monterey #0110 Checked By Drawn By Project Number: c Copyright 2012 KEY PLAN 817 Wyandotte Kansas City, MO 64105 816 421 8200 p 816 421 1262 f designwithinsight.com Gastinger Walker Harden Architects ISSUED FOR: A 13 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 23 45678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 B C D E F G H J K L M N P Q R R Q P N M L K J H G F E D C B A Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 C:\Documents and Settings\jkyger\Desktop\2012.105 SurgCenter Carmel Meridian_JKy.rvt A5 Schedules & Details JKy JBT 2012.105 PKMR Engineers 8801 Ballentine, Suite 200 Overland Park, KS 66214 913.492.2400 / 2437 fax Wiegmann Associates, Inc. 750 Fountain Lakes Blvd. St. Charles, MO 63301 314.409.3350 Bob D. Campbell & Co. 4338 Belleview Kansas City, MO 64111 816.531.4144 Cripe Architects + Engineers 3939 Priority Way South Drive, Suite 400 Indianapolis, IN 46240 317.844.6777 Vive Exterior Design 15325 Herriman Blvd. Noblesville, IN 46060 317.773.9933 Zoning Review 4/20/2012 TI Permit 5/7/2012 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.3757 / f 866.760.3757 Tenant Improvement Carmel Specialty Surgery Center Electrical / Plumbing Mechanical Structural Civil Landscape Room Finish Schedule Room Number Room Name Floor Finish Base Finish Walls Ceiling Finish Ceiling North East South West Height Comments 101 Waiting CPT RB WC-1 WC-1 WC-1 WC-1 ACT-2 RE: RCP 102 Reception/ Copy CPT RB WC-1 WC-1 WC-1 WC-1 ACT-2/GYP RE: RCP 10 103 Lounge CPT RB WC-1 WC-T WC-1 WC-1 ACT-1 RE: RCP 104 Vacuum SC RB P-2 P-2 P-2 P-2 None RE: RCP 105 Exit Corridor SV-1 SV-1 -- WC-2 WC-2 WC-2 ACT-1 RE: RCP 106 Patient Toilet SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-1 RE: RCP 1,2 107 Step-Down Recovery SV-1/SV-2/SV-3 SV-1 WC-2 P-2 WC-2 WC-2 ACT-1 RE: RCP 1,6,7,9 108 Procedure SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-3 RE: RCP 1,2,7 109 Office CPT RB P-3 P-3 P-3 P-3 ACT-1 RE: RCP 110 Office CPT RB P-3 P-3 P-3 P-3 ACT-1 RE: RCP 111 Consultation CPT RB P-3 P-3 P-3 P-3 ACT-1 RE: RCP 112 Hall SV-1 SV-1 -- -- WC-2 WC-2 ACT-1 RE: RCP 1 113 PACU SV-1/SV-2/SV-3 SV-1 -- WC-2 P-2 WC-2/P-2 ACT-1 RE: RCP 1,9 114 Nurse's Station SV-1 SV-1 WC-2 WC-2 -- -- ACT-1/GYP RE: RCP 1,7,8 115 Soiled Linen SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-3 RE: RCP 1,2 116 Clean Linen SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-1 RE: RCP 1 117 Staff Toilet SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-1 RE: RCP 1,2 118 Private Recovery SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-1 RE: RCP 1 119 Med Gas SC RB P-2 P-2 P-2 P-2 None RE: RCP 120 Electrical SC RB P-2 P-2 P-2 P-2 None RE: RCP 5 121 Sterile Supplies SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-3 RE: RCP 1,2 122 Clean Workroom SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-3 RE: RCP 1,2,7 123 Soiled Workroom SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-3 RE: RCP 1,2,7 124 Equipment Storage SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-3 RE: RCP 1,2 125 Janitor SV-1 SV-1 P-2/FRP P-2/FRP P-2/FRP P-2/FRP ACT-3 RE: RCP 1,2,4 126 Sterile Corridor SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-3 RE: RCP 1 127 Operating Room 1 SV-4 SV-4 P-2 P-2 P-2 P-2 GYP RE: RCP 1,2,3,7 128 Operating Room 2 SV-4 SV-4 P-2 P-2 P-2 P-2 GYP RE: RCP 1,2,3,7 129 Staff Corridor SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-1 RE: RCP 1 130 Staff Dress SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-1 RE: RCP 1,6 131 Staff Shower SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-1 RE: RCP 1,2 132 Staff Dress SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-1 RE: RCP 1,6 133 Staff Shower SV-1 SV-1 P-2 P-2 P-2 P-2 ACT-1 RE: RCP 1,2 Door and Frame Schedule Door Number Room Name Door Frame Type Width Height Thickness Type Jamb Head Rating Hardware Comments 101 1 Waiting 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 45 Min Set 1 101 2 Waiting 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 2 5 102 1 Reception/Copy 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 3 103 1 Lounge 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 3 104 1 Vacuum 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 45 Min Set 4 105 1 Exit Corridor 1 4' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 45 Min Set 5 106 1 Patient Toilet 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 6 5 108 1 Procedure 1 4' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 7 109 1 Office 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 8 110 1 Office 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 8 111 1 Consultation 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 8 112 1 Hall 4 7' - 4" 7' - 0" 1 3/4" B A12/A5 A20/A5 Set 9 3,5 113 1 PACU 5 3' - 0" 7' - 9" 2" C A12/A5 A20/A5 Set 10 2 115 1 Soiled Linen 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Smoke Set 11 5 116 1 Clean Linen 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Smoke Set 12 5 117 1 Staff Toilet 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 13 5 118 1 Private Recovery 6 8' - 6" 7' - 0" 2" 6 119 1 Med Gas 5 3' - 0" 7' - 9" 2" C A12/A5 A20/A5 Set 10 120 1 Electrical 5 3' - 0" 7' - 9" 2" C A12/A5 A20/A5 Set 10 121 1 Sterile Supplies 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Smoke Set 2 5 122 1 Clean Workroom 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 3 5 123 1 Soiled Workroom 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 3 5 124 1 Equipment Storage 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Smoke Set 3 5 125 1 Janitor 1 2' - 6" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 16 5 126 1 Sterile Corridor 4 7' - 4" 7' - 0" 1 3/4" B A12/A5 A20/A5 Set 9 3,5 127 1 Operating Room 1 3 4' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 7 128 1 Operating Room 2 3 4' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 7 129 1 Staff Corridor 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 15 129 2 Staff Corridor 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 2 5 130 1 Staff Dress 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 17 5 131 1 Staff Shower 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 13 5 132 1 Staff Dress 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 17 5 133 1 Staff Shower 1 3' - 0" 7' - 0" 1 3/4" A A12/A5 A20/A5 Set 18 5 1/4" = 1'-0" D12 Door and Frame Types 3" = 1'-0" A20 Detail at Door Head A2 3" = 1'-0" A12 Detail at Door Jamb Not to Scale G12 Door and Frame Schedule Not to Scale A1 Room Finish Schedule E13 Melamine interiors Plastic laminate doors with Plexiglas view pane, countersink Plexiglas into cabinet door frame (06402) 4" wire pull, typical Provide continuous fire treated wood blocking at top and bottom rail of all wall cabinets (06105) Plastic laminate drawer front and drawer box Melamine interior Base over 2x4 continuous blocking, Re: Room Finish Schedule Melamine 3/4" particle board adjustable shelf and bottom Metal clips (8 total per view panel) (06404) Provide locks where indicated on elevations Plastic laminate countertop with 4" backsplash and side splashes (06402) (2) Adjustable melamine shelves (06402) Plastic laminate doors with Plexiglas view pane, countersink Plexiglas into cabinet door frame (06402) Refer to casework elevations Varies Refer to casework elevations 2' - 0" 1" 1' - 2" A4 E17 Continuous joint sealant (07920) Plastic laminate cabinets (06402) Fire retardant wood blocking with laminate to match cabinets. (06105) 5/8" gypsum wall board on 3- 5/8" metal studs (09260), paint 3/4" Re: Reflected Ceiling Plan Plastic laminate cabinets/lockers (06402) Fire retardant wood blocking with plastic laminate to match cabinets/lockers. (06105) 5/8" gypsum wall board on 3 5/8" metal studs (09260), paint 4 1/2" 3/4" Provide cored holes for cabling/phone /data, typ. 3/4" birch veneer panel, light stain (06402) 3/4" x 1 1/2" birch trim, light stain (06402) 3/4" birch veneer panel, stain dark to match doors (06402) 3/4" x 1 1/2" birch trim, light stain (06402) 3' - 6" 4" 4" 1' - 10" 4" 8" 1' - 0" 2' - 0" 6" 1' - 8" 3' - 0" Fabric wrapped tackable surface (06402) 3cm granite transaction counter (06402) 2' - 6" 1 1/2" Plastic laminate countertop, provide (2) grommets (06402) Rubber base (09653) Removeable plastic laminate access panel (06402) 1" 4" 3" Provide cored holes for cabling/phone /data, typ. 3/4" birch veneer panel, light stain (06402) 3/4" x 1 1/2" birch trim, light stain (06402) 3/4" birch veneer panel, stain dark to match doors (06402) 3/4" x 1 1/2" birch trim, light stain (06402) 4" 4" 1' - 10" 4" 6" 1' - 8" 3cm granite transaction counter (06402) 2' - 6" 1 1/2" 2' - 10" 1' - 0" 2' - 0" 3' - 0" 1 1/2" Plastic laminate countertop, provide (2) grommets (06402) Rubber base (09653) Removeable plastic laminate access panel (06402) 1" 4" 3" Plastic laminate filler (06402) Plastic laminate countertop, provide (2) grommets (06402) 3' - 6" 4" 1' - 8" 6" 1' - 0" 1' - 0" 2' - 0" 1" 1" 3' - 2" Fabric wrapped tackable surface (06402) 2' - 6" 1 1/2" 1" 4" 3" Plastic laminate transaction counter (06402) Plastic laminate accent band on 1/2" MDF (06402) Plastic laminate 3/4" MDF (06402) Plastic laminate box/box/file with 4" wire pulls, see elevations for locations Sheet vinyl cove base (09653) Sheet vinyl cove base (09653) Black metal support angle beyond (06402) Provide cored holes for cabling/phone/ data, typ. 4" wire pulls, typ. (06402) 1' - 6" 1' - 6" Per Plan Per Plan Cubicle Curtain per plan. (2) Wall protection bumpers. (10260) Patient recovery bed. (N.I.C.) Medical gas outlets. Re: Mechanical. OVS Height. Re: Mechanical 2'-6" 2'-6" 6'-0" (Re: Electrical) Re: Electrical Height. 9" 9" Monitor duplex power receptacle. Re: Electrical Duplex power receptacle. Re: Electrical Nurse Call Wall blocking for wall monitor. (06105) of Bay Sharps Container (N.I.C.) Light Switch Height. Re: Electrical 4'-8" Base per schedule. Horizontal Wall protection bumpers. (10260) Plastic laminate tansaction counter (06402) Plastic laminate countertop (06402) Open Gypsum board soffit @ 8'-0" A.F.F. (09260), paint Plastic laminated Box/Box/ File with lockable drawers, typ. (06402) Integral sheet vinyl cove base, Re: Room Finish Schedule (09652) Fabric wrapped panel and side returns, typ. (09985) Removeable plastic laminate panel beyond (06402) Plastic laminate (PL-1) accent band (06402) 1818 Pencil drawer at each work area; typ. (06402) 1818 Open 2' - 6" 1' - 0" 3' - 6" A8 A4 Gypsum board soffit @ 8'-0" A.F.F. (09260), paint Plastic laminate countertop (06402) Plastic laminate (PL-1) accent band (06402) Plastic laminate (PL-2) accent band (06402) Integral sheet vinyl cove base, per room finish schedule (09652) 4" 1' - 8" 6" 1' - 0" 3' - 6" A8 A4 3 cm paper composite transaction counter (06402) Plastic laminate countertop(06402) Open Gypsum board soffit @8'-0" A.F.F. (09260), paint Plastic laminated Box/Box/ File with lockable drawers, typ. (06402) Integral sheet vinyl cove base, Re: Room Finish Schedule (09652) Removeable plastic laminate panel beyond (06402) Pencil drawer at each work area; typ. (06402) 2' - 6" 4" 2' - 6" 1' - 0" Open 3' - 6" 2' - 10" Fabric wrapped panel and side returns, typ. (09985) 1" 1818 A13 A4 A17 A4 4" 2' - 6" 8" 3' - 6" 4" 2' - 6" 2' - 10" 3' - 4 1/2" 2" 1' - 9" 1" 1' - 9" 1" 1' - 9" 1" 1' - 9" 1" 1' - 9" 2" 3 cm paper composite transaction counter top, upper and lower (06402) Birch venener panel, dark stain (06402) 3/4" x1 1/2" birch trim (edge band at countertop) light stain (06402) Gypsum board soffit, paint (09260) Straight (toeless) base, Re: Room Finish Schedule (09653) wood grain wood grain wood grain wood grain wood grain 8' - 0" 3 1/2" A17 A4 A13 A4 Gypsum board soffi, paint (09260) Double bay scrub sink with knee controls (OF/CI) Re: Plumbing 12 inch wide stainless steel shelf ASTM A666, Type 304 .05" thick (1.3mm). Provide blocking for fasteners at ends and back. Contractor to verify dimensions for fit. Radius edge @ front, seal back and sides. Equal to John Boos wall shelf, full width of wall opening. (CF/CI) Integral sheet vinyl cove base (09652) Re: Room Finish Schedule 5' - 8" V.I.F. 2' - 10" 2' - 10" 5' - 1" 8' - 0" Checked By Drawn By Project Number: c Copyright 2012 KEY PLAN 817 Wyandotte Kansas City, MO 64105 816 421 8200 p 816 421 1262 f designwithinsight.com Gastinger Walker Harden Architects ISSUED FOR: A 13 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 23 45678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 B C D E F G H J K L M N P Q R R Q P N M L K J H G F E D C B A Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 C:\Documents and Settings\jkyger\Desktop\2012.105 SurgCenter Carmel Meridian_JKy.rvt A4 Interior Elevations & Details JKy JBT 2012.105 PKMR Engineers 8801 Ballentine, Suite 200 Overland Park, KS 66214 913.492.2400 / 2437 fax Wiegmann Associates, Inc. 750 Fountain Lakes Blvd. St. Charles, MO 63301 314.409.3350 Bob D. Campbell & Co. 4338 Belleview Kansas City, MO 64111 816.531.4144 Cripe Architects + Engineers 3939 Priority Way South Drive, Suite 400 Indianapolis, IN 46240 317.844.6777 Vive Exterior Design 15325 Herriman Blvd. Noblesville, IN 46060 317.773.9933 Zoning Review 4/20/2012 TI Permit 5/7/2012 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.3757 / f 866.760.3757 Tenant Improvement Carmel Specialty Surgery Center Electrical / Plumbing Mechanical Structural Civil Landscape A3 1" = 1'-0" A21 Cabinet Section with Sink A3 1" = 1'-0" K21 Cabinet Section OR 1 A3 1" = 1'-0" K16 Cabinet Section OR 2 A4 3" = 1'-0" E17 Detail @ Operating Room Millwork Soffit A4 3" = 1'-0" E13 Detail @ Typical Millwork Soffit A4 1" = 1'-0" A17 Section @ Reception Counter Upper A4 1" = 1'-0" A13 Section @ Reception Counter Lower A4 1" = 1'-0" A8 Section @ Nurse's Counter A1 1/2" = 1'-0" A1 Elevation @ Typical PACU Bay A2 1/2" = 1'-0" K8 Elevation @ Nurse Station A2 1/2" = 1'-0" K1 Elevation @ Nurse Station A2 1/2" = 1'-0" E1 Elevation @ Reception A2 1/2" = 1'-0" E7 Elevation @ Reception A1 1/2" = 1'-0" 1 Elevation @ Scrub Sink dispenser (10801) Finished End Finished End Integral sheet vinyl cove base, Re: Room Finish Schedule (09652) Vertical single-hung window (operable side at Soiled Workroom), sill mounted +/- 4" below countertop. Countertop to be installed continuous and flush through window opening (08561) 4014 3624 4024 3614 3624 6" 1' - 5" Ultrasonic Cleaner (OF/CI). Provide 1" indirect drain with funnel and trap below cabinet, Re: Plumbing. Modify drawer depth at recessed window 8' - 0" 3' - 0" 1' - 11" 3' - 0" A21 A4 Integral base; Re: Finish Schedule Clinical service sink; Re: Plumbing 1' - 6" 1' - 6" (Verify with Tenant) 2' - 6" 3' - 0" 2' - 9 1/2" 2' - 1 1/2" 3' - 0" Plastic laminate upper cabinet with adjustable shelves (06402) 1" filler panel at upper and base cabinets, typ. (06402) Plastic laminate countertop and 4" side and backsplash (06402) Plastic laminate base cabinet with adjustable shelves (06402) Soap dispenser (10801) Sink/faucet, Re: Plumbing Paper towel dispenser (10801) Finished End Integral sheet vinyl cove base, Re: Room Finish Schedule (09652) 3614 3624 Finished End 3614 3624 3414 Refrigerator (OF/CI) 6" 6" 2' - 11" Finished Bottom 1" A21 A4 3614 3614 3414 sim 3' - 0" 1' - 11" 3' - 0" 1" 8' - 0" Gypsum board soffit, paint (09260) Plastic laminate upper cabinet with Plexiglas view pane and adjustable shelves (06402) Plastic laminate countertop and 4" side and backsplash (06402) Plastic laminate base cabinet with Plexiglas view pane and adjustable shelf (06402) Sheet vinyl cove base, Re: Room Finish Schedule (09652) Finished End Filler panel at upper and base cabinets, typ. (06402) Locks (06402) 3314 3324 2' - 10 1/2" 5' - 0 1/2" Gypsum board control joint, typ. Gypsum board control joint, typ. K21 A4 K16 A4 Gypsum board soffit, paint (09260) Plastic laminate upper cabinet with adjustable shelves (06402) 1" filler panel at upper and base cabinets, typ. (06402) Plastic laminate countertop with 4" side and backsplash (06402) Plastic laminate base cabinet with adjustable shelves (06402) Soap dispenser (10801) Sink/faucet, Re: Plumbing Paper towel dispenser (10801) Finished End Integral sheet vinyl cove base, Re: Room Finish Schedule (09652) 3614 3624 Finished End 3614 3624 A21 A4 6" 6" 3' - 0" 1' - 11" 3' - 0" 1" 8' - 0" 6" 6" Undercounter refrigerator (OF/CI) Ice Maker (OF/CI) Plastic laminate upper cabinet with adjustable shelves (06402) 1" filler panel at upper and base cabinets, typ. (06402) Plastic laminate countertop and 4" side and backsplash (06402) Plastic laminate base cabinet with adjustable shelves (06402) Soap dispenser (10801) Sink/faucet, Re: Plumbing Paper towel dispenser (10801) Integral sheet vinyl cove base, Re: Room Finish Schedule (09652) 3624 Finished End Gypsum board soffit @ 8'-0" A.F.F. (09260), paint 4014 Finished End 3' - 0" 1' - 11" 3' - 0" 1" 8' - 0" 1824 2014 1" A21 A4 Lock (01402) 2' - 1" Gypsum board soffit, paint (09260) Plastic laminate lockers, four high (10500) Integral sheet vinyl cove base, Re: Room Finish Schedule (09652) 1" filler panel at each side, typ. (10500) 1' - 0" 1' - 0" 1' - 0" 1' - 0" 6" 1' - 6 1/2" 1' - 6 1/2" 1' - 6 1/2" 1' - 6 1/2" 6' - 9" 6" 3' - 1" 3' - 1" 1" 6' - 9" 1' - 0" 1' - 0" 1' - 0" 1' - 0" 1' - 0" Gypsum board soffit, paint (09260) Plastic laminate lockers, two high (10500) Integral sheet vinyl cove base, Re: Room Finish Schedule (09652) 1" filler panel at each side, typ. (10500) To Reflective Surface 3' - 4" Max. Grab bars (10801) Base, Re: Finish Schedule (09653) Toilet, Re: Plumbing Mirror (10801) centered on lavatory Toilet paper dispenser(10801) Paper towel dispenser (10801) Lavatory with insulated pipes below (10801) Re: Plumbing Soap dispenser (10801) 1' - 6" 2' - 11" 5" 1' - 6" 3' - 0" (min) 1' - 2 1/2" Min. 1' - 0" 17" to 19" Min. 3' - 6" Max. to operable part 4' - 0" 3' - 6" Min. 1' - 2" 2' - 4" Grab bars (10801) Base, Re: Finish Schedule (09653) Toilet paper dispenser (10801) Toilet Re: Plumbing 8" 17" to 19" Min. 4' - 6" Min. 3' - 4" 1' - 6" 2' - 11" Gypsum board soffit @ 8'-0" A.F.F. (09260), paint Ceiling mounted shower curtain and track (10801) Accessible shower with folding seat, Re: plumbing Grab bars (10801) 2' - 10" 11" 2' - 0" 1' - 7" 17" to 19" 6" 6" Undercounter refrigerator (OF/CI) Blanket Warmer (OF/CI) Plastic laminate upper cabinet with adjustable shelves (06402) 1" filler panel at upper and base cabinets, typ. (06402) Plastic laminate countertop and 4" side and backsplash (06402) Plastic laminate base cabinet with adjustable shelves (06402) Soap dispenser (10801) Sink/faucet, Re: Plumbing Paper towel dispenser (10801) Finished End Integral sheet vinyl cove base, Re: Room Finish Schedule (09652) 1824 Finished End Gypsum board soffit, paint (09260) 3' - 0" 1' - 11" 3' - 0" 1" 8' - 0" 4214 3614 3624 Finished end A21 A4 2' - 1" Locks (01402) Checked By Drawn By Project Number: c Copyright 2012 KEY PLAN 817 Wyandotte Kansas City, MO 64105 816 421 8200 p 816 421 1262 f designwithinsight.com Gastinger Walker Harden Architects ISSUED FOR: A 13 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 23 45678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 B C D E F G H J K L M N P Q R R Q P N M L K J H G F E D C B A Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 C:\Documents and Settings\jkyger\Desktop\2012.105 SurgCenter Carmel Meridian_JKy.rvt A3 Interior Elevations JKy JBT 2012.105 PKMR Engineers 8801 Ballentine, Suite 200 Overland Park, KS 66214 913.492.2400 / 2437 fax Wiegmann Associates, Inc. 750 Fountain Lakes Blvd. St. Charles, MO 63301 314.409.3350 Bob D. Campbell & Co. 4338 Belleview Kansas City, MO 64111 816.531.4144 Cripe Architects + Engineers 3939 Priority Way South Drive, Suite 400 Indianapolis, IN 46240 317.844.6777 Vive Exterior Design 15325 Herriman Blvd. Noblesville, IN 46060 317.773.9933 Zoning Review 4/20/2012 TI Permit 5/7/2012 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.3757 / f 866.760.3757 Tenant Improvement Carmel Specialty Surgery Center Electrical / Plumbing Mechanical Structural Civil Landscape A1 1/2" = 1'-0" A1 Elevation @ Clean Workroom A1 1/2" = 1'-0" A8 Elevation @ Solied Workroom A1 1/2" = 1'-0" M22 Elevation @ Clinic Sink A2 1/2" = 1'-0" M1 Elevation @ Lounge A1 1/2" = 1'-0" M8 Elevation @ OR A1 1/2" = 1'-0" M17 Elevation @ Procedure A1 1/2" = 1'-0" G1 Elevation @ Nutrition A1 1/2" = 1'-0" G6 Elevation @ Patient Lockers A2 1/2" = 1'-0" G10 Elevation @ Staff Lockers A2 1/2" = 1'-0" A19 Elevation @ Toilet A2 1/2" = 1'-0" A15 Elevation @ Toilet A2 1/2" = 1'-0" G14 Elevation @ Shower A2 1/2" = 1'-0" G18 Elevation @ Nurse Station Copy 102 Sterile Corridor 126 Lounge 103 Vacuum 104 Exit Corridor 105 Patient Toilet 106 Step-Down Recovery 107 Procedure 108 Office 109 Office 110 Consultation 111 Hall 112 Janitor 125 EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ 2' - 1" 2' - 1" 2' - 8" 4' - 0" 4' - 0" 1' - 0" EQ EQ 2' - 6" EQ 1' - 8" EQ EQ 1' - 8" 2" EQ. 10' - 0" 8' - 6" 9' - 0" 9' - 0" 9' - 0" 10' - 0" 10' - 0" 9' - 0" 10' - 0" 9' - 0" 8' - 0" 8' - 0" 10' - 0" 10' - 0" 9' - 0" Sterile Corridor 126 10' - 0" 10' - 0" 8' - 0" 8' - 0" 8' - 0" 10' - 0" 10' - 0" 10' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 10' - 0" 9' - 0" 9' - 0" 8' - 0" 8' - 0" 6' - 9" 8' - 0" 9' - 0" 9' - 0" 9' - 0" 10' - 0" 9' - 0" 8' - 0" 8' - 0" 6' - 9" 9' - 6" 9' - 6 1/2" 10' - 0" 9' - 0" 9' - 0" 9' - 0" 8' - 11" 9' - 11 1/2" 8' - 0" 8' - 0" 8' - 0" 8' - 0" N1 A2 N1 A2 N6 A2 A12 A5 8' - 0" 2' - 0" 4' - 11" 4' - 11" 2" 4' - 5" 2' - 7 1/2" 3' - 7" 5' - 0" 9' - 5" 1' - 10" Verify 3' - 2" 3' - 9" 2' - 1 1/2" 132 1 130 1 129 1 131 1 129 2 101 2 102 1 133 1 9' - 5" 60"x56" clear floor area (toilet) 30"x48" clear floor area (lavatory) 36"x48" clear floor area (shower) Staff Lockers Accessible shower, typ. Re: plumbing Sink, typ. Re: plumbing 60"x56" clear floor area (toilet) 30"x48" clear floor area (lavatory) Staff Corridor 129 Staff Dress 132 Staff Dress 130 Waiting 101 Reception/ Copy 102 Staff Shower 131 Staff Shower 133 A3 G10 A3 G10 A19 A3 A15 A3 G14 G14 A3 A19 A15 sim A4 E1 A4 E7 A3 M1 Lounge 103 8' - 10 1/2" Staff Lockers 5' - 9" 3' - 0" 3' - 8 1/2" 6' - 1" 5' - 11" 5' - 0" 8' - 0" 3' - 7" 7' - 10 1/2" 1' - 6" 1' - 5" 1' - 8" 5' - 9 1/2" 3' - 0" 2' - 1" 1' - 8" 4' - 2" 1' - 0" 1' - 4 1/2" REF 1' - 0" 1' - 0" 10' - 8" 10' - 4" 3' - 7" 2' - 9" Accessible toilet, typ. Re: plumbing Operating Room 2 128 Operating Room 1 127 Patient Toilet 106 Sterile Supplies 121 Equipment Storage 124 Clean Workroom 122 Soiled Workroom 123 Electrical 120 #1 #2 #3 #4 #5 #6 #7 #8 Procedure 108 Staff Toilet 117 Clean Linen 116 Soiled Linen 115 PACU 113 Office 109 Private Recovery 118 Staff Dress 130 Step-Down Recovery 107 Sterile Corridor 126 Janitor 125 Med Gas 119 Lounge 103 Reception/ Copy 102 Consultation 111 Office 110 Nurse's Station 114 Waiting 101 Exit Corridor 105 Building Mechanical (no work) Vacuum 104 Hall 112 Staff Shower 131 Staff Dress 132 Staff Shower 133 Staff Corridor 129 SV-1: Field (09652) SV-2: Accent (09652) SV-3: Accent (09652) Wall Finish Legend: Flooring Legend: Wallcovering (09720) Fiberglas Reinforced Panels (FRP) (10260) Re: Room Finish Schedule for more information. 1' - 0" EQ 5' - 0" EQ 1' - 0" EQ 3' - 0" EQ 1' - 0" EQ 5' - 0" EQ 1' - 0" 1' - 0" 3' - 0" 1' - 0" 1' - 0" 3' - 0" 1' - 0" 2' - 0 1/2" Accent paint (09910) 3' - 0" EQ 1' - 0" EQ 1' - 0" 3' - 0" 1' - 0" 1' - 0" EQ 1' - 0" EQ 1' - 0" 3' - 0" 1' - 0" 2' - 8 1/2" 4' - 0" Align FRP 9' - 10" 8' - 11" 6' - 11" 4' - 8" 5' - 7 1/2" 6' - 4" 10' - 10" 8' - 3" 11' - 11" 10' - 4" Blanket Warmer (OF/CI) Undercounter Regrigerator (OF/CI) Clean Linen 116 Soiled Linen 115 Nurse's Station 114 Staff Toilet 117 Accessible toilet, typ. Re: plumbing Sink, typ. Re: Plumbing 60"x56" clear floor area (toilet) 30"x48" clear floor area (lavatory) 116 1 115 1 117 1 1' - 8" A4 K8 A4 K1 A3 G18 A3 A19 A15 3 2A 3 1B 3' - 7" 1' - 6" 2A 2 2 Patient Toilet 106 7' - 10" 8' - 1 1/2" Accessible toilet, typ. Re: plumbing Sink, typ. Re: plumbing 30"x48" clear floor area (lavatory) 106 1 A3 A15 A19 60"x56" clear floor area (toilet) Light fixture beyond; refer to ceiling plan, electrical 5/8" gypsum board, paint (09260) 3 5/8" metal stud framing @ 24" o.c.; brace to structure above. (09260) Acoustical lay-in ceiling, refer to reflected ceiling plan (09511) Bottom of soffit Re: Ceiling Plan 6" Re: Ceiling Plan Varies Min. 6" 3 5/8" metal stud framing to deck above @ 16" o.c. 5/8" gypsum board, paint (09260) Acoustical lay-in ceiling (09511), refer to ceiling plan Acoustical lay-in ceiling (09511), refer to ceiling plan Provide metal corner bead, typ. Brace to structure above 4'-0" o.c. Re: Ceiling Plan Varies Checked By Drawn By Project Number: c Copyright 2012 KEY PLAN 817 Wyandotte Kansas City, MO 64105 816 421 8200 p 816 421 1262 f designwithinsight.com Gastinger Walker Harden Architects ISSUED FOR: A 13 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 23 45678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 B C D E F G H J K L M N P Q R R Q P N M L K J H G F E D C B A Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 C:\Documents and Settings\jkyger\Desktop\2012.105 SurgCenter Carmel Meridian_JKy.rvt A2 Finish, Reflected Ceiling, & Enlarged Plans JKy JBT 2012.105 PKMR Engineers 8801 Ballentine, Suite 200 Overland Park, KS 66214 913.492.2400 / 2437 fax Wiegmann Associates, Inc. 750 Fountain Lakes Blvd. St. Charles, MO 63301 314.409.3350 Bob D. Campbell & Co. 4338 Belleview Kansas City, MO 64111 816.531.4144 Cripe Architects + Engineers 3939 Priority Way South Drive, Suite 400 Indianapolis, IN 46240 317.844.6777 Vive Exterior Design 15325 Herriman Blvd. Noblesville, IN 46060 317.773.9933 Zoning Review 4/20/2012 TI Permit 5/7/2012 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.3757 / f 866.760.3757 Tenant Improvement Carmel Specialty Surgery Center Electrical / Plumbing Mechanical Structural Civil Landscape NORTH 02'4' 8' NORTH 1/8" = 1'-0" 02'4' 8' A11 First Floor Ceiling Plan A1 1/4" = 1'-0" 1 Enlarged Plan @ Reception 1/8" = 1'-0" J11 First Floor Finish Plan A1 1/4" = 1'-0" G1 Enlarged Plan @ Nurse Station A1 1/4" = 1'-0" G8 Enlarged Plan @ Patient Toilet NORTH NORTH NORTH 01'2' 4' 01'2' 4' 01'2' 4' A2 1" = 1'-0" N1 Detail @ Soffit A2 1 1/2" = 1'-0" N6 Detail @ Header Operating Room 2 128 Operating Room 1 127 101 1 Patient Toilet 106 129 2 125 1 101 2 117 1 116 1 115 1 122 1 121 1 Sterile Supplies 121 Equipment Storage 124 Clean Workroom 122 123 Soiled 1 Workroom 123 124 1 Electrical 120 110 1 109 1 #1 #2 #3 #4 #5 #6 #7 #8 Procedure 108 Staff Toilet 117 Clean Linen 116 Soiled Linen 115 PACU 113 Office 109 Private Recovery 118 Staff Dress 130 112 1 New sidewalk to public way Step-Down Recovery 107 Sterile Corridor 126 First Floor Elevator Lobby (provides access to public toilets and drinking fountain) Ref Janitor 125 Med Gas 119 Lounge 103 Lockers 102 1 Reception/ Copy 102 111 1 Consultation 111 Office 110 Nurse's Station 114 Waiting 101 Exit Corridor 105 Building Mechanical (no work) Vacuum 104 Access to public toilets and drinking fountain 104 1 Hall 112 Occupied tenant space, no work this area. Building Mechanical (no work) Occupied tenant space, no work this area. Stretcher Storage Min. 5' - 0" 4' - 0" 4' - 0" Staff Shower 131 Staff Dress 132 Staff Shower 133 Staff Corridor 129 6' - 6" 3' - 6 1/2' 2" - 11 1/2" 7' - 11" 6' - 0" 1B 1' - 8" Existing Public Corridor Lobby Egress 1' - 7" 113 1 119 1 120 1 1' - 6" 4' - 0" 129 1 130 1 131 132 1 1 133 1 103 1 106 1 105 1 3' - 0" A2 G1 A2 1 A2 G8 14' - 5 1/2" 3 3 2 2A 2A 2A 2 2B 2 2 2 2A 2A 1B 2A 1B 1B 1B 1B 2 2 5 2 1B 2 1B 1B 2 2 2 1B 2 2 2 2 1B 1B 2 1B 1B 2 2 2 2 1B 1B 1B 2 2 2 2 2 1B 1B 4 4 2 2 2 2 2 2 2 2 1B 1B 1B 1B 1B 1B 2 2 1B 1B 2 2 2 2 2 2 2 2 2 2 2A 2A 3 3 1B 2 1B 2 2B 2B 3 3 3 3 6 6 6 6 6 6 6 6 1B 1B 3 3' - 0" 2 New 1 hour fire/smoke barrier full height Existing corridor wall to remain New 1 hour fire/smoke barrier full height Existing sidewalk to remain 118 1 20' - 1" 11' - 9" 7' - 4" Door activator, typ. 7' - 9" 8' - 3 1/2" 6' - 8" 11' - 4" 11' - 5" 23' - 1 1/2" 22' - 11 1/2" 11' - 1 1/2" 8' - 8" 15' - 1 1/2" Verify 3' - 5" Verify 2' - 8" 9' - 1" 9' - 5" 10' - 0" 5' - 6" 2' - 6" 1' - 3" 1' - 7" 2' - 2" 18' - 6 1/2" 9' - 11" 4' - 10" Align partition with center of mullion Reomve and replace damaged glazing to match existing 14' - 9 1/2" Align partition with center of mullion 6' - 2 1/2" 2' - 11" TV TV 12' - 0" 12' - 10" 14' - 7 1/2" 8' - 1" 11' - 6" 19' - 1" 6' - 1" 2' - 5" Patient Exit 405 SF Operating Room 2 128 406 SF Operating Room 1 127 Patient Toilet 106 Sterile Supplies 121 Equipment Storage 124 Clean Workroom 122 Soiled Workroom 123 Electrical 120 #1 #2 #3 #4 #5 #6 #7 #8 Procedure 108 Staff Toilet 117 Clean Linen 116 Soiled Linen 115 PACU 113 Office 109 Private Recovery 118 Staff Dress 130 New sidewalk to public way Step-Down Recovery 107 Sterile Corridor 126 Nutrition First Floor Elevator Lobby (provides access to public toilets and drinking fountain) Janitor 125 Med Gas 119 Lounge 103 Reception/ Copy 102 Consultation 111 Office 110 Nurse's Station 114 Waiting 101 Exit Corridor 105 Building Mechanical (no work) (8'-8"x13') Vacuum 104 Hall 112 Blanket Warmer (OF/CI) Undercounter Regrigerator (OF/CI) Scrub sinks (OF/CI), re: Plumbing Cubicle curtain track (10190) Horizontal bumper guard, typ. (10260) Copier (OF/OI) Wall mounted television (OF/CI) @ 82" A.F.F. to bottom Ultrasonic Cleaner (OF/CI) Recessed film illuminator, 65" A.F.F. to center (OF/CI) Push Button (08711), Re: Electrical Vertical wall bumpers, typ. (10260) ADA Shower, Re: Plumbing Large Sterilizer (OF/OI) Small Sterilizer (OF/OI) Ref. (OF/CI) Staff Lockers Janitor's Sink, Re: Plumbing Ice Maker (OF/CI) Recessed film illuminator, 65" A.F.F. to center (OF/CI) Existing Building Corridor Patient Lockers Corner guard, typ. (10260) Stretcher Storage Staff Shower 133 Staff Dress 132 Staff Corridor 129 Staff Shower 131 ADA Shower, Re: Plumbing Staff Lockers Push Button (08711), Re: Electrical Undercounter Regrigerator (OF/CI) 5' - 7" 8' - 0" 5' - 6" 5' - 6" 8' - 0" 8' - 0" 5' - 6" 5' - 6" 8' - 0" 5' - 7" EQ EQ A2 G1 A2 1 A2 G8 A4 A1 A4 1 M8 A3 Bedpan hopper; A3 M8 Re: Plumbing A3 A1 A3 A8 M22 A3 G1 M17 A3 G6 A3 A1 F1 A1 F5 A1 A1 F1 F5 A1 K5 A1 K1 Blinds set in closed position (12491) 1/2" Treated plywood, (paint black) with vapor barrier on outside face (06105) Metal stud partition per plan (09260) Existing window system to remain Spray foam insulation, thickness as specified (07210) Existing window system to remain Align Blinds set in closed position (12491) 1/2" Treated plywood, (paint black) with vapor barrier on outside face (06105) Metal stud partition per plan (09260) Spray foam insulation, thickness as specified (07210) Continuos sealant joint (07920) Existing demising wall to remain Existing window system to remain New 1 hour shaft wall per plan Type 'X' gypsum wall board Metal wall track, paint to match wall 6 Existing window system to remain Align Metal wall track full height, paint to match wall Metal stud partition per Continuous plan sealant full height Checked By Drawn By Project Number: c Copyright 2012 KEY PLAN 817 Wyandotte Kansas City, MO 64105 816 421 8200 p 816 421 1262 f designwithinsight.com Gastinger Walker Harden Architects ISSUED FOR: A 13 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 23 45678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 B C D E F G H J K L M N P Q R R Q P N M L K J H G F E D C B A Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 C:\Documents and Settings\jkyger\Desktop\2012.105 SurgCenter Carmel Meridian_JKy.rvt A1 Demolition, Dimension, & Equipment Floor Plans JKy JBT 2012.105 PKMR Engineers 8801 Ballentine, Suite 200 Overland Park, KS 66214 913.492.2400 / 2437 fax Wiegmann Associates, Inc. 750 Fountain Lakes Blvd. St. Charles, MO 63301 314.409.3350 Bob D. Campbell & Co. 4338 Belleview Kansas City, MO 64111 816.531.4144 Cripe Architects + Engineers 3939 Priority Way South Drive, Suite 400 Indianapolis, IN 46240 317.844.6777 Vive Exterior Design 15325 Herriman Blvd. Noblesville, IN 46060 317.773.9933 Zoning Review 4/20/2012 TI Permit 5/7/2012 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.3757 / f 866.760.3757 Tenant Improvement Carmel Specialty Surgery Center Electrical / Plumbing Mechanical Structural Civil Landscape 1/16" = 1'-0" A1 First Floor Demolition Plan 1/8" = 1'-0" J10 First Floor Dimension Plan NORTH 02'4' 8' NORTH 1/8" = 1'-0" 02'4' 8' A10 First Floor Equipment Plan 0 4' 8' 16' NORTH A1 1 1/2" = 1'-0" F1 Detail at Exterior Wall A1 1 1/2" = 1'-0" F5 Detail at Window A1 1 1/2" = 1'-0" K5 Detail at Rated Wall A1 1 1/2" = 1'-0" K1 Detail at Office Mullion Accessibility Code - 2009 International Building Code (ICC/ANSI A117.1-2003) Fire Code - 2006 International Fire Code with 2008 Indiana Amendments Chapter 20 of NFPA 101, Life Safety Code, 2006 edition (State) Chapter 20 of NFPA 101, Life Safety Code, 2000 edition (Federal) 2001 AIA Guidelines for Design and Construction of Health Care Facilities Applicable City Ordinances: City Code of Carmel, Indiana Building Data: Zoning Classification: B-3/S-2 Occupancy Type: B, Business Occupancy Type (2000 NFPA-101): Ambulatory Health Care Construction Type: II Building Height: 80 feet / 6 stories Automatic Sprinkler System: Fully sprinklered Building Area: 159,000 SF 1 hour separation provided between ASC occupancy and adjacent tenant (per NFPA 101, 20.3.7.1) Project Area: 6,467 SF Occupant Load: Office (Business areas) = 5,947 sf /100 sf = 59.5 = 60 Occupants Waiting Room (Assembly w/o fixed seats, unconcentrated) = 389 sf / 15 sf = 25.9 = 26 Occupants Staff Lounge (Assembly w/o fixed seats, unconcentrated) = 131 sf / 15 sf = 8.7 = 9 Occupants Total = 95 Occupants Exit Access: Travel Distance (NFPA 101, 20.2.6.2) (1) The travel distance between any room door required as an exit access and an exit shall not exceed 150 ft. (50 ft increase allowed with automatic sprinkler system). (2) The travel distance between any point in a room and an exit shall not exceed 200 ft. (50 ft increase allowed with automatic sprinkler system). Exits required (NFPA 101, 20.2.4.1) = 2 Exits Provided = 3 Egress Width: 44 in. min required & provided at corridors and passageways (NFPA 101, 20.2.3.2) 0.2 in. (Healthcare, sprinklered) x 90 occupants = 18.0 in. required / 120 in. provided Accessibility: Construction has been designed to meet the minimum requirements of the Americans with Disabilities Act (ADA) of 1992 and ANSI 117.1-2003. Fire Extinguishers Portable Fire Extinguishers are required (and provided) in all B occupancies and shall be located such that the travel distance to reach an extinguisher does not exceed 75 feet (NFPA 10). I, Kirk A. Gastinger, FAIA, Indiana registered Architect #AR19600070, do hereby accept professional responsibility for the attached architectural drawings (numbered A0 - A5) and specification Divisions 1-10, and 12. I hereby disclaim any responsibility for all other drawings included in these construction documents, they being the responsibility of the design professionals whose names and signed statements appear hereinafter. I, Jerot Vance Pearson, PE, Indiana registered Engineer #PE10403240, do hereby accept professional responsibility for the attached engineering drawings (numbered PE1-PE3, P1-P4, and E1-E6) and specification Divisions 15 and 16. I hereby disclaim any responsibility for all other specifications included in these construction documents, they being the responsibility of the design professionals whose names and signed statements appear hereinafter. 101 - Door Number North Arrow Room Name Room Number Graphic Scale Detail Number Origin Sheet Number Scale Detail Number Sheet Number Elevation Mark Detail Reference Detail Number Sheet Number Interior Detail Elevation Number Sheet Number 1 Revision Reference 9' - 0" Ceiling Height A Wall Tag Fluorescent Light Fixture, Re: Electrical Recessed Can Light Fixture, Re: Electrical Annotations and Symbols Section Reference A1 30.01 A1 30.01 View Name 1/8" = 1'-0" View Title NORTH Name Elevation 02'4' 8' A1 30.01 ROOM NAME 101 Horizontal Wall Guards (10260) Corner Guards (10260) OF/CI - Owner Furnished/Contractor Installed OF/OI - Owner Furnished/Owner Installed CF/CI - Contractor Furnished/Contractor Installed N.I.C. - Not in Contract G1 A1 A1 Fire Extinguisher Cabinet (10520) Mount top at 5'-0" AFF FEC Light Fixture Symbols Existing Wall New Wall Fire-Rated Wall Wall to be Removed General Notes 1. Do not scale these drawings for construction purposes. In the event of omission of necessary dimensions, the contractor shall notify the construction manager. 2. All dimensions on 1/8" and 1/4" scale plans are to outside face of gypsum board unless noted otherwise. 3. All gypsum board partition dimensions are nominal unless noted otherwise. Verify all dimensions and conditions at the job site. Notify the architect in writing of any discrepancies or conflicts. 4. Verify size, location, and characteristics of all work and equipment to be installed (whether furnished by owner or by contractor(s)) before any construction pertaining to same is started. 5. Verify and coordinate the size and location of all openings for structural, mechanical, and electrical work and equipment with all trades involved. 6. Ceiling heights indicated on the reflected ceiling plans are taken from the finished floor elevation. The size, location, and characteristics of all MEP and structural items shall be verified before ceiling construction is started. 7. Coordinate with all trades in order to maintain scheduled ceiling heights. Verify that required operations and maintenance clearances are provided for all equipment items. 8. Install all items in accordance with the manufacturer's written instructions except where the drawings are more stringent. Notify the architect in writing of any conflicts. 9. Perform all work in accordance with applicable local codes and ordinances and under requirements established by general conditions of the contract. 10. Secure all permits and approvals as required by authorities having jurisdiction and utility companies prior to beginning work. 11. Remove rubbish from premises as often as necessary or as directed in order to keep premises clean and exit ways clear. Provide complete and thorough cleaning periodically as the work progresses and upon completion of construction.12. Install work readily accessible for operation, maintenance, and repairs. 13. Drawings are prepared to scale unless noted NTS (not to scale) 16. The location and dimension of the existing architectural, structural, and MEP elements are taken from job site surveys. Field verification is required by the contractor prior to any construction involving these items. 17. All shop drawings shall be submitted to the architect for review prior to fabrication or purchasing. 18. At project completion, provide the owner with a set of as-built drawings indicating all field changes, additions or deletions made during construction. 19. Provide fire treated wood blocking at all items attached to wall surface, (i.e. Equipment (owner-furnished and contractor furnished), door stops, grab bars, toilet accessories, TV's, millwork, etc. (06105) 20. All penetrations through fire-rated assemblies are to be sealed with U.L. approved fire-rated sealant and assemblies. 21. The General Contractor shall provide and install horizontal window blinds (12491) at all exterior windows within the tenant space. Windows obscured by gypsum board partitions shall have the blinds installed in the closed position. Install Visqueen (or approved equal) vapor barrier over the existing window; tape all edges, typical. 22. It is the responsibility of the contractor to construct all U.L. rated assemblies as detailed in current U.L. Assembly Manuals. Descriptions listed on drawings are for reference only. Full detailed descriptions are available by request. 23. Areas immediately adjacent to the area of this work will be occupied during the demolition and construction work. Contractor shall provide protection for users of the surrounding areas. Contractor shall provide protection from the spread of dust and dirt during the entire demolition and construction period. 24. The Contractor shall verify the existing demising partition assembly for compliance with the required 1-hour rating. If the existing demising partition does not meet this requirement, the Contractor shall revise and/or rebuild the demising partition as required to meet the required 1-hour rating separation. 25. For under cabinet lighting locations, refer to interior elevations and electrical drawings. 26. On all fire-rated partitions and smoke partitions stencil on "FIRE AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS" on the partition above the finished ceiling (both sides) with 2" high letters at 5'-0" O.C. unless otherwise regulated by the state or local municipality. Structural Scope of Work: 1. General Contractor shall retain a structural engineer to analyze and design support detailing for the following scopes of work: a. Surgical light fixture support framing. b. Structural equipment supports. c. Other items requiring structural analysis not defined in the documents. W 116th St. Project Site W 106th St. Springmill Rd. Keystone Pkwy N Meridian St. I-465 W Main St. Towne Rd. 5/8" Gypsum Board (09260) 3 5/8" Metal Stud (09260) Acoustical Insulation (09260) 5/8" Gypsum Board (09260) Acoustical Tile Ceiling System (09511) Finish Floor Finish Ceiling 1 As stated above. WALL TYPE "1" Acoustical Insulation (09260) Description: 3 5/8" Metal studs at 24" on center (o.c.) maximum, up to 6" above higher finished ceiling. Brace to structure w/ 3 5/8" metal studs at 4'-0" o.c. alternating sides. Four foot wide, 5/8" gypsum board on each side of studs. Acoustical batt insulation between studs. Use water resistant gypsum board at all sink and/or operating room side of walls. Brace to deck at 4'-0" o.c. alt. sides Interior Non-Load Bearing Partition 6" 1B 1C As stated above with gypsum board on one side only As stated above with 1 5/8" metal studs at 24" max. o.c. and gypsum board on one side only, no acoustical batt insulation. Base per Finish Schedule (09 ) Description: 3 5/8" metal stud, 24" o.c. max., up to underside of gypsum Deck. Four foot wide, 5/8" gypsum board on either side of stud. Acoustical batt insulation between studs, full height of wall. On room side of wall, continue gypsum board to underside of gypsum. Use acoustical sealant to seal around openings and penetrations. At all walls in height 12'-0" and above, use 20ga. metal studs. Slip joint shall be installed at bottom of joist or to bottom of deck. ***At all sink or operation room sides of walls, use 5/8" water resistant gypsum board. 2 As stated above Acoustical Insulation (09260) 5/8" Gypsum Board (09260) 3 5/8" Metal Stud (09260) Finish Floor Acoustical Insulation (09260) Finish Ceiling Finish Ceiling Bottom of deck WALL TYPE "2" Interior Non-Load Bearing Partition 5/8" Gypsum Board (09260) Acoustical Tile Ceiling System (09511) Slip track attachment (09260) Continuous sealant 2A As stated in Type '2', smoke resistive partition 4" ROOM SIDE * At all smoke partitions, provide text above finished ceilings at each wall face and no more than 20 feet on center along wall, 4" high red stencil painted lettering stating: "SMOKE PARTITION. PROTECT ALL OPENINGS". (09910) 2B As stated in Type '2', except substitute 6" metal studs @16" o.c. 2C As stated in Type '2A', except substitute 6" metal studs @16" o.c., smoke resistive partition [4] - 5/8" Gypsum Board (09260) [2] - 3 5/8" Metal Stud (09260) Acoustical Insulation (09260) [4] - 5/8" Gypsum Board (09260) Acoustical Tile Ceiling System (09511) Finish Floor Finish Ceiling 3 As stated above WALL TYPE "3" Design No. U.L. U465 Interior Non-Load Bearing Wall Rating - 1 HR [3] - Acoustical Insulation (09260) Slip track attachment with deep leg track (09260) Description: 1. Floor and Ceiling Runners Channel-shaped runners, 3 5/8" wide, 1 1/4" legs, formed from No. 25 MSG min galv. steel, attached to floor and ceiling with fasteners spaced 24" o.c. max. 2. Steel Studs - Channel shaped, 3 5/8" wide (min) by 1 1/4" deep with 3/8" folded back return flange legs. Fabricated from No. 25 MSG (min) galv. steel. Max stud spacing 24" o.c. 3. Batts - Acoustical insulation placed to completely fill interior of stud cavity, 3" min. thickness. 4. Gypsum board - 5/8" thick, 4 ft. wide, attached to steel studs and floor and ceiling track with 1" long, Type S steel screws spaced 8" O.C. along edges of board and 12" O.C. in the field of the board. Joints oriented vertically and staggered on opposite sides of the assembly. 5. Joint Tape and Compound (not shown) - Vinyl, dry or premixed joint compound, applied in two coats to joints and screw heads; paper tape, 2" wide, embedded in first layer of compound over all joints. Note: It is the contractors responsibility to verify and meet the specific requirements of this U.L. assembly. The description above is for general purposes only. Bottom of Deck Continuous sealant * At all fire-rated partitions, provide text above finished ceilings at no more than 8 feet on center, 4" high red stencil painted lettering stating: "FIRE-RATED PARTITION. SEAL ALL PENETRATIONS". (09910) Med Gas Electrical PACU Nurse's Station Clean Linen Soiled Linen Staff Toilet Sterile Supplies Private Recovery Clean Workroom Soiled Workroom Equipment Storage 406 SF Operating Room 1 405 SF Operating Room 2 Sterile Corridor Staff Corridor Waiting Vacuum Exit Corridor Lounge Patient Toilet Step-Down Recovery Reception/ Copy Staff Shower Staff Dress Staff Dress Staff Shower Consultation Office Office Procedure Janitor Egress Path 1-Hour Rated Construction - UL Design #U465 Life Safety Legend Maximum Length Egress (105'-0") FEC Fire Extinguisher Cabinet Smoke Resistive Partitions Note: Fire rating of existing floor/ceiling assemblies shall be maintained. EXIT (36" width) EXIT (36" width) EXIT (48" width) New 1-Hour Demising Wall UL Design #U465 1-Hour Fire-rated Wall at Med Gas UL Design #U465 1-Hour Smoke Partition at Sterile Storage 1 Hour Fire/Smoke Partition at Soiled Linen 1-Hour Fire-rated Wall at Vacuum UL Design #U465 New 1-Hour Fire/Smoke Barrier UL Design #U465 1-Hour Smoke Partition at Equipment Storage Existing Building Corridor Existing Building Tenant N.I.C. Existing Building Tenant N.I.C. (Class C) (Class C) (Class A) FEC FEC New 1-Hour Fire/Smoke Barrier UL Design #U465 Smoke Partition at Clean Linen WALL TYPE "4" 4 As stated above Design No. U.L. U419 Interior Non-Load Bearing Wall Rating - 1 HR and Sound Partition 1 layer 5/8" Gypsum Board (09260) Description: Resilient channels 24" o.c. attached at right angles to one side of 3 5/8" 20ga. steel studs @ 24" o.c. with one 1/2" type S-12 drywall screw at each stud. Face layer 5/8" gypsum wallboard or gypsum veneer base applied at right angles to channels with 1 5/8" type S drywall screws 12" o.c. 3" acoustical insulation. Friction fit in stud space. Opposite side: one layer 5/8" gypsum wall board applied parallel to studs with 1" type S-12 drywall screws 12" o.c. joints staggered 24" each layer and side. Attach wall to underside of 1-hour ceiling assembly (on underside of wood truss) above with slip track. Seal top and bottom with acoustical sealant. Note: It is the contractors responsibility to verify and meet the specific requirements of this U.L. assembly. The description above is for general purposes only. 3" Acoustical Insulation (07210) Resilient channel (09260) 5 3/8" 3 5/8" Metal Studs (09260) 4A As stated above, add 1-layer 5/8" Gyp over resilient channel to existing or new fire rated partition 5/8" Gypsum Board (09260) 3 5/8" Metal Stud (09260) Acoustical Insulation (09260) 5/8" Gypsum Board (09260) Acoustical Tile Ceiling System (09511) Finish Floor Finish Ceiling Description: 3 5/8" metal stud at 24" max. o.c., to 6" above higher ceiling, opposite 3 5/8" metal stud to structure above. Four foot wide, 5/8" moisture resistant gypsum board on room sides of studs; one side to 6" above highest ceiling and opposite side to underside of deck. Acoustical batt insulation between studs. At all walls in height 12'-0" and above, use 20ga. metal studs. 5 As stated above WALL TYPE "5" Interior Non-Load Bearing Partition, Double Stud 6" Continuous sealant (09260) 9" Structure above 7 1/2" Slip track attachment (09260) 1" Gypsum Board (09260) [2] - "C-H" shaped metal stud (09260) [4] - Gypsum Board (09260) Acoustical Tile Ceiling System (09511) Finish Floor Finish Ceiling Description 1. Channel Track - 'J'-shaped channel, 2 1/2" deep with unequal legs of 1" and 2", fabricated from No. 25 MSG galv steel. Channel positioned with short leg toward finished side of wall. Channel attached to structural supports with steel fasteners located not greater than 2" from ends and not greater than 24" o.c. 2. Steel Studs - 'C-H'-shaped studs, 2 1/2" deep by 1 1/2" wide, fabricated from No. 25 MSG galv steel. Cut to lengths 3/8" less than floor to ceiling height and spaced 24" o.c. 3. Gypsum Board* - 1" thick gypsum wallboard liner panels, supplied in nom 24" widths. Panels cut 1" less in length than floor to ceiling heights. Vertical edges inserted in 'C-H' studs. Free edge of end panels attached to long leg of channel track with 1 5/8" long Type S steel screws spaced not greater than 12" o.c. 4. Gypsum Board* - 5/8" thick, 4ft. wide wallboard applied vertically and attached to studs with 1" long Type S steel screws spaced 12" o.c. along the edges and in the field of the boards. Joints covered with paper tape and joint compound. Exposed screw heads covered with joint compound. * Bearing the UL Classification mark 6 As stated above. (Refer to International Code Council Evaluation Service Legacy Report NER-258 describing approved installation for horizontal assemblies.) WALL TYPE "6" Design No. U.L. 469 Interior Non-Load Bearing Wall Rating - 1 HR [1] - Channel Track (09260) [1] Channel Track (09260) [3] - Gypsum Board liner panel (09260) Note: It is the contractor's responsibility to verify and meet the specific requirements of this U.L. assembly. The description above is for general purposes only. * At all fire-rated partitions, provide text above finished ceilings at no more than 8 feet on center, 4" high red stencil painted lettering stating: "FIRE-RATED PARTITION. SEAL ALL PENETRATIONS." (09910) Checked By Drawn By Project Number: c Copyright 2012 KEY PLAN 817 Wyandotte Kansas City, MO 64105 816 421 8200 p 816 421 1262 f designwithinsight.com Gastinger Walker Harden Architects ISSUED FOR: A 13 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 23 45678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 B C D E F G H J K L M N P Q R R Q P N M L K J H G F E D C B A Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 C:\Documents and Settings\jkyger\Desktop\2012.105 SurgCenter Carmel Meridian_JKy.rvt A0 Cover Sheet JKy JBT 2012.105 PKMR Engineers 8801 Ballentine, Suite 200 Overland Park, KS 66214 913.492.2400 / 2437 fax Wiegmann Associates, Inc. 750 Fountain Lakes Blvd. St. Charles, MO 63301 314.409.3350 Bob D. Campbell & Co. 4338 Belleview Kansas City, MO 64111 816.531.4144 Cripe Architects + Engineers 3939 Priority Way South Drive, Suite 400 Indianapolis, IN 46240 317.844.6777 Vive Exterior Design 15325 Herriman Blvd. Noblesville, IN 46060 317.773.9933 Zoning Review 4/20/2012 TI Permit 5/7/2012 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.3757 / f 866.760.3757 Tenant Improvement Carmel Specialty Surgery Center Electrical / Plumbing Mechanical Structural Civil Landscape Not to Scale L21 Drawing Index Not to Scale D18 Code Summary No Scale A21 Professional Disclaimers Not to Scale Symbols Legend Not to Scale A18 Location Map 1" = 1'-0" L1 Wall Type 1 - Interior Partition 1" = 1'-0" L5 Wall Type 2 - Interior Partition 1" = 1'-0" L9 Wall Type 3 - Interior 1-HR Rated 1" = 10'-0" A1 First Floor Life Safety Plan 02'4' 8' NORTH NORTH 1" = 1'-0" N14 Wall Type 4 - Interior Sound Wall 1-HR 1" = 1'-0" H14 Wall Type 5 - Double Wall 1" = 1'-0" A14 Wall Type 6 - Shaft Wall E21