HomeMy WebLinkAboutB2' -0" , 2' -0" CEILING LINE w SOUND BATT INSULATION BASE AS SCHEDULED 2�" METAL STUDS AT 16" O.C. ONE LAYER J" TYPE "X" GYPSUM WALL BOARD ON EACH SIDE. USE (MR) MOISTURE RESISTANT WALL BOARD WITHIN 5' OF WET FIXTURES EXTEND WALL TO UNDERSIDE OF FINISHED CEILING. SOUND BATT INSULATION INSIDE WALL AND 2' EITHER SIDE ABOVE CEILING. MATCH THICKNESS OF EXISTING STUDS AT DOOR INFILLS. NOTE: NEW INTERIOR WALLS TO BE WALL TYPE 'W1' WALL TYPE 'W1' WALL TYPES SCALE: 11/4"=V-0" METAL DECK CEILING LINE SOUND BATT INSULATION BASE AS SCHEDULED 3J" METAL STUDS AT 16" O.C. ONE LAYER �" TYPE "X" GYPSUM WALL BOARD ON EACH SIDE. USE (MR) MOISTURE RESISTANT WALL BOARD WITHIN 5' OF WET FIXTURES EXTEND WALL TO UNDERSIDE OF METAL DECK. SOUND BATT INSULATION INSIDE WALL TO DECK. MATCH THICKNESS OF EXISTING STUDS AT DOOR INFILLS. NOTE: DEMISING WALLS. WALL TYPE 'W2' TO BE 1 HOUR RATED. WALL TYPE 'W2' 1,_ „ ISTIC LAMINATE UNTERTOP (PL1) 'n E AS SCHEDULED 21" METAL STUDS AT 16" O.C. PIPED SECURED TO FLOOR. ONE LAYER J" TYPE "X" GYPSUM WALL BOARD ON EACH SIDE. DRYWALL WRAP ENDS OF WALL AND INSET 6" FROM EDGE OF COUNTERTOP. EXTEND WALL TO UNDERSIDE OF COUNTERTOP. WALL TYPE 'W3' PARTY ROOM COUNTER SCALE: 3/8 " =1' -0" WALL LEGEND EXISTING WALL TO REMAIN NEW WALL (SEE WALL TYPES ON THIS SHEET) W# DOOR LEGEND DOOR AND FRAME NOT IN SCOPE OF WORK DOOR AND FRAME IN SCOPE OF WORK (SEE #� DOOR SCHEDULE). ARCHITECTURAL FLOOR PLAN KEYNOTES ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS A01 EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'X4'X3/4 ", PAINTED WITH FIRE A02 RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. COORDINATE WITH TENANT FOR EXACT LOCATION. PROVIDE AND INSTALL (5) FULL DEPTH ADJUSTABLE SHELVES A03 ACCESSIBLE FROM BOTH SIDES OF CLOSET. EXISTING RESTROOM PLUMBING FIXTURES AND GRAB BARS TO REMAIN A04 AS IS. PROVIDE AND INSTALL VERTICAL GRAB BAR. REFER TO 2/A411 FOR MOUNTING DIMENSIONS. FIELD VERIFY DEMISING WALLS EXTEND TO DECK AND ARE INSULATED. A05 IF NOT, EXTEND WALL TO DECK AND PROVIDE INSULATION TO MATCH WALL TYPE 'W2'. DEMISING WALLS ARE TO BE 1 HOUR RATED WALL. A06 EXISTING CABINETS, SINK, FAUCET AND PLUMBING LINES TO REMAIN AND BE REUSED. Ap7 REFER TO ENLARGED PLAN 1 /A111 PROVIDE BLOCKING IN WALL FOR TENANT SIGNAGE. REFER TO TENANT A08 FOR EXACT LOCATION. A09 PROVIDE BLOCKING IN WALL FOR TENANT WALL MOUNT TELEVISION. REFER TO TENANT FOR EXACT LOCATION. F---- - - - - -, ARCHITECTURAL FLOOR PLAN SCALE: 1/8"= l'-O" GENERAL FLOOR PLAN NOTES Al. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE -BID FIELD INSPECTION. A2. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF JOB CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR INDICATED. A3. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO THE ARCHITECT. A4. ALL DETAILS, MATERIALS AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY THE ARCHITECT AND FINAL APPROVAL BY THE OWNER. A5. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO THE ARCHITECT FOR APPROVAL FOR ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS OR IF THE DRAWINGS TO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. A6. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, ORDERING, FABRICATION AND DELIVERY OF MATERIALS AND EQUIPMENT. A7. PROVIDE FIRE - TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY ETC. A8. NOT USED. A9. PATCH AND REPAIR ALL GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS AND AT AREAS WHERE ELECTRICAL, DATA AND SWITCH DEVICES ARE REMOVED. PATCH WITH DRYWALL, TAPE, SPACKLL AND PREPARE FOR NEW FINISH. A10. FIRE SEAL ALL PENETRATIONS THRU RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. All. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW STUD OR FACE TO FACE OF NEW STUD UNLESS OTHERWISE NOTED. Al2. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. NOTE: PLUMBING, ELECTRICAL, MECHANICAL GENERALLY INDICATED ON THIS DRAWING IS FOR REFERENCE ONLY. REFER TO MEP DRAWINGS FOR FURTHER INFORMATION. REFER TO DESIGN BUILD CONTRACTORS DRAWINGS FOR FIRE /LIFE SAFETY AS IT PERTAINS TO MEETING ALL STATE AND LOCAL CODES AND ORDINANCES. 91 1111 HIF 11H IIH Hill 11111 IIIH HIII HIII Hi AiaaA Erma"s q`8 €( ] �4 ! 4 m u A s � �� � F +� _. _. _ t22 r_t .s, ,>� `. 3 �' I i s_$� '�g y � � m � � .�, d a Fi�•�_i'2$ia033 } } A (9KEY PLAN 4p NOT TO SCALE :.__. wd .. A CL O O W 0 0 W w z Cr)Q O�zQ Q O QD C.%) O z z wJ O =>w F__ � — zQ Q �U w =� �t- N ,o cc cc 0 0 x CZ) CID 00 O co Q0 w c0 Fit C\2 I� 0 0 0 O w � Q0 LL_ W � Q • 0­4 U E-4� z� U Q 0 L2 Stamp: .�... No. = 4041 STATE OF ' ' �&D I Issue: STATE AND CITY SUBMITTAL Date: 04/29/12 Project No.: A12320 File No.: Sheet: Al I I