HomeMy WebLinkAboutB2' -0" , 2' -0"
CEILING LINE
w
SOUND BATT
INSULATION
BASE AS SCHEDULED
2�" METAL STUDS AT 16" O.C.
ONE LAYER J" TYPE "X" GYPSUM
WALL BOARD ON EACH SIDE.
USE (MR) MOISTURE RESISTANT
WALL BOARD WITHIN 5' OF WET
FIXTURES
EXTEND WALL TO UNDERSIDE OF
FINISHED CEILING.
SOUND BATT INSULATION INSIDE
WALL AND 2' EITHER SIDE
ABOVE CEILING.
MATCH THICKNESS OF EXISTING
STUDS AT DOOR INFILLS.
NOTE: NEW INTERIOR WALLS TO
BE WALL TYPE 'W1'
WALL TYPE 'W1'
WALL TYPES
SCALE: 11/4"=V-0"
METAL DECK
CEILING LINE
SOUND BATT
INSULATION
BASE AS SCHEDULED
3J" METAL STUDS AT 16" O.C.
ONE LAYER �" TYPE "X" GYPSUM
WALL BOARD ON EACH SIDE.
USE (MR) MOISTURE RESISTANT
WALL BOARD WITHIN 5' OF WET
FIXTURES
EXTEND WALL TO UNDERSIDE OF
METAL DECK.
SOUND BATT INSULATION INSIDE
WALL TO DECK.
MATCH THICKNESS OF EXISTING
STUDS AT DOOR INFILLS.
NOTE: DEMISING WALLS. WALL
TYPE 'W2' TO BE 1 HOUR
RATED.
WALL TYPE 'W2'
1,_ „
ISTIC LAMINATE
UNTERTOP (PL1)
'n E AS SCHEDULED
21" METAL STUDS AT 16" O.C.
PIPED SECURED TO FLOOR.
ONE LAYER J" TYPE "X" GYPSUM
WALL BOARD ON EACH SIDE.
DRYWALL WRAP ENDS OF WALL
AND INSET 6" FROM EDGE OF
COUNTERTOP.
EXTEND WALL TO UNDERSIDE OF
COUNTERTOP.
WALL TYPE 'W3'
PARTY ROOM COUNTER
SCALE: 3/8 " =1' -0"
WALL LEGEND
EXISTING WALL TO REMAIN
NEW WALL (SEE WALL TYPES ON THIS SHEET)
W#
DOOR LEGEND
DOOR AND FRAME NOT IN SCOPE OF WORK
DOOR AND FRAME IN SCOPE OF WORK (SEE
#� DOOR SCHEDULE).
ARCHITECTURAL FLOOR PLAN KEYNOTES
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS
A01 EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE
WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'X4'X3/4 ", PAINTED WITH FIRE
A02 RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. COORDINATE WITH
TENANT FOR EXACT LOCATION.
PROVIDE AND INSTALL (5) FULL DEPTH ADJUSTABLE SHELVES
A03 ACCESSIBLE FROM BOTH SIDES OF CLOSET.
EXISTING RESTROOM PLUMBING FIXTURES AND GRAB BARS TO REMAIN
A04 AS IS. PROVIDE AND INSTALL VERTICAL GRAB BAR. REFER TO 2/A411
FOR MOUNTING DIMENSIONS.
FIELD VERIFY DEMISING WALLS EXTEND TO DECK AND ARE INSULATED.
A05 IF NOT, EXTEND WALL TO DECK AND PROVIDE INSULATION TO MATCH
WALL TYPE 'W2'. DEMISING WALLS ARE TO BE 1 HOUR RATED WALL.
A06 EXISTING CABINETS, SINK, FAUCET AND PLUMBING LINES TO REMAIN
AND BE REUSED.
Ap7 REFER TO ENLARGED PLAN 1 /A111
PROVIDE BLOCKING IN WALL FOR TENANT SIGNAGE. REFER TO TENANT
A08 FOR EXACT LOCATION.
A09 PROVIDE BLOCKING IN WALL FOR TENANT WALL MOUNT TELEVISION.
REFER TO TENANT FOR EXACT LOCATION.
F---- - - - - -,
ARCHITECTURAL FLOOR PLAN
SCALE: 1/8"= l'-O"
GENERAL FLOOR PLAN NOTES
Al. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS
WITH ALL OTHER TRADES. FIELD WORK ORDERS WILL NOT BE APPROVED
FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED
FOR BY THE BIDDER DURING PRE -BID FIELD INSPECTION.
A2. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE
GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF JOB
CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR INDICATED.
A3. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT
ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO THE ARCHITECT.
A4. ALL DETAILS, MATERIALS AND INSTALLATIONS ARE SUBJECT TO FIRST
APPROVAL BY THE ARCHITECT AND FINAL APPROVAL BY THE OWNER.
A5. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO THE
ARCHITECT FOR APPROVAL FOR ALL MATERIALS OR ITEMS WHERE THE
CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS
OR IF THE DRAWINGS TO NOT INDICATE A SPECIFIC MANUFACTURER OR
MODEL NUMBER.
A6. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO
ALLOW SUFFICIENT TIME FOR CHECKING, ORDERING, FABRICATION AND
DELIVERY OF MATERIALS AND EQUIPMENT.
A7. PROVIDE FIRE - TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG
ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY ETC.
A8. NOT USED.
A9. PATCH AND REPAIR ALL GYPSUM WALLBOARD WHERE DEMOLITION HAS
OCCURRED AT REMAINING WALLS AND AT AREAS WHERE ELECTRICAL, DATA
AND SWITCH DEVICES ARE REMOVED. PATCH WITH DRYWALL, TAPE, SPACKLL
AND PREPARE FOR NEW FINISH.
A10. FIRE SEAL ALL PENETRATIONS THRU RATED WALLS, FLOORS, AND
CEILINGS WITH APPROVED FIRE RATED CAULK AS DIRECTED BY LOCAL
JURISDICTIONS.
All. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE
OF NEW STUD OR FACE TO FACE OF NEW STUD UNLESS OTHERWISE NOTED.
Al2. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR
FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL BE SCRIBED TO FIT
TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED.
NOTE: PLUMBING, ELECTRICAL, MECHANICAL GENERALLY INDICATED ON THIS
DRAWING IS FOR REFERENCE ONLY. REFER TO MEP DRAWINGS FOR
FURTHER INFORMATION. REFER TO DESIGN BUILD CONTRACTORS DRAWINGS
FOR FIRE /LIFE SAFETY AS IT PERTAINS TO MEETING ALL STATE AND LOCAL
CODES AND ORDINANCES.
91 1111 HIF 11H IIH Hill 11111 IIIH HIII HIII Hi
AiaaA Erma"s q`8 €( ] �4
! 4 m u A s
� �� � F +�
_. _. _
t22 r_t
.s,
,>� `. 3 �' I i s_$� '�g y � � m � � .�, d a Fi�•�_i'2$ia033
}
}
A
(9KEY PLAN 4p
NOT TO SCALE
:.__.
wd
..
A
CL
O
O
W
0
0
W
w
z Cr)Q
O�zQ
Q O QD
C.%) O z
z wJ
O =>w
F__
�
— zQ
Q �U
w =�
�t-
N
,o
cc
cc
0
0
x
CZ)
CID
00
O co Q0
w c0
Fit C\2
I�
0
0
0
O w �
Q0
LL_
W �
Q
•
04
U
E-4�
z�
U
Q
0
L2
Stamp:
.�...
No.
= 4041
STATE OF '
' �&D I
Issue:
STATE AND CITY
SUBMITTAL
Date: 04/29/12
Project No.: A12320
File No.:
Sheet:
Al I I