Loading...
HomeMy WebLinkAboutPacket - Development Plan I I I I I I I I I I I I I I I I I I I TABLE OF CONTENTS: I. Development Plan Application II. Legal Description III. Location Map, Soils Map and Floodplain Information IV. Site Plans . Survey . Site Plan · Drainage Plan . Pavement and Curbing Details V. Landscape Plans . Landscape Plan . Planting Details VI. Lighting Photo-metrics Plan and Specifications VII. Signage Plans and Details VIII. <Building Perspective and Elevations I 'I I I I I I I I I I I I I I I I I I DEVELOPMENT PLAN APPLICA TION (Amendment) Fee: $750.00 plus $100.00 per acre ($750.00 plus $100.00 per acre) DAT-E: 5/21/04 DOCKET NO. Preliminary x Public Hearing Required x Final Received By/Date Amended or Changed Checked By Name of North Meridian Medical Pavilion Project: Project Address: Approx. 12202 N. Meridian St., Carmel, IN 46032 Legal Description: (To be typewritten on separate sheet and attached) See Attachment. Name of Applicant: Lauth Property Group Address: 9777 N. College Ave, Indianapolis, IN 46280 Contact Person: Tom Eagley Telephone: 575-3051_ Fax No. 564-3051 Name of Landowner: Regency Realty Telephone: 571-0500 Address: 8710 N. Meridian St., Indianapolis, IN 46260 Plot Size: 9.07 ac Zoning Classification: 83/86 Present Use of Property: Vacant Proposed Use of Property: Medical, Office and related clinical facilities I I I I I I I I I I I I I I I I I I I NOTE: This application must be filed in duplicate and accompanied by: a) Two (2) copies of the development plan which the applicant will be . responsible for distribution among TAC members; b) All necessary supporting materials. The u~dersigned agrees that any construction, reconstruction, enlargement, relocation or alteration of structures, or any change in the use of land or structures requested by this application will comply with and conform to all applicable laws of the State of Indiana and the zoning ordinance of Carmel, Indiana, adopted under the authority of Acts of 1979, Public Law 178, Sec. 1, et seq., General Assembly of the State of Indiana, and all Acts amendatory thereto. 1~~4 k,' /~~ ;;;~ Dwnel' ~. / J \', Signed: (Typed) / i "\ t~:~ .T(j~) J"'~ v!Jc:rJ (Typed) STATE OF INDIANA County of ~1 c;;?~ ( Before me the undersigned, a Notary Public for7J1t:(/~ (coun..!)' of resi ce) County, State of Indiana, personally appeared~.~~~;'-'n~:?~ ~ (name of person) ~/ and acknowledged the execution of the foregoing instrument this ~ c:; day of 7?;1d?~~ , 20 ~- /J / ~/~ ' r ....>P~.4 ..- SS: (Notary Public Signature) '--z; ~. fA T /( / ~ /// <2'~,-oc? ~-L5 (Printed or Typed) My Commission Expires: f;~?) ~- '-3 / / z: \shared\forms\PC applications\devplan.app Rev. January 5, 2004 I I I I 1\ I. I I I I I I I I I I I I I RECORD LAND DESCRIPTION PARCEL NO.1 Part of the East Half of the Northwest Quarter of Section 35, Township 18 North, Range 3 East in Hamilton County, Indiana, described as follows: Commencing at the Southeast corner of the Northwest Quarter ot Section 35, Township 18 North, Range 3 East; thence South 88 degrees 51 minutes 53 seconds West (assumed bearing) on the South line of said Northwest Quarter 1328.33 feet to the Southwest corner of the East Half of said Northwest Quarter, said corner being collinear and equidistant between said Southeast corner and the Southwest corner of said Northwest Quarter; thence North 00 degrees 0'1 minutes 21 seconds West 987.00 feet to the place of beginning of the real estate herein described; thence North 88 degrees 51 minutes 53 seconds East parallel with said South line 402.50 feet to the Westerly right-at-way line of Local Service Road-#2 as per I.S.H.C. plans for PrajectNo.St~F-221 (9); thence North 00 degrees 01 minutes 08 seconds East on said right-of-way line and Westerly right-of-way line of Local Service Road #3, 654.02 feet; thence South 88 degrees 51 minutes 53 seconds West parallel with said South line 402.97 feet to the West line of East Half; thence South 00 degrees 01 minutes 21 seconds East on said West line 654.00 feet to the place of beginning, containing 6.046 acres, more or less. PARCEL NO.2 Part of the East Half ot the Northwest Quarter of Section 35, Township 18 North, Range 3 East in Hamilton County, Indiana, described as follows: Commencing at the Southeast corrier at the East Half of the Northwest Quarter of Section 35, Township 18 North, Range 3 East; thence North 00 degrees 02 minutes 42 seconds West (assumed bearing) on the East line of said Northwest Quarter 1968.00 feet; thence South 88 degrees 51 minutes 53 seconds West parallel with the South line of said Northwest Quarter 916.93 feet Deed (924,34 feet measured) to the Westerly right of way line of local service road # 3 as per I.S.H.C. plans for Project No. STF-222 (9) dated 1973 for relocation of U. S. Highway #31 and the place of beginning of the real estate herein described; thence South 88 degrees 51 minutes 53 seconds West parallel with said South line 403.21 feet to the West line of the East Half of said Northwest Quarter; thence South 00 degrees 01 minutes 21 seconds East on said West line 327.00 feet; thence North 88 degrees 51 minutes 53 seconds East parallel with said South line 402.97 feet to the Westerly right of way line of the aforesaid service road; thence North 00 degrees 01 minutes 08 seconds East on said right of way line 327.01 teet to the place of beginning, containing 3.025 acres, more or less. *The above measured-distances in Parcel #2 are taken from the record land description for that parcel and do not represent the measured distances obtained during this survey. I. SITE LOCATION MAP I I I I Roads I Interstate US Highway State Road Major Roads Minor Roads Subdivision Roads New Subdivision Roads Private Road or Drive D Parcel Boundary - I I I I Zoning [::'.'1 ... E]';::J Carmel Clay Zoning r.:::::J B-1 _B-2 . B-3 r.:r,] B-5 .B-6 r.::::,:J B-7 .B-8 ~::r;:J C-1 _C-2 C:::J 1-1 _M-3 [::rrJ OM/M rI:::':J OM/MF F?! OM/MM I I I I I I I I I SCALE 1 : 10,985 ....-- 500 0 500 FEET http://216_37_62_70/map/carmeLmwf N 1,000 I, 1,500 A Thursday, May 20, 20044:47 PM I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I w z 0 N I w I z 0 N I I- ill ill LL 0' ~I ~ ~ en ~ z < c: ~ 11. u11 f8 f8 ~ I- < 0 ~ 'B g ~ z Z Q ~ ffif ~ 0 ~ ~ ~ i ~ E-t z 0 <( u ~ Il. Z ~ C) a: 0 CD 2 Z ~ "" 0 -< ~ La.. ,~ 0 c:::::t -~ 'Z U Q LL ~ co ~ -< 2S c:::::t o=> ~ -C'o( Il. -rl ~8 ~ t-f <( Q Q .... ~ ~ ~ ~ a I0I.l Z ~ :::z III ~ ~ ~ ~ :.:r= ~ UJ 8 8.~ ~ t-f "- ~ :IE ~ c.:J Q a: a.. ...... Co:>> ' :z: ~ = en a5 C:a '0 9 La.. .;..", cc :z c::> Ei :z: o o LO ICL c:c == ~ ~ cr: L&.I c.,:) :z: c:c 0:: ::) V) :!;!!: ai-g -= u..~ W -.J <( U V) w ~ 2 X o a: a... Q... <3: .1 ~lj zw~ ~~~ ,g~ 5 "'=>- ~~.i .s:Jz~ t: => 'ii !~: a:Uc: !~.i t!c ~~o ~O~ ~~~ ~f~i llll l- V) g~ 00 a: w ~ o GH 38'1 INOH~ -I - I ~I I >< w 0 0 Z 0 0 N ~ t o a:. , <( -1 .J <t: 2 08 lllV'-J 8NI8dS >< >< u.a w Z Z a:: La.. L&.I co a:a C) ::EN =c::J :z~ Ln -D.. = cc co ::e..... .. ~ L&.I = !;ic::::J =.("00,1 ....cn >- ~~ L&.I c:c La.. = La.. D: L&.I I:D ~ ~ 5 be < ;:: i c:: ~ ~ ~ = ~ II) a ~ > Q) 0 IDO~ .cCrn ...(/)+-'~E -Q)C:JQ) .0)0(/)'1-: Q.CQ)CO !U rn +-' - (/) E-5~-gE -0 ." 0 ~. o ... "'- o~~~ q:: ~. 0 ro -g~:5ro o 15 c:+:; Q) ~c~~o ..... (/) 0- +-' ~Q)ID:5(/) ~ .g lL8 g- ~Q.~ro~ .8 E ~ .~ -g !U(/)!UroO _~~~EU: 'to- Q) J2 <( OQ)IDC~ cc.o:;::w .2 :.J !I) 0 LL [8~~~ !U I- .>-. Q. .::L. o~Ewg I Q).c i): LL .c 10 0 o ~~ ~ ~ ;.~~: E 0-01:0-0 !EQ)Q)LLo ~"'-5~.g !U cOE .!!! ~:B ~ .!!! ro Q) 8' .c "- ... ..... I- o+- a. CiTY OF. CARMEL - HAMJL TON COUNTY I I CHALLENGER I . I Contoured lens I I Flat lens . I I I I I I I I I I I CHV Type 5 - Vertical I -- I THE CHALLENGER@ SERIES The Challenger offers total optical flexibility in a sleek, aerodynamically designed fixture. The one-piece, die-cast aluminum luminaire complements the architectural integrity of virtually any site. Standard design features include IP65 rating which completely seals the Challenger housing from penetration of external contaminants. Designed around a standard 400 Watt and a 1000 Watt reduced envelope lamp size, the Challenger gives you a choice of either horizontal or vertical lamp orientation, plus a variety of lamp types and reflectors to best meet your application. The compact, low profile shape creates lower EPAs, which may allow use of lighter gauge poles. The Challenger is easy to install and to maintain. SPECIFICATIONS HOUSING One-piece, die-cast aluminum in a multi-radiused, rectangular shape with mounting arm cast in as an integral part of the housing. All hardware is stainless steel or electro-zinc plated steel. DOOR FRAME The Challenger's one-piece, die-cast aluminum door frame secures to the housing with two internal hinges. Two stainless steel captive door fasteners allow easy access. Door frame may then be removed from housing without tools. A one-piece extruded silicone gasket seals the door frame against the housing. LENS/GASKET The Challenger is available with a contoured clear tempered glass lens for vertical lamp optics. A tempered flat clear glass lens or contoured clear tempered glass lens is offered for horizontal lamp optics. A one-piece extruded silicone gasket seals the lens to the die-cast aluminum door frame. SOCKETS Porcelain mogul-base sockets. All sockets are factory prewired with a disconnect plug for the ballast. All sockets are pulse-rated. LIGHT SOURCES Pulse-Start Metal Halide, Super Metal Halide, Metal Halide, Metal Halide Reduced Envelope, or High Pressure Sodium. Clear lamp is supplied as standard. BALLAST High-power factor ballast with removable/hinged ballast tray. Metal Halide, Super Metal Halide, and High Pressure Sodium fixtures feature a CW A type ballast. All ballasts are designed for -200 F operation. Optional Quick Connect package includes 1500 C supply wiring plus modular plugs for easy ballast wiring. ARM/BRACKETS The Challenger's integral cast mounting arm is flat for square pole applications. The fixture may also be mounted to round pOles using the round pole adaptor accessory (RPPC), which must be ordered seperately. An extruded 611 arm extension is required for 0900, Q900, T900 and TN 1200 fixture configurations. A locking nut secures two through bolts and a reinforcing plate to the pole, stabilizing it for easy fixture mounting. IP65 REFLECTORS/DISTRIBUTION PATTERNS. The Challenger is available with a wide variety of reflectors. Vertical Burn systems include: Type II (2), Type III (3), Type V (5), Automotive Forward Throw (FA), and Perimeter Forward Throw (FP). Horizontal Burn systems include: Type III (3), Type V (5) and Forward Throw (FT). All reflectors are field-rotatable, enabling generous flexibility in distribution patterns, without fixture movement. Photometric data is tested in accordance with IESNA guidelines. FINISHES Each fixture is finished with LSI's OuraGrip@ polyester powder coat finishing process. The OuraGrip finish withstands extreme weather changes without cracking or peeling, and is guaranteed for five full years. Standard colors include bronze, black, platinum plus, buff, white and green. POLES Refer to Poles/Brackets section of catalog for pole information. c@us LISTED listed for wet locations. PHOTOMETRICS For detailed photometric data, please visit our web site at www.lsi-industries.com CHV Type 3 - Vertical CHV Type FA - Vertical CHH Type FT - Horizontal CHH Type 3 - Horizontal J;! Lighting Systems 1M 10000 Alliance Road. Cincinnati, Ohio 45242. (513)793-3200 FAX (513)984-1335 . www.lsi-industries.com I I I I I I I I I I I I I I I I I I I #! Lighting SystemsTM __ DIMENSIONS CHALLENGER ~ 2811 LUMINAIRE EPA CHART Extension Arm Required J. + Includes bracket. - .. L "- Single D1800 D900 T900 TN1200 0900 Challenger F CT F CT F CT F CT F CT F CT Cast arm I 1.8 2.0 I 3.7 4.1 - - I - - I - - I - - Extruded bracket I 2.2 2.3 I 4.3 4.6 3.9 4.3 I 6.1 6.5 I 6.3 6.9 I 7.7 8.6 INote: F - Flat Glass CT - Contoured LUMINAIRE ORDERING INFORMATION Select a ro riate choice from each column to formulate order code. Refer to exam Ie below. Luminaire Distribution Lamp Light Source Lens Line Voltage3 Luminaire Options Prefix Wattage Finish Vertical Burn 2-Type II 250 PSMV - Pulse-Start Metal Halide CT - Contou red 480V BRZ - Bronze PCR - Photoelectric Control CHV 3-Type III 320 250,320, 400, 750 1000 Watt Clear MT - Multi Tap4 BLK - Black Receptacle FP- Forward Throw 400 SMV - Super Metal Halide Tempered TT - Tri- TapS PLP- Platinum LL - Less Lamp Perimeter 750 400 Watt Glass Plus QC - Quick Connect Package FA-Automotive 1000 MH - Metal Halide BUF - Buff GR - Ground Relamping6 Perimeter 250,400 Watt WHT - White 5 - Type V MHR - Metal Halide Reduced Envelope GRN - Green 1 000 Watt HPS - High Pressure Sodium 250,400, 7501 Watt Horizontal Burn 3-Type III 250 SMH - Super Metal Halide F - Flat Clear CHH FT- Forward Throw 400 250,400 Watt Tempered 5 - Type V 750 MH - Metal Halide Glass 1000 250,400 Watt CT - Contoured MHR - Metal Halide Reduced Envelope Clear 1 000 Watt Temp~red HPS - High Pressure Sodium Glass 250, 400, 7501 Watt EXAMPLE OF A TYPICAL ORDER CHV 1- When ordering 750 Watt High Pressure Sodium, voltage must be specified. 2- Use to match vertical appearance. 3- For international voltages, consult factory. 4- MT - Multi Tap is shipped standard unless otherwise specified. Multi Tap consists of 120V, 208V, 240V, and 277V. Multi Tap is pre-wired for highest voltage. Alternate voltages will require field re-wiring. 5- Tri- Tap is shipped standard for C-UL applications. Tri- Tap consists of 120V, 277V, and 347V. Tri-Tap is pre-wired for highest voltage. Alternate voltages will require field re-wiring. 6- Ground relamping option available on vertical lamps only. Maximum tool length 15 ft. (Accessories are field installed) Description CHH/CHV 2 HSS - External House Side Shield CHH/CHV 3 HSS - External House Side Shield CHH/CHV FA HSS - External House Side Shield CHH/CHV FP HSS - External House Side Shield RPPC - Round Pole Plate BKS-BO-WM- *-CLR Wall Mount Plate BKA-BO-EC-6-CLR Extension Arm Required for multiple fixture mounting @ all 900 & 1200 angles BKU-BO-S-19-CLR Upsweep Bracket Ground Lamp Changer 132678A (250, 320 Watt) +Black Only ACCESSORY ORDERING INFORMATION Description Order Number PC120V - Photocell 122514 PC208V - Photocell 122515 PC240V - Photocell 122516 PC277V - Photocell 122517 PC480V - Photocell 122518 FK120V - Single Fusing FK120V FK277V - Single Fusing FK277V DFK208, 240V - Double Fusing DFK208, 240V DFK480V - Double Fusing DFK480V FK347V - Single Fusing FK347V Order Number 143586BLK+ 143587BLK+ 143587BLK+ 143587BLK+ 141940CLR 123111CLR 142862CLR 144191 CLR 146018A (400 std, 1000 Watt Reduced) I TEEl S UARE POLES - FOR USE WITH CHALLENGER & PATRIOT lUMINAIRES POLE SHAFT - Pole shaft is electro-welded ASTM-A500 Grade C steel tubing with a minimum yield strength of 50,000 psi. On Tenon Mount steel poles, tenon is 2-3/8" 0.0. high- strength pipe. Tenon is 4-3/4" in length. Straight poles are 4", 5", and 6" square. HAND-HOLE - Standard hand-hole location is 12" above pole base. Hand-hole size is 2" x 4". Poles 22' and above have a 3" x 6" reinforced hand-hole. BASE - Pole base is ASTM-A36 hot-rolled steel plate with a minimum yield strength of 36,000 psi. Two-piece square base cover is optional. ANCHOR BOLTS - Poles are furnished with anchor bolts featuring zinc-plated double nuts and washers. Galvanized anchor bolts are optional. Anchor bolts conform to ASTM-A36 with a minimum yield strength of 36,000 psi. GROUND LUG - Ground lug is standard. DUPLEX RECEPTACLE - Weatherproof duplex receptacle is optional. GROUND FAULT CIRCUIT INTERRUPTER - Ground fault circuit interrupter is optional. FINISHES - Each pole is finished with LSl's OuraGrip@ baked-on polyester-powder finishing process to give the pole an exceptionally attractive appearance. The process electrostatically applies and thermally fuses a polyester powder to the pole. This unique protection process provides an extremely smooth and uniform finish which withstands extreme weather changes without cracking or peeling. OuraGrip finish features a two-year limited warranty. Standard finish colors available for poles are bronze, black, platinum plus, buff, white, green, and graphite. Optional OuraGrip@ Plus features added protection with a 3.0 to 5.0 mil thickness of polyester-powder finish plus an inner coating. This specially developed inner coating is a thermal plastic hydrocarbon resin applied to the inside of the pole to seal and protect against atmospheric and corrosive matter. OuraGrip Plus finish features a five-year limited warranty. DETERMINING THE LUMINAIRE/POLE COMBINATION FOR YOUR APPLICATION: · Select luminaire from Luminaire Ordering Information. · Select bracket configuration. · Refer to Luminaire EPA Chart to determine EPA value. · Select Height of pole. · Select MPH to match the wind speed in the application area. · Confirm the pole EPA that is equal to or exceeds the luminaire/bracket EPA as was previously determined. -- Height EPA~ Outside Material Bolt 70 MPH 80 MPH 90 MPH 100 MPH Dimensions Circle 14' 23.3 16.7 12.2 9.0 4" SllG B 16' 18.6 13.1 9.3 6.5 4" SllG B 16' 34.6 25.0 18.5 13.8 5" SllG C 18' 14.4 9.7 6.5 4.2 4" SllG B 18' 27.9 19.7 14.1 10.1 5" SllG C 20' 11.0 7.0 4.2 2.2 4" SllG B 20' 18.7 12.8 8.8 5.9 4" S07G B 20' 22.5 15.4 10.5 7.0 5" SllG C 20' 35.5 25.4 18.4 13.4 5" S07G 0 22' 10.4 6.3 3.4 1.4 4" S11G B 22' 18.7 12.6 8.4 5.4 4" S07G B 22' 20.8 13.8 8.9 5.5 5" S11G C 22' 34.0 23.9 17.0 12.0 5" S07G 0 24' 7.7 4.0 1.5 - 4" SllG B 24' 15.1 9.7 6.0 3.3 4" S07G B 24' 16.7 10.5 6.2 3.1 5" S11G C 24' 22.5 14.9 9.7 5.9 5" SllH* 0 24' 28.6 19.6 13.4 8.9 5" S07G 0 24' 46.2 32.6 23.2 16.6 6" S07G J 26' 5.3 2.1 - - 4" SllG B 26' 12.0 7.2 3.9 1.5 4" S07G B 26' 132 7.6 3.8 1.0 5" SllG C 26' 24.0 15.8 10.3 6.3 5" S07G 0 26' 39.6 27.3 18.9 12.9 6" S07G J 28' 19.9 12.5 7.5 3.9 5" S07G 0 28' 33.9 22.7 15.1 9.6 6" S07G J 30' 16.3 9.6 5.0 1.7 5" S07G 0 30' 28.8 18.6 11.6 6.6 6" S07G J 35' 18.3 10.0 4.3 - 6" S07G J 39' 11.5 4.3 - - 6" S07G J ~ Refer to EPA data on next page for complete EPA information. If lumina ire weight exceeds 250 Ibs., consult factory * "H" denotes high yield steel (70,000 psi). Project Name Catalog # ~IMENsrONS. '". \~i, '.,"' . '. I,', - SQN- 2-3/8" 0.0. x 4-3/4" Tenon JI 14'-39' Hand-hole Optional Base Cover (4) Anchor Bolts Foundation By Other SQBO - Bolt.On Mount 2-Bolt Pattern JJ SQP- Square Pole Top [@J] SQI- No Mounting Holes )J SF - Single Flood Pole Preparation ~ Side "c" I DRI LUNG LOCATIONS ' - Sides Hand-hole Sin Ie 0180' 090' X T90' X TN120'* X 90' X Sin Ie FBO X Double FBO X X *Other two locations will be 120' to the left and ri ht of Side A. Note: Consult factory for custom variations. Standard SF and OF pole preparations are located 3/4 of the height of the pole from the base, unless otherwise specified. Side "0" - I Side "A" (Hand.hole Side) A B X X X X X Fixture Type -Side "B" C D X X X X X I STEEL SQUARE POLES - FOR USE WITH CHAllENGER & PATRIOT lUMINAIRES I ORDERING INFORMATION Pole . I H . h Mou,ntingc P I F. . h 0 t. Series I Matena elg t Confi.uration oe InIS . " " pions> _, _, , Order Number 4" square 5" square 5" square 6" square 122559CLR @ @) 10-1/8" sq. 12" sq. 122561CLR @ ~ 122563CLR 122566PLT 122567PL T r r r 132336 11" Dia. Bolt Circle 11" Dia. Bolt Circle 11" Dia. Bolt Circle 12" Dia. Bolt Circle 172539 B C D J 172538 Slotted Slotted Slotted Bolt Circle 8" to 11" 9" to 11" 9" to 11" 12" Anchor Bolt Size 3/4" x 30" 3/4" X 30" 1" x 36" 1" x 36" Anchor Bolt Projection 3-1/4" 3-1/4" 4" 4" Base Plate Opening for Wi rewa Ent 3 - 5/8" 4-3/4" 4-5/8" 5-5/8" Base Plate Dimensions 10-1/8" s . x 3/4" thk. 10-1/8" . x 3/4" thk. Note: Base plate illustrations may change without notice. Do not use for setting anchor bolts. Consult factory for the base plate templates. I Square pole for Bolt-on mount 2-Bolt Pattern 4SQBO 5SQBO 6SQBO SllG-ll Ga. Steel 14' SllH-ll Ga. Steel 16' S07G - 07 Ga. Steel 18' 20' 22' 24' 26' 28' 30' 35' 39' I I Square Pole for Pole Top Mount 4SQP 5SQP 6SQP I Square Pole for Tenon Mount 4SQN 5SQN 6SQN Consult Pole Selection Chart on opposite page. I Square Pole (No mounting hole No pole top caps) 4SQI 5SQI Ii I EXAMPLE OF A TYPICAL ORDER 5SQBO I ACGESSORY ORDERING INfORMATION (~ccessones are field Installed) Description 4BC - 4" Square Base Cover 5BC - 5" Square Base Cover 6BC - 6" Square Base Cover ER2 - Weatherproof Duplex Receptacle GFI - Ground Fault Circuit Interrupter MHP - Mounting Hole Plugs (3 plugs) Vibration Damper - 4" Square Pole Vibration Damper - 5" Square Pole I I I I I S - Single/Parallel 01800 - Double 0900 - Double ON900 - Double T900 - Triple TN1200 - Triple Q900 - Quad QN900 - Quad PT - Pole Top Mount BRZ - Bronze BLK - Black PLP - Platinum Plus BUF - Buff WHT - White GRN - Green GPT - Graphite GA - Galvanized Anchor Bolts SF - Single Flood2 OF - Double Flood2 DGP - DuraGrip@ Plus LAB - Less Anchor Bolts ERA INFORMATION , _ ' . ,'. ' ' , ~. . _' ;.' '." I , , '. ' " P,; ,: _:,', ,~:': /." ~ ~ N - Tenon Mount (Standard tenon size is 2") Standard SF a nd OF pole preparations are located 3/4 of the height of the pole from the base, unless otherwise specified. I - For use with Internal Slip-Fitter 1 . . . 1- See Area Lighting Brackets Section. 2- See Flood Lighting Brackets BOLT CIRCLE . ", .' ,,> ',-,.: '0' '. ~', ~ .," . .', .,,:", I All LSI Lighting Systems' poles are guaranteed to meet the EPA requirements listed. LSI Lighting Systems is not responsible if a pole order has a lower EPA rating than the indicated wind-loading zone where the pole will be located. CAUTION: This guarantee does not apply if the pole/bracket/fixture combination is used to support any other items such as flags, pennants, or signs, which would add stress to the pole. LSI Lighting Systems cannot accept responsibility for harm or damage caused in these situations. I NOTE: Pole calculations include a 1.3 gust factor over steady wind velocity. Example: poles designed to withstand 80 MPH steady wind will withstand gusts to 104 MPH. EPAs are for locations 100 miles away from hurricane ocean lines. Consult LSI for other areas. Note: Hurricane ocean lines are the Atlantic and Gulf of Mexico coastal areas. For Florida applications - consult factory. I Project Name Catalog # I Fixture Type Flood Lig tin g FORM, FUNCTION, FRUGALITY At last, there is a complete outdoor lighting system designed to meet the functional, aesthetic, operational and ecooomic needs of commercial and retail rnulti-site facilities. From the convenience and savings of inter- changeable components, best-of-class optics and photometries, to the beauty of complete archiLectural integrity in wall, area and flood lighting; our line of Criterion TM lurninaires will meet your every need, A BRILLIANT SOLUTION Now alJ your lighting across the country and across fhe parking lot can have the same look. But the value of Criterion luminaires goes deeper than their sleek die-cast exteriors. From their low~profile hardware and con- cealed gaskets to their easy tool-free mainte nance, every aspect of Criterion's hOU5- ing has been designed to maximize beauty, strength, durability and econornical operation. Best of all, the inside of this IUIIlinaire is jusl as beautiful as the outside. The Criterion Series inciudes design breakthroughs that will change the way you choose and specify lighting for years to come. FLOOD LIGHTING Criterion F100dlights offer aU the flexibility of the Criterion fmllily: a consistent farnily look, housings that are scaled to wattage, tooi-less entry, and of course, the SnapDrive'M Electricai System, That's on1y the beginning of this lumina ire's flexibility. Criterion flood- lights feature a very broad range of application specific reflectors. FnHn general purpose. to facade, to spotlighting and parking lot lighting, there is a Criterion floodlight taiJored to meet your needs. Customize your floodlight with a variety of external accessories ready to mount on predrilled mounting pads and tanlper-resistant hard- ware and you have a tJexib1e floodlight indeed. I. I I SNAPDRIVETM: SIMPLICITY AT ITS BEST I At the heart of the Criterion Th' Series is the SnapDrive Electrical System, SnapDrive clips in and out of the lUI11inaire without tools. It '5 possible to make installation and mainte- nance a one-person/ one-ladder job which saves you time and nloney. Even tray electrical platforms cannot compete with SnapDrive, which is completely modular and utiHzes ultra-reliable printed circuit board technology supporting plug-in upgrades, Best of all, same wattage SnapDrive Electrical Systems are interchangeable into other luminaires across the Criterion Family. I I I I I TIME SAVING OPTIONS I Multiple options un oTle platform - Cuts inventory and IIlaintenance custs - Saves on training and labor costs - Increases productivity, speeds service - Lowers maintenance stocking Costs EZChoose TN perrnits quick configuration of Illultiple wattage and voltage selections on the same platform EZAdd'" Switched Quartz, allows a simple plug-in upgrade for instant safely lighting EZAdd Pulse Start. a plug-in that gives you pulse start lamp capability [01 more light, longer EZAdd BileveI. an energy saving option that reduces operating costs Digital diagnostic tool receptacle that pennits fast, accurate troubleshooting I I I I I I I I I 2 OPTICAL CONSTRUCTION: A REFLECTION OF SMARTER THINKING Our goals were simple. More light froril fewer lights, Better light from all lights, The right kind of light in the rIght place. Day-tn.day, year-to-year functionality and durability, Reaching those goals required sophisticated computer modeling and optimization of reflector designs. It Incant utilizing heat and impact resistant tempered glass lenses and detailed photometric analysis. Because in the end, it', all about the light, F 100 ig tin g HOUSING Die~cast aluminum housing for strength, beauty and low maintenance Scaled family styling look for consistent site enhancing look . Concealed continuous gasket seals against harmful dust, dirt, moisture and insects (IP65 rating) Tool~less entry for easy, economical maintenance . Tamper-resistanl option helps prevent unauthorized entry for security and safely Activated charcoal breath-way for clean vent iIation and long term maintained foot candle levels Predrilled integral mounting surfaces fOJ" quick installation of accessories Low~profile hinges & latches for a clean look . Choice of a palette of standard colors, 188 RAL colors, or your own custorn r:olor in fade- and abrasion-resistant powder and liquid paints SlipfHter with inj{~graIJy sealed wiring box conceals and protects wiring, saves Inain! e- nance costs and maintains a clean look OPTICS Reflector section optimized for typical applications.-faciIitates lun1inaire-to- application rnatching Asymnletrical reflectors arc computer optimized for MH lamps to maximize efficiency Rugged hydro~formed ret1ector for consistent. repeatable perforn1ance Alglas@ coating seals ref-1ectors 1'1'001 contaminants for superior long tern1 perfonnance IOOw to IOOOw MIL PMH and HPS lamp operation (Consult ballast selection table for availability.) Asymmetric hydroformed reflectors for vertical and horizontal surfaces NClna-type 11ght distributions for general purpose flood lighting Designed for C0l11pact lan1ps miniInizing EPA and pole costs ACCESSORY OPTIONS EZAdd'" Switched quartz Single & dual fusing EZAdd button PE Silevel swit ching (HPS) Matched Cross Arm Mounting Slruclun-'s Eull Line of visors and shields Matched line of poles for the ut most simplified ol'dering I I I I I I I I I I I I I I I I I I I Specifications 175 Watt ~ It Figure 1 400 Watt ~ 11 ... i~:==rrP Figure 2 1000 Watt Figure 3 I~ II /1 -D)J 10.9' 216rnm 66" lG7rnrn f 16.1' I ~'1CJl1lm G_I' 1'71mrn 18' i ISC)n)!ll I t- 9S' 241!JITI lb_1 . {,I=J" ;1 'U 8S 21/ff!rn 23.7' 602111111 ,.--.- {f Ii \;\1 1- tH " " i\ Ji Ii . .. --/1 .~._------ "11.9 10lmm 3Dj 757rnrn -------------- (r ~1l\ \\1~--1 ~D ~ 15.1" if\<1 mill 4 7.2 183mrr I.... · I ~l ,.1 ____.1 129mm 88 223mm :<f----__ 0- t ~_1' ,~ 129mm 10.2 t',J8nun ""I~ [~ . n 1'J6rnrn . I I Specifications 6 I BALLAST SELECTION TABLE I Small (Fig. 1) 100 HPS B17 __~EO" "H_ H H H 11._ 150 HPS B17 MED H H H H H 100 PMH B017 MED H II H H H 150 PMH B017 MED H H H H H 115 MH B017 MED A A A A A A Medium (Fig. 2) 250 HPS ED18 MaG A A A A A A 400 HPS ED18 MaG A A A A A A -- 250 PMH E028 MaG A A A A A A --- 400 PMH E028 MaG A A A A A A 250 Mil ED28 MaG A A A A A A 400 MH ED28 MaG A A A A A A large (Fig. 3) 1000 MH Bm MaG A A A A A A I I I I CUSTOM CONFIGURATION TABLE Consult Ballast and Photometric Selection Tables I CFSX " Small 10 100 IS) S " HPS 0" multivolt1) H" HPflAG 1 noPEreceptac!e CFMX " Medium 15 150 ISi M" metal halide 1. 120 A - AUIOREG 2 wilhPEreceptac!e CFLX -large 17 175 ISi p = pulse start metal 2- 208 3 - buttonPE' 25 250 1M) halide 3" 240 40 400 1M) 4- 277 01 liJX1 (L) 5 - 480 W = wide flood SlandardColors V = vertlcai DKBI - darkbrome slJff~rf tlood BlCK = black M - medium flood WHTE = Wllitc N -'- narrow tlond Special Colors 4 -'- spot Insertfourd~itcojor 3 -'- nar!()WSrm! code from RAL color chart - 1]8" slipfitt8f !imeDetay Switched Ouartl Cusing2! I I F XXX I NOTES: Unless otherwise requested, all luminaires are supplied with lamp (S)~ Small! (M)~ Medium! (l)~ Large 'iFactolY Set To 2!1V (""Not available with Multi-Voll @LlSTED I SUGGESTED CONFIGURATION Typical configurations are provided below for common applications to simplify your choice I 400 watt 1000 watt CFMX 40 M CFlX 01 M A A M 0 A V IJKHI CfMX 40 M 0 A CII X 01 M 0 A W OKBZ K W DKBZ K I I NOTICE: A!I data contained herein subject to change vvithout notice. Palent Pending. THE GE FIVE YEAR FIXTURE FAILURE WAR.RANTY I The GE FivecYear Fixture Failure Warranty is a limited warranty which guarantees to you, the Purchaser for resale or use in business, that the factory installed electrical system (consisting of a core and coil ballast ignitor~ capacitor, sacker, terminal board, photoelectric receptacle and wiring) inside GE HID lighting fixtures wi I! be free of defects in rnaterial and workmanship for five (5) years from the date of manufacture, or five (5) years from the dale the fixtures are shipped from the GE factory, vvhichever period you can substantiate. (Products bear a date code from which date of manufacture can be determined.) It" any GE HID fixture fails to meet this warranty, GE will ship either a repaired or replacement part F.O.B. its factory. GE makes no war- ranty to those defined as consumers in the Magnuson Moss Federal Trade Commission Improvement Act For a copy of the complete warranty, contact GE Lighting Systems, Inc., Hendersonviffe, NC 28793-4506 I I