Loading...
HomeMy WebLinkAboutE05-0 - FIRST FLOOR MECHANICAL POWER PLAN - V5 - 343867 - 120717.pdfUP UP J J T J T T T T T T J T T T T DD C1 - 1 EF - 3 A1 - 4 0 , 4 2 EC H - 5 EL C T O P R O V I D E 2 P , 3 0 A N F D I S C . MO U N T E D I N C E I L I N G W I T H 2 # 1 0 , 1" C . F O R E C H - 1 EL C T O P R O V I D E 2 P , 3 0 A N F DI S C . M O U N T E D I N C E I L I N G WI T H 2 # 1 0 , 1 " C . F O R E C H - 3 EL C T O P R O V I D E 2 P , 3 0 A N F DI S C . M O U N T E D I N C E I L I N G WI T H 2 # 1 0 , 1 " C . F O R E C H - 2 A1 - 3 6 , 3 8 EC H - 4 C1 - 1 EF - 1 C1 - 1 EF - 2 2 1 1 MD P - 2 0 , 2 2 , 2 4 CU - 2 MD P - 1 4 , 1 6 , 1 8 CU - 1 32 , 3 4 A1 28 , 3 0 A1 24 , 2 6 A1 LO B B Y 10 2 CU S T O M E R E X P . 10 9 CU S T O M E R E X P . 10 8 CU S T O M E R E X P . 10 7 VE S T I B U L E 10 1 CU S T O M E R E X P . 10 3 ST A I R 10 0 A CU S T O M E R E X P . 10 4 CU S T O M E R E X P . 10 5 CU S T O M E R E X P . 10 6 CS R 11 8 EL E C T R I C A L 12 2 WO R K A R E A 11 9 WO R K R O O M 11 7 CA S H V A U L T 11 5 S. D . V A U L T 11 6 S. D . V A U L T LO B B Y 11 2 CO R R I D O R 12 1 ME N S 11 4 WO M E N S 11 3 JA N I T O R 11 1 ST A I R 10 0 B FO Y E R 11 0 EL E V A T O R LO B B Y 12 0 19 B1 15 B1 ZD - 2 ZD - 1 17 B1 ZD - 3 ZD - 4 ZD - 5 ZD - 6 ZD - 7 ZD - 8 AH U - 1 21 B1 ZD - 1 1 ZD - 1 0 ZD - 9 AH U - 1 AH U - 2 PANEL A1 PANEL B1 PANEL C1 PANEL MDP BD - 1 ms consultants, inc.engineers, architects, planners 2221 Schrock Road Columbus, Ohio 43229 phone (614) 898-7100 fax (614) 898-7570 SHEETSHEET TITLESCALEISSUE DATEDRAWN BY CHECKED BY APPROVED BY BANKING CENTER FOR:PROJECT NO.:REVISIONBID SET 1/4" = 1'-0" 7/17/2012 4:23:30 PM 205 EAST CARMEL DRIVE FIRST FLOOR MECHANICAL POWER PLAN E05.0 62-40188-21DLR06/14/12JJC/MRM CARMEL, INDIANA 46032 NPAL - CARMEL DRIVE SC A L E = 1 / 4 " = 1 ' - 0 " E0 5 . 0 FI R S T F L O O R M E C H A N I C A L P O W E R P L A N 1 MECHANICAL POWER KEYED NOTES:= KEYED NOTE 1 E X H A U S T F A N F U R N I S H E D B Y H V A C C O N T R A C T O R A N D I N S T A LLED BY ELC. ELC. TO CONNECT INTO LIGHTS AND SWITCH WITH LIGHTS IN RESTROOM. 2 E X H A U S T F A N F U R N I S H E D B Y H V A C C O N T R A C T O R A N D I N S T A LLED BY ELC. ELC. TO CONNECT INTO LIGHTS BUT SWITCH SEPERATE FROM LIGHTS. 3 E X H A U S T F A N F U R N I S H E D B Y H V A C C O N T R A C T O R A N D I N S T A LLED BY ELC. ELC. TO CONNECT INTO HOT SIDE OF LIGHTS AND CONTROLLED BY T-STAT FURNISHED BY HVAC CONTRACTOR. NO R T H #DATEDESCRIPTION 206/04/12OWNER COMMENTS