Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A
A ]1 W Wo �SII��]P �'ACI]LI'�Y PEl\TOVAT�OI�T ice LOCATED AT: 10540 JESSUP BOULEVARD, INDIANAPOLIS, ARCHITECT INDIANA 46280 LOCKWOOD DESIGN ASSOCIATES, LLC GENERAL NOTES THE DRAWINGS AND SPECIFICATIONS ARE AN INSTRUMENT OF SERVICE AND ARE THE SOLE PROPERTY OF THE ARCHITECT. ANY RE -USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND ORDINANCES. THE GENERAL CONDITIONS FOR THIS PROJECT ARE THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA DOCUMENT A201, CURRENT EDITION. A COPY OF WHICH IS ON FILE AND MAY BE EXAMINED IN THE OFFICE OF THE ARCHITECT AND IS PART OF THE CONSTRUCTION DOCUMENTS. THIS PROJECT IS DESIGNED AND DOCUMENTED PER THE ARCHITECTS INTERPRETATION OF THE CODE REQUIREMENTS. VARIOUS GOVERNING AGENCIES SOMETIMES INTERPRET CODES, LAWS AND ORDINANCES DIFFERENTLY. THESE AGENCIES HAVE JURISDICTION TO REQUIRE CHANGES IN DESIGN AND CONSTRUCTION. ANY CHANGES OR MODIFICATIONS TO THE DESIGN MAY NECESSITATE PRICE ADJUSTMENTS. ALL OR PART OF THESE DOCUMENTS WERE GENERATED BY ELECTRONIC MEANS. THE ARCHITECT IS RELYING ON THE ACCURACY OF THE SOFTWARE EMPLOYED. THE ARCHITECTS LIABILITY IS THEREFORE LIMITED TO THE EXTENT CUSTOMARY IN THE INDUSTRY. ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD OR FROM FACE OF STUD TO FACE OF MASONRY OR FROM FACE OF MASONRY TO FACE OF MASONRY, UNLESS OTHERWISE NOTED. ALL MA50NRY DIMENSIONS ARE NOMINAL. VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY THE ARCHITECT IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING. CONTACT RESPECTIVE UTILITY COMPANIES FOR EXACT LOCATION OF UNDERGROUND SERVICES PRIOR TO START OF CONSTRUCTION. TAKE EVERY PRECAUTION NECESSARY TO PROTECT EXISTING SERVICES DURING CONSTRUCTION. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, THE SITE DESIGN AND THE TYPE OF STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PREFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. THE CONTRACTOR SHALL PERFORM SUCH SERVICES, AND FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK- DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR SPECIFIC DIMENSIONS NOT SHOWN ON DRAWINGS. SUPPLY SHOP DRAWINGS TO THE ARCHITECT FOR ALL WORK PRIOR TO ORDERING OR FABRICATING ANY ITEM. IF CONDITIONS EXIST AFTER DEMOLITION AND EXCAVATION AROUND EXISTING BUILDINGS THAT CONFLICT WITH WHAT IS SHOWN AND DESCRIBED ON DRAWINGS, CONTACT ARCHITECT PRIOR TO PROCEEDING WITH NEW CONSTRUCTION. EXISTING "WORK TO REMAIN" THAT IS DEMOLISHED FOR NEW CONSTRUCTION SHALL BE REPLACED AS ORIGINAI -LY CONSTRUCTED. AREA LOCATION MAP AREA LOCATION MAP NOT TO SCALE RELEASED FOR CONSTRUCTION SLb;ect t� cai ip anu witi all mswWons of State find Local is DEPT Of COMMUNITY SERVICES CITY O CAR EI_ / CIAN TOWNSHI INDIANA >z G J Z > - w w s:G ~ N f n-�Z� r J L !✓ fzz N w z n h M Q r 0 1Tm O c m c �� -00) -,— o ic tL i �0ia��i 0 m C m L c?�OV,Yn 3 i •w Y=p V 'm a m �. vv a c' 4 o =ova Cn OE o (A ' o N 2 — L 2 C i� lkl �rov• -m N a E 4- >; o'tR01 (Ai vice+ N �m Mm 0i L F N d u 3 V Gim0�L+. 0 hl V ,-I Y w m Em w O Q mm lJT to vo OL s� V � v n - J C as oy .�N J � `r m= Z c c a� O c L O a o ti 7 f1 U � N o�v N � m Q iF N d' C a DRAWING INDEX SHEET T- 1 ......... ..........................TITLE SHEET C-1 . ........................... . SITE LAYOUT PLAN S-0 . ............................. GENERAL NOTES S-1 . ............................ FOUNDATION PLAN S-2 . .......................... ROOF FRAMING PLAN A- 1 ............................. FIRST FLOOR PLAN A-2 ................... EXTERIOR BUILDING ELEVATIONS A-3 ................... EXTERIOR BUILDING ELEVATIONS A-4 ........ BUILDING SECTION AND INTERIOR ELEVATIONS A-5 . .............................. WALT_.. SECTIONS A- 6 ............................... WALL SECTIONS M -1 ..................... HEATING AND COOLING PLAN P -1 ................... PLUMBING AND SANITARY PLAN E -1 .............................. ELECTRICAL PLAN sola4.Ki LIDIA LOCKWOOD DESIGN ASSOCIATES, LLC • ARCHITECTS • 10610 N. PARK AVENUE, INDIANAPOLIS, INDIANA 46280 (317) 844 -1315 • (317) 844-1758 fax [DRAWN BY: D. L. LOCKWOOD ``ANN, L. LHECKED BY: G%STie D. L. LOCKWOOD NO. '+D DATE: 26 JANUARY 2012 % OF PROJECT NO.: % HI�� 11002 11 A NEW nWOO G° MPFACOLOTY REHlMMO nM FOR:o THE FAMILY CHURCH 10540 JESSUP BOULEVARD, ONDOANAPOLO, NDOANA 46200 SHEET NAME: TITLE SHEET REVISIONS: DESCRIPTION: DATE: SHEET NUMBER: OF: ONE 0 ®— © COPYR Off 2011. LOCKWOOD DES" ASSOCNTES. LLC (LO& LLC). All ORAM9YIG5. REPORTS. P1IiN5. SPECiICAT10lIS, COMPUTER f1lES, FR1D DATA MOTES AND ORER DOCUMENTS AND INSTRUMENTS PREPARED DT LDA, LLC AS MISIRlREMS OF SERVICE REWVN 7HE PROPERTY OF LDA. LLC, LD\ LLC SHALL RETAIN ALL COMMON LAND, STATUTORY AND OTTER RESERVED RKIOS INCLUDING THE COPYRO f THERETO. ANY USE OR REPRm tcnDN OF THE DOCUMENTS RTOHOUT MWfTEN PEFUMON FROM LOA, LLC 6 M VgU1KIN OF FEDM CMIOGHT LAMS.