1• HEAT PUMP 1 AND 2 SHALL BE GAS /ELECTRIC TYPE RATED AT 58000 BTUH COOLING 1850 CFM
INDOOR AIR FLOW. POWER INPUT 8.72 KW, GAS HEAT INLET — 1300000 BTUH, OUTDOOR FAN
4400 CFM, REFRIGERANT R410A, SINGLE SOURCE POWER ENTRY 8.7 KW, ECONOMIZER RELAY
KIT, OUTSIDE AIR DAMPER, START KIT, SINGLE STAGE THERMOSTAT WITH MANUAL CHANGE OVER.
UNIT WT. 700 LBS, CURB SIZE 68 3/16" X 44 1/2" AND A ROOF OPENING 48" X 37" IS
REQUIRED. 208- 24OV— SIWLE.
2. HEAT PUMP #3 3— TON -1200 CFM- 208- 24OV -1 PHASE —R22 REFRIGERANT — 3/8" AND 7/8"
LINES, ALL OWNER SUPPLIED. COOLING 36,000 BTUH — HTG SUPPLIED BY NEW FURNACE
INSTALL ON LEVER CURB. INSULATE SUCTION LINE. INSTALL ON ROOF CURB.
3. DUCT WORK — SHEET METAL AND INSULATED FLEX DUCT. INSULATE SHEET METAL WITH 1" FIBER
GLASS AND VAPOR BARRIER. SEAL ALL JOINTS — DUCTS EXPOSED TO WEATHER TO HAVE A
ADDITIONAL LIGHT ALUMINUM WEATHER TITS COVER. DIFFUSERS TO BE 12"X12" FACE — WHITE
WITH DUCT COLLAR — RETURN AIR GRILL TO BE 24"X48" EGG CRATE, CEILING TYPE WITH 14"
DIAMETER DUCT TO HP1 & HP2 HP3 TO HAVE 25"X20" GRILLE IN DOOR OF MECH ROOM.
4. ATTIC EXHAUST FANS TO BE GABLE MTD 1140 CFM EACH WITH ADJUSTABLE THERMOSTAT —
BROAN 1352 WITH SHUTTER.
5. RESTROOM FANS TO BE 110 CFM VENTING UNITS —BROAN 1676 4" DIAMETER DISCHARGE — WITH
ROOF DUCTING KIT.
6. CEILING FANS TO BE — WHITE — 4200 CFM HIGH — 3 SPEED — 52W. 120V SHORT STEM
MTO — SWITCHES IN CONTROL ROOM.
7. GAS FURNACE: 90+ AFUE GAS TYPE — 1830 CFM 0 .5' STATIC — 100000 BTUH INPUT —
INSTALLED AS TWO 3" PIPE SEALED COMBUSTION SYSTEM — DIRECT DRIVE MOTOR — STAINLESS
STEEL HEAT EXCHANGER — FILTER — BLOWER RELAY — CONTROL MODULE — PRESSURE SWITCH
AND 3 TON — 2000 CFM REFRIGERANT CONDENSER — TXV VALVE — ALL TO ASTM 82380
STANDARDS.
8. ALL WORK SK41 COMPLY WITH ALL NATIONAL, STATE, AND LOCAL CODES AND ORDINANCES PERTAINING
TO THE WORK IN THIS PROJECT.
9. BUI.aNG AIR VENT SYSTEM TO CONSIST OF 24" X 24" DOW AIR GRILLE IN CEILING — 20" X 20"
DUCT — 30" ABOVE INSULATION WITH 18" X 18' WALL EXHAUST SHUTTER WITH STEEL FRAME,
ALUMINUM BLADES WITH FELT SEALS.
HVAC PLAN-�-:
1/ ,j II Iroll
8' ro' 4 2' O'
m
LIDIA
LOCKWOOD DESIGN ASSOCIATES, LLC
• ARCHITECTS •
10610 N. PARK AVENUE, INDIANAPOLIS, INDIANA 46280
(317) 844 -1315 • (317) 844 -1758 fax
I DRAWN BY:
CHECKED BY:
mm� 0
H. MEIER
DATE:
10 NOVEMBER 2011
PROJECT NO.:
I y•
.
`
o t�`
No: 1249
$14—To 00,
.' "Ae►AAR ,t
�(,'N I T w—
a0
110021 /iyA-1 /I)
/A NEW �In ORSHOP FACO(LI T` Y RENOVATOON
FOR:
THE FAMILY CHURCH
110W JESSMP BOULEVARD, ON NA 9S, OwDoANA
SHEET NAME:
HEATING AND COOLING PLAN
REVISIONS:
DESCRIPTION: DATE:
SHEET NUMBER:
mom
OF:
OF WMM �IK PROPM wWA �
uc swu a, �.ou, ur. srauroin b+o a+auonc , oovrnart nrotro. acr use oRaoucm,