Loading...
HomeMy WebLinkAboutNNEW METER 2 AND WEATHER HEAD rcli D 2 -12 x Is LIGHTING GENERAL NOTES: 1. ALL WORK SHALL COMPLY WITH ALL NATIONAL. STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. 2. WIRING SYSTEM SHALL BE CONDUIT AND COPPER WIRE. 3. REFER TO THE MECHANICAL PLAN FOR THE D(ACT LOCATION OF ALL LIGHTING. 2 -14 POWER GENERAL NOTES: 1. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. 2. WONG SYSTEM SHALL BE CONDUIT AND WIRE, MINIMUM WIRE SIZE SHALL BE NO. 12 AWG /SOLID CONDUCTOR N0. 10 AWG. AND UP, STRANDED IN LARGE SIZES. 3. E.C. SHALL WIRE COMPLETE ALL EQUIPI►NENT FURNISHED BY OTHERS CORRDINATE LOCATIONS AND REQUIREMENTS WITH ALL TRADES AND PLANS. 4. E.C. SHALL PROVIDE ALL POWER AND CONTROL WIRING INCLUDING HVAC CONTROL WIRING. 5. M.C. SHALL SUPPLY CONTROL DEVICES AND WIRING DIAGRAMS IN LADDER FORM TO THE E.C. FOR COMPLETE INSTALLATIONS. 6. CONTRACTOR SHALL COORDINATE AND VERIFY ALL ASPECTS OF THE INCOMING SERVICES WITH THE UMAY COMPANY PRIOR TO RMING AND INCLUDE ALL UTILITY COST IN THIS BID. NEW METER 1 AND WEATHER HEAD 2 -14 ELECTRICAL PANEL 1 MAIN BREAKER 200A 10 120/230V LOAD DESIGNATION �,1 Q CKT. BKR CKT. NO KW CONN CKT. NO CKT. BKR 'Ooh Fs LOAD DESIGNATION PHASE A PHASE B HP 41 2 60 1 8.6 8.6 2 60 2 # HP 42 HP ul - 40 3 - - 4 40 - HP 42 SANCTUARY LITES 1 20 5 1.0 .8 6 20 1 SANCTUARY LITES CELING FANS 1 20 l .3 1.0 8 20 1 ATTIC FANS PULPIT LITE 1 20 9 .I .3 10 20 1 CORRIDOR LITES OUTLETS 1 20 II .6 .8 12 20 1 OUTLETS EXIT LITES 1 20 13 .1 .1 14 20 1 EMERGENCY LITES BAPTISTRY PUMP 1 20 15 1.0 1.0 Ib 20 1 OUTLETS SPARE 1 20 11 1.0 1.0 18 20 1 OUTLETS SPARE 1 20 19 1.0 1.0 20 20 1 SPARE TOTAL CONNECT LOAD (KW) 13.1 14.4 28.3 KW 144-1 AMPS 3 Ito WIRES IN 11/4" CONDUIT �r 3 x4 /0 IWRE IN 2" CONDUIT ELECTRICAL PANEL 2 MAIN BREAKER 120A 10 120/230V >� LOAD DESIGNATION O��y Q CKT. BKR CKT. NO KW COON CKT. NO CKT. BKR '00: Fs LOAD DESIGNATION PHASE A PHASE B HP 43 2 1 40 1 1.3 1 2 20 1 SPARE HP 83 - 40 3 - 1 4 20 1 SPARE FURNACE 1 20 5 1.5 A L 20 1 1 LOBBY t CLASS RMS MECH t DRESS RMS 1 20 1 .2 .6 8 20 1 RE5TRM LITES t EX FANS OUTLETS I 1 20 9 1.0 .8 10 20 1 HALLS LOBBY OUTLETS 1 20 11 .6 .2 12 20 1 FRONT DOOR LT MECH RM OUTLETS 1 20 13 5 .6 14 20 1 EXTERIOR LITES WATER COOLER 1 20 15 .5 1 16 20 1 SPARE SPARE 1 20 11 18 20 1 SPARE SPARE 7-71-23 19 20 20 1 1 SPARE TOTAL CONNECT LOAD (KW) N.L 5.4 11.5 KW 18.3AMPS 3 #4 M5 IN 11/4' CONDUIT * 3 $2 WIRES IN 11/4" CONDUIT LEGEND A 2'X4' LENS TROFFER - MAGNETIC BALLAST - 4 LAMPS - 120V B 2'X4' LENS TROFFER - MAGNETIC BALLAST - 2 LAMPS - 120V VANDAL RESISTANT LITHONIA VRI -IOOA WHITE 120V ® EXITS - EXIT SIGN LITHONIA LOMSW3ELN - RED SINGLE FACE WITH BATTERY SWITCH $3 3 WAY SWITCH SURFACE MOUNTED PORCELAN IOOW LAMP OUTLET O EMERGENCY LIGHTS - LITHONIA ELM - WHITE u QUANTON THERMOPLASTIC - 90MIN - 120V - SAW M FAN UNIT ELECTRICAL PLAN 1/4" =1' -O" 8' 01 4 2' 0' LIDIA LOCKWOOD DESIGN ASSOCIATES, LLC • ARCHITECTS o 10610 N. PARK AVENUE, INDIANAPOLIS, INDIANA 46280 (317) 844 -1315 • (317) 844 -1758 fax DRAWN BY: • M. SHAW �rI'► :`o�ot�oMt�� CHECKED BY: r7` N0. 1249 9 H. MEIER @ T S DATE: I * #Alt* 10 NOVEMBER 2011 '�, k I.T �G PROJECT NO.: 11002 FOR: THE FAMILY CHURCH 10"0 J ESSUP BOULEVARD, ONDRANA OLDS, 0900haNA O SHEET NAME: ELECTRICAL PLAN REVISIONS: SHEET NUMBER: DESCRIPTION: DATE: wool OF: �. ® uo, anta '�0 uc Mt use &. awryvaRrs aAxs canx am ar n� ooc 40 . AU °tea' u� swwoRr Nn M �rs n� t�v nr n ro �xr ux at "MM U'C aa�ton R" Wk uc IS M VRON of FOM c WMW UMM