Loading...
HomeMy WebLinkAboutCI is o L W 0 D4. 11 PLAN NOTES Oi REMOVE AND RELOCATE EXISTING DIFFUSER �2 REMOVE AND CAP EXISTING RETURN GRILLE AND ASSOCIATED DUCTWORK TO POINT INDICATED �3 REMOVE AND RELOCATE EXISTING RETURN GRILLE O4 REMOVE AND RELOCATE EXISTING FAN COIL UNIT OREMOVE EXISTING RETURN DUCTWORK AS SHOWN O6 REMOVE EXISTING SUPPLY DUCTWORK AS SHOWN (7 REMOVE EXISTING SUPPLY DIFFUSER ( REMOVE AND RELOCATE EXISTING DUCT COIL "' I I II � IHI O 6 I I O9 REMOVE AND RELOCATE EXISTING THERMOSTAT 10 REMOVE AND CAP EXISTING HWSSR AS SHOWN PARTIAL HVAC DEMO PLANS SCALE: 1/8" =1' -0" PLAN NOTES Ot RELOCATED SUPPLY DIFFUSER 0? RELOCATED RETURN GRILLE 03 • RELOCATED FAN COIL UNIT. O4 RELOCATED DUCT COIL OINSTALL 30 "X12" FIRE DAMPER IN EXISTING 30 "X12" DUCT ORELOCATED THERMOSTAT OCONNECT 1" HWS&R TO EXISTING 1 -1/2" HWS&R PARTIAL HVAC PLANS SCALE: 1/8"=l'-O" PLAN NOTES PLAN NOTES (D PIPE LOCATED UNDER SLAB U1 1 -1/2" W DROP, 1 -1/2" V RISE, 1/2" H&CW DROP TO RELOCATED STAINLESS STEEL SINK. REUSE ALL FITTINGS AND TRIM �2 REMOVE AND RELOCATE EXISTING STAINLESS STEEL SINK O2 4" S DN, 2" V RISE, 1 -1/2" CW, 1/2" HW DROP O REMOVE AND CAP EXISTING 1/2" H&CW O PIPE LOCATED UNDER SLAB 4� REMOVE AND RELOCATE EXISTING MEDICAL GAS ALARM PANELS O4 RELOCATED MEDICAL GAS ALARM PANELS O REMOVE EXISTING 2' W AS SHOWN O5 CONNECT 2' V TO EXISTING 2" V G) REMOVE EXISTING 4" S AND CLEAN -OUT AS SHOWN PARTIAL PLUMBING DEMO PLANS PARTIAL PLUMBING PLANS SCALE 1/8 " =1' -0" SCALE: 1/8 " =1' -0" W iii aaw zoz ) CFM SPECIFICATIONS HVAC 1. ALL WORK TO COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. 2. ALL DUCTWORK TO BE G60 GALVANIZED STEEL AND CONSTRUCTED PER SMACNA STANDARDS. ALL OTHER DUCTWORK TO BE CONSTRUCTED TO ti" PRESSURE CLASSIFICATION. 3. HYDRONIC PIPING TO BE TYPE L COPPER TUBING. FLUSH AND TEST PER ASME 831.9. TEST AT 1.5 TIMES DESING PRESSURE FOR 10 MINUTES WITH NO LEAKS. INSULATION SHALL BE 1" THICK FIBERGLASS WITH KRAFT REINFORCED FOIL VAPOR BARRIER SERVICE JACKET. ALL JOINTS AND SEAMS TO BE SEALED. FLAME SPREAD SMOKE DEVELOPED RATING OF 25/50 IN ACCORDANCE WITH ASTM E84. 4. ALL VALVES, PIPE, AND FITTINGS TO BE CLASS 125. 5. ALL SUPPLY AIR DUCTWORK TO BE INSULATED WITH 1.5" BLANKET GLASS FIBER INSULATION. WITH KRAFT REINFORCED FOIL FACED VAPOR JACKET. FLAME SPREAD SMOKE DEVELOPED 25/50 IN ACCORDANCE NTH ASTM E84. 6. ALL DUCTWORK TO BE SEALED PER SMACNA STANDARDS. PUAABNG 1. COMPLY WITH APPLICABLE PORTIONS OF THE UNIFORM PLUMING CODE PERTAINING TO PLUMBING MATERIALS, CONSTRUCTION, AND INSTALLATION OF PRODUCTS. 2. PROVIDE DOMESTIC WATER PIPING TYPE L COPPER TUBING NTH WROUGHT COPPER FITTINGS AND 95/5 SOLDER JOINTS. INSTALL DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE COUPLED TOGETHER. CLEAN, FLUSH AND DISENFECT WATER PIPING IN ACCORDANCE NTH AWWA C601. TEST DOMESTIC WATER SYSTEM AT A STATIC PRESSURE OF 50 PSIG ABOVE OPERATING PRESSURE (125PSIG MINIMUM) AND MAINTAIN TEST PRESSURE FOR 4 HOURS NTH NO PRESSURE LOSS. 3. PROVIDE WASTE AND VENT PIPING 1 -1/2" OR LARGER OF NO HUB CAST IRON ASTM A74. FITTINGS SHALL BE CAST IRON NO HUB CISPI 301. AT A HORIZONTAL GRADE ON NOT LESS THAN 1/8" PER FOOT. SLOPE VENT PIPING TO DRAIN CONDENSATION. TEST WASTE AND VENT NTH MINIMUM 10 FOOT OF HEAD FOR 10 HOURS NTH NO WATER LEAKS. CLEAN OUTS SHALL BE INSTALLED WHERE WHERE SHOWN ON THE DRAWING AND AS REQUIRED BY THE PLUMBING CODE. ACCEPTABLE MANUFACTURERS: ENFFIELD, ORION, AND R&G SLOANE. 4. PROVIDE SHUTOFF VALVES AS FOLLOWS: BALL VALVE- THREADED END, 150 PSI, BRONZE BODY, STANDARD PORT, TFE SEATS WITH BRONZE TRIM, NIBCO T -585. ACCEPTABLE MANUFACTURERS ARE NIBCO AND APOLLO. 5. WC- I A. FIXTURE: AMERICAN STANDARD AFWALL EL 1.6 2257.103 WHITE VITREOUS CHINA WALL HUNG SIPHON JET ELONGATED BOWL NTH TOP SPUD B. TRIM: SLOAN 111 ROYAL FLUSH VALVE NTH VACUUM BREAKER SCREW DRIVER STOP, AND QUIET EQUIPMENT C. SEAT: BENEKE 527 SS SAN]- SHIELD FR, MITE SOLID PLASTIC OPEN FRONT INTEGRAL CHECK SEAT LESS COVER D. CARRIER: J.R. SMITH COMBINATION CARRIER FITTING SUPPORT 6. LAV -1: 1. FIXTURE: AMERICAN STANDARD LUCERNE 0356.015, 20" X 18" MITE VITREOUS CHINA HIGH BACK BASIN FOR CONCEALED ARM BRACKET 2. FAUCET: CHICAGO FAUCET 786 -FC RIGID /SWING GOOSENECK SUPPLY FITTING WITH 1.6 GPM INTEGRAL FLOW CONTROL AND LAMINAR FLOW STREAM REGULATOR, AND WRIST BLADE HANDLES 3. TRIM: CHICAGO FAUCET 327 OPEN GRID STRAINER, MCGUIRE 8090 ADJUSTABLE CHROME PLATED CAST BRASS P -TRAP NTH CLEANOUT, MCGUIRE 2127 WASTE NIPPLE WITH ESCUTCHEON, CHICAGO FAUCET 1017 FLEXIBLE RISER LOOSE KEY STOP WALL SUPPLIES 4. CARRIER: J.R. SMITH 700 KW SERIES SUITABLE FOR FIXTURE r- ;'1�� 1. SPRINKLER PIPING SYSTEM SHALL BE DESIGNED, FABRICATED, AND INSTALLED BY THE FIRE PROTECTION CONTRACTOR TO MEET ALL REQUIREMENTS OF THE STATE FIRE MARSHALL AND THE LOCAL FIRE PROTECTION AUTHORITY UTILIZING THE HYDRAULIC CALCULATION METHOD. 2. DESIGN SYSTEM TO PROVIDE A PENALTY FREE INSURANCE RATING AS DETERMINED BY THE OWNER'S UNDERWRITER. 3. NFPA 13 SHALL BE A REFERENCED STANDARD. 4. ALL MATERIALS AND MANUFACTURERS SHALL HAVE FM APPROVAL. 5. ALL AREAS SHALL BE NFPA 13 LIGHT HAZARD. 6. SPRINKLER HEADS SHALL BE QUICK RESPONSE CONCEALED TYPE(VIKING B -1). 7. PIPING: ASTM 53 SCHEDULE 10 AND /OR 40 WITH ROLL GROOVED OR WELDED JOINTS; ASTM 135 UL /FM APPROVED THREADABLE LIGHTWALL BLACK STEEL NTH THREADED JOINTS. CALIBRATED BALANCING VALVE 2 -WAY MODULATING VALVE BALL VALVE MANUAL AIR VENT (TYPICAL) 2) PRESSURE &TEMPERATURE Tr PLUG ( TYPICAL) RETURN UNION (TYPICAL) i COIL SUPPLY I 3/4" DRAIN W /HOSE CONNECTION AND CAP NOTES: O1 PROVIDE BUTTERFLY VALVES IN LIEU OF BALL VALVES WHEN PIPE SIZES ARE ABOVE 2', (TYPICAL). O2 INSTALL AT LOWEST POINT IN PIPING. OINSTALL MODULATING VALVE SO THAT STEM IS VERTICAL. 2 -WAY WATER COIL PIPING DETAIL A NO SCALE 2 --� 2" loe 2" � I I EXIST ( 2' V i -1/2" + WC-1 I RELOCATED SINK 4" A� V=1 4 FLOOR LINE " EXIST 4' S SANITARY RISER DIAGRAM NO SCALE BSA DESIGN 6810 N SHADELAND AVE INDIANAPOLIS INDIANA 46220.4287 317.849.7878 PH 317.849.2288 FX O` q�4,, l No. ' �. * PE 60920307 . = yt s, STATE OFD �'.N.a.1 At1P rl ��i S� A ��►p� i t, Ittt ST. VINCENT COMMUNITY 'NOWor HEALTH NETWORK' ST. VINCENT CARMEL HOSPITAL 13500 N. Meridian Street P.O. Box 1903 Carmel, Indiana 46032 ER RENOVATION PARTIAL HVAC & PLUMBING PLANS SCALE AS NOTED CLIENT NO, 076000 DATE 13 JUNE 95 COMMISSION 076114 COORD DDF DRAWN DDF APPROVED BAB Hl