HomeMy WebLinkAboutBCONC. PORCH SLAB
112" EXPANSION MAT'L °
e
c v
° vv v °
°o
° p
p
v
po o
00 00
° o
o
v
O v ° a
v v
a v a v
c%j v ° e ° d Id
° v a° c v° v
1,_4"
ANCHOR BOLTS AT 6' O.C.
4" CONC, SLAB ON GRADE
W/ 6 MIL. VAPOR BARRIER OVER
2 "x2' CONTINUOUS PERIMETER INSULATION
GRANULAR FILL
TYPICAL FOUNDATION WALL:
* 8' 'L' BLOCK ON 8' C.M.U.
x 16 "x24' CONT. CONC. TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) 14 BARS CONT. ON
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
2,000 P.S.F.
EXTERIOR WALL AT PORCH -BRICK
SLAB FOUNDATION
3/4' RIGID INSULATION
PROVIDE ANCHOR BOLTS AT 6' O.C.
GRADE °
0
O O
Oo Oa
° p
° ° °
r.
V ° v v V
v v
a
O
°
I ° v
a v v
N
a ° v v a
v v
a
° v
1' -4'
det.estF64
112" DRYWALL (INT.)
20 STUDS AT 16' O.C.
3 114' BASE
4" CONC. SLAB ON GRADE
W/ 6 MIL. VAPOR BARRIER OVER
2 "x2' CONTINUOUS PERIMETER INSULATION
12' GRANULAR FILL
TYPICAL FOUNDATION WALL:
x B" 'L" BLOCK ON 8" C.M.U.
x 16 'x24' CONT. CONC. TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) 14 BARS CONT. ON
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
2,000 P.S.F.
TYPICAL EXTERIOR WALL AT BRICK LOCATIONS
AT SLAB FOUNDATIONS
1x2 DOOR TRIM
BY O.H. DOOR
MANUFACTURER
2x WOOD FINISH
DOOR FRAME MATERIAL
2' OVERHEAD DOOR
det.estF49
4" CONC. SLAB ON GRADE PROVIDE THICKENED 4' CONC. SLAB ON GRADE
SLAB AT FRONT W/ 6 MIL, VAPOR BARRIER
4' GRANULAR FILL 6' -8" GRANULAR FILL
v a a v
e v J ° d t d v ° d
ov °o °o o °o O� v ° °o °o °o 00* °o
° p° p° po p° p°
112" EXPANSION MATERIAL
TYPICAL FOUNDATION AT GARAGE DOOR
det.estF37
BRICK VENEER
3/4' INSULATION SHEATHING
R -13 BATT INSULATION
W/ 2 MIL. VAPOR BARRIER
m
m
m
Z
r
H
0
a�
I
I
C'V
N
cSS
NOTE: OFFSET FACE OF STUD 112'
FROM FACE OF FOUND. WALL
2x4 STUDS AT 16" D.C.
ON
112' DRYWALL
4' CONC. SLAB ON GRADE
W/ 6 MIL. VAPOR BARRIER OVER
2'x2' CONTINUOUS PERIMETER INSULATION
PROVIDE ANCHOR BOLTS AT 6' O.C.
12' GRANULAR FILL
TYPICAL FOUNDATION WALL:
x
8''1" BLOCK ON i2' CAP BLOCK
x
16'x24' CONT. CONC. TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) #4 BARS CONT. ON
CERTIFIED COMPACTED FILL W/
h1fV. tlCRH11YU LPYFI,III OF
2,000 P.S.F.
EXTERIOR WALL AT HOUSE SLAB FOUNDATION
NOTE: OFFSET FACE OF STUD 112'
HORIZONTAL SIDING FROM FACE OF FOUND. WALL
3/4" INSULATION SHEATHING
R -13 BATT INSULATION
W/ 2 MIL. VAPOR BARRIER
o
FIN. GRADE °
O °O
o °o
o °o
a ° °
°
Z v v v v
v v
O �
co I ° e v °
I -
N N
vv
a
° d v ° d
det.estF24
20 STUDS AT 16' O.C.
112' DRYWALL
4" CONC. SLAB ON GRADE
W/ 6 MIL. VAPOR BARRIER OVER
2'x2' CONTINUOUS PERIMETER INSULATION
PROVIDE ANCHOR BOLTS AT 6' O.C.
12" GRANULAR FILL
TYPICAL FOUNDATION WALL:
4' CONC. SLAB ON GRADE W/
THICKENED SLAB AT FRONT AND
2% DOWNSLOPE TOWARDS FRONT 2% SLOPE
v s a v v q c v a q v v v
1 -112' OVERHANG AT BLOCK
O
°
° a
O
°o °o °o °o
o' Oo 0,- Oa
0,- FIN. GRADE a °o °a 00* °.*
v vv
'd V,
°
V
v °
C_Q
v v v
o°
v � v
1' -4"
GRANULAR FILL
TYPICAL FOUNDATION WALL:
x 8" CAP BLOCK
x 16 "x24" CONT. CONC. TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) 14 BARS CONT . ON
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
2,000 P.S.F.
EXTERIOR FOUNDATION AT CONC. PORCH OVERHANG
HORIZONTAL SIDING
3/4" INSULATION SHEATHING
4" CONC. SLAB W /THICKENED EDGE
112" EXPANSION JOINT MATERIAL
It 112' GRANULAR FILL
8' 'L" BLOCK ON 8" C.M.U. °
x 16 "x24" CONT. CONC. TRENCH "'
FOOTING ON VIRGIN SOIL OR
W/ (2) #4 BARS CONT. ON
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
1'4' I 2,000 P.S.F.
EXTERIOR WALL AT HOUSE SLAB FOUNDATION
112" DRYWALL
2x4 STUDS AT 16" O.C.
4" CONC. SLAB ON GRADE
W/ 6 MIL. VAPOR BARRIER
MIN. 4' GRAVEL BASE
0
I
CV
NOTE: OFFSET FACE OF STUD 112"
FROM FACE OF FOUND. WALL
det.estFi8
112" EXT. SHEATHING
HORIZONTAL SIDING
PROVIDE ANCHOR BOLTS AT 6' O.C.
° d e FIN. GRADE
O O °
°° °° °° TYPICAL FOUNDATION WALL:
°° °° °° x 8' CAP BLOCK ON 8' C.M.U.
I V ° d ° e
16'x24' CONT. CONC, TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) #4 BARS CONT. ON
A v° d ° e CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
vv
2, 000 P.S.F.
EXTERIOR WALL AT GARAGE SLAB FOUNDATION
det.estF17
NOTE: OFFSET FACE OF STUD 112"
FROM FACE OF FOUND. WALL
CD
d ° a
L
V
OO Oo
Oo
a 11
O v a o ° 0
O 0c O° Oo Oo
0 p° p°
p°
v v
v v v
° a °
v v
a a ° a
v
v ° e
° v n
v ° a v v
EXTERIOR WALL AT PORCH
AT SIDING LOCATIONS
112" DRYWALL
det.estF16
112" DRYWALL
PROVIDE ANCHOR BOLTS AT 6' O. C
4" CONC. SLAB ON GRADE
W/ 6 MIL. VAPOR BARRIER OVER
2'x2' CONTINUOUS PERIMETER INSULATION
12' GRANULAR FILL
TYPICAL FOUNDATION WALL:
8' "L' BLOCK ON 8' C.M.U.
* 16 "0" CONT. CONC. TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) 14 BARS CONT. ON
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
2,000 P.S.F.
det.estF14
0
112' DRYWALL
2x4 AT 16" O.C.
4' CONC. THICKENED SLAB
w 3 114' BASE W/ 6 MIL. VAPOR BARRIER
w
I
d
0
° °
A v a
t, a v t,
0o a s p p a
00 00
Oo oj c O°
°° °° q °�
O° i 0 o�
WIDTH - SEE Si
C)
THICKENED SL
12' GRANULAR FILL
A T f W :L L. yr
Erg det . esf�3
�WT OF
r
N M
r
H
Z
a
u
cSS
w
w
g
P �
N
`l^Y�■I
W
g
I--I
O
r .
r
w
Z
w
w
w
cn
c=
c
J
I--I
a
z
0-
0
W
0
H
0
z
o
o
H
H
Q
>
°
�-
o
Lu
a
z
Q
o�
°z
C)
U'
c
o
CL)
3r.
I
U—
a
>
>
>
cc
W
U-i
W
co
Q
=
�
CD
w
Z
0
=
cn
J
I--I
a
0-
W
0
0
w
W
=
cn
J
I--I
a
W
0
z
o
o
�
H
Q
°
�-
o
r"
a
z
Q
o�
°z
C)
U'
c
o
CL)
LA_
I
U—
CV
-m
`n
C)
U-i
�
CD
__j
~
X
z
m
Z
a
z
Q
a
a
c
o
a
°
DATE:
gip.-