Loading...
HomeMy WebLinkAboutA1 R M' L KI I H F Y c ca E D U a� a� U U) 0 T N O C Q 0 V Cn 0 a� Y B Cz a� E3 U O A 1 N C: O N 0 o� We 1i U W 2 i3 I I I 1 I I I I I a� c J N Q_ a co T I `I I I I I I I I I s Adjacent Property Zoned B -3 7 A Existing Lawn. No Modifications J lu 11 Old Meric S, Existing landscaping to remain Existing flood lights to remain Zoned, S -2 -_ Existing drain inlet to remain - - M15 Generator enclosure A7 New condensing units o Area of underground utilities -- - -- r Existing landscaping _ to remain C° \ - - - -- - - - -- -� Meridian Crossing 12 13 14 15 Existing Bank Drive Through to Remain �- -- -- -- A7 C=— 7—) I(= - - 1--91" - - - 1 I� I i Existing Parking to Remain - No Modifications -- Property Line — Illinois St. Site Plan 1 " = 40' -0" 0 10' 20' 40' 3 14 NORTH - _5 6 7 _� 8 0 10 11 Adjacent Property Zoned PUD 12 13 14 17 Adjacent Property Zoned B -6 15 Zoned S -2 W Main St. 1 -465 A16 Location Map Not to Scale 16 17 19 20 - -- 21 22 123 124 Drawing Index: Architectural A6 Site Plan A7 Schedules & Details Plumbing / Electrical R PE1 Plumbing / Electrical - Site Plan E6 Electrical - Schedules / Details Structural S1 Generator Enclosure and Canopy Plans and Sections Civil C101 Existing Conditions and Demolition Plan C301 Grading and Utility Plan C302 Details C401 Erosion Control Plan C402 Erosion Control Notes and Details P Landscaping L101 Landscape Plan Carmel Specialty Surgery Center Tenant Improvement Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.3757 / f 866.760.3757 ISSUED FOR: Zoning Review 4/20012 TI Permit 5!7/2012 N20 Drawing Index -- ---- - - - - -- Site Improvements 5/23/2012 Not to Scale N General Project Information: Project Name: Carmel Specialty Surgical Center Zoned Project Address: 11590 N. Meridian Street S -2 Carmel, Indiana 46032 -6954 Owner: Carmel Specialty Surgical Center - Proposed Use: Tenant Improvement / Ambulatory Surgical Center (ASC) M Code Enforcement Jurisdiction: City of Carmel Applicable Building Codes: Building Code - 2006 International Building Code with Indiana Amendments Property Line Electrical Code - 2008 National Electrical Code with Indiana Amendments .— — — Plumbing Code - 1997 Uniform Plumbing Code with Indiana Amendments `\ Mechanical Code - 2006 International Mechanical Code with 2008 Indiana Amendments L Energy Code - Indiana Energy Conservation Code 2010 (ASHRAE/IESNA 90.1 2007 Edition) Accessibility Code - 2009 International Building Code (ICC /ANSI A117.1 -2003) Fire Code - 2006 International Fire Code with 2008 Indiana Amendments Chapter 20 of NFPA 101, Life Safety Code, 2006 edition (State) Chapter 20 of NFPA 101, Life Safety Code, 2000 edition (Federal) 2001 AIA Guidelines for Design and Construction of Health Care Facilities K Applicable City Ordinances: City Code of Carmel, Indiana Building Data: Zoning Classification: B -3/S -2 Occupancy Type: B, Business Occupancy Type (2000 NFPA -101): Ambulatory Health Care J Construction Type: II Building Height: 80 feet / 6 stories Automatic Sprinkler System: Fully sprinklered Building Area: 159,000 SF 1 hour separation provided between ASC occupancy and adjacent tenant Accessibility: H Construction has been designed to meet the minimum requirements of the Americans with Disabilities Act (ADA) of 2010 and ANSI 117.1 -2003. G2o Code Summary Not to Scale G I, Kirk A. Gastinger, FAIA, Indiana registered Architect #AR19600070, do hereby accept professional '�� responsibility for the attached architectural drawings fi . °r-«r (numbered A6 and A7). I hereby disclaim any if responsibility for all other drawings included in these construction documents, they being the responsibility of _� :,1ATE GF F the design professionals whose names and signed statements appear hereinafter. �Z I, Jerot Vance Pearson, PE, Indiana registered Engineer #PE10403240, do hereby accept professional responsibility for the attached engineering drawings (numbered PE1 and E6). I hereby disclaim E any responsibility for all other specifications included in these construction documents, they being the responsibility of the design professionals whose names and signed statements appear hereinafter. e�a\a�s Ls0.� I, Michael J. Falbe, PE, Indiana registered Engineer �4 #PE10403976, do hereby accept professional D y responsibility for the attached engineering drawings (numbered S1). I hereby disclaim any responsibility for all other specifications included in these construction documents, they being the responsibility of the design professionals whose names and signed statements appear hereinafter. CD C Project Site I, David A. Lach, PE, Indiana registered Engineer Drawn B, #PE10000126, do hereby accept professional Checked responsibility for the attached engineering drawings (numbered C101 through C402). I hereby disclaim any responsibility for all other specifications included in \ these construction documents, they being the responsibility of the design professionals whose names B and signed statements appear hereinafter. 19 Ago Professional Disclaimers NORTH No Scale 20 1 21 1 22 23 Gastinger Walker Harden Architects 817 Wyandotte Kansas City, MO 64105 816 4218200 p 816 4211262 f designwithinsight.com Electrical / Plumbing o t— W 116th St. CD 8801 Ballentine, Suite 200 W 106th St. 1 -465 A16 Location Map Not to Scale 16 17 19 20 - -- 21 22 123 124 Drawing Index: Architectural A6 Site Plan A7 Schedules & Details Plumbing / Electrical R PE1 Plumbing / Electrical - Site Plan E6 Electrical - Schedules / Details Structural S1 Generator Enclosure and Canopy Plans and Sections Civil C101 Existing Conditions and Demolition Plan C301 Grading and Utility Plan C302 Details C401 Erosion Control Plan C402 Erosion Control Notes and Details P Landscaping L101 Landscape Plan Carmel Specialty Surgery Center Tenant Improvement Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.3757 / f 866.760.3757 ISSUED FOR: Zoning Review 4/20012 TI Permit 5!7/2012 N20 Drawing Index -- ---- - - - - -- Site Improvements 5/23/2012 Not to Scale N General Project Information: Project Name: Carmel Specialty Surgical Center Zoned Project Address: 11590 N. Meridian Street S -2 Carmel, Indiana 46032 -6954 Owner: Carmel Specialty Surgical Center - Proposed Use: Tenant Improvement / Ambulatory Surgical Center (ASC) M Code Enforcement Jurisdiction: City of Carmel Applicable Building Codes: Building Code - 2006 International Building Code with Indiana Amendments Property Line Electrical Code - 2008 National Electrical Code with Indiana Amendments .— — — Plumbing Code - 1997 Uniform Plumbing Code with Indiana Amendments `\ Mechanical Code - 2006 International Mechanical Code with 2008 Indiana Amendments L Energy Code - Indiana Energy Conservation Code 2010 (ASHRAE/IESNA 90.1 2007 Edition) Accessibility Code - 2009 International Building Code (ICC /ANSI A117.1 -2003) Fire Code - 2006 International Fire Code with 2008 Indiana Amendments Chapter 20 of NFPA 101, Life Safety Code, 2006 edition (State) Chapter 20 of NFPA 101, Life Safety Code, 2000 edition (Federal) 2001 AIA Guidelines for Design and Construction of Health Care Facilities K Applicable City Ordinances: City Code of Carmel, Indiana Building Data: Zoning Classification: B -3/S -2 Occupancy Type: B, Business Occupancy Type (2000 NFPA -101): Ambulatory Health Care J Construction Type: II Building Height: 80 feet / 6 stories Automatic Sprinkler System: Fully sprinklered Building Area: 159,000 SF 1 hour separation provided between ASC occupancy and adjacent tenant Accessibility: H Construction has been designed to meet the minimum requirements of the Americans with Disabilities Act (ADA) of 2010 and ANSI 117.1 -2003. G2o Code Summary Not to Scale G I, Kirk A. Gastinger, FAIA, Indiana registered Architect #AR19600070, do hereby accept professional '�� responsibility for the attached architectural drawings fi . °r-«r (numbered A6 and A7). I hereby disclaim any if responsibility for all other drawings included in these construction documents, they being the responsibility of _� :,1ATE GF F the design professionals whose names and signed statements appear hereinafter. �Z I, Jerot Vance Pearson, PE, Indiana registered Engineer #PE10403240, do hereby accept professional responsibility for the attached engineering drawings (numbered PE1 and E6). I hereby disclaim E any responsibility for all other specifications included in these construction documents, they being the responsibility of the design professionals whose names and signed statements appear hereinafter. e�a\a�s Ls0.� I, Michael J. Falbe, PE, Indiana registered Engineer �4 #PE10403976, do hereby accept professional D y responsibility for the attached engineering drawings (numbered S1). I hereby disclaim any responsibility for all other specifications included in these construction documents, they being the responsibility of the design professionals whose names and signed statements appear hereinafter. CD C Project Site I, David A. Lach, PE, Indiana registered Engineer Drawn B, #PE10000126, do hereby accept professional Checked responsibility for the attached engineering drawings (numbered C101 through C402). I hereby disclaim any responsibility for all other specifications included in \ these construction documents, they being the responsibility of the design professionals whose names B and signed statements appear hereinafter. 19 Ago Professional Disclaimers NORTH No Scale 20 1 21 1 22 23 Gastinger Walker Harden Architects 817 Wyandotte Kansas City, MO 64105 816 4218200 p 816 4211262 f designwithinsight.com Electrical / Plumbing PKMR Engineers 8801 Ballentine, Suite 200 0 C �. tosnav s m .� ,� y Overland Park, KS 66214 n� _. ° = a � 0 'a ° m y � S 3 t 913.492.2400 / 2437 fax 07 0 m � o'� �r ` Mechanical j to a y Wiegmann Associates, Inc. W i-v r, M1 750 Fountain Lakes Blvd. ®K rt Z St. Charles, MO 63301 > > @ = 0- rt I'D "'i tD * co ? y ° 314.409.3350 �} CL ref •Q y A o O Structural o d v o _.� z Bob D. Campbell & Co. o a �' ° `�° ° ° n 4338 Belleview Ai. CL Kansas City, MO 64111 816.531.4144 A'rt' n gn tin C A n O 5 4 M: S " in Civil Cripe Architects + Engineers =• '. 1=1 3939 Priority Way South Drive, Suite 400 a a rb 2 c Indianapolis, IN 46240 ' a A `D "' fD — ` = � P+ � n 317.844.6777 a n ro Landscape 0 ° o @ a Vive Exterior Design 15325 Herrman Blvd. Noblesville, IN 46060 N 317.773.9933 KEY PLAN Site Plan • "UN /j}%N °s .,yes A 24 Project Number: 2012.105 n Copyright 2012