HomeMy WebLinkAboutA1
R
M'
L
KI
I
H
F
Y
c
ca
E D
U
a�
a�
U
U)
0
T
N
O C
Q
0
V
Cn
0
a�
Y
B
Cz
a�
E3
U
O
A
1
N
C:
O
N 0
o�
We
1i
U
W
2 i3
I
I
I
1
I
I
I
I
I
a�
c
J
N
Q_
a
co
T
I
`I
I
I
I
I
I
I
I
I
s
Adjacent Property Zoned
B -3
7
A
Existing Lawn.
No Modifications
J
lu
11
Old Meric S,
Existing landscaping to remain
Existing flood lights to remain Zoned,
S -2
-_ Existing drain inlet to remain - -
M15 Generator enclosure
A7 New condensing units
o Area of underground utilities
-- - --
r Existing landscaping
_ to remain
C° \
- - - -- - - - -- -�
Meridian Crossing
12
13
14
15
Existing Bank Drive
Through to Remain �- -- -- -- A7
C=— 7—) I(=
- - 1--91" - - -
1
I�
I
i
Existing Parking to Remain -
No Modifications --
Property Line —
Illinois St.
Site Plan
1 " = 40' -0"
0 10' 20' 40'
3 14
NORTH
- _5
6 7 _� 8
0
10 11
Adjacent Property Zoned
PUD
12
13
14
17
Adjacent Property Zoned
B -6
15
Zoned
S -2
W Main St.
1 -465
A16 Location Map
Not to Scale
16 17
19 20 - -- 21 22 123 124
Drawing Index:
Architectural
A6 Site Plan
A7 Schedules & Details
Plumbing / Electrical R
PE1 Plumbing / Electrical - Site Plan
E6 Electrical - Schedules / Details
Structural
S1 Generator Enclosure and Canopy Plans and Sections
Civil
C101 Existing Conditions and Demolition Plan
C301 Grading and Utility Plan
C302 Details
C401 Erosion Control Plan
C402 Erosion Control Notes and Details
P
Landscaping
L101 Landscape Plan
Carmel Specialty
Surgery Center
Tenant Improvement
Meridian Crossing First Floor
11590 N Meridian Street
Carmel, IN 46032
923 NE Woods Chapel Road, Suite 550
Lee's Summit, MO
v 866.700.3757 / f 866.760.3757
ISSUED FOR:
Zoning Review 4/20012
TI Permit 5!7/2012
N20 Drawing Index -- ---- - - - - -- Site Improvements 5/23/2012
Not to Scale N
General Project Information:
Project Name: Carmel Specialty Surgical Center
Zoned Project Address: 11590 N. Meridian Street
S -2 Carmel, Indiana 46032 -6954
Owner: Carmel Specialty Surgical Center -
Proposed Use: Tenant Improvement / Ambulatory Surgical Center (ASC) M
Code Enforcement Jurisdiction: City of Carmel
Applicable Building Codes:
Building Code - 2006 International Building Code with Indiana Amendments
Property Line Electrical Code - 2008 National Electrical Code with Indiana Amendments
.— — — Plumbing Code - 1997 Uniform Plumbing Code with Indiana Amendments
`\ Mechanical Code - 2006 International Mechanical Code with 2008 Indiana Amendments L
Energy Code - Indiana Energy Conservation Code 2010 (ASHRAE/IESNA 90.1 2007 Edition)
Accessibility Code - 2009 International Building Code (ICC /ANSI A117.1 -2003)
Fire Code - 2006 International Fire Code with 2008 Indiana Amendments
Chapter 20 of NFPA 101, Life Safety Code, 2006 edition (State)
Chapter 20 of NFPA 101, Life Safety Code, 2000 edition (Federal)
2001 AIA Guidelines for Design and Construction of Health Care Facilities
K
Applicable City Ordinances:
City Code of Carmel, Indiana
Building Data:
Zoning Classification: B -3/S -2
Occupancy Type: B, Business
Occupancy Type (2000 NFPA -101): Ambulatory Health Care J
Construction Type: II
Building Height: 80 feet / 6 stories
Automatic Sprinkler System: Fully sprinklered
Building Area: 159,000 SF
1 hour separation provided between ASC occupancy and adjacent tenant
Accessibility: H
Construction has been designed to meet the minimum requirements of the Americans with
Disabilities Act (ADA) of 2010 and ANSI 117.1 -2003.
G2o Code Summary
Not to Scale G
I, Kirk A. Gastinger, FAIA, Indiana registered Architect
#AR19600070, do hereby accept professional '��
responsibility for the attached architectural drawings fi . °r-«r
(numbered A6 and A7). I hereby disclaim any if
responsibility for all other drawings included in these
construction documents, they being the responsibility of _� :,1ATE GF F
the design professionals whose names and signed
statements appear hereinafter.
�Z
I, Jerot Vance Pearson, PE, Indiana registered
Engineer #PE10403240, do hereby accept
professional responsibility for the attached engineering
drawings (numbered PE1 and E6). I hereby disclaim E
any responsibility for all other specifications included in
these construction documents, they being the
responsibility of the design professionals whose names
and signed statements appear hereinafter.
e�a\a�s Ls0.� I, Michael J. Falbe, PE, Indiana registered Engineer
�4 #PE10403976, do hereby accept professional D
y responsibility for the attached engineering drawings
(numbered S1). I hereby disclaim any responsibility for
all other specifications included in these construction
documents, they being the responsibility of the design
professionals whose names and signed statements
appear hereinafter.
CD
C
Project Site I, David A. Lach, PE, Indiana registered Engineer Drawn B,
#PE10000126, do hereby accept professional Checked
responsibility for the attached engineering drawings
(numbered C101 through C402). I hereby disclaim any
responsibility for all other specifications included in
\ these construction documents, they being the
responsibility of the design professionals whose names B
and signed statements appear hereinafter.
19
Ago Professional Disclaimers
NORTH No Scale
20 1 21 1 22
23
Gastinger
Walker
Harden
Architects
817 Wyandotte
Kansas City, MO 64105
816 4218200 p
816 4211262 f
designwithinsight.com
Electrical / Plumbing
o
t—
W 116th St. CD
8801 Ballentine, Suite 200
W 106th St.
1 -465
A16 Location Map
Not to Scale
16 17
19 20 - -- 21 22 123 124
Drawing Index:
Architectural
A6 Site Plan
A7 Schedules & Details
Plumbing / Electrical R
PE1 Plumbing / Electrical - Site Plan
E6 Electrical - Schedules / Details
Structural
S1 Generator Enclosure and Canopy Plans and Sections
Civil
C101 Existing Conditions and Demolition Plan
C301 Grading and Utility Plan
C302 Details
C401 Erosion Control Plan
C402 Erosion Control Notes and Details
P
Landscaping
L101 Landscape Plan
Carmel Specialty
Surgery Center
Tenant Improvement
Meridian Crossing First Floor
11590 N Meridian Street
Carmel, IN 46032
923 NE Woods Chapel Road, Suite 550
Lee's Summit, MO
v 866.700.3757 / f 866.760.3757
ISSUED FOR:
Zoning Review 4/20012
TI Permit 5!7/2012
N20 Drawing Index -- ---- - - - - -- Site Improvements 5/23/2012
Not to Scale N
General Project Information:
Project Name: Carmel Specialty Surgical Center
Zoned Project Address: 11590 N. Meridian Street
S -2 Carmel, Indiana 46032 -6954
Owner: Carmel Specialty Surgical Center -
Proposed Use: Tenant Improvement / Ambulatory Surgical Center (ASC) M
Code Enforcement Jurisdiction: City of Carmel
Applicable Building Codes:
Building Code - 2006 International Building Code with Indiana Amendments
Property Line Electrical Code - 2008 National Electrical Code with Indiana Amendments
.— — — Plumbing Code - 1997 Uniform Plumbing Code with Indiana Amendments
`\ Mechanical Code - 2006 International Mechanical Code with 2008 Indiana Amendments L
Energy Code - Indiana Energy Conservation Code 2010 (ASHRAE/IESNA 90.1 2007 Edition)
Accessibility Code - 2009 International Building Code (ICC /ANSI A117.1 -2003)
Fire Code - 2006 International Fire Code with 2008 Indiana Amendments
Chapter 20 of NFPA 101, Life Safety Code, 2006 edition (State)
Chapter 20 of NFPA 101, Life Safety Code, 2000 edition (Federal)
2001 AIA Guidelines for Design and Construction of Health Care Facilities
K
Applicable City Ordinances:
City Code of Carmel, Indiana
Building Data:
Zoning Classification: B -3/S -2
Occupancy Type: B, Business
Occupancy Type (2000 NFPA -101): Ambulatory Health Care J
Construction Type: II
Building Height: 80 feet / 6 stories
Automatic Sprinkler System: Fully sprinklered
Building Area: 159,000 SF
1 hour separation provided between ASC occupancy and adjacent tenant
Accessibility: H
Construction has been designed to meet the minimum requirements of the Americans with
Disabilities Act (ADA) of 2010 and ANSI 117.1 -2003.
G2o Code Summary
Not to Scale G
I, Kirk A. Gastinger, FAIA, Indiana registered Architect
#AR19600070, do hereby accept professional '��
responsibility for the attached architectural drawings fi . °r-«r
(numbered A6 and A7). I hereby disclaim any if
responsibility for all other drawings included in these
construction documents, they being the responsibility of _� :,1ATE GF F
the design professionals whose names and signed
statements appear hereinafter.
�Z
I, Jerot Vance Pearson, PE, Indiana registered
Engineer #PE10403240, do hereby accept
professional responsibility for the attached engineering
drawings (numbered PE1 and E6). I hereby disclaim E
any responsibility for all other specifications included in
these construction documents, they being the
responsibility of the design professionals whose names
and signed statements appear hereinafter.
e�a\a�s Ls0.� I, Michael J. Falbe, PE, Indiana registered Engineer
�4 #PE10403976, do hereby accept professional D
y responsibility for the attached engineering drawings
(numbered S1). I hereby disclaim any responsibility for
all other specifications included in these construction
documents, they being the responsibility of the design
professionals whose names and signed statements
appear hereinafter.
CD
C
Project Site I, David A. Lach, PE, Indiana registered Engineer Drawn B,
#PE10000126, do hereby accept professional Checked
responsibility for the attached engineering drawings
(numbered C101 through C402). I hereby disclaim any
responsibility for all other specifications included in
\ these construction documents, they being the
responsibility of the design professionals whose names B
and signed statements appear hereinafter.
19
Ago Professional Disclaimers
NORTH No Scale
20 1 21 1 22
23
Gastinger
Walker
Harden
Architects
817 Wyandotte
Kansas City, MO 64105
816 4218200 p
816 4211262 f
designwithinsight.com
Electrical / Plumbing
PKMR Engineers
8801 Ballentine, Suite 200
0 C
�.
tosnav s
m .� ,� y
Overland Park, KS 66214
n� _. °
= a �
0
'a ° m y �
S 3 t
913.492.2400 / 2437 fax
07 0
m � o'� �r
`
Mechanical
j to
a y
Wiegmann Associates, Inc.
W i-v r, M1
750 Fountain Lakes Blvd.
®K rt Z
St. Charles, MO 63301
> >
@ =
0- rt I'D "'i
tD * co ? y °
314.409.3350
�}
CL
ref •Q y
A o O
Structural
o d
v o
_.� z
Bob D. Campbell & Co.
o a �'
° `�° ° ° n
4338 Belleview
Ai.
CL
Kansas City, MO 64111
816.531.4144
A'rt' n
gn
tin
C A n
O 5 4 M: S
"
in
Civil
Cripe Architects + Engineers
=•
'. 1=1
3939 Priority Way South Drive, Suite 400
a
a rb
2 c
Indianapolis, IN 46240
'
a
A `D "' fD — `
=
�
P+
� n
317.844.6777
a
n ro
Landscape
0 °
o @ a
Vive Exterior Design
15325 Herrman Blvd.
Noblesville, IN 46060
N
317.773.9933
KEY PLAN
Site Plan
• "UN /j}%N °s .,yes
A
24 Project Number: 2012.105 n Copyright 2012