HomeMy WebLinkAboutCIN X I 2 M L K J 19 A F E C f S t i i i 1 ii 5 i s i f i f i i 3 M 5 i. 7 io 7 10 12 13 14 15 16 17 119 120 121 122 123 124 GRADE BACKFILL i- _� _ + YELLOW "CAUTION" TAPE 12 TO 18" ABOVE DUCTBANK UNDISTURBED EARTH 3" MINIMUM CLEARANCE R (0 4 NUMBER OF CONDUITS PER PLANS COMPLETELY ENCAPSULATE DUCT BANK WITH CONCRETE — NO VOIDS OR POCKETS. CONCRETE SHALL CONTAIN RED ADMIXTURE. CE i €� Q a a BASE SPACERS O. AT ..._ MIN. OF 5' -0" C. .... .... 3 :...m._ °_.. 3 .... 3" MINIMUM1..... _ ° CLEARANCE i I UNDERGROUND ELECTRICAL DUCTBANK DETAIL NOT TO SCALE NOT TO SCALE SITE PLAN KEYED NOTES O REFER TO RISER DIAGRAM FOR NUMBER /SIZES OF WIRE AND CONDUIT REQUIRED. O FEEDER TO BE INSTALLED IN CONCRETE — REFER TO DUCTBANK DETAIL THIS SHEET FOR WORK. 3O 60 AMP, 3 —POLE, NON— FUSED, HEAVY —DUTY DISCONNECT SWITCH IN NEMA 3R ENCLOSURE. MOUNT DISCONNECT AT CONDENSING UNIT WITH SUITABLE STEEL SUPPORTS A MINIMUM OF 36" ABOVE FINISH GRADE. 4O 30 AMP, 3 —POLE, NON— FUSED, HEAVY —DUTY DISCONNECT SWITCH IN NEMA 3R ENCLOSURE. MOUNT DISCONNECT AT CONDENSING UNIT WITH SUITABLE STEEL SUPPORTS A MINIMUM OF 36" ABOVE FINISH GRADE. 5O CONNECT NEW 4" STORM PIPING TO EXISTING CONCEALED STORM PIPING. CONTRACTOR TO VERIFY EXACT SIZE AND LOCATION OF EXISTING PIPING AND NOTIFY ENGINEER IMMEDIATLY IF LESS THAN 47 . 6O PHOTOCELL FOR CONTROL OF EXTERIOR EGRESS FIXTURE MOUNT IN CORNER OF CANOPY WHERE SHOWN. PHOTOCELL SHALL BE CAPABLE OF DISTINGUISHING BETWEEN ARTIFICIAL AND NATURAL LIGHT. O7 ROUTE AND CONNECT TO EXISTING EXTERIOR LIGHTING CIRCUIT. ROOF DRAIN SCHEDULE 1 10" THICK CONCRETE PAD, WITH REINFORCING INSTALL ON GENERATOR MODEL SERVICE STEEL AS REQUIRED, ON 6" OF CRUSHED CLEAN SCREEN WALL (TYP.) REMARKS MARK ROCK, PAD SHALL EXTEND 4" ON ALL SIDES. NUMBER 1 15 SIZE COORDINATE WITH GENERATOR MANUFACTURER. BATTERY CHARGER W WP EXTEND AND CONNECT TO GENERATOR 3000 E ANNUNCIATOR PANEL IN RECEPTION 102. ._.e..._ �....._ .................................... ............................... EXACT NUMBER AND TYPE OF WIRE AS 8 WIRE ` 1. PROVIDE CAST IRON DOME. REQUIRED BY MANUFACTURER. INSTALL ` SAME IN CONDUIT. O� 46 LN 1 48 J GFl /WP ° 125 KW DIESEL FUELED STANDBY GENERATOR. 24 —HOUR SUBBASE FUEL TANK WITH SECONDARY CONTAINMENT BASIN. EXACT LOCATION OF GENERATOR SHALL BE COORDINATED WITH THE BLOCK HEATER W INSTALL RECEPTACLE ARCHITECT AND OWNER. 9 7 INSIDE ENCLOSURE AT GENERATOR FRAME ELS ENLARGED GENERATOR PLAN NOT TO SCALE SITE PLAN KEYED NOTES O REFER TO RISER DIAGRAM FOR NUMBER /SIZES OF WIRE AND CONDUIT REQUIRED. O FEEDER TO BE INSTALLED IN CONCRETE — REFER TO DUCTBANK DETAIL THIS SHEET FOR WORK. 3O 60 AMP, 3 —POLE, NON— FUSED, HEAVY —DUTY DISCONNECT SWITCH IN NEMA 3R ENCLOSURE. MOUNT DISCONNECT AT CONDENSING UNIT WITH SUITABLE STEEL SUPPORTS A MINIMUM OF 36" ABOVE FINISH GRADE. 4O 30 AMP, 3 —POLE, NON— FUSED, HEAVY —DUTY DISCONNECT SWITCH IN NEMA 3R ENCLOSURE. MOUNT DISCONNECT AT CONDENSING UNIT WITH SUITABLE STEEL SUPPORTS A MINIMUM OF 36" ABOVE FINISH GRADE. 5O CONNECT NEW 4" STORM PIPING TO EXISTING CONCEALED STORM PIPING. CONTRACTOR TO VERIFY EXACT SIZE AND LOCATION OF EXISTING PIPING AND NOTIFY ENGINEER IMMEDIATLY IF LESS THAN 47 . 6O PHOTOCELL FOR CONTROL OF EXTERIOR EGRESS FIXTURE MOUNT IN CORNER OF CANOPY WHERE SHOWN. PHOTOCELL SHALL BE CAPABLE OF DISTINGUISHING BETWEEN ARTIFICIAL AND NATURAL LIGHT. O7 ROUTE AND CONNECT TO EXISTING EXTERIOR LIGHTING CIRCUIT. ROOF DRAIN SCHEDULE 1 PLAN MANUFACTURER MODEL SERVICE TOP /GRATE WASTE REMARKS MARK 1 13 NUMBER 1 15 SIZE SIZE 1 18 RD -1 WADE 3000 ROOF DRAIN N/A 4" 1 REMARKS 7 1. PROVIDE CAST IRON DOME. A1 1 1 16 1 1 8 9 1 10 1 11 1 12 1 13 1 14 1 15 1 16 1 17 1 18 1 19 1 20 1 21 1 1 2 3 4 5 7 Carmel Specialty Surgery Center R Tenant Improvement Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 Q 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.3757 / f 866.760.3757 P ISSUED FOR: Permit 7 May 2012 Site Improvements 23 May 2012 N M L K J 1'! ■ G F E .« V. PEgRs!,�. 0 No. PE10403240 c .o'. STATE OF - NALI������� Z i 12 Gastinger Walker Harden Architects 817 Wyandotte Kansas City, MO 64105 816 4218200 p 816 421 1262 f designwithinsight.com Electrical I Plumbing PKMR Engineers 8801 Ballentine, Suite 200 Overland Park, KS 66214 913.492.2400 1 2437 fax Mechanical Wiegmann Associates, Inc. 750 Fountain Lakes Blvd. St. Charles, MO 63301 314.409.3350 Structural Bob D. Campbell & Co. 4338 Belleview Kansas City, MO 64111 816.531.4144 Civil Cripe Architects + Engineers 3939 Priority Way South Drive, Suite 400 Indianapolis, IN 46240 317.844.6777 Landscape Vive Exterior Design 15325 Herriman Blvd. Noblesville, IN 46060 317.773.9933 KEY PLAN