HomeMy WebLinkAboutDI ) I ) I q 01 <I ­1I GI C I E DI CI 11.2 1 1 2 1 3 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 1 16 1 17 1 18 1 19 1 20 1 21 1 22 1 23 1 24 LIGHT FIXTURE SCHEDULE FIXTURE MANUFACTURER CATALOG DESCRIPTION LAMP NUMBER/ DESCRIPTION VOLTAGE REMARKS TYPE INDICATES 2 PHASE, 1 NEUTRAL, AND 1 GROUND CONDUCTOR NUMBER LINE THRU DEVICE INDICATES ABOVE COUNTER O CEILING SMOKE DETECTOR ,-a-� A WILLIAMS SERIES 50G 2x4' STATIC GRID TROFFER. MITERED AND FULLY GASKETED DOOR FRAME WITH FULLY ENCLOSED SPRING - LOADED CAM LATCHES. FOUR (4) 32 WATT T8 2771120 1,2 SIMPLEX RECEPTACLE H .125" THICK, J12 PATTERN ACRYLIC LENS. ALL PARTS PAINTED WHITE AFTER FABRICATION. ELECTRONIC BALLAST FLUORESCENT OVERHEAD ELECTRICAL C5-50R B WILLIAMS SERIES 50G 2'x4' STATIC GRID TROFFER. MITERED AND FULLY GASKETED DOOR FRAME WITH FULLY ENCLOSED SPRING - LOADED CAM LATCHES. THREE (3) 32 WATTT8 2771120 1,2 JUNCTION BOX ® 75 STROBE LIGHT WITH CANDELA RATING. 15cd RATING UNLESS OTHERWISE NOTED ON PLANS. .125" THICK, 112 PATTERN ACRYLIC LENS. ALL PARTS PAINTED WHITE AFTER FABRICATION. ELECTRONIC BALLAST. FLUORESCENT Q TELEPHONE OUTLET (SINGLE -GANG BOX WITH (1) 314' CONDUIT TO ABOVE ACCESSIBLE CEILING) B1 WILLIAMS SERIES 5OG 2'x2' STATIC GRID TROFFER. MITERED AND FULLY GASKETED DOOR FRAME WITH FULLY ENCLOSED SPRING - LOADED CAM LATCHES. THREE (3) 17 WATT T8 2771120 1 ® RELAY - - -- UGC - -- .125" THICK, 112 PATTERN ACRYLIC LENS. ALL PARTS PAINTED WHITE AFTER FABRICATION. ELECTRONIC BALLAST FLUORESCENT DATA OUTLET (DOUBLE -GANG BOX WITH (2) 314' CONDUITS TO ABOVE ACCESSIBLE CEILING) FRCP C WILL14MS SERIES 50G 2'x4' STATIC GRID TROFFER. MITERED AND FULLY GASKETED DOOR FRAME WITH FULLY ENCLOSED SPRING - LOADED CAM LATCHES. TWO (2) 32 WATTT8 2771120 1 LIGHT FIXTURE FED FROM CRITICAL BRANCH OF EES © .125" THICK, 112 PATTERN ACRYLIC LENS. ALL PARTS PAINTED WHITE AFTER FABRICATION. ELECTRONIC BALLAST. FLUORESCENT FIRE ALARM EXTENDER CABINET C1 WILLIAMS SERIES 50G 2'x2' STATIC GRID TROFFER. MITERED AND FULLY GASKETED DOOR FRAME WITH FULLY ENCLOSED SPRING - LOADED CAM LATCHES. TWO (2) 17 WATT T8 2771120 1 TC TIMECLOCK - REFER TO PLANS FOR ASSOCIATED REMOTE CONTROL SWITCH ■ IS .125" THICK, 112 PATTERN ACRYLIC LENS. ALL PARTS PAINTED WHITE AFTER FABRICATION. ELECTRONIC BALLAST. FLUORESCENT SURFACE /RECESSED LIGHT FIXTURE ❑-I D WILLIAMS DI SERIES 2'x4' RECESSED DIRECT /INDIRECT FIXTURE WITH WHITE PERFORATED ROUND BOTTOM DIFFUSER. TEXTURED, NON- GLARE, WHITE THREE (3) 32 WATT T8 2771120 1 CB CODE BLUE STATION 1 POWDER COATED REFLECTOR. ALL PARTS PAINTED AFTER FABRICATION. GRID MOUNTING. WHITE FINISH. ELECTRONIC BALLAST. FLUORESCENT DISCONNECT SWITCH. SIZE, NUMBER OF POLES, AND FUSING AS INDICATED ON PLANS. SS D1 WILL14MS Dl SERIES 2'x2' RECESSED DIRECT /INDIRECT FIXTURE WITH WHITE PERFORATED ROUND BOTTOM DIFFUSER. TEXTURED, NON- GLARE, WHITE THREE (3) 17 WATT T8 2771120 1 $3 LIGHT SWITCH - 3 -WAY ® POWDER COATED REFLECTOR. ALL PARTS PAINTED AFTER FABRICATION. GRID MOUNTING. WHITE FINISH. ELECTRONIC BALLAST. FLUORESCENT NURSE CALL DOME LIGHT $4 E DUAL -LITE PG SERIES EXTERIOR WALL - MOUNTED EMERGENCY LIGHTING FIXTURE. DIE -CAST HOUSING WITH ALUMINUM REFLECTOR AND ACRYLIC LENS. TWO (2) 72 WATT 2771120 1 = RECESSED PANELBOARD NCM FURNISH WITH OPTIONAL BATTERY HEATER. UL- LISTED WET LOCATION. DARK BRONZE FINISH. INCANDESCENT CEILING - MOUNTED MOTION SWITCH F WILLIAMS SERIES 77 4' -0' LONG STRIP FIXTURE. CHAIN MOUNT FROM CEILING AT 8 -6' A.F.F. ALL PARTS PAINTED WHITE AFTER FABRICATION. TWO (2) 32 WATT T8 2771120 1,2,3,4 04 FIXED CAMERA EM NL ELECTRONIC BALLAST. WHERE FIXTURE IS LABELED "ER" FURNISH WITH BODINE B50 EMERGENCY BATTERY PACK FOR FLUORESCENT RELOCATED FIXTURE OR DEVICE EXISTING FIXTURE OR DEVICE CCTV VIDEO MONITOR JACK CM TP COORDINATE EXACT MOUNTING HEIGHT OF DEVICE TAMPER -PROOF DEVICE EMERGENCY OPERATION OF LAMPS. WEATHER PROOF GROUND FAULT INTERRUPT INDICATES CONNECT TO EXISTING Ft WILL14MS SERIES 77 2' -0' LOVG STRIP FIXTURE. CHAIN MOUNT FROM CEILING AT 8 -6' A.F.F. ALL PARTS PAINTED WHITE AFTER FABRICATION. TWO (2) 17 WATT T8 2771120 1,3,4 ELECTRGrvrC BALLAST. FLUORESCENT G WILLIAMS SERIES MDS 2'x4' STATIC FLANGED SURGICAL TROFFER. KSH -34 RF .150' THICK CLEAR PRISMATIC DIRECTIONAL ACRYLIC LENS WITH RADIO SIX (6) 32 WATT T8 2771120 1,2,3 SUPPRESSION GRID. ENCLOSED SPRING - LOADED CAM ACTION LATCHES. STEEL FIXTURE DOOR WITH MITERED CORNERS. ALL FLUORESCENT PARTS PAINTED WHITE AFTER FABRICATION. FURNISH TWO (2) BALLASTS TO SWITCH MIDDLE TWO (2) LAMPS AND REMAINING FOUR (4) LAMPS SEPARATELY. WHERE FIXTURE IS LABELED "EB' EMERGENCY BALLAST IS FOR MIDDLE LAMPS. H WILLIAMS PV60 6" ROUND APERTURE RECESSED OPEN DOWNLIGHT. VERTICAL LAMP POSITION. SELF - FLANGED, SEMI - SPECULAR LOW IRIDESCENT ONE (1) 32 WATT TRIPLE 2771120 1,3 ALUMINUM REFLECTOR. ELECTRONIC BALLAST. TUBE FLUORESCENT K WILLIAMS PVSL60 6.25" ROUND SHOWER LIGHT VERTICAL LAMP POSITION. LEXAN DROP OPAL DIFFUSER WITH NEOPRENE GASKET ONE (1) 32 WATT TRIPLE 2771120 1,3 SELF - FLANGED, SEMI- SPECULAR LOW IRIDESCENT FINISH ALUMINUM REFLECTOR. CLEAN MATTE WHITE LEXAN REFLECTOR TRIM. TUBE FLUORESCENT ELECTRONIC BALLAST. L2 WILL14MS SERIES 1SF 24' LONG LOW - PROFILE UNDER - CABINET FIXTURE ALL PARTS PAINTED WHITE AFTER FABRICATION. FLAT, CLEAR ACRYLIC LENS. ONE (1) 14 WATT T5 120 3 ELECTRONIC BALLAST. FURNISH WITH OPTIONAL ROCKER SWITCH. FLUORESCENT Q INVUE ENTRI SERIES EXTERIOR WALL - MOUNTED FIXTURE. ONE- PIECE, DIE -CAST ALUMINUM HOUSING AND FACEPLATE. SILICONE GASKETING. CLEAR, ONE (1) 100 WATT CERAMIC 2771120 1,3,5 TEMPERED GLASS LENS. FORWARD THROW OPTICS WITH 10% SECONDARY GLOW. FULL CUTOFF PERFORMANCE. HIGH POWER METAL HALIDE FACTOR BALLAST. POWDER COAT FINISH AS DIRECTED BY ARCHITECT. UL LISTED WET LOCATION. T WILLIAMS MHSQ12 12' SQUARE APERTURE RECESSED LENSED DOWNLIGHT. SELF - FLANGED, SEMI- SPECULAR LOW IRIDESCENT FINISH ALUMINUM ONE (1) 150 WATT ED17 2771120 3 REFLECTOR. CLEAR TEMPERED GLASS LENS. ELECTRONIC BALLAST. UL- LISTED WET LOCATION UNDER COVERED CEILING. PULSE START METAL HALIDE CUSTOM FINISH IN ALUMINUM POWDER -COAT PAINT - COORDINATE EXACT COLOR WITH ARCHITECT PRIOR TO ORDERING. U WILL14MS PHSQ12 12" SQUARE APERTURE RECESSED LENSED DOWNLIGHT. SELF - FLANGED, SEMI - SPECULAR LOW IRIDESCENT FINISH ALUMINUM TWO (2) 42 WATT COMPACT 2771120 3 REFLECTOR. CLEAR TEMPERED GLASS LENS, ELECTRONIC BALLAST. UL- LISTED WET LOCATION UNDER COVERED CEILING. FLUORESCENT CUSTOM FINISH IN ALUMINUM POWDER -COAT PAINT - COORDINATE EXACT COLOR WITH ARCHITECT PRIOR TO ORDERING. W HUBBELL VAPORTITE ROUGH LOCATION FIXTURE. FULLY ENCLOSED AND GASKETED. VXFC- 100 -N34 CAST ALUMINUM BODY. VG -15 TEMPERED ONE (1) 150 WATT A21 120 1,3 V- SERIES GLASS GLOBE. FURNISH IN WALL ARM MOUNT CONFIGURATION (VW -1) WITH OPTIONAL CAST ALUMINUM GUARD (VCG -15). NEMA INCANDESCENT 3,4 RATING. X DUAL -LITE SEMPRA SERIES COMPACT, LOW- PROFILE EXIT SIGN. CAST ALUMINUM CONSTRUCTION. FINISH BLACK WITH BRUSHED ALUMINUM FACE. RED FOUR (4) HIGH- OUTPUT LEDS 2771120 3 LETTERS. END, TOP, OR WALL MOUNTED IN SINGLE /DOUBLE FACE CONFIGURATION WITH DIRECTIONAL ARROWS AS INDICATED ON TOTAL POWER CONSUMPTION PLANS. OF 2.6 WATTS REMARKS: 1. WHERE FIXTURE IS LABELED 'EM', CONNECT TO EMERGENCY CIRCUIT. 2. WHERE FIXTURE IS LABELED 'EB", FURNISH WITH BODINE B50 EMERGENCY BATTERY PACK FOR EMERGENCY OPERATION OF LAMPS. J. FURNISH WITH AND INSTALL ALL NECESSARY HARDWARE AND MOUNTING BRACKETS. 4. FURNISH FIXTURE WITH WIRE GUARD. 5. WHERE FIXTURE IS LABELED "EM" PROVIDE AND INSTALL BODINE AK175 ARC - KEEPER' BALLAST OR APPROVED EQUAL FOR FIXTURE. BALLAST TO AfAINTA /N ARC OF LAMP FOR A MINIMUM OF 2 MINUTES DURING AN INTERRUPTION OF POWER. GENERAL NOTES (APPLICABLE TO ALL FIXTURES): 1) ALL FIXTURES UTILIZING LINEAR FLUORESCENT LAMPS SHALL COMPLY WITH NEC 410.130(G) REQUIREMENTS FOR DISCONNECTING MEANS. CONTRACTOR SHALL SUPPLY SAME IF NOT STANDARD ON FIXTURE. 2) ALL ELECTRONIC BALLASTS SHALL BE PROGRAMMED START. CEILING - MOUNTED HORN OR HORN /STROBE --1 4' FINISHCEILING .., ......................................................................................` ���-""°.-............................................. .............._................ CEILING- MOUNTED DETECTOR a 96_ — — — — — — — — — -- _ - - - -- -- i 88 wY - -- - - - - - -- -- DO NOT PLACE ® HORN DETECTOR IN STROBE HORN /STROBE THIS AREA 80' ` — — — — f WALL - MOUNTED DETECTOR 54' -s- — — — — I WALL MOUNTED OPERABLE DEVICES WALL - MOUNTED DEVICE W/ SIDE ACCESSIBILITY - -- -- a ® a ®® 4 PULL STATION u - - - - - - -- - - - - - - - - - ---- ABOVE COUNTER DEVICES. COORDINATE WITH ARCH. ELEVATIONS AND CABINETRY ®® SHOP DRAWINGS. LI__ ° 16 " = -- -- -------- --- - - - - -- POWER /COMMUNICATIONS DEVICES AND CAN OUTLET DEVICES AND SYSTEMS FURNITURE OUTLETS MOUNTING BRACKETS FINISHFLOOR ...................... ..................................... ............................ ........... _........................................... ....................................... .......,................... ................................. ............................... GENERAL NOTES: POWER/COMMUNICATION DEVICES: 1. MOUNTING HEIGHTS SHOWN IN THIS DETAIL ARE TYPICAL OUTLETS SHALL BE LOCATED AT 16' A.F.F. TO THE BOTTOM UNLESS OTHERWISE NOTED ON THE PLANS. OF THE BOX. ABOVE COUNTER DEVICES SHALL BE 2 SEE ARCHITECTURAL ELEVATIONS FOR SPECIAL LOCATED AT 2" ABOVE THE BACKSPLASH OF THE COUNTER CONDITIONS. NOTIFY ARCHITECT IMMEDIATELY OF ANY TO THE BOTTOM OF THE DEVICES. VERIFY WITH CONFLICTS. ARCHITECTURAL DETAILS. J. ALL INSTALLATIONS SHALL COMPLY WITH ADA. WALL-MOUNTED OPERABLE DEVICES: OPERABLE DEVICES SHALL BE LOCATED AT 48' A.F.F. TO LOCATE DEVICE SO THE BOTTOM OF THE DEVICE IS THE TOP OF THE OPERABLE PORTION OF THE DEVICE BETWEEN 80' AND 96' A.F.F. (NFPA) OR 6' BELOW CEILING, WHICHEVER IS LOWER (ADA 2010). WALL - MOUNTED OPERABLE DEVICES INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: AUDIBLE FIRE ALARM NOTIFICATION DEVICES (HORN) LIGHT SWITCHES, DIMMERS, CONTROLS, ETC. LOCATE DEVICE SO THAT THE TOP OF UNIT IS NOT MORE PUSH BUTTONS THAN 90' A.F.F. AND NOT LESS THAN 6' BELOW CEILING NURSE /PATIENT CALL DEVICES (INLUDING THOSE FOR (NFPA) STAFF USE) OTHER CONTROL OR 'CALL' DEVICES FIRE ALARM ACTIVATION DEVICES (PULL S -ARM) LOCATE FRONT- APPROACH DEVICES SO THAT THE HIGHEST OPERABLE PORTION OF THE DEVICE IS NOT MORE THAN 48' A.F.F (ADA 2010) AND NOT LESS THAN 42' A.F.F. (NFPA). MOUNTING HEIGHTS FOR WALL- MOUNTED DEVICES NOT TO SCALE A CLEARANCE TO FRONT OF PANELBOARD L- .....''... -� DEDICATED ELECTRICAL SPACE TO 5 I STRUCTURAL CEILING OR HARD CEILING. / \ S ONLY ELECTRICAL CONDUIT AND WORKING CLEARANCES ZONE CONDUCTORS SHALL BE PERMITTED LUMINAIRES, PIPING, DUCTWORK 1 '` TO PENETRATE THIS AREA. OR OTHER ITEMS SHALL NOT BE INSTALLED IN THE WORKING \ CLEARANCES. \ SURFACE MOUNTED OR RECESSED PANELBOARD z DEDICATED ELECTRICAL SPACE TO I FLOOR. ONLY ELECTRICAL CONDUIT AND CONDUCTORS SHALL BE PERMITTED TO PENETRATE THIS AREA. :. 3 112' HOUSEKEEPING /- PAD FOR MORE THAN (2) CONDUIT PENETRAIONS (SURFACE MOUNTED \ PANELBOARDS ONLY) � I / 30' NEED NOT BE CENTERED ON J % PANEL BUT MUST ENCOMPASS ENTIRE PANEL COORDINATE ALL WORK WITH OTHER TRADES. MAINTAIN ALL OTHER NEC CLEARANCES AND REQUIREMENTS. TYPICAL PANELBOARD INSTALLATION DETAIL NOT TO SCALE R A 10 1 11 1 12 1 13 14 ELECTRICAL SYMBOL LEGEND SOME SYMBOLS AND ABBREVIATIONS ON THIS LEGEND MAY NOT BE USED NOT TO SCALE HOME RUN (2 #12, 1 112 G UNLESS NOTED OTHERWISE) DUPLEX RECEPTACLE MANUAL PULL STATION 15 1 16 INDICATES 2 PHASE, 1 NEUTRAL, AND 1 GROUND CONDUCTOR 1 18 LINE THRU DEVICE INDICATES ABOVE COUNTER O CEILING SMOKE DETECTOR ,-a-� HOME RUN INDICATES SHARED CIRCUIT QUADPLEX RECEPTACLE OD DUCT SMOKE DETECTOR HOME RUN DENOTES 110 CONDUCTORS THROUGHOUT CIRCUIT SIMPLEX RECEPTACLE H HEAT DETECTOR OVERHEAD ELECTRICAL C5-50R SPECIAL RECEPTACLE W/NEMA CONFIG AS NOTED DH DOOR HOLDER OHE - - -- UGE - -- UNDERGROUND ELECTRICAL J O JUNCTION BOX ® 75 STROBE LIGHT WITH CANDELA RATING. 15cd RATING UNLESS OTHERWISE NOTED ON PLANS. TELE -- TELEPHONE CONDUIT Q TELEPHONE OUTLET (SINGLE -GANG BOX WITH (1) 314' CONDUIT TO ABOVE ACCESSIBLE CEILING) 30 COMBINATION HORN /STROBE WITH CANDELA RATING. 15cd RATING UNLESS OTHERWISE NOTED ON PLANS. - - -- UGT - -- UNDERGROUND TELEPHONE CONDUIT 41 LINE THRU DEVICE INDICATES ABOVE COUNTER ® RELAY - - -- UGC - -- UNDERGROUND CABLE TV CONDUIT , DATA OUTLET (DOUBLE -GANG BOX WITH (2) 314' CONDUITS TO ABOVE ACCESSIBLE CEILING) FRCP FIRE ALARM CONTROL PANEL FLUORESCENT LIGHT FIXTURE .1 TELEPHONE /DATA OUTLET (DOUBLE -GANG BOX WITH (2) 314' CONDUITS TO ABOVE ACCESSIBLE CLG.) FAAP FIRE ALARM ANNUNCIATOR PANEL LIGHT FIXTURE FED FROM CRITICAL BRANCH OF EES © TELEVISION OUTLET (SINGLE GANG BOX WITH (1) 314' CONDUIT TO ABOVE ACCESSIBLE CEILING) FAEC FIRE ALARM EXTENDER CABINET LIGHT FIXTURE FED FROM LIFE SAFETY BRANCH RCS -1 REMOTE CONTROL SWITCH AS SCHEDULED ■ WF WATERFLOW SWITCH o FLUORESCENT STRIP FIXTURE TC TIMECLOCK - REFER TO PLANS FOR ASSOCIATED REMOTE CONTROL SWITCH ■ IS TAMPER SWITCH p SURFACE /RECESSED LIGHT FIXTURE ❑-I PUSH BUTTON PC NURSE CALL EMERGENCY PULL CORD I-(] FO WALL - MOUNTED LIGHT FIXTURE i011 MOTOR CB CODE BLUE STATION 1 EXIT LIGHT ❑' DISCONNECT SWITCH. SIZE, NUMBER OF POLES, AND FUSING AS INDICATED ON PLANS. SS NURSE CALL STAFF STATION $ LIGHT SWITCH - SINGLE POLE a COMBINATION DISCONNECT SWITCH / MOTOR STARTER DS NURSE CALL DUTY STATION $3 LIGHT SWITCH - 3 -WAY ® TOGGLE -TYPE THERMAL MOTOR PROTECTION SWITCH DL - NURSE CALL DOME LIGHT $4 LIGHT SWITCH - 4 -WAY SURFACE PANELBOARD ZL - NURSE CALL ZONE LIGHT $M WALL - MOUNTED MOTION SWITCH = RECESSED PANELBOARD NCM NURSE CALL MASTER STATION ® CEILING - MOUNTED MOTION SWITCH DISTRIBUTION PANELBOARD AI MEDICAL GAS ACTUATOR SWITCH SB SWITCHBONK - REFER TO PLANS FOR QUANTITIES /ROWS OF SWITCHES ` SWITCHBOARD. FEEDER /MAIN CIRCUIT BREAKER SECTION AND DISTRIBUTION SECTION. 04 FIXED CAMERA EM NL EMERGENCY FIXTURE /DEVICE NIGHT LIGHT RL EX RELOCATED FIXTURE OR DEVICE EXISTING FIXTURE OR DEVICE CCTV VIDEO MONITOR JACK CM TP COORDINATE EXACT MOUNTING HEIGHT OF DEVICE TAMPER -PROOF DEVICE WP GFI WEATHER PROOF GROUND FAULT INTERRUPT INDICATES CONNECT TO EXISTING OF/OI OF /CI EQUIPMENT FURNISHED AND INSTALLED BY OWNER OWNER - FURNISHED / CONTRACTOR- INSTALLED HUBBELL 20 AMP, 125 VOLT TWISTLOCK DEVICE TO MATCH CEILING RECEPTACLE SJO CORD. (2; AND (1) #1: HOSPITAL GRADE CONNECTOR BODY. HUBBELL INSULGRIP IHBL8319C OR EQUAL (20 AMP, 125 VOLT STRAIGHT BLADE WITH GROUND). 20 AMP, 125 VOLT TWISTLOCK RECEPTACLE FLUSH IN CEILING. TWO (2) WIRE PLUS GROUND. HUBBELL KELLUMS STRAIN RELIEF I -GRIPS HUBBELL KELLUMS STRAIN RELIEF I -GRIPS ' AFF OR DROP CORD DETAIL IR IQ I I AI �0 IL IK I ACCESS DOOR BY MECH. CONTRACTOR FIRE /SMOKE DAMPER BY MECHANICAL CONTRACTOR. DUCT DETECTOR. INSTALL PER POWERED OPEN. MANUFACTURER'S RECOMMENDATIONS. H E i / F D — J TO FIRE ALARM _.._. __ _._ .................... CONTROL PANEL ACT... DUCT G ACTUATOR R 120 VAC REMOTE ANNUNCIATOR/ TEST SWITCH LOCATED AT THE CEILING. FIRE ALARM RELAY •r FIRE /SMOKE DAMPER WIRING DIAGRAM F NOT TO SCALE FAN SHUTDOWN RELAY � E WIRE TO SHUT HE R DOWN UNIT DUCT SMOKE DETECTOR WITH AUXILIARY CONTACTS FOR FAN SHUTDOWN (TYP.) D D D REMOTE ANNUNCIATOR AND TEST SWITCH f LOCATED AT THE A A CEILING. (TYPICAL) SUPPLY AIR ` DUCTWORK Y " TO FIRE ALARM CONTROL PANEL RETURN AIR C DUCTWORK DUCT SMOKE DETECTOR DIAGRAM NOT TO SCALE Carmel Specialty Surgery Center Tenant Improvement Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.37571 f 866.760.3757 ISSUED FOR: Permit 7 May 2012 Site Improvements 23 May 2012 -,101' v' PEARS No. PE10403240 STATE OF NDIAN - -*+ ��� '� F GN �'S '''��irSiiONAL ? Gastinger Walker Harden / Architects 817 Wyandotte Kansas City, MO 64105 816 4218200 p ' 816 421 1262 f designwithinsight.com Electrical / Plumbing PKMR Engineers 8801 Ballentine, Suite 200 Overland Park, KS 66214 913.492.240012437 fax Mechanical Wiegmann Associates, Inc. 750 Fountain Lakes Blvd. St. Charles, MO 63301 314.409.3350 Structural Bob D. Campbell & Co. 4338 Belleview Kansas City, MO 64111 816.531.4144 Civil Cripe Architects + Engineers 3939 Priority Way South Drive, Suite 400 Indianapolis, IN 46240 317.844.6777 Landscape Vive Exterior Design 15325 Herriman Blvd. Noblesville, IN 46060 317.7719933 KEY PLAN Drawn By DET Checked By MDR ELECTRICAL SCHEDULES /DETAILS Project Number: 2012.105 © Copyright 2012 NOT TO SCALE 15 1 16 1 17 1 18 1 19 1 20 1 21 Carmel Specialty Surgery Center Tenant Improvement Meridian Crossing First Floor 11590 N Meridian Street Carmel, IN 46032 923 NE Woods Chapel Road, Suite 550 Lee's Summit, MO v 866.700.37571 f 866.760.3757 ISSUED FOR: Permit 7 May 2012 Site Improvements 23 May 2012 -,101' v' PEARS No. PE10403240 STATE OF NDIAN - -*+ ��� '� F GN �'S '''��irSiiONAL ? Gastinger Walker Harden / Architects 817 Wyandotte Kansas City, MO 64105 816 4218200 p ' 816 421 1262 f designwithinsight.com Electrical / Plumbing PKMR Engineers 8801 Ballentine, Suite 200 Overland Park, KS 66214 913.492.240012437 fax Mechanical Wiegmann Associates, Inc. 750 Fountain Lakes Blvd. St. Charles, MO 63301 314.409.3350 Structural Bob D. Campbell & Co. 4338 Belleview Kansas City, MO 64111 816.531.4144 Civil Cripe Architects + Engineers 3939 Priority Way South Drive, Suite 400 Indianapolis, IN 46240 317.844.6777 Landscape Vive Exterior Design 15325 Herriman Blvd. Noblesville, IN 46060 317.7719933 KEY PLAN Drawn By DET Checked By MDR ELECTRICAL SCHEDULES /DETAILS Project Number: 2012.105 © Copyright 2012