HomeMy WebLinkAboutPt1
N
1 PARAPET FLASHING SCALE 3" = 1' -0"
itii�
1= �
,
i
i
7 OVERFLOW SCUPPER SCALE 3" _
KEYED NOTES SHEET 210
(l 26 GA. G.I. PARAPET CAP, PAINTED FINISH.
�2 15 LB. FELT CONTINUOUS
O3 TAPERED BLOCKING CONTINUOUS
�4 CONTINUOUS 2 X 12 FRT. WOOD
0 CONTINUOUS STUD TRACK
�6 FASTENERS AT APPROX. 8" O.C.
O FASTENERS AT APPROX. 2' -0" O.C.
88 CONTINUOUS CLEAT
�9 26 GA. G.I. COUNTER FLASHING
10 FLEXIBLE VAPOR RETARDER AS INSULATION RETAINER
11 BASE FLASHING
12 TREATED WOOD CANT CONTINUOUS
13 6" X 6" X 16 GA. GALVANIZED ANGLE AT 4' -0" O.C. TYPICAL
WITH PREPUNCHED NAIL HOLES
14 2 X 12 TREATED WOOD.CURB CONTINUOUS
15 COMPRESSIBLE INSULATION, CONTINUOUS
16 SHEATHING
17 2 X 6 TREATED WOOD BLOCKING
18 FASTENERS TO DECK AT APPROX. 2' -0" O.C.
19 BUILT -UP ROOFING
20 ROOF INSULATION BOARDS TAPERED FOR SLOPE TO DRAIN
21 STEEL ROOF DECK, REF. STRUCTURAL DWGS.
22 SPRAY -ON FIREPROOFING
2 ROOF EXPANSION JOINT SCALE 3" = 3 EQUIPMENT BASE SCALE 3" =1' -0"
E;U IP M
TYPICAL
g EQUIPMENT bASE SCALE 3" = 1'
is
_ - IN
1. MINIMUM 30" SQUARE 4 LB. LEAD OR 16 OZ. SOFT COPPER FL ;4NG SET
ON FINISHED ROOF FELTS IN MASTIC. PRIME TOP SURFACE BEFORE
STRIPPING. t-
2. MEMBRANE PLIES, METAL FLASHING AND FLASH -IN PLIES EXTEND UNDER
CLAMPING RING.
3. EXTEND STRIPPING FELTS 4" AND 6" BEYOND EDGE OF FLASHING SHEET,
BUT NOT BEYOND EDGE OF SUMP.
4. TAPER INSULATION 24" DOWN TO DRAIN FROM 3" THICK TO 2" THICK.
5. REF. PLUMBING DWGS. FOR ROOF DRAIN. MFR. MODEL, SIZE AND PIPING
REQUIREMENTS.
g ROOF DRAIN NO SCALE
2'3 CONTINUOUS STEEL ANGLE, REF. STRUCTURAL DWGS. 45 RAIN COLLAR
24 ELASTOMERIC BELLOWS EXPANSION JOINT COVER WITH METAL FLANGES 46 FLUE
25 CHAMFER TOP EDGE OF CURB 47 VENTILATING,ROOF THIMBLE
26 ROOF SURFACE ELEVATION VARIES 48 STEEL STIFFENER PL. 1/4 X 3 X O' -3 ", WELD TO PIPE AND BASE PLATE
271 ROOF TOP UNIT, REF. MECH. DWGS. 49 STEEL BASE PLATE 1/4" X 3' -0" X 3' -0"
28 GASKET /SEAL STRIP CONTINUOUS 50 CENTERLINE OF STEEL JOIST, REF. STRUCTURAL DWGS,
1 30 26 GA. G.I. COUNTER FLASHING
51 COPE END TO BEAR ON STEEL JOIST.
FASTENERS AT APPROX. 1' -0" O.C. 52 WELD ALL AROUND
a2 INCH WOOD NAILER 53 GALV. ANGLE 1 X 1 X 18 GA. RIVET AND SOLDER TO SCUPPER
INSULATED MANUFACTURED STEEL CURB, REF. MECH. DWGS. 54 22 GA. G.I. SCUPPER
33 CONTINUOUS 2 X 8 TREATED WOOD BLOCKING 55 G.I. CLOSURE FLANGE, SOLDER AND SEAL TO SCUPPER
34 CONTINUOUS STEEL PL., REF. STRUCTURAL DWGS. 56 SEAL PERIMETER OF SCUPPER PENETRATION
35 2 -112" INSULATION AT INTERIOR OF CURBED AREA. 57 ANGLE FLANGE 1 -1/2 X 1 -1/2 CONT. AT PERIMETER OF
36 3 STANDARD PIPE SCUPPER
37 SEALANT 58 22 GA. G.Z. CAP @ PERIMETER 01' CURB
38 DFAW BAND 59 STRAINER
39 GALVANIZED STEEL UMBRELLA 6o CLAMPING RING
40 STEEL BASE PL. WELD TO STRUCTURAL MEMBER, REF- STRUCT. DWG. S METAL FLASHING
0,41 2 STD PIPE, GALVANIZED 62 DECK CLAMP
42 WEATHERTIGHT CAPPED END 63 STRIPPING FELTS
43 STEEL BASE, REF. 121210 64 TAPER INSULATION FROM 3" THICK AT 24" DOWN TO DRAIN
44 STEEL ANGLE 5 X 3 -1/2 X 1/4 65 STEEL ROOF DECK, REF. STRUCTURAL DWGS.
66 PAINTED FINISH
4 FLUE FLASHING - SCALE 311 =
10
M
z
5 COLUMN FLASHING SCALE 3" = l' -0"
S7
>-TT F � D�E7�
(j1 CONDENSER FRAME NO SCALE
NOTE:
F,F-F- ELEG . FOR.
N TAN NA 'AqN n
Glrf�MpIN(ro t2evIGs
pli
.L
6 ANTENNA FLASHING SCALE 3" = —0"
12 ANTENNA BASE
NO SCALE
UJ4c
(a
W
Q F
Z
a
o
z
a
J
cc
W
cc
Z
O a
W
Lu
(19
W
F�
Q V
a
U
S
Eli
ae
lT:a _
�I�
SITE SAFETY IS THE
CONTRACTOR'S RESPONSIBIUTY
REFER TO THE SPECIFICATIONS
SHEET TITLE
ROOF DETAILS
n
REVISION NUMBER, DATE i CONTENT
DATE DRAWN NOV 1s 1911
CHECKED e" R BROWNLOW
DRAMA BY R BROWNLOW
PROJECT NO. 491280
CAD FILENAME
SHEET NO.
210