1 -S1 GENERAL NOTES - STRUCTURAL STEEL
SCALE: NONE
I. STEEL ROOF DECK SHALL BE 1 1/2" STANDARD WIDE RIB DECK (WR22), GALVANIZED
ACCORDANCE WITH
22 GAGE CONFORMING TO THE STEEL DECK INSTITUTE AND FACTORY MUTUAL STANDARDS.
DESIGNATION
(TWO OR MORE SPAN LOADING CONDITIONS). TYPICAL ALL ROOF AREAS UNLESS
)MAX)
OTHERWISE NOTED.
2. STEEL FLOOR DECK SHALL BE 9/16" DEEP GALVANIZED RIBBED STEEL DECKING, 26
3/4 "0 BOLTS
GAGE CONFORMING TO THE STEEL DECK INSTITUTE AND FACTORY MUTUAL STANDARDS
SPI
(TWO OR MORE SPAN LOADING CONDITIONS). TYPICAL ALL FLOOR AREAS UNLESS
2
OTHERWISE NOTED.
W6
3. THE STEEL FLOOR DECK IS THE FORM FOR A 2 1/2" CONCRETE DECK WITH 6x6- W1.4xW1.4
PSF
WELDED WIRE FABRIC, PLACED I" BELOW THE TOP SURFACE, UNLESS OTHERWISE NOTED,
12 EA
4. STEEL JOISTS AND JOIST GIRDERS SHALL CONFORM TO THE STEEL JOIST INSTITUTE
W8 a WIO
SPECIFICATIONS.
- NAILABLE
5. ALL SLOPED ROOF JOIST BEARINGS TO BE 5" DEEP UNLESS OTHERWISE NOTED.
PSF
ALL FLOOR JOIST BEARINGS TO BE 2 112" DEEP UNLESS OTHERWISE NOTED.
28
6. CAMBER ALL JOISTS IN ACCORDANCE WITH S.J.I. SPECIFICATIONS.
TYP
7. EXTEND ALL BOTTOM CHORDS OF JOISTS TO COLUMNS. RE: TYPICAL JOIST CONNECTIONS.
2
8. ALL JOIST EXTENDED ENDS SHALL BE DESIGNED TO CARRY THE ALLOWABLE UNIFORM
JOISTS
LOAD FOR THAT JOIST, UNLESS OTHERWISE NOTED.
PSF
9. FURNISH BRIDGING BETWEEN JOISTS IN ACCORDANCE WITH THE STEEL JOIST INSTITUTE
TOTAL DEAD
SPECIFICATIONS UNLESS OTHERWISE NOTED. ATTACH BRIDGING TO END MASONRY
10
WALLS.
CEILING AND LIGHTS
10. STRUCTURAL STEEL SHALL BE AS FOLLOWS EXCEPT AS OTHERWISE NOTED:
PSF
STRUCTURAL SHAPES - ASTM A36 IFy = 36KS1)
JOISTS
STRUCTURAL PIPE - ASTM A501 (Fy = 36KS1) OR
5
ASTM A53, TYPE E OR S, GRADE B Fy = 36KSII
MECHANICAL /ELECTRICAL
II. FIELD CONNECTIONS SHALL BE BOLTED WITH 3/4 "0, ASTM A325 BOLTS EXCEPT AS
2
OTHERWISE NOTED AND WHERE WELDING IS INDICATED ON THE DRAWINGS AND IN THE
CEILING AND
SPECIFICATIONS.
2
12. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE
TOTAL DEAD LOAD
WITH THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION'S "CODE OF STANDARD PRACTICE
PSF
FOR STEEL BUILDINGS AND BRIDGES" AND THE SPECIFICATIONS.
MECHANICAL
13. FABRICATE AND ERECT ALL STRUCTURAL STEEL WITH RESIDUAL MILL CAMBER UPWARDS.
3
14. ALL MASONRY WALLS SHALL BE ANCHORED TO STEEL COLUMNS WITH FLEXIBLE TIES.
LIVE LOADS
RE: SPECIFICATIONS
15. W12x16 INDICATES LEFT END OF BEAM FRAMES INTO THE SIDE OF
TOTAL DEAD
0
(I10' -8 1/2 "I THE COLUMN. INDICATES THAT THE W12x16 BEAM IS LEVEL
20
WITH THE TOP FLANGE AT ELEVATION 110' -8 1/2 ". INDICATES
CLASSROOM /RESTROOM
THAT THE RIGHT END OF THE BEAM EXTENDS OVER THE
PSF
/i TOP OF THE COLUMN.
o.
�O
SNOW LOAD
��
20
W12x16 INDICATES THAT THE W12x16 BEAM IS SLOPED WITH THE TOP
MECHANICAL MEZZANINE
0 /ice (SLOPED) ❑ OF ITS FLANGE AT ELEVATION 110' -0" AND ELEVATION
",
PSF
p 110' -10 112 RESPECTIVELY, AT THE CENTERLINE OF THE TWO
�o COLUMNS.
OFFICE
50
PSF
16. ALL STRUCTURAL ELEVATIONS ARE BASED ON THE TOP SURFACE OF THE FINISHED
FLOOR AT THE GROUND FLOOR BEING EL. 100' -0 ".
17. ALL ROOF JOISTS SHALL BE DESIGNED AND BRACED FOR 10 PSF NET UPLIFT.
STORAGE
18. SPECIAL JOIST DESIGNS:
PSF
TOP CHORD LOADING 280 POUNDS PER FOOT PLUS
A. 32LH SPI: 2 BOTTOM CHORD LOADS AT 500 LBS VERT AND 500 LBS HORIZ
3
B. 32LH SP3: 3 BOTTOM CHORD LOADS AT 500 LBS VERT AND 500 LBS HORIZ
CORRIDOR
C. 32LH SP3: I BOTTOM CHORD LOADS AT 500 LBS VERT AND 500 LBS HORIZ
PSF
LOCATION OF BOTTOM CHORD LOADS AS SHOWN ON ROOF PLAN. JOIST SUPPLIER
FURNISH ADDITIONAL BRIDGING OR BRACING TO TRANSMIT HORIZONTAL LOADS TO
MASONRY WALL.
1 -S1 GENERAL NOTES - STRUCTURAL STEEL
SCALE: NONE
51
531466
3 -S1 DESIGN DATA
SCALE: NONE
L3 1/2x3 I/2xl/4 1/2" CLR
(TYP) I MAX
4 TOTAL
12 EA SIDE) 1
N I/4 TYP
J
p
M 3/4 "0 BOLTS
o (TYP)
z
STL BM Z STL BM
STL BM OF
CL SPLICE LARGER SIZE
= = = = = =
ELEVATION
DESIGNED IN
ACCORDANCE WITH
THE INDIANA BUILDING CODE - 1988.
DESIGNATION
'N' (NO BOLTS)
)MAX)
ROOF LOADS
3/4 "0 BOLTS
FLOOR AND MECHANICAL MEZZANINE
SPI
(TYPI
2
SHINGLES
W6
3
PSF
DEAD LOAD:
12 EA
SIDE)
W8 a WIO
INSULATION
- NAILABLE
5
PSF
2 1/2" CONC ON 9/16 DECK
28
PSF
TYP
1 112 ", 22 GA., ROOF DECK
2
PSF
JOISTS
5
PSF
10
TOTAL DEAD
LOAD ON DECK
10
PSF
CEILING AND LIGHTS
2
PSF
SIDE)
JOISTS
SP7
5
PSF
MECHANICAL /ELECTRICAL
3
PSF
SP8
CEILING AND
LIGHTS
2
PSF
TOTAL DEAD LOAD
38
PSF
MECHANICAL
/ELECTRICAL
3
PSF
LIVE LOADS
TOTAL DEAD
LOAD ON JOISTS
20
PSF
CLASSROOM /RESTROOM
40
PSF
SNOW LOAD
(BASIC)
20
PSF
MECHANICAL MEZZANINE
150
PSF
4
OFFICE
50
PSF
STORAGE
125
PSF
CORRIDOR
100
PSF
PARTITIONS (STUD AND GYP BOARD)
25
PSF
WIND LOAD
80
MPH
SEISMIC ZONE I
51
531466
3 -S1 DESIGN DATA
SCALE: NONE
L3 1/2x3 I/2xl/4 1/2" CLR
(TYP) I MAX
4 TOTAL
12 EA SIDE) 1
N I/4 TYP
J
p
M 3/4 "0 BOLTS
o (TYP)
z
STL BM Z STL BM
STL BM OF
CL SPLICE LARGER SIZE
= = = = = =
ELEVATION
4 -S1 TYPICAL BEAM SPLICE
SCALE: NONE
COPYRIGHT 1990 BY FANNING /HOWEY ASSOCIATES, INC.
B
I. ALL CONCRETE MASONRY SHALL BE ASTM C90 HOLLOW LOAD BEARING (HLI WITH
F'm = 1500 PSI (ON GROSS SECTIONI.
2. ALL MORTAR AND GROUT SHALL CONFORM TO ASTM C270 AND C476 WITH F'c = 2500
PSI AT 28 DAYS (FOR REINFORCED AND GROUTED CONCRETE MASONRY).
3. ALL REINFORCING SHALL BE Fy = 60,000 PSI.
4. FOR VERTICAL CMU CORES REINFORCED WITH ONE BAR, CENTER BAR IN WALL.
5. ALL VERTICAL REINFORCING STEEL IN MASONRY WALLS SHALL BE ALIGNED AND HELD
IN POSITION BY CAGING DEVICES AT 48" C TO C VERTICALLY. (RE: 3 -SMI)
6. THE MINIMUM LENGTH OF LAP FOR VERTICAL REINFORCING IN MASONRY WALLS UNLESS
OTHERWISE NOTED SHALL BE AS FOLLOWS:
BAR NO LAP
#4 14"
#5 18"
#6 24"
7. HORIZONTAL JOINT REINFORCING IN EXTERIOR WALLS SHALL BE HEAVY DUTY (3/16"
LONGITUDINAL RODS AND 9 GA DIAGONAL CROSS RODS) TRUSS TYPE.
HORIZONTAL JOINT REINFORCING IN INTERIOR WALLS SHALL BE STANDARD (9 GA
LONGITUDINAL RODS AND 9 GA DIAGONAL CROSS RODS) TRUSS TYPE.
HORIZONTAL JOINT REINFORCING SHALL BE INSTALLED AT 16 INCH VERTICAL SPACING
UNLESS OTHERWISE NOTED OR AT 8 INCH SPACING AT THE FOLLOWING LOCATIONS:
A. TWO BED JOINTS ABOVE AND BELOW ALL OPENINGS.
B. IN PARAPETS ABOVE THE ROOF LINE.
C. IN ALL MASONRY WALLS BELOW FINISH GRADE.
8. ALL BOND BEAMS SHALL BE CONTINUOUS AND SHALL BE FILLED WITH CONCRETE AND
REINFORCED WITH 245 BARS CONTINUOUSLY UNLESS OTHERWISE NOTED. PROVIDE
DOWELS AT CORNERS TO MAINTAIN CONTINUOUS REINFORCING.
9. GROUT SHALL BE PLACED IN THE VERTICAL CORES OF THE MASONRY UNITS UTILIZING
THE HIGH LIFT GROUTING METHOD SET FORTH IN ACI 531.1 -79 (REVISED 1981) AND ITS
COMMENTARY ACI 531R -79.
A. GROUT SHALL COMPLY WITH ASTM C476. (MORTAR OR CONCRETE SHALL
NOT BE USED TO FILL CMU CORES.) RE: SPECIFICATION SECTION 04125
B. CLEANING HOLES SHALL BE PROVIDED AT THE BOTTOM OF ALL CORES
CONTAINING REINFORCING AND ALL OTHER CORES TO BE GROUTED. CLEANING
HOLES SHALL BE LOCATED ON THE CAVITY FACE OF ALL MASONRY IN
CAVITY WALL CONSTRUCTION. ALL MORTAR DROPPINGS AND OTHER DEBRIS
SHALL BE REMOVED FROM THE CORES PRIOR TO THE START OF THE
GROUTING OPERATION. CLEANING HOLES SHALL BE COVERED JUST PRIOR
TO THE BEGINNING OF THE GROUTING OPERATION.
C. THE MAXIMUM HEIGHT OF A GROUT POUR SHALL BE 24 FEET.
D. GROUT POURS SHALL BE MADE IN LIFTS NOT EXCEEDING 4 FEET IN HEIGHT.
ALLOW 60 MINUTES TO ELAPSE BETWEEN SUCCESSIVE LIFTS.
E. STOP GROUT POURS 1 1/2 INCHES BELOW THE UPPERMOST PORTION OF THE
CAVITY BEING FILLED TO PROVIDE A KEY FOR THE NEXT LIFT OR POUR.
F. CONSOLIDATE GROUT BY PUDDLING OR VIBRATING EACH LIFT PRIOR TO LOSS
OF PLASTICITY.
G. ALL REINFORCING STEEL SHALL BE INSPECTED IN PLACE BEFORE GROUTING
AND THERE SHALL BE CONTINUOUS INSPECTION DURING THE GROUTING OPERATION.
10. IN EXTERIOR WALLS PLACE ONE REINFORCING BAR (SAME SIZE AS IN ADJACENT WALL)
IN GROUTED CORE EXTENDING 4 FEET ABOVE AND BELOW THE OPENING FOR ALL
WINDOW AND DOOR OPENINGS UP TO 8 FEET WIDE. FOR OPENINGS 8 FEET TO 16 FEET
WIDE PLACE TWO REINFORCING BARS IN TWO GROUTED CORES EACH SIDE OF OPENING.
II. GROUT CORES 2 COURSES BELOW ALL LINTEL AND BEAM BEARINGS. (UON)
12. MASONRY WALLS SHOWN ON ARCHITECTURAL DRAWINGS BUT NOT ON STRUCTURAL
MASONRY PLAN SHALL HAVE HORIZONTAL JOINT REINFORCING AS REQUIRED BY SECTION
04200 OF THE SPECIFICATIONS.
13. ALL MASONRY WALLS (INTERIOR AND EXTERIOR) SHALL BE ANCHORED TO STEEL COLUMNS
AND BEAMS WHICH DIRECTLY ABUT THE ENDS OR SIDES OF THE WALL. MASONRY
WALLS SHALL ALSO BE ANCHORED TO STEEL LINTELS. (RE: SECTION 04200 OF THE
SPECIFICATIONS).
2 -S1 GENERAL NOTES - MASONRY
SCALE: NONE
A. CONTINUOUS BEAM
COLUMN
STL BM
I12" BRG STIFFENER
(ONE EA SIDE OF
WEB) TYP 3/4" THK
CAP R (TYP)
3/4 "0 BOLT
(4 TOTAL) -
STL COL
3/16
3"
TY
MIN
C. SIMPLE BEAM (MID COLUMN)
3 I 2" IN
1/2" MAX
3/4 "0 BOLTS
(TYPI * -\
STL 1,
BM
TYP
3/16
3/8" FL' THRU
COLUMN * * -
STL
BM
STL COL
B. SIMPLE BEAM (TOP COLUMN)
L3 1/2x3 1/2x1/4
SPLICE
TABLE
FOR BEAM
SIZES
DESIGNATION
'N' (NO BOLTS)
)MAX)
3/4 "0 BOLTS
SPI
(TYPI
2
(ONE EA SIDE)
W6
SP2
4
12 EA
SIDE)
W8 a WIO
SP3
6
(3 EA
SIDE)
W12 a W14
SP4
TYP
8
(4 EA
SIDE)
W16
SP5
10
15 EA
SIDE)
W18
SP6
OF
12
16 EA
SIDE)
W21
SP7
14
(7 EA
SIDE)
W24
SP8
MIN
16
(8 EA
SIDE)
W27
STL COL
4 -S1 TYPICAL BEAM SPLICE
SCALE: NONE
COPYRIGHT 1990 BY FANNING /HOWEY ASSOCIATES, INC.
B
I. ALL CONCRETE MASONRY SHALL BE ASTM C90 HOLLOW LOAD BEARING (HLI WITH
F'm = 1500 PSI (ON GROSS SECTIONI.
2. ALL MORTAR AND GROUT SHALL CONFORM TO ASTM C270 AND C476 WITH F'c = 2500
PSI AT 28 DAYS (FOR REINFORCED AND GROUTED CONCRETE MASONRY).
3. ALL REINFORCING SHALL BE Fy = 60,000 PSI.
4. FOR VERTICAL CMU CORES REINFORCED WITH ONE BAR, CENTER BAR IN WALL.
5. ALL VERTICAL REINFORCING STEEL IN MASONRY WALLS SHALL BE ALIGNED AND HELD
IN POSITION BY CAGING DEVICES AT 48" C TO C VERTICALLY. (RE: 3 -SMI)
6. THE MINIMUM LENGTH OF LAP FOR VERTICAL REINFORCING IN MASONRY WALLS UNLESS
OTHERWISE NOTED SHALL BE AS FOLLOWS:
BAR NO LAP
#4 14"
#5 18"
#6 24"
7. HORIZONTAL JOINT REINFORCING IN EXTERIOR WALLS SHALL BE HEAVY DUTY (3/16"
LONGITUDINAL RODS AND 9 GA DIAGONAL CROSS RODS) TRUSS TYPE.
HORIZONTAL JOINT REINFORCING IN INTERIOR WALLS SHALL BE STANDARD (9 GA
LONGITUDINAL RODS AND 9 GA DIAGONAL CROSS RODS) TRUSS TYPE.
HORIZONTAL JOINT REINFORCING SHALL BE INSTALLED AT 16 INCH VERTICAL SPACING
UNLESS OTHERWISE NOTED OR AT 8 INCH SPACING AT THE FOLLOWING LOCATIONS:
A. TWO BED JOINTS ABOVE AND BELOW ALL OPENINGS.
B. IN PARAPETS ABOVE THE ROOF LINE.
C. IN ALL MASONRY WALLS BELOW FINISH GRADE.
8. ALL BOND BEAMS SHALL BE CONTINUOUS AND SHALL BE FILLED WITH CONCRETE AND
REINFORCED WITH 245 BARS CONTINUOUSLY UNLESS OTHERWISE NOTED. PROVIDE
DOWELS AT CORNERS TO MAINTAIN CONTINUOUS REINFORCING.
9. GROUT SHALL BE PLACED IN THE VERTICAL CORES OF THE MASONRY UNITS UTILIZING
THE HIGH LIFT GROUTING METHOD SET FORTH IN ACI 531.1 -79 (REVISED 1981) AND ITS
COMMENTARY ACI 531R -79.
A. GROUT SHALL COMPLY WITH ASTM C476. (MORTAR OR CONCRETE SHALL
NOT BE USED TO FILL CMU CORES.) RE: SPECIFICATION SECTION 04125
B. CLEANING HOLES SHALL BE PROVIDED AT THE BOTTOM OF ALL CORES
CONTAINING REINFORCING AND ALL OTHER CORES TO BE GROUTED. CLEANING
HOLES SHALL BE LOCATED ON THE CAVITY FACE OF ALL MASONRY IN
CAVITY WALL CONSTRUCTION. ALL MORTAR DROPPINGS AND OTHER DEBRIS
SHALL BE REMOVED FROM THE CORES PRIOR TO THE START OF THE
GROUTING OPERATION. CLEANING HOLES SHALL BE COVERED JUST PRIOR
TO THE BEGINNING OF THE GROUTING OPERATION.
C. THE MAXIMUM HEIGHT OF A GROUT POUR SHALL BE 24 FEET.
D. GROUT POURS SHALL BE MADE IN LIFTS NOT EXCEEDING 4 FEET IN HEIGHT.
ALLOW 60 MINUTES TO ELAPSE BETWEEN SUCCESSIVE LIFTS.
E. STOP GROUT POURS 1 1/2 INCHES BELOW THE UPPERMOST PORTION OF THE
CAVITY BEING FILLED TO PROVIDE A KEY FOR THE NEXT LIFT OR POUR.
F. CONSOLIDATE GROUT BY PUDDLING OR VIBRATING EACH LIFT PRIOR TO LOSS
OF PLASTICITY.
G. ALL REINFORCING STEEL SHALL BE INSPECTED IN PLACE BEFORE GROUTING
AND THERE SHALL BE CONTINUOUS INSPECTION DURING THE GROUTING OPERATION.
10. IN EXTERIOR WALLS PLACE ONE REINFORCING BAR (SAME SIZE AS IN ADJACENT WALL)
IN GROUTED CORE EXTENDING 4 FEET ABOVE AND BELOW THE OPENING FOR ALL
WINDOW AND DOOR OPENINGS UP TO 8 FEET WIDE. FOR OPENINGS 8 FEET TO 16 FEET
WIDE PLACE TWO REINFORCING BARS IN TWO GROUTED CORES EACH SIDE OF OPENING.
II. GROUT CORES 2 COURSES BELOW ALL LINTEL AND BEAM BEARINGS. (UON)
12. MASONRY WALLS SHOWN ON ARCHITECTURAL DRAWINGS BUT NOT ON STRUCTURAL
MASONRY PLAN SHALL HAVE HORIZONTAL JOINT REINFORCING AS REQUIRED BY SECTION
04200 OF THE SPECIFICATIONS.
13. ALL MASONRY WALLS (INTERIOR AND EXTERIOR) SHALL BE ANCHORED TO STEEL COLUMNS
AND BEAMS WHICH DIRECTLY ABUT THE ENDS OR SIDES OF THE WALL. MASONRY
WALLS SHALL ALSO BE ANCHORED TO STEEL LINTELS. (RE: SECTION 04200 OF THE
SPECIFICATIONS).
2 -S1 GENERAL NOTES - MASONRY
SCALE: NONE
A. CONTINUOUS BEAM
COLUMN
STL BM
I12" BRG STIFFENER
(ONE EA SIDE OF
WEB) TYP 3/4" THK
CAP R (TYP)
3/4 "0 BOLT
(4 TOTAL) -
STL COL
3/16
3"
TY
MIN
C. SIMPLE BEAM (MID COLUMN)
3 I 2" IN
1/2" MAX
3/4 "0 BOLTS
(TYPI * -\
STL 1,
BM
TYP
3/16
3/8" FL' THRU
COLUMN * * -
STL
BM
STL COL
B. SIMPLE BEAM (TOP COLUMN)
L3 1/2x3 1/2x1/4
112"
(4 TOTAL 2 EA SIDE)
)MAX)
3/4 "0 BOLTS
(TYPI
112" BRG STIFFENER
(ONE EA SIDE OF
WEB) TYP
STL BM
!
TYP
STL BM
3/16
3/4 "0 BOLT
STL BM
OF
(4 TOTAL)
LARGER
SIZE
3/4" THK
CAP FE (TYP )
3"
3/16
MIN
TYP
STL COL
NOTES
I. JOIST OMITTED FOR CLARITY.
2. * RE: 4 -SI FOR REQUIRED NUMBER
OF BOLTS.
3. * * WT -SHAPE MAY BE SUBSTITUTED
FOR THRU -PLATE PROVIDED
FLANGE EXTENDS TO WITHIN 1/2"
OF THE EDGES OF COLUMN WITH
FILLET WELD ALL AROUND. WT
MUST HAVE 3/8" WEB.
4. EXTEND DEEPER BEAM OVER TOP OF
ALL COLUMNS AND FRAME OTHER
MEMBERS INTO IT.
5 -S1 STEEL BEAM CONNECTIONS
SCALE: NONE
FAMILY LIFE CENTER
WOODLAND SPRINGS CHRISTIAN CHURCH
EAST 116TH STREET & LAKESHORE DRIVE
CARMEL, INDIANA
V
r�
AL D
E
1' -8" 3' -7" 12 SPACES AT 6' -0" = 72' -0" 3' -9" 4"
12' -2" 9' -3" 9' -10" 9' -10"
;I - - - - - - - � - - -- - -3 - - - - - - - rT U Zi
J I I J J _j
IU U U I� -•� i
U1 i )
1-1 z 9 -11 9 -11 9 \ /
I - 1 \/
IW wl WI WI - - - - - -
F- w w ►- r - -.- _�- - - - - --
Iz zl zl zl (-
w w w w
U U U U
I 1i11ii1ll If
I I I i UP- - - -
- -
-
I i II!llilll I I! I
L1L1111LL 11
EXTEND JOIST TOP CHORD 1' -6 1/4" BEYOND CENTERLINE BEARING I I ! T9 71A FT 9r I II 1
CENTERLINE � MASONRY 6 I I I DN - 1 1 1. 1�k 1 1 1 J 11 I
p JOIST BEARING BEARING
wbxld I rh
JOIST BEARING EL II9' -8 1/4" r I 1119' -8 I /4 ") (119' -8 I /4 ") I y 1 1 L/
T5 1
)STS 1 1
/ "DEP JOIST EARING -SOUTH END I ,
E I
~ 6 E JOIST WARING - NORTH END RAMP UP
EXTEND JOIST TOP CHORD I'- 1/4" BEYOND CENTERLINE BEARING
1/
'
AR
JOIST BEING EL 122-8 4" _
- - - -
-
�t CENTERLINE
U JOIST BEARING i I 1 I 8" CMU w/ 04 AT 96" C TO C
N TOP BOND BEAM EL 121' -4" AND 122' -8"
I,II`1I
_-
ap II C�PJ ROOF DECK 1 I I it I I I I 2x8 ROOF RAFTERS
C w 1�1LJ I I ;. I RV I �I I RV I I I
, , I, I _ -:3 I 1 1 1 I r 1
N 3 mr 1 I 1 1
z 1 I ( 15 - ISK3 JOISTS I 1I1 I 1,
M I I 6 3/4" EE JOIST BEARING - N RTH END �O 01 1 Ir I I I I
{ t I I 2x6 RUNNER AT INTERSECTION
I - -. _ .... . _ _ � { 1 1 � I � I 1 � 1 OF EXISTING ROOF AND NEW ROOF
o , � �T
MASONRY I
OPENING 999
RE: DWG SLI ( I I I I I 1 I TT I I 1 I I ca:
1 I I I 1 I I N
�E (D '
_ _ _. �( _-�_ __ ._. �� I �� I \, 1 I I 2x8 4" C RAFTERS I
JOIST BEARING EL_ 133' -4 1/4" I _ - _ i-- -- -__. - _L _L-- -_ __ J��� ( i - i I - i AT 24" C TO C r� i
CENTERLINE 8" CMU AND I -� , I i I , , , , I / 2x6 STUD WALL AT 16" C TO C I !
JOIST BEARING AT CENTERLINE EXISTING LAMINATED
F°- 1 I I 1 I I ' I 1 I I I I I II 1 ' 1 1 I ARCHES (TYP 4 PLACES)
a? 3 v I( I I I I I I I I I I 1 I I I I I I I
p = I 8" CMU w/ #4 AT 96" C TO C I I
214 TOP BOND BEAM EL 110' -8 ", 121' -4" AND 133' -4" , I , , I 2x8 ROOF RAFTERS
U N
AT 24" C TO C
2x6 RUNNER AT INTERSECTION
EI I 1 I I I 1 _ H JOISTS I I 1 I I II I I I OF EXISTING ROOF AND NEW ROOF -� 1
0 7 32L I 6 -
N
.
°z NOTE. ! 1 I I I I
FILL TOP 8" OF 0 I I/ 2x8 ROOF RAFTERS
a i
= CMU IN END WALLS 1 1 W6x12 M 1 W6x12 11 ! AT 24" C TO C ! I
U WITH GROUT.
'Mp
= o _j �I p1,
►� ; w W6x12 _ W6x12 �j II
0 1 I NOTE:
M a Q 11 I I 1 I i I I I NII I I I , METAL ROOF DECK EXTENDS
OVER WOODEN ROOF FRAMING I I
in w 'N 8 -SLI (TYP) r` I I I (TYP) 8 -SLI M ! RE: ATTACHMENT NOTES BELOW
I I I I 1 I 1 1 I I 1 II I I 1 1 1
°
< z I I W6x12 I I I I I I I W6x12
co
�. I I I I I I i I � � I I•, � �- � �,
o
-I I
1 ml °-' °-'I 1 I ROOF DECK I ?' m m I I 2x8 R00� RAFTERS
AT 24" Q TO C----- - - - - -- I 1 11
�I of of of t o I I I zl zl of I; I I I I I I
I zl zl zl I = I I I I I I I I zl I - J L_ .- - I
- I ..1 I yl- -
I wtII I - I , I , I 1 �I ail w 11 I I / T n n T
II O (L N a
FL I I i I I I l (LI _L'
v� cn in I cn �n in
RV � - /r-
��
*0 JI ( / ��
0 3 MI MI M 1 I I t I I rNi) MI 11 ROOF OPEN FRAML� IRE: 10 -SL11
N= I I I I r\ FOR ROOF V T (TYPI \.
M co ! I I I I \ RE: DWG M3 R SIZE AND LOCATION
II I I I I I 7 1/4" DEEP JOIST BEARING 1 1 I I I II _ \\
�a II UP DIN �� J!� / UP
JOIST BEARING EL 122' -4 I /4" -..�_ _ � _ _ - _ - - ._,.__ ____----- __._.___.__ - - � _ _ - _ I I1 I \ � _•- = - - - - -- � � � ( DN !i 1 ! i
CENTERLINE
JOIST BEARING
�_a
N Z
oLL
v�
a
0 '
U �
z
t0 �
G
�
m
ao
fV
FIRST FLOOR PLAN
JOIST BEARING EL III'4 L
or CENTERLINE
JOIST BEARING
I 1
1 I
1 I
JOIST BEARING EL 108' -8 1/4"
0
ZCENTERLINE
JOIST BEARING
1'-8" I. I. 4' -3"
. - - - -- _... -.- - - - - t- - -
Fr
EXTEND JOIST TOP CHORD 1' -5 3/4" BEYOND CENTERLINE BEARING 1 -1- �r - I \ LLL-LI �I _14 / I C 1t -I- I
EXTEND JOIST TOP CHORD 1' -2 I /8" BEYOND CENTERLINE BEARING - ALTERNATIVE -1- �- "1 1 r -
1 L - 1 -1�,, � I JL� _
10" CMU w/ # 4 AT 48" C TO C VERT I I -!- L --
TOP BOND BEAM EL III' -4" AND 122' -4" Ir L - - L L
II II II II
L - - - - -� I I L - - - - -- I
L - _ - _- - - -_ - i L-- - - - - -J
8" CMU w/ #4 AT 96" C TO C VERT
TOP BOND BEAM EL III' -4" AND 122' -4"
a
H
J 1
N
UP r- /
I i I I I I 1 11 r -1- OJ
14 - 10 JOISTS I I
i I I i ROOF DECK I I I i 11 I - J
I I I I 1 I I I I II
- - - - - - - - - - - -
EXTEND JOIST TOP CHORD 1' -4 1/8" BEYOND CENTERLINE BEARING I II
8" CMU w/ #4 AT 48" C TO C VERT
TOP BOND BEAM EL 108' -8"
it SPACES AT 6' -0" = 66' -0"
PARTIAL FLOOR PLAN (ALTERNATIVE)
3' -9" 11.4"
ATTACHMENT OF METAL DECK TO WOOD RAFTERS
I. USE 14 GAGE (.246" DIAMETER SHANK) x 2" LONG HOT- DIPPED
GALVANIZED OVAL HEADED WOOD SCREWS WITH 5/8" OD
MINIMUM HOT- DIPPED GALVANIZED WASHERS TO CONNECT
STEEL DECK TO WOOD RAFTERS.
2. SPACE CONNECTORS AT 12" C TO C AT INTERMEDIATE SUPPORTS
AND AT 6" C TO C AT END LAPS. RE: SPECIFICATION SECTION
05300 FOR SIDE LAP FASTENERS. -
3. TIGHTEN SCREWS SNUG BUT DO NOT OVER- TIGHTEN SUCH THAT
RAFTERS ARE STRIPPED.
SCALE: 1/8" = 1' -0"
ROOF FRAMING PLAN
DRAWN BY: T.J.H. COMM. NO.: 8971.00 ct
0�
CHECKED BY: G.E.K. DATE: APRIL 2, 1990 z z
�w
U
REVISIONS NO. DATE W w
0�
si Z J
p J
O g
1
2
3
14
5