Loading...
HomeMy WebLinkAboutfI ✓4 3 a 5 531486 TOP OF MASONRY EL. 133' -4" MECH. MEZZ. EL. 121' -9 1/4" FIRST FLOOR EL. III' -1 1/4' GROUND FLOOR EL. 100' -0" TOP OF MASONRY EL. 133' -4" A 0 B O« STRUCTURAL DRAWINGS NEW ROOF SUPPORT MING P .. TOP OF MASONRY EL. 122' -4" TOP OF STONE EL. 112' -0' TOP OF MASO.AIPY -•- EL. 108' -8'" GROUND FLOOR EL. 100' -0" 2 -A3 BUILDING SECTION 10 -A4 7 II W3 W3 W3 a W3 0 W3 W3 �. W3 W3 F . 2 2 E10 00 0 Q W3 F W3 00 [1](D W3 . 2 -A4 9­1 6 15 44 - 15 15 FI �l i 5 -A3 SOUTEAST ELEVATION (ALTERNATIVE) SEE NOTE N0. 13 ik TOP OF MA EL. 133' -4" TOP OF MA EL. 122' -4" TOP OF ST EL. 112' -0' GROUND FL( EL. 100' -0" N n 1 -A3 NORTHWEST ELEVATION 8 -A3 BUILDING SECTION COPYRIGHT BY FANNING /HOWEY ASSOCIATES, INC. Ej y P��DISTER RESID�T � FOiF � D�F �RCH I T K I FAMILY LIFE CENTER WOODLAND SPRINGS CHRISTIAN CHURCH EAST 116TH STREET & LAKESHORE CARMEL, INDIANA DRIVE 4 -A3 SOUTHEAST ELEVATION 7 -A3 SOUTHWEST ELEVATION E ELEVATION NOTES: I. ENTIRE EXISTING ROOF AREAS TO BE REROOFED EXCEPT FOR AREA WHICH WILL BE CONCEALED BY NEW ROOF STRUCTURE. a. RELOCATE ALL EXISTING SHINGLES AND 1/2" WOOD FIBERBOARD. MAINTAIN EXISTING FLASHINGS; REPAIR OR REPLACE AS REQUIRED. b. NEW ROOF TO BE SHINGLES OVER 121 LAYERS 15 lb. FELT OVER 112" ORIENTED STRAND BOARD. SEE SPECIFICATIONS FOR FLASHING AND OTHER REQUIREMENTS. 2. EXISTING WOOD FASCIA, PORCH SUPPORT COLUMNS, PORCH RAILINGS AND GUARDS AND ROOF CUPOLA AND SPIRE ARE TO BE PAINTED. 3. PROVIDE CONTINUOUS EXPANDING FOAM TAPE BETWEEN EXISTING AND NEW STONE VENEER. PROVIDE SEALANT AND BACKER ROD BOTH SIDES OF NEW WALLS ABUTTING EXISTING. 4. PROVIDE CONTINOUS METAL FLASHING AND SEALANT AT NEW ROOF /EXISTING STONE VENEER INTERFACE. 5. NEW 24 GA. METAL STUDS (16" O.C.) W/ 5/8" TYPE 'X' GYPSUM WALL BOARD FROM TOP OF EXISTING STONE VENEER TIGHT TO METAL DECK. 6. REMOVE EXISTING WOOD FASCIA, OUTRIGGERS, FRAMING, AND WOOD DECK AS REQUIRED. 7. PAINT BANDS SHOWN ON INTERIOR WALLS OF BUILDING SECTIONS 2 -A3 AND 8 -A3 ARE CONTINUOUS ON ALL WALLS OF ROOM NO. 100 8. 2'- 0 "x3' -0" METAL FRAME CHIMNEY ENCLOSURE - EIFS OVER I" INSULATION OVER GYPSUM SHEATHING OVER 3 5/8" METAL STUDS. PROVIDE ONE PIECE METAL FLASHING CAP. 9. 1 5/8" METAL STUD AND 5/8" TYPE 'X' GWB VERTICAL CHASE TO ENCLOSE EXHAUST FAN DUCT WORK. SIZE AS REQUIRED. SEE MECH. DWGS. ELEVATION MATERIALS LEGEND 0 STONE VENEER (E - EXISTING) 2O EXTERIOR INSULATION FINISH SYSTEM 3O PAINTED WOOD TRIM 4O SHINGLES 5O MECHANICAL LOUVER (SEE MECH. DWGS.) O PRIMED METAL GUTTER O PRIMED METAL DOWNSPOUT O STEEL PIPE HANDRAIL (SEE SITE DWGS.) 9D 4" STONE SILL 10 PAINTED WOOD COLUMN 11 WOOD FENCE (SEE SITE DWGS) 12 PAINT ALL EXISTING WOOD TRIM 13 NEW SHINGLES ON EXIST. ROOF 14 EXISTING GUTTER & DOWNSPOUT (PAINT) 15 EIFS REVEAL (ALSO BEHIND GUTTER) 3 -A3 NOTES 6 -A3 ADD ALTERNATIVE SCALE: 1/8" = 1' -0" ELEVATIONS, SECTIONS DRAWN BY: VDL COMM. NO.: 8971.00 cr_ CHECKED BY: WEP DATE: APRIL 2, 1990 z zz �w U REVISIONS NO. DATE cn w p LL A3 z J Q } J p J �Ll 1 Fi 3 2 5