HomeMy WebLinkAboutQEXISTING LAKE
k'
4
or UTjLrfiC_.6 urfN U1it,rfY 60 N
AMP lW1&L A110W
MECHANICAL NOTES
M 1 DUCT SIZES NOTED ARE INSIDE CLEAR DIMENSIONS.
�► M2 COORDINATE THE EXACT LOCATION OF ALL CEILING MOUNTED DIFFUSERS
AND GRILLES WITH LIGHT FIXTURES AND CEILING GRID.
M3 EXTERIOR BRACKETS AND CLAMPS SHALL BE GALVANIZED WITH ANY CUT
ENDS OR WELDS COATED WITH COLD GALVANIZING COMPOUND.
M4 INTERIOR BRACKETS, HANGERS AND CLAMPS SHALL BE SHOP PRIMED
UNLESS OF GALVANIZED CONSTRUCTION.
M5 SUSPEND UNIT WITH (4) 3/8" DIA. THREADED HANGER RODS SECURED
TO UNISTRUT OR ANGLE RUNNERS ATTACHED TO BUILDING ROOF PURLINS
tt SPAN MIN. (2) PURLINS.
z.
1 M6 ROUTE TYPE "L" COPPER CONDENSATE DRAIN FROM UNIT TO ADJACENT
-' HR DRAIN. SECURE DRAIN PIPING WITH GALVANIZED PIPE CLAMPS
SECURED TO GALVANIZED UNISTRUT SUPP ORTS. TERMINATE DRAIN
PIPING WITH 90 DEGREE ELL TURNED DOWN 1" ABOVE TOP LIP OF HUB
�. DRAIN IN PLUMBING CHASE.
M7 DUCT' MOUNTED SMOKE DETECTOR PROVIDED AND INSTALLED BY DIV. 16.
-i� M8 HEAT PUMP AIR- COOLED SPLIT SYSTEM WITH EVAPORATOR SECTION
-' -', SUSPENDED FROM ABOVE WITH INTEGRAL SUPPLY AND RETURN AIR
DEVICES, 5 KW ELECTRIC HEAT, 1/4 H.P. FAN MOTOR ® 400 CFM.
TOTAL CAPACITY IS 14,130 BTUH 0 80/67 E.A.T. UNIT ELECTRICAL
IS 288/1 PHASE, 30.9 F.L.A., 39.2 M.C.A.. UNIT IS EQUAL TO
AIR TECHNOLOGY SYSTEMS MODEL OHS- 012 --AR WITH OPTIONAL REMOTE
-�• }� PROPELLER TYPE CONDENSER MODEL HE5- 012 -LAA. ROUTE THE CON-
-` r DENSER LINES THROUGH ROOF TO REMOTE CONDENSER.
_7 n ���
1�l, M9 QUADRANT TO ALLOW F R !
CONTINUOUS RAISED T G
1 1 /2" OPERATOR
HIICK INSULATION.
M10 DOUBLE WALL FLUE UP THROUGH ROOF. TERMINATE WITH WEATHER-
\'�'C �tf, ,,� PROOF APPROVED BRIEQERT CAP. FLASHING AND FLASHING COLLAR
Yy k��� T REQUIRED LOCATIONS AND SIZES OF ALL ROOF OPENINGS
_ OIL Mil 1 COORDINA E Q
,M WITH METAL ROOFING MANUFACTURER.
ir O' •, M12 GAS FRED LOW INTENSITY TUBULAR INFRARED TYPE HEATERS EQUAL TO
REZNOR MODEL RTN- 125 -50 - 125,000 BTUH INPUT WITH 50' REFLECTOR
CHAIN MOUNT AT 19' -0" AFF PER MANUFACTURER'S RECOMMENDATIONS.
9 _ PROVIDE PROGRAMMABLE 7 -DAY T -STAY WITH COVER. (ONE PER EACH OF
r /- • \ (6) SIX UNITS) UNITS ARE VENTED TYPE. ROUTE 4° ROUND ELBOW
AND VERTICAL FLUE STACK THROUGH ROOF (METALBESTOS PS DOUBLE
WALL) AND TERMINATE WITH APPROVED VENT CAP.
►S'a P'� '� ' M13 CENTER OF HEATER AT 12' -0' FROM INSIDE OF WALL. R- RECTOR TO
�p �t ` BE ANGLED IN TOWARDS CENTER OF BUILDING AT 30 DEGREE ANGLE.
�\ Vr D►`�� • (, \�� � • N�� � N`�`'��N��� �PVa � �, - � (TYPICAL OF Z) ,
M14 CENTER OF HEATER AT 28' -0' FROM INSIDE OF EXTERIOR WALL. RE-
�� FLECTORS TO BE IN HORIZONTAL POSITION.
r
+ yv�- (� w .���N G - 0 M15 CAR -MON FUME EXHAUST WITH TOTAL OF (10) TEN 30'x 4' ROUND
A POQ� r� V p'R� FLEXIBLE TUBING RUNS WITH TUBING SLINGS, PULL -UP SET AND
S�� L� \aV `� \ �, STAINLESS STEEL CONE ADAPTERS TO FIT OVER EXHAUST PIPE. MOUNT
go L� \(3V "Q� BOTTOM OFTHROUGHQROOF WITH (PHENOLIC COATED, SCREENED GALVAN-
IZED U Q P•r"' FAN DUCT
GALVANIZED GOOSENECK. PROVIDE T- SPLITTERS AT EACH DROP
PER DETAIL.
_ ` ` � � • ��,�v_` (�\ � , �' / • � M 16 EXISTING EXHAUST FAN PROVIDED D BY OWNER- VERIFY FAN 1S CAPABLE
✓� \ i
` n OF DELIVERING 6300 CFM AT 3.5" W.G. STATIC PRESSURE. IF FAN
IS INCAPABLE OF DELIVERING REQUIRED CFM, PROVIDE BELT DRIVE
y \N�(j B.I. FAN, 5 HP, 480/3 PHASE, WITH ELECTRICAL DISCONNECT. FAN
• /� ` 4@ 4j ` INTERNAL PARTY# TO HAVE PHENOLIC RESIN COATING.
M17 MOUNT THERMOSTATS AT EXTERIOR WALLS ON 1 /2" THICK RIGID FIBER -
,� GLASS PAD (TYPICAL).
�o V �G s M18 12 "x 12" SUPPLY AND RETURN DUCTS UP TO SECOND FLOOR CEILING
��`��� • �l J �Z, SPACE.
M19 6' ROUND EXHAUST DUCT RISES UP THROUGH ROOF AND TERMINATES
o WITH SCREENED ROOF CAP.
�'���'� %`: // ♦ i �' M20 20 "x 12" SUPPLY DUCT AND 20 "x 10" RE URN DUCT PENETRATES 2
HOUR FIRE WALL AT SECOND FLOOR PLENUM SPACE AND DROP DOWN
WALL, THROUGH WALL, TO FIRST FLOOR PLENUM SPACE. INSTALL
2 -HOUR FIRE DAMPERS AT ALL FOUR (4) PENETRATIONS OF FIRE
WALLS.
1�
MECHANICAL SYMBOLS
r^.' • 1 REFERENCE TO DETAIL
AND SHEET NUMBER
S
EQUIPMENT FURNISHED
% r BY DIVISION 15
+' EQUIPMENT FURNISHED
g . . w _ ,. _ _._ Illlf_fI
_ � BY OTHER DIVISIONS
O THERMOSTAT
V
FSDI DUCT MOUNTED SMOKE DETECTOR
- 4" ssc
AFF ABOVE FINISHED FLOOR
• > MANUAL VOLUME DAMPER
I DUCT RISE
D -- CONDENSATE DRAM LINE
,•,.L ,�. .rR �.,; —RL— REFRIGERANT LIQUID LINE
W. 106th. St.
—R$= REFRIGERANT SUCTION LINE
SUPPLY AIR DEVICE
RETURN AIR DEVICE
4� SUPPLY AIR DUCT
..•��.. RETURN AIR DUCT
MECHANICAL & PLUMBING SITE PLAN
..N�wm EXHAUST /OUTSIDE AIR DUCT
NORTH SCALE: 1"'= 50' –•0" AL FIRE DAMPER (HI -HOT TYPE)
REFRIGERANT FILTER /DRYER
�Q}-- SITE GLASS
THERMAL EXPANSION VALVE
PLUMBING NOTES -
P1 COORDINATE ROUTING Of PLL vIBING PIPING ABOVE CEILING AS NECESSARY
TO AVOID CONFLICT WITH HV� � DUCTWORK. REFERENCE HVAC DRAWINGS
PRIOR TO INSTALLATION.
P2 VERIFY EXACT LOCATION OF Al PLUMBING FIXTURES IN OR ATTACHED TO
CASEWORK W!TH ARCHITECT I riOP DRAWINGS.
P3 WATER HEATER TEMPERATU .E /PRESSURE RELIEF DRAIN PIPE TO BE FULL
SIZE OF RELIEF VALVE OU LET. ROUTE DRAIN PIPE THRU EXTERIOR WALL
AND TERMINATE WITH A 9 ELL.
P4 PROVIDE 12" AIR CHAMBERS FOR DOMESTIC HOT AND COLD WATER PIPING
AT ALL SINGLE FIXTURES.
P5 PROVIDE J.R. SMITH #5020 HYDROTROL
P6 PROVIDE INSULATED HUB DRAIN ABOVE CEILING FOR AC CONDENSATE DRAIN. ,
COORDINATE EXACT LOCATION AND HEIGHT OF HUB DRAIN WITH HVAC
CONTRACTOR PRIOR TO INSTALLATION.
P7 FOR CITY WATER AND SANITARY SEWER TAP FEE, METER INSTALLATIONS AND
REQUIREMENTS FOR CONNECTION TO CITY MAIN CONTACT: INDIANAPOLIS
WATER COMPANY, 1220 WATERWAY BLVD., INDIANAPOLIS, INDIANA. ATTN:
STAN GRAVES (317) 263 -6446
P8 PROVIDE COLD WATER SHUT -OFF VALVE IN CONCRETE BOX WITH CAST IRON
LID FLUSH TO FINISHED GRADE.
P9 MOUNT TOP RIM OF WATER CLOSET 18' AFF.
P10 MOUNT TOP RIM OF WATER CLOSET 15" AFF.
P11 MOUNT TOP LIP OF URINAL 17" AFF 1
P12 MOUNT TOP RIM OF LAVATORY 33" AFF.
P13 MOUNT TOP OF SPOUT OPENING ON ELECTRIC DRINKING FOUNTAIN 36" AFF.
P14 WHERE SERVICE SINK ABUTTS WALL PROVIDE NEOPRENE CAULKING ROPE,
CAULK WITH SILICONE 'SEALANT.
P15 PROVIDE TYPE "K' COPPER UNDER SLAB WITH CORROSION PROTECTIVE TAPE.
P16 PROVIDE "J.R. SMITH" MODEL #2698 WATER SAVER TRAP PRIMER P -TRAP
(FOR F.D.) IN -LIEU OF SPECIFIED P -TRAP ON "-2 OF THE PLUMBING
FIXTURE SCHEDULE.
P17 FOR GAS TAP FEE, GAS METER INSTALLATION AND ALL REQUIREMENTS FOR
INSTALLATION AND CONNECTION TO UTILITY COMPANY METER, CONTACT:
INDIANA GAS, MR. JEFF AUTRY AT (317) 776 -5544.
P18 PROVIDE GAS COCK AND 6' DIRT LEG ADJACENT TO CONNECTION TO GAS
CONSUMING EQUIPMENT.
P19 ALL MISCELLANEOUS INTERIOR BRACKETS SHALL BE SHOP PRIMED UNLESS
GALVANIZED OR STAINLESS STEEL.
P20 REFERENCE MINIMUM LINE SIZE SCHEDULE FOR ALL SIZES NOT SHOWN ON
PLAN AND RISER.
P21 GAS UP THRU ROOF WITH GAS COCK SHUT -OFF AND TAP TO ROOF TOP
UNIT, SIZED AS NOTED.
P22 LINE SIZE GAS COCK SHUT -OFF WITH TAP TO HEATER.
P23 ARROW INDICATES DIRECTION OF SLOPE OF COMPRESSED AIR PIPING. ALL
TAPS TO COMPRESSED AIR MAIN TO BE MADE FROM TOP OF MAIN.
P24 PENETRATION THRU FIRE RATED WALLS ARE TO HAVE FIRE SAFING INSULATION
WITH FIRE RESISTIVE SEALANT (TYPICAL). REFER TO ARCHITECTURAL PLANS
FOR RATED WALL LOCATIONS.
P25 VERIFY EXACT LOCATION AND SIZE OF ALL EXISTING PLUMBING LINES PRIOR
TO INSTALLATION OF NEW PLUMBING LINES.
P26 PROVIDE AND INSTALL 1/2" X 3/8" X 3/8" DOUBLE STOP FOR FUTURE
VENDING AREA. VERIFY HEIGHT WITH ARCHITECT.
P27 FOR GAS LOCATION, METER INSTALLATION, AND REQUIREMENTS FOR CONNECTION,
CONTACT: INDIANA GAS, P.O. BOX 1700, NOBLESVILLE, IN 46060, ATTN: JEFF
AUTRY (317) 776 -5544.
P28 GAS COMPANY WILL CHANGE OUT EXISTING METER SIZED FOR NEW TOTAL
3750 CFH TOTAL LOAD. ROUTE 4' LINE FROM DISCHARGE SIDE OF METER
THROUGH EXISTING OPENING UP WALL INSIDE PAINT SHOP. RE -SEAL GAS
PIPE PENETRATION WITH SILICONE SEALANT. TEE 4" GAS LINE WITH NEW 3"
GAS LINE AND LEG TO MATCH SIZE OF EXISTING GAS MAIN.
PLUMBING S4YMBOLS
1 REFERENCE TO DETAIL
P -1 AND SHEET NUMBER
POINT OF CONNECTION,
NEW TO EXISTING
®EQUIPMENT FURNISHED
BY DIVISION 15
®EQUIPMENT FURNISHED
BY OTHER DIVISIONS
AFF ABOVE FINISHED FLOOR
U.G. UNDERGROUND
- -- DOMESTIC COLD WATER,
- - -- OOMESTIC HOT WATER: 120'
--}� PIPE RISER DOWN
- ----iQ PIPE RISER UP
SOIL OR WASTE ILNE
—SD— STORM DRAIN LINE
—OD— OVERFLOW DRAIN LINE
— EG — EXISTING GAS LINE
— Ea, — EXISTING AIR LINE
- - - -- VENT LINE
0 CD CLEANOUT IN FLOOR OR GRADE
--"I C0 CLEANOUT IN WALL
P -TRAP
-4j2 FD FLOOR DRAIN
() VT_R VENT THRU ROOF
0 RD ROOF DRAIN
0 OD OVERFLOW ROOF DRAIN
[i- HB
RECESSED HOSE B!BB
�F-FPHB
FREEZE PROOF HOSE BIBB
F--- -�
DRAIN VALVE W/ HOSE THREAD
—>q
GATE VALVE
--—
GLOBE VALVE
—�}--
CHECK VALVE
—A—
COMPRESSED AIR LINE
—G—
GAS LINE
—W—
WATER LINE
— �jF- --
UNION
— 3
CAPPED PIPED
o—+-HB
HOSE BIBB
B,T,C. •
BRANCH TO CONNECTION
t _
GAUGE COCK
THERMOMETER
DUPLEX OUTLET COMPRESSED
AIR DROP
141 BREVARD CT CHAR
LOT TE , NC 704 535 0477 .
rwirr
�oAx E `
Mils VISION$
irg11M1��� � .'dW"rw