HomeMy WebLinkAboutFN
1
r`
1
65' -2" O.T.O. STUDS
29' -4" 6' -4" 1
29' -6"
-- 6'_6" 3' -4" 3' -0" 3' -4" 6' -6" 3' -4" 4' -1" 3' -4" 2' -6"
3' -4" 3' -0" 3' -4" 6' -6" 3' -4" 3' -0" 3' -4"
. 3 - 5" ,
1 - THE
2 3 Ll A4.6 A5.5 A5.44
O O
O
09
=1
N _
2 Q
A
5.3
12
5
N � 1
V 207
A4.1
1
0 °
I F00D -
°
1
0o
ISTAIR
Lo 8 206 2
200 -
7
A4.1
O 202 S 204
1 SHWR
A4_5 2 3 203
Y^2 TLT
s�
A5.2 \ 202 /
4
Nt
O
� G N
1
7
= OFFICE
N
d
2-8*
4
N _-
N
{
0
N
0
m
4
A5.1
1
.. E
3, -1»
C
i
m► ,3► _
222 13
BALCONY A4.3 SIM.
ii
_
s
. Ism
15
ADMIN
118'-8"
12' -10"
Di-yj
15-0"
11
LOBBY BELOW
LI2i
2 0
i
2 _
O v
1' -4"
2
0 10
i co
1
� N 4
10
10
8
3 2
1 _
t1►Z.Ttm HAL. A5.4 °
OFFICE
9' -8' MASONRY 5' -11"
9
A4.1
SIM
Un =
t2 ;•�
r
( rz
F -1 1 0 Lo
3 10 o ELEVATOR p
4
10 ul -
' 2
10
. I
10 6 t I
;.,
21 A4.1 1
09
HALL 4 6
37' -6"
2 t0 10
2
05 o
U-)
t
_ 1
HVAC W/N
1 N
15 212 15 212 COATS I
SIM. ; 4 UTILITY a
7 A
I 13 I 10 °o
a ENTRY {
It
2
213 + + Aa.S
ST OR. 214 a
KITCHEN A4.5 15
20s � +1 + 3
CONFERENCE I I Aa.S
' 05
I a a
M
A4.5 SIM
2'- _
05 17 - - -- -
Q
7 I LIVING RM
I 215
_ 1
-1 - 6' -4" 3"
20 II 8' -7" 3' -8" 6' -11"
3 14 .
o-�,
A5.3 At3 I 6
13 t5
4 A4.3 A4-3 i MCI!
216 218
v
u') HALL
1 221 N 1 220
°i BALCONY o 'u-) CLOS. 2' -6"
LINEN
19
2
A5.6 9 0- 20 Ij 220 1217
�► , 9
5 14
A4.1
WINDOWS ABOVE ' 14
4
A5.1 3
A5.1
14
N
O
1 2 2 7
A5 1 A4.6 A5.1 A4.5
3' 2" 12' -10"
12' -7" 19' -2"
3 -42"
c 4
o A5.1
I
1 65-4"
9ND FLOOR PLAN
1/4„ = 1'_0»
13' -5"
o '
1
in
0
2 �
5.4
O � {
Sim
{
v
12
7 okv
BED 1090! 1
19
BATH
Ca
4
o
4
O O G
Sim Sim Sim
1
2
A5.2 5.2
3' -9" 3' -4" i' -4" 3' -4" 1' -4" 3'- 3' -9"
20' -2"
4
00
{
N
1
M
a�
w Z
' ~_ L NOTES �W •A
ENERA u F_ W G p
ZZu pW �
1. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL d w U
DIMENSIONS AND JOB CONDITIONS. ANY DEVIATION FROM WHAT IS NOTED Z = Q � 2 U
IN DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT w P z oo 3
IMMEDIATELY, p Z ? d Q
2. ALL DIMENSIONS SHOWN ARE TO FACE OF BRICK, MASONRY OR WOOD
t_2 u-
lz =Z
STUD FRAMING, UNLESS NOTED OTHERWISE. p W O p 0 u I
=0WQS
3. NOT USED. ~ 3 Z u
4. PROVIDE WOOD BLOCKING IN STUD WALLS FOR ANY WALL SUPPORTED Q Z � O a
ITEMS. ZUQO?Oc~Z9 :D
Ah A
5. PROVIDE APPROVED FIRE RATED STOPPING MATERIALS IN ANY OPENINGS 3 '^ U W 0 . oc
I IN FIRE RATED ASSEMBLIES. °� 'L' °C u' Z
ui a
t7ZJ Q 0 N
uj pOZOu
6. REFER TO DOOR AND WINDOW SCHEDULES FOR ALL MATERIALS, O Z ZZ 3 O
/ FINISHES AND HARDWARE INFORMATION.
o u
7. REFER TO ELEVATIONS FOR EXPANSION JOINT LOCATIONS. LIJ -.D
W Q L
8. ALL MATERIALS WHICH WILL BE LOCATED IN THE CEILING PLENUM SHALL N, C
/ BE RATED FOR SUCH INSTALLATION, OR PROTECTED TO PROVIDE 000
COMPLIANCE. THIS INCLUDES, BUT IS NOT LIMITED TO, POWER AND LOW Q '
VOLTAGE WIRING, TELECOMMUNICATIONS CABLING, PLUMBING SUPPLY AND W Z a
DRAIN LINES, 4ND SUPPORTING BRACKETS /BLOCKING FOR CEILING HUNG
ITEMS. ALL WOOD FRAMING SHALL EITHER BE ENCLOSED IN 5/8" TYPE "X" z 0 0
GYP BOARD, OR 8E FIRE RETARDANT TREATED. Z ? r
o�
9. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISH MATERIALS TO BE r.
V
USED ON THE PROJECT TO THE ARCHITECT FOR REVIEW, PRIOR TO LiJ
ORDERING ANY PRODUCTS. THE CONTRACTOR SHALL BEAR SOLE M _j r
RESPONSIBILITY FOR ANY MATERIALS ORDERED INCORRECTLY WHEN THAT i11 _
MATERIAL WAS NOT REVIEWED BY THE ARCHITECT. "-
O N
10. PROVIDE CONCRETE FILLED STEEL PIPE BOLLARDS AT ALL REQUIRED r m z p J
UTILITY EQUIPMENT LOCATIONS (IE: GAS METERS, ELECTRICAL z ui Z O m
TRANSFORMERS /PANELS, ETC...) COORDINATE WITH UTILITY COMPANY AND O
DESIGN BUILD CONTRACTORS FOR NECESSARY LOCATIONS, REFER TO CIVIL _ n a
ENGINEERING DRAWINGS FOR BOLLARD SPECIFICATIONS AND ADDITIONAL p U u rn Z
INFORMATION.
0
KEY NOTES
1. CONCRETE FILLED STEEL PAN STAIR TREADS WITH BROOM FINISH.
REFER TO 1/A5.7 FOR DETAILS.
2. REFER TO A2.1 FOR ROOF INFORMATION.
3. MECHANICAL CHASE COORDINATE W/ ENGINEERING DRAWINGS.
4. FIBERGLASS UTILITY SINK ON LEGS. REFER TO ENGINEERING DRAWINGS.
5. CAGES PROVIDED BY OWNER.
6. 16" DEEP VINYL COATED WIRE SHELF W/ CONTINUOUS HANGER ROD
I BELOW. INSTALL W/ ROD AT 5' -0" A.F.F.
7. (4) 16" DEEP VINYL COATED WIRE SHELVES SPACED @ 12" CLEAR
BETWEEN WITH BOTTOM SHELF ® 24" A.F.F.
8. NO FINISHES IN THIS ROOM. APPLY TYPICAL 5/8" TYPE "X" GYP
BOARD TO INTERIOR WALLS, MECHANICAL CHASES, AND UNDERSIDE OF
TRUSSES ONLY. TAPE AND FLOAT JOINTS.
9. EXTERIOR BALCONY. REFER TO SECTIONS.
10, CMU WALL TO BE FURRED OUT W/ 2X FURRING @ 16" O.C. AND
5/8" TYPE "X" GYP. BOARD. ALIGN GYP BOARD WITH OTHER FINISH FACES
OF WALLS.
11. OPEN TO FIRST FLOOR.
12. FRAME WALL PAST WINDOW ® LOCATION SHOWN. WINDOW IS SPANDREL
PANEL. REFER TO WINDOW ELEVATIONS.
13. CONCRETE FILLED STEEL PAN TREAD STAIRS. REFER TO DETAILS.
14. 12" C.M.U. 0 ENTRY REFER TO STRUCTURAL DRAWINGS.
I 15. REFRIGERATOR, WASHER /DRYER AND DISHWASHER PROVIDED BY OWNER,
PROVIDE WATER SUPPLY AND WASTE LINES. REFER TO ENGINEERING
DRAWINGS.
16. ELECTRIC STOVE AND MICROWAVE BY OWNER.
17. ALL WALLS WITHIN APARTMENT TO BE WALL TYPE 2 SIM U.N.O.
18. T. ROUGH OPENING OF THIS WINDOW TO ALIGN W/ T/ ROUGH
OPENING OF WIN60W °H" (120' -0 3/8 ")
19. TEMPERED GLASS SHOWER WALL AND FRAMELESS DOOR. TOP OF
GLASS TO BE AT 7' -0" A F.F.
20. PROVIDE SLIDING SCREEN DOOR FOR ACTIVE LEAF.
21. FRAME AROUND COLUMNS WITH WOOD FURRING AND 5/8" TYPE
GYP BOARD.
MILLWORK NOTE:
BASE CABINETS IN 206 TO HAVE 4" TALL CMU BASE, GROUTED TO FLOOR.
BASE TO SET BACK 2" FROM FACE OF CABINET TO CREATE TOE KICK.
EXTEND WALL BASE OVER CMU.
Ilb
Q
0
4 O o
_ o �
o
Z N
�. c7 V0 ;�J'�
d
W
U
J
493
F-
Q
H
amo
OW
=
Z
J
Q
LIJ
EC)Q
Z
O
Z
Q
oc
Z
F-
O
lAft
r
13
z
w
J