HomeMy WebLinkAboutDEXISTING LINE
CONNECT TO EXISTING LINE
3/4" CW
-I
3/4" HUJ
3/4" ClU
/8" CUJ
1/2" GU)
1/2" HLU
/8" CU1
P1
P2
Water Isometric
EQUIPMENT SCHEDULE
All -1 YORK HORIZONTAL AIR HANDLER
MODEL #AHE30133X, 208 / 230 VOLTS 1 PH
WIT] 17.5 KW ELECTRIC HEAT.
CU -I YORK 24,000 BTU CONDENSING UNIT
MODEL #GCGD24S41S3, 208 / 2301 PH
WITH 410A REFRIGERANT.
2" VTR
2" i " in rd= n iii
FIN
TING
Sanitary Isometric
Partial Mechanical Plan
1/4' - T -0'
GENERAL MECHANICAL NOTES
1. ALL SYSTEMS SHALL BE INSTALLED PER APPLICABLE STATE,
LOCAL AND NFPA CODES.
2. ALL DUCTWORK SHALL BE GALVANIZED METAL INSTALLED
PER SMACNA STANDARDS. TURNING VANES SHALL BE
PROVIDED ON ALL ELBOWS LARGER THAN 12"XI2". ALL
BRANCH TAKEOFFS ON RETURN AND SUPPLY DUCTS SHALL
HAVE SINGLE BLADE VOLUME DAMPER.
3. _ ALL SUPPLY/RETURN DUCT CONNECTION TO UNFFS SHALL
HAVE VIBRATION ISOLATION FLEX CONNECTIONS.
4. ALL VISIBLE BOXES AND DUCT BEHIND RETURN AND SUPPLY
AIR GRILLES SHALL BE SPRAY PAINTED BLACK.
5. MAXIMUM FLEX DUCT LENGTH TO GRILLES AND DIFFUSERS
SFU1,LL BE 6' OR AS INDICATED.
6. REFER TO DRAWINGS FOR EXACT LOCATION OF WALLS,
CHASES AND CEILING TYPES.
GENERAL PLUMBING NOTES
1. ALL SYSTEMS SHALL BE INSTALLED PER APPLICABLE STATE,
LOCAL AND NFPA CODES.
2. WORK SHHLL INCLUDE THE RUNNING OF ALL SUPPLY AND
WASTE PIPING, INSTALLATION OF FIXTURES AS SPECIFIED AND
THE NECCESSARY CONNECTIONS TO THE EXISTTNG SYSTEM.
3. CONTRACTOR TO VERIFY LOCATION OF ALL EXISITNG
PLUMBING LINES AND ADJUST NEW LINES TO
ACCOMMODATE EXISTING LINES.
4. CONTRACTOR TO NOTIFY ARCHITECT PRIOR TO
COMMENCING WORK IF EXISTTNG CONDITIONS ARE
SUBSTANTIALLY DIFFERENT THAN INDICATED.
5. REFER TO DRAWINGS FOR EXACT LOCATION OF WALLS,
CHASES.
CU -1 @1 First Floor
1/4' - T -0'
PLUI„15ING FIXTURE SCHEDULE
MARK
TYPE
MODEL
P -1
BREAK ROOM
ELKAY STAINLESS STEEL SINK PACKACsE LH1122C
1GW
SINK
(SINK AND TRIM)
P -2
ICE MAKER
REMARKS
CTRL.
VALVE
CAPACITY
WATER �4EATER SCHEDULE
MARK
TYPE
LOCATION
MODEL
GALLON
RECOVERY
1GW
DELTA "T"
VOLT
PHASE
REMARKS
REM. CTRL
REMARKS
CTRL.
OR EQUAL
CAPACITY
GPH
IT / TELE
BRAUN
10
WH -1
ELEC.
ABOVE SINK
A.O. SMITH
DEL
10
is
120/1
T 4 P VALVE
-105
PRAIN PAN
EXHAUST FAN SCHEDULE
MARK
TYPE
SERVICE
MODEL
OR EQUAL
CFM
AMPS
+gyp
INCH
SP
RPM
DRIVE
VOLT /
PHASE
REM. CTRL
REMARKS
CTRL.
BY
EF -I
CEILING
EXHAUST
IT / TELE
BRAUN
10
115/1
JOHN
MOSELE
ARCHITECT
ARCHITECTURE
PLANNING
INTERIOR ARCHITECTURE
317- 574 -9408
I
ERICk ��ii
.' REGISTERED
33389
STATE OF
INDIANA
�RCHi TSC \\��
5k)�4�
TENANT
IMPROVEMENT'S
FOR
ROBERGE &
ROBERGE
SUITE 201
REGENTS BUILDING
12775 HORSEFERRY
CARMEL, IN 46032
revision: date: description:
Mechanical Plan
Details, Notes
date: July 15, 201 2
project: 1207
scale: As noted
coord.: JMi
drawn: JIVI A1.3
checked:] M