Loading...
HomeMy WebLinkAboutC806 Aqua Swirl Details STANDARD NOTE:STANDARD NOTE: System shall be designed for the following capacities:1. System shall be designed for the following capacities: Swirl Treatment Flow: 1.1 cfs Peak Treatment Flow: 3.2 cfs Manhole Frame and Swirl Oil/Debris Storage: 37 gal. Oil/Debris Storage: 190 gal. Rim elevations to match finished Cover by Manufacturer. * Please see accompanied Aqua-Swirl * Please see accompanied Aqua-Swirl grade. HDPE risers can be field 32" OD (See Details) specification notes. specification notes. Pipe coupling cut by Contractor. * See Site Plan for actual system orientation. * See Site Plan for actual system orientation. Grade (Rim) by Contractor. Rim elevations to match finished Manhole Frame and A 12" long Stub-out grade. HDPE risers can be field Cover by Manufacturer. 32" OD Riser by Manufacturer. Varies cut by Contractor. (See Detail) Vent Pipe coupling A by Contractor. Varies 12" long Stub-out InletOutlet 18" OD Max by Manufacturer. InletOutlet 12 3/4" OD MAX 42" Gravel Backfill shall extend at 66" least 3.5 feet outward from Swirl Concentrator and for the full height of the Swirl Vent Swirl Inlet/Outlet Concentrator (including riser) Swirl Inlet/Outlet extending laterally to undisturbed soils. (See MH Arched Baffles Octagonal Base Plate Detail Below) 60" Arched Baffles 42" A 104" 38" Arched Octagonal Base Plate 42" Baffles Arched 42" Gravel Backfill Baffles 68" A Plan View 66" 12"Plan View Bedding Bollards shall be placed around access riser(s) in non-traffic areas to prevent Bollards shall be placed around access Gravel Backfill inadvertent loading by maintenance Undisturbed Soil riser(s) in non-traffic areas to prevent vehicles. inadvertent loading by maintenance Phone (888) 344-9044 vehicles. www.aquashieldinc.com Cover Gravel Backfill shall extend at least 3.5 feet outward from Cover Swirl Concentrator and for the SoilSoil 4" Bedding 12" full height of the Swirl Concentrator (including riser) SoilSoil 4" Frame Concrete extending laterally to 1/2" Concrete 1/2"1/2"undisturbed soils. (See MH Detail Below)Frame Concrete 1/2" Concrete 1/2" 1/2" Gravel Backfill Undisturbed Soil Gravel BackfillPlace small amount of concrete to support and Gravel Backfill Riser Gravel BackfillPlace small amount of level manhole frame. DO concrete to support and Riser NOT allow manhole frame level manhole frame. DO to rest upon HDPE riser. NOT allow manhole frame Manhole Frame & Cover Detail to rest upon HDPE riser. Manhole Frame & Cover Detail Section A-A For Non-Traffic Areas Only Section A-A Document:AS-2 STDDocument:AS-4 STD For Non-Traffic Areas Only NTS Drawn By:JTDDrawn By:JTD NTS Aqua-Swirl Concentrator Model AS-2 CFD Standard Detail Scale:1:20Scale:1:20 Aqua-Swirl Concentrator Model AS-4 CFD Standard Detail Date:04/18/06Date:04/18/06 Phone (888) 344-9044 Fax (423) 826-2112 Phone (888) 344-9044 Fax (423) 826-2112 U.S. Patent No. 6524473 and other Patent PendingU.S. Patent No. 6524473 and other Patent Pending www.aquashieldinc.com www.aquashieldinc.com