Prelim Drawing Sheet 13 08-13-2012.pdf
BA S E M E N T E L E C T R I C A L & L I G H T I N G P L A N SC A L E : 1 / 4 " = 1 ' - 0 " RE F . FI N I S H B A S E M E N T F L O O R EL E V . = 8 8 4 . 6 9 ' R R R R R R R SD R R RR R R R R R R R R R R RR R R R R R R R R R R R R R R R R R R SD R R R R R RR R R RR R R R R R R R R R R R R R R SD R R R R R R R R R R R R R R R R SD R RR R R R R R R C GF C I 3 C Unfinished Closet 12 " C O N C R E T E FO U N D A T I O N W A L L (T Y P I C A L ) ST A I R W A Y UP STAIRWAYUP12" CONCRETEFOUNDATION WALL(TYPICAL)1. NEW ELECTRICAL WORK AND ELECTRICAL DISTRIBUTION SYSTEM SHALL CONFORM TO ALL APPLICABLE REQUIREMENTS OF THE LATEST ADOPTED EDITION OF THE INDIANA ELECTRICAL CODE. DETAILS OF NEW ELECTRICAL DISTRIBUTION SYSTEM SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR.2. PROVIDE 400 AMP ELECTRCIAL SERVICE PANEL AT THE LOCATION SHOWN ON THE FIRST FLOOR LIGHTING & ELECTRICAL PLAN (DRAWING SHEET #14). PROVIDE A CONCRETE ENCASED ELECTRODE FOR THE ELECTRICAL PANEL. DETAILS OF THE NEW ELECTRICAL SERVICE PANEL INSTALLATION SHALL BE PROVIDED BY THE PROJECT ELECTRICAL CONTRACTOR. 3. VERIFY OR PROVIDE G.F.C.I. PROTECTED OUTLETS IN GARAGE, BATHROOMS, TOILET AND LAVATORY ROOMS, AT KITCHEN COUNTER TOPS, AND AT ALL EXTERIOR LOCATIONS.4. VERIFY NEW ELECTRICAL LAYOUT AND LIGHTING FIXTURE SELECTION WITH OWNER, PRIOR TO ROUGH-IN.5. AN APPROVED SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA. AT LEAST ONE SMOKE DETECTOR SHALL BE INSTALLED ON EACH STORY (INCLUDING THE BASEMENT STORY). REQUIRED SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP. DETECTORS SHALL EMIT A WARNING SIGNAL WHEN THE BATTERIES ARE LOW. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION. THE SMOKE DETECTORS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS WITHIN THE CIRCUIT.6. AN APPROVED CARBON MONOXIDE DETECTOR SHALL BE INSTALLED ON THE CEILING OR WALL OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS. AT LEAST ONE CARBON MONOXIDE DETECTOR SHALL BE INSTALLED ON EACH STORY (INCLUDING THE BASEMENT STORY). 7. PROVIDE ARC-FAULT CIRCUIT INTERRUPTER AT ALL NEW BEDROOMS, AS PER NEC 210.12.8. A MINIMUM OF TWO SMALL APPLIANCE BRANCH CIRCUITS, AT 1500 WATTS EACH, ARE REQUIRED TO SUPPLY THE KITCHEN.9. NEW DINING ROOM OUTLETS SHALL BE ON A 20 AMP CIRCUIT.10. AN INDIVIDUAL BRANCH CIRCUIT IS REQUIRED FOR THE FAU, AS PER NEC 422.12.11. NEW LIGHTS IN KITCHEN, BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS MUST BE HIGH EFFICACY, OR CONTROLLED BY A "MANUAL-ON" MOTION SENSOR.12. NEW LIGHTS IN ALL HABITABLE ROOMS MUST BE HIGH EFFICACY, CONTROLLED BY A "MANUAL-ON"MOTION SENSOR, OR CONTROLLED BY A DIMMER.13. NEW OUTDOOR LIGHTING ATTACHED TO BUILDINGS MUST BE HIGH EFFICACY, OR CONTROLLED BY A MOTION SENSOR AND PHOTO CONTROL.14. ALLOW 48" FROM THE FLOOR TO THE CENTERLINE OF SWITCHPLATES, UNLESS OTHEWISE NOTED.15. ALLOW 48" FROM THE FLOOR TO THE CENTERLINE OF RECEPTACLES, UNLESS OTHEWISE NOTED.16. VERIFY OR PROVIDE FOUR SPARE CIRCUITS IN THE ELECTRICAL PANEL FOR FUTURE USE.17. ALL NEW LIGHTING FIXTURES TO BE COMPLETE WITH BULBS AND/OR TUBES. TUBES SHALL BE "DELUXE WARM WHITE".|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| ELECTRICAL & LIGHTING NOTES ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||State of California Licensed Architect Renewal Date:November 30, 2013F. Paul Sheehan C-23133 DATE:SCALE:DRAWN BY:JOB NO.DRAWING SHEET NO.OF 15 SHEETS08-14-2012 AS NOTED F.P.S.108-102A NEW CUSTOM RESIDENCE FOR:1004 WEST 141ST STREET CARMEL, INDIANA 46032design & plans by:Sheehan and Associates architecture • project planning • construction F. Paul Sheehan, Architect 305 Calle Higuera Camarillo, CA 93010 (805) 482-7209 These drawings and specifications are the property of Sheehan and Associates, and are protected under all applicable copyright laws. They are not to be changed,copied in whole or in part, nor used on any other work without the express written consent of Sheehan and Associates.COPYRIGHT NOTICE © 2012 Sheehan and Associates F. Paul Sheehan, ArchitectREVISIONS 13