Loading...
HomeMy WebLinkAboutCorrespondence: Kimley-Horn MFPG Waiver Request Suite 2125 205 W. Wacker Drive Chicago, IL 60606 August 23, 2012 Gary Duncan Assistant City Engineer, City of Carmel One Civic Square Carmel, IN 46032 (317) 571-2441 Re: Olive Garden Restaurant – 10206 Michigan Rd., Carmel IN MFPG Waiver Request Dear Mr. Duncan: Per the City of Carmel Stormwater Technical Standards Manual Section 104.02, “Minimum Flood Protection Grade [MFPG] of all structures fronting a pond or open ditch shall be no less than 2 feet above any adjacent 100-year local or regional flood elevations” and “The Lowest Adjacent Grade for residential, commercial, or industrial buildings outside a FEMA or IDNR designated floodplain shall have two feet of freeboard above the flooding source’s 100-year flood elevation under proposed conditions.” In addition, it has been noted in review comments from the City of Carmel Engineering Department, that the MFPG must also be two feet greater than surface water elevation onsite assuming all inlets are plugged. The proposed development has three proposed detention pond areas, each with overflow weir spillways. The maximum overflow weir elevation of the ponds is 892.82 (above all the 100-year storm elevations for all the ponds). The finished floor elevation of the building is 895.05. This provides 2.23 feet of freeboard. Due to grading constraints of the site, the greatest water elevation onsite is 894.05 assuming all inlets are plugged. This provides one foot of freeboard to the finished floor elevation of 895.05. Grading constraints prevent the possibility of lowering this an additional foot. A grading constraint for the site includes maintaining a minimum four feet of cover over an existing sanitary forcemain that runs through the north side of the property. Another grading constraint is providing cover over the proposed storm sewer onsite. Lowering onsite elevations would reduce the cover provided on storm sewer. Additionally, proposed detention pond elevations and tie elevations to existing grades limit the grading onsite in the parking areas. While site constraints prevent full compliance of the MFPG City requirement, we are providing over 2 feet of freeboard from overflow weir elevations and have a minimum 1 foot of freeboard from onsite surface elevations. Therefore, we respectfully request a waiver of the MFPG requirement. Please contact me if you have any questions or require any additional information. Sincerely, Kimley-Horn and Associates, Inc. Justin Muller, P.E. 1