HomeMy WebLinkAbout0791.95.3�i � � ! o� P� �►, �. 5 / ,�,P NvH � h RE�LECTED C�ILING LEGEND �EXISTING 2 X 4 (18) DEEP CEL� FLUORESCENT L�GHT _� RE—USED LIGHTING IN NEW LOCATION _� NEW 2 X 4 18 DEEP CELI FLUORE C NT LIGHT TO MATCH EXiSTING _�! � REMOVE & REUSE EXiST(NG LIGHTING �—� -?� EXISTING INCANDESCENT _ __ DOWNUGHT IN RELOCATED ' ' LOCATION -t----�- CEILING MTD. EXIT �IGHT � i8l1 ' W/DIRECTION INOICATION —�------*- Dl1AL—UTE � O SPEAKER � ia ..... ::::: .....: ::::� � � � --r--,---�- � i i -1--�----�- � 1 F � i � -t--�—�- EMERGENCY/NIGHT �IGHT CEILING HUNG LIFE SAFETY AtARM EXISTING 2 X 2 RETURN AIR GRILL EXISTING 2 X 4 RETURN AIR GRILI _� EXISTING SLOT DIFFUSERS � � EXISTING SUPPLY DIFFUSER �EXISTING 2 X 2 LAY—IN GRID � SUSPENSI4N SYSTEM - ---�---r- O � $ � �o �3 THERMOSTAT NEW EXHAUST FAN SWITCH EXiSTiNG LIGNT SWITCH TO REMAlN DIMMER SWITCH THREE—WAY SWITCH NOTE: . NEW 2' X 2' CEILING GRID AND TILES TO BE INSTALLED TO MATCH EXISTING. NOTE: CEILING HEIGNT iS 8'-6" A.F.F. UNLESS OTHERWiSE NOTED ♦ .o . ,y .o�, -9 � s �,�` qs � �� � REFLECTED CE�LItV�G N4TES � 1. CONTRACTOR TO VERIFY EXISTING CONOITIONS aND REPORi ANY �,� EXtSTING H.V.A.0 GRiLLE TO BE RELOCATED DUE TO DISCREPANCIES TO ARCHITECT PRIOR TO CONSTRUCTION. NEW LiGHT LOCATION 2. EXISTING SUSPENDED LAY—IN CEI�ING TO REMAIN. REPLACE � EXISTING SPEAKER IN TMIS LOCATION IN CONFLICT ANY DAMAGED OR MISSING TILES TO MAtCH EXISTING. CONTRACTOR TO VERIFY EXISTING GRID lAYOUT AND �"J WITH NEW ARCNITECTURAL ELEMENT. PLEASE RElOG4TE. CONDiTION. 3 4. 5. 6. 7. 8. 9. 10. 11, SUCCESSFUL IIFESAFETY CONTRACTOR IS RESPONS18lE FpR DESIGN/BUILD OF AI.L SAFETY SYSTEMS. CONTRACTOR IS TO YERIFY QUA�ITITY AND PIACEMENT OF INDICATED SAFEiY DEVICES (EXIT SIGNS, ALARMS, etc� AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. L► SAfElY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REYIEW AND OSTAINING PERMITS. ALL LIFESAFETY DEVICES REQUIRING ELECTRICAL HOOK—UP ARE TO UTtuZE 4—WIRE, 12 GAUGE WiRE. PAINT EXISTING GYPSUM WALL BOARD BULKHEADS TO MATCH CEILtNG AS REQUIRED. EXISTING DIFFUSER CFM'S TO 8E VERIFtED AND BA(J�NCED WITH NEW D►FFUSERS FOR BAIANCED AIR 015TRIBUTION TNROUGNOUT THE SPACE. MECHANICAL CONTRACT�R TO VERIFY EXISTING .CFM'S. EXISTING TRUNK L1NES TO REMAIN. ALl ROOM WAILS TO UNOERSIDE OF SUSPENDED CEILING TYPICAL UNLESS OTHERWISE NOTED. ALL WORK MUST MEET APPlICABLE STATE ANQ LOCAL CODES. VERIFY ANY CHANGES FROM DRAWINGS WITN ARCHiT£CT. PATCH, REPAIR, AND/OR REPLACE CEIItNG GRID SYSTEM WHERE WAILS OR PARTITIONS HAVE BEEN REMOVED TO MATCH EXISTING. RE—USE EXISTING LIGHT FIXTURES WHERE POSSIBLE. CLEAN SALVAGED FIXTURES, RE—LAMP AND REPIACE ANY DAMAGEO LENSES OR 8ALl.ASTS. MECMANICAL AND ELECTRICAL IS QESIGN—�UILO. DEStGN— BUILD CONTRACTOR TO VERtFY IOCATION F: DIFFllSERS, SPRINKLER HEADS, FfRE PROTECTION OEVICES, fXiT . UGHTS, EMERGENCY/NIGHT LIGHT5, THERMOSTATS. IOCATlONS OF ALL OF TNE ABOVE IT�MS NEEO TO BE SUBMITTED TO DESiGNER FOR APPROVAI. LOCATIONS PROVIDED ON TNIS SHEET. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTtON Of THE �ESIGNER BEF`ORE PROCEEOING. REFER TO MECHANiCAL DRAWINGS fOR RELOCATION OF THERMOSTATS. CONTRACTOR t0 VERIFY WITH TENANT BEFORE PROCfEDING. c�a cP� cPs �:.% ca� O ADDITIONAL H.V.A.0 REQUIRED (SUPPLY) ADDtTIONAL H.V.A.0 REQUIRED (RETURN) " H.V.A.C. DIFFUSER IN CONFLICT WITH NEW WALL. RELQCATE PROVIDE 3—WAY SWITCHES FOR OPEN AREA/323. LOCATE SWITCHES HERE. NEW SPEAKER LOCATION (4) EXISTING 2X4 FLUORESCEMT UGHT FiXTUR£S IN THiS AREA TO BE RETURNED TO P#20PER7Y MANAGEMENT. �