FOUNDATION PLAN
SCALE: 1/817 r -0'
aLL I°ARTITIONS ^-( PERIMr✓T�I2 AOP AT INTc�IOR- LGo,%,D �,�+fzIIJG WALLS
21< L ("F, 10"0.0. ON THIS LEVEL.
2. ALL OTHER r^W-TITlOhts 2x4 (0—D la, O.O. ON THIS LEveL _
�. zEE AtzGH. LCCATI -0N OF ALL 1I4TF-R40z- PIzTITIONS WITH F OTIIJbs BELOW.
>b
-z
SECOND
LEVEL
FLOOR FRAMING
PLAN
NM: I. ALL F LDOj -
- 10ISTS 2A I?- (p,
I �vll D. G. u.Iq . o.
WALL BELOW LEVEL BEING FRAMED
Z. ^LL H•EP•teRS IN
FL00F2 JOISTS 2 --ex IO
l (on o c
3o FLOO(Z DE;GY_
-Ep vV12 321 ^F,^,
R^7c -P STUFZD -I- FLOOR 2.4" o.c.
e Pr^w RATING.
SEb �ASTNeIz
SGHBt7ULE �o� NAILINv.
FRAMING DIRECTION
CoNG. FOoTluv
r=^C H VV^Y (Typ�,,pAL,)
P 20VIDE 12t1 THIOV- r0cTINv
W1 S 1 �2u O.O. EA" W^-r.
BEAM SCHEDULE
LEGEND
BEAM
BEARING WALL
I B- I
WALL ABOVE LEVEL BEING FRAMED
WALL BELOW LEVEL BEING FRAMED
2 -2x12 FIT
STACKING WALL
l (on o c
POINT LOAD FROM ABOVE
0
SUPPORT BELOW
0
JACK TO WALL/BEAM BELOW
---- -�
FRAMING DIRECTION
�. --- -� FRAMING DIRECTION BELOW
2B-3
BEAM/HEADER LINE '
Wl\LLS
2 2x10
F. J.
FLOOR_ JOIST
C. J.
CEILING JOIST
I B -I
FIRST FLOOR BEAM NQ
2 B-I
SECOND FLOOR BEAM N4
CB -I
CEILING BEAM NQ
RB -I
ROOF BEAM N9
U.N.O.
UNLESS (VOTED OTHERWISE
W.W.F.
WIRE WELDED FABRIC
D. J.
DOUBLE JOIST
P, T.
PRESSURE TREATED
0. C.
ON CENTER
A.P.A.
AMERICAN PLYWOOD ASSOCIATION
F.
FLITCH PLATE
H. -I
HEADER N°
BEAM SCHEDULE
MARK
BEAM
COMMENTS
I B- I
2- 2,c 12 W1 /gll F
18-2
2 -2x12 FIT
.1olsTe, 2- 12
l (on o c
2B- I
bIX Iq %4� GLULAM
2x10 FZ
2B -2
3 -2x 12
3. A,LL
2B-3
2.2x 12 N!/ I /¢° _
Wl\LLS
2 2x10
4 .
WITH Z%2-"
CB -I
2 -2x to W/ 1 1¢Pr-.W
SP 1
CB-2
5.2x to
5r- HEDULa PoR NP�iLIN Cam.
CB -3
2 -2x 10
RB -I
2- 2x 12
RB -2
R B -3
H - I
2 -2>e-
IP>- 2.
FIRST
LEVEL
FLOOR
FRAMING PLAN
NcvTE I. ALL
.1olsTe, 2- 12
l (on o c
2. ALL
DECK J0jST5
2x10 FZ
Ice,1IO.G
r7
3. A,LL
HEP\c�ER,� ;rJ
gE/,,,R -INCA
Wl\LLS
2 2x10
4 .
WITH Z%2-"
^1-^
K,-,Tf-,p ST11fzD I -PLC 24 "0r, .
SP 1
f TING. SEA
1% ^STE,:Nefz
5r- HEDULa PoR NP�iLIN Cam.
SECOND LEVEL CEILING FRAMING PLAN
NOTE ., I PALL c�ILINb JOISTS 2x10 I�o�� o. G. U.rl.p.
2. ALL HP-^pe12S IN P e^p -io6, WALLS 2- 2xb U.N.O.
13UILbE{2 TO bETelzmi"e COWMH
TYPE "Le PEiz ACTUAL
�oN�IrIONS. MINIMUM 6cWMN
SIzE �19 TALL -) 15 PT FvS-(
vN SIHF e,00 A5U�-,,io F�5e.
Y
PROJECT
v
1 0
N
Dom' I REVISEl
[44 1 1
0,*-� Ic
O�
m
E
,J
ro
..r
C
ro
:r
•
N
1
U)
it
r� W
V1 �
�J4 s
x
N
JOB # TUBE#
0229 -29 1 0229 -29
This plan is the pro rty of
I)esi n Traditions an ma not
be used or p re roduced witKout
their . permission.
Please Note:
Design -lraditions assumes no liahility for anv home
constnlcted from this plan. It is the reslxmsihility of
the purchaser of this plan to perform the following
heforc heglnnitlg actual constnlcti011.
I) Builder or contractor trust verifv :ill I)imensiotls
prior to proceeding with construction.
2) contractor trlust Verify compliance with all local
httdding c(xles in the area where the home is to
he co list nucted.
3) flans indicate locations only; engineering aspects
should incorlxorate actual site conditions.
k aution must he exercisetl in malzing anv changes in
this plan. Only qualified designer, architect, cuntracto
or stnletural engineer should attempt moxlifications,
even minor changes in one area of the house ctJd le
to major problems in another area.
DRAWN I SHEET#
C A