Loading...
HomeMy WebLinkAbout0272.95.1GENERAL NOTES ! 1. THE ATTACHED °LAN8 AND SPECIFICATIONS ARE THE 80LE PRPf'ERTY OF T.dE h2YLAiND GROUP, iNG. ANY UNAUTHORIZED USE OF THESE PLANS WITHOUT THE WR!TTEN CONSENT OF THE RYLAND GROUP IN(-. 15 PROHIBITED. 2. RYLAND GROUP INC. DESIGNS AND BUILDS HOUSING AS SET TH BY THE FORMAT AND PROv7SIONS OF THE 'CABO ONE ANN. TWO FAMILY DtIIELLiNG CODE', 1932 EDITION. ALL CONSTRIjCT!ON SHALL COMPLY WITH SAID CODE AS WELL AS ALL LOCAL GOVERNING CODES AND /OR REGULATIONS. ANY NON - CONFORM1R, DOCLt -"TS DISCOVERED BY THE CONTRACTORS OR HIS AGENTS SHALL 13E CALLED TO THE ATTENTION OF THE MIDWEST ARCH TECTURAL SERVICES OF RY'LAND GROUP. INC. 1513) 611 -8854. 3. THESE PLANS ARE NOT TO BE SCALED FOR CONSTRUCTION PURPOSES. DIMENSION LINES AND NOTES SUPERC:,EDE ALL SCALE REFERENCE. 4. THESE PLANS ARE SUBJECT TO MODIFICATION AS NECESSARY TO MEET CODE REQUIRREMfENTB AND/OR TO FACILITATE MECHANICAL/ELECTRICAL/PLUMBNG INSTALLATION AND /OR TO iNCORPORATE DESIGN lf'R E7MENTS. ANY INTENTION TO MODIFY THESE PLANS MAT BE APPROVED IN WRITING BY ARCH!TECTURAI- SERVICES. 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND INFOR•RATON IN THESE CONTRACT DOC4a'1ENTS. CONTRACTOR SHALL SURVEY THE PROJECT AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND ScOPE OF WORK W_LUDtNG BUT NOT LIMITED TO BUILDINGS, SITE AND SOIL BEARING CONDITIONS. b. ANY ERRORS, OMISSIONS OR INCONSISTENGE6 IN THESE CONTRACT DOCUMENTS OR THE ACTUAL SITE AND CONSTRUCTION CONDITIONS SHALL 15E BROUGHT TO THE ATTENTIONS OF ARC•1 ITECTUIRAL SERVICES. 1. EXTERIOR PLAN DIMENSIONS ARE TO FACE OF FOUNDATION WALLS AND /OR OUTSIDE FACE OF WALL SHEATHING. INTERIOR DIMENSIONS ARE TO FACE OF STUD TRAMMING. EXTERIOR WALLS ARE 4" THICK (3 -V2" FOR STUD FRAuMINS AND I,Z" FOR SHEATHING), INTERIOR WALLS ARE 3412" UNLESS NOTED OTHERWISE. 8, WINDOWS AS SECOND EGRES6 (SLEEPING AREAS) SHALL 15E MINIMUM 5.1 SQUARE FEET. THE MINIMUM NET CLEAR OPENING HEIGHT DIMENSION SHALL BE 24 INCHES AND THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20". THE SILL HEIGHT SMALL NOT BE MORE THAN 44 INCHES ABOVE FLOOR LEVEL. 3. SLIDING GLASS DOORS AND ALL GLAZED AREAS SUBJECT TO HUMAN IMPACT MUST BE SAFETY GLAZED. 0. BTAIRWAYB_ A. INTERIOR STAifaUAYS SHALL HAVE A MINMUM OF 6' -8" (FINISH TO FINISH) HEADROOM, 6 -1/4," MAXIMUM RISER 1 EIGHT AND 9' MINIMUM TREAD LENGTH. THE MNIMUM CLEAR VDTH OF A STAIRWAY SHALL BE 36 ". REFER TO PLANS FOR EXACT DIMENSIONS. B. HANDAILS: (HANDRAIL$ SHALL HAVE A HEIGHT OF 34- MEASURED VERTICALLY FROM THE NOSING OF THE TREAD AND SHALL 13E PROVIDED ON AT LEAST ONE SiDE OF THE STAIRWAY OF THREE OR MORE RISERS. THE HANDGRIP PORTION OF THE HANDRAILS SHALL NOT 15E MORE THAN 2 5/8 INCHES IN CROSS - SECTION DIMENSION AND HANDRAILS PROJECTING FROM A WALL SHALL HAVE A SPACE OF NOT LESS THAN ONE INCH BETWEEN THE WALL AND THE HANDRAIL. C. GUARDRAILS: PORCHES, BALCONIES OR RAISED FLOOR SURFACES LOCATED MORE THAN 30 INCHES ABOVE THE FLOOR OR GRADE BLOW SHALL HAVE GUARDRAILS OF 36 W-4-ES IN MEICsHT. OPEN SIDE OF STAIRS WITH A TOTAL RISE OF MORE THAN 30 INCHES ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDRAILS OF 34 W-WES N HEIGHT MEASURED VERTICALLY PROM THE NOSING OF T14E TREADS. HORIZONTAL SPACING BETWEEN THE VERTICAL M "5ER8 IN REQUIRED GilARDRAIL6 SHALL BE MAXIMUM OF FOUR INOICS AT THE NEAREST POINT BETWEEN THE MEMBERS. 11. APPROVED SMOKE DETECTORS SHALL BE LOCATED ON EVER" STORY OF THE DWELLING WIT, INCLUDING BASEMENTS. WHERE MORE THAN ONE IS REQIRED, ALL SHALL DE WIRED N SUCH A MANNER 60 THAT WHEN ONE M ACTUATED, ALL WALL BE ACTUATED. t2. FIREPLACE CiHI/NEY8 SHALL.. EXTEND AT LEAST TWO FEET HIGHER THAN ANY PORTION OF THE BUILDING WITHIN TEN FEET, BUT SMALL NOT BE LESS THAN THREE FEET ABOVE THE PONT WHERE THE CHIMNEY PA66ES TiHROUGH THE ROOF. 13, FIREPLACES SMALL BE INSTALLED ACCORDING THE MANUFACTURER'S SPECIFICATIOPIS. 14. NATURAL LIGHT AND VENTILATION MINIMUM REQUIRE LENTS A LIGHT AREA PER HABITABLE ROOM: 8X OF FLOOR AREA B. VENTILATION AREA PER ROOM: 4% OF FLOOR AREA 6. ALU1IN11 GUTTERS AND DOWNSPOUTS SHALL 15E PROVIDED AS REQUIRED TO PROVIDE WATER FLOW AWAY FRIOM IMMEDIATE BUILDING PERN'ETER. Ib, PROVIDE ATTIC ACCESS OF 22' X 30" (MINIMUM) TO ANY ATTiC SPACE WITH A 30" MINIMUM CLEAR HEIGHT. 11. ALL WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD CLA6SIFiCATtON OF NO GREATER THAN 200 AND MAXiMU I SM10KE DENSITY OF 460. FOOTING AND FOUNDATION NOTES OD 0 1. LOT SHALL BE PROdiDED WITH ADEQUATE POSITIVE DRRAiNAGE AWAT FROM FOUNDATION WALLS- cu 2. CONCRETE WORlr SHALL +-LAVE THE FOLLOWNG SPECIFIED ° COMip-RE58i✓E STRENGTH AT 28 DAYS PSI. W A BASEMENT WALLS AND FOUNDATION NOT EXPOSED z TO TINE WEATHER it PSI_' B. BASEMENT BLABS AND INTERIOR SLABS ON • CONCRETE SUBJECT TO FREEZING AND THAWING DURING ICONSTR.JGTION 6HAL, BE A'R- EN'R.4!NED iTEM5 C AND D ABOVE ARE REQUIRED TO BE A;R- ENTRAINED, TOTAL A!R CONTENT SHALL BE NOT LESS THAN 5% OR "MORE THAN lx_ 3. FLOOR SLABS SHALL BE NCy NAL 4 INC+-ES THICK - _CNGRETE WITH CONTROL JO!NTS SPACE✓ AT ;NTERVALS NO' "MORE THAN 30' -0" M EACH DIRE=TION CONTROL JOINTS M,4Y BE OMITTED WHEN 6 X 6 GlC to W1M. RE itFORC- NKs IS PROVIDED. PROVIDE 6 '11L. "OR APPROVED) VAPOR BARRIER WITH 6 INCH LAPPED JOINTS. VAPOR BARRIER MAC' BE OMITTED PROF? DET.:--HED GARAGES, DR'VE:�jATS WALKS, PATIOS AND OTHER R.A' WORK NOT LIKELY TO BE ENCLOSED AND HEATED AT .-I FUTURE DATE OR 15 ' THE BUILDING OFFiGiA_ BASED UPON LOCAL 817E COND;TIONS. 4. THE BOTTOM OF ALL FOOTINCs6 SHALL EXTEND TO FRO57 LINE. FOUNDATION WALLS SHALL EXTEND 8" (M NI"LiM) ABOVE FiN!SH GRADE ADJACENT TO FOUNDATIONS AT ALL POINTS. 5. PERIMETER INSIALATION ON GRADE SLAB CONDITION 5.ALL BE I -L/2" X 24' RIGID AND TO BE INSTALLED BY THE CONCRETE 5tlBCONTRACTORe 6 PERMETER FOUNDATION D*AiN5 SHALL BE INSTALLED AND LOCATED AT THE BUILDER'S DISCRETION ACCORDING TO LOCAL SITE ARID CODE CONDITIONS. DRAIN D15C44ARYGE SHALL CONFORM WITH APx*DlvOED SITE PLAN 1 CONCRETE ANCHOR BOLTS SHALL BE 117" DIAMETER BOLTS OR CODE APPROVED 16 GAIUGE ZINC COATED CLIPS (STRAPS) EMBEDDED IN CONCRETE BLOCK OR POURED IN PLACE CONCRETE WALLS (1" MINIMUM AT POURED CZ14CRE'E WALLS, 15' MINIMUM AT CM1J. WALLS) SPACED AT 4' -0" O.C. M,AX"JM-AND C" MAXIMUM FROM CORNERS. ANC.1 -NOR STRAPS MAY BE PROVIDED N LIEU OF BOLTS ABOVE WiTH SPACING AS RECOlt"11MIENDED BY MANFACTLWER AND ACCEPTED BY LOCAL CODE FLOOR PLATES AND SILLS TO BE SHIMMED LEVEL. USE METAL 6WI MS ONLY BELOW ALL BEAMS. e. SUMP PUMP TO BE INSTALLED AS REQUIRED AND LOCATED AT BUILDER'S DISCRETION 9. TOP COUJRSES OF CM11 FOUNDATION WALLS SHALL BE FILLED SOLID, INCLUDING THE COURBES DIRECTLY BELOW STEEL BEAMS OR CORBELLED CMI. 0. CONCRETE FOR"1L10R K TO BE ADEQUATELY TIED AND BRACED. FORMS ARE NOT TO BE STRIPPED, NOR BACKFiLL PLACED AGAINST THE WALL UNTIL THE WALL HAS SUFFICIENT STRENGTH OR WAS BEEN BRACED TO PRE'/ENT DAMAGE BY THE BACI�ILL. 11 CRALLL SPACES SHALL HAVE A MINIMUM CLEAR HEIGHT OF ia• AND AN ACCESS HOLE OF A MINIMUM OF 18" X 24 ". t2. EXTERIOR FOUNDATION WALLS OF MASONRY CONSTRUCTION ENCLOONG BASEMENTS SHALL- BE DA'IPPROOFED BY APPLYING NOT LE66 THAN 3/8 INCH OF PORTLAND CE MENU PARriNG TO THE WALL FROM FOOTING THE FINISH GRADE. THE PARGING SHALL BE COVERED 1.011+ A COAT OF AP'PROV1rD 51%MtNOUS MATERIAL APPLIED AT THE RECOMMENDED RATE. EXTERIOR FOUNDATION WALLS OF CONCRETE CONSTRUCTION ENCLOSING BASEMENTS SHALL BE DAMppROOFED BY APPLYING A MINMU'M OF ONE COAT OF APPROVED BlTum NOU6 MATERIAL TO THE WALL FROM THE FOOTING TO THE FINISH GRADE AT THE RECOMMENDED RATE. 13. BUILDING FOUNDATIONS ARE DESIGNED BASED ON AN A66U-ED SOIL BEARING CAPACITY OF 2000 PSF. ADDITIONAL ENGINEERING IS REQUIRED IF SOIL BEARING CAPACITY IS LESS THAN 2000 PAP. r STRUCTURAL NOTES L INTERIOR PARTITIONS SHALL BE 2 X 4 STUD CONSTRUCTION WITH V2' GYPSUM BOARD. tOCES8 OT14Ei XSE NOTED. BEARING WALLS SHALL HAVE STUD PLACEMENT 16' O.C. MAXIMUM. NON -LOAD BEARING INTERIOR PARTITIONS SHALL I',SE 24. OTC. MAXIMUM. MOISTURE RESISTANT GYPSUM BOARD SHALL BE PROVIDED AT ALL SHOWER AND BATH AREAS WITH SMOOTH, HARD AND NON- AD6ORBENT FINISHES. FN04 MATERIAL AND MOISTURE RE616TANT GYPSUM BOARD WITHN THE IMMEDIATE SHOWER AND BATH AREAS SHALL EXTEND b'-0" ABOVE FINISH FLOOR 2. ALL EXTERIOR WALLS SHALL 15E 6HEATHED WITH V2" 6HEATi4NG. METAL LET-IN BRACING SMALL BE INSTALLED PER CONSTRUCTION DOCUMENTS AND SHALL BE LET INTO THE TOP AND BOTTOM PLATES AND THE INTERVENING STUDS, PLACED AT NOT MORE THAN 60' NOR LESS THAN 45' FROM THE HORIZONTAL AND ATTACHED TO THE F2AMIWs IN CONPORRIMAJNCE WITH THE MANFACTUP&W6 SPECIFIGATIOPNB. 3. ALL BA6EME NT INTERIOR BEARING WALLS SHALL BE SHEATHED WiTH A MNIMAU'1 OF tr2" GYPSUM BOARD ON ONE SIDE. 4. THE MINIMUM GRADE AND ALLOWABLE 6TRRE66ES FOR 6TRUGTUMRAi_ MEMBERS ARE: A. STUDS SPF STUD GRADE OR BETTER Fb 650 P81 B. JOIST bYP 02, MCM, Fb 1400 P�J (REPETITIVE MEMBER U5E6) C. LVL LAMINATED BEAMS - t32 2923 PSI D. TRU66ES (ROOF AND FLOOR) • AS PER ENGINEERING REQUIREMENTS S. DESIGN LIVE LOAD! ARE BALCONIES (EXTERIOR) 60 L56 /5F DECKS 40 L.BS /SF GARAGES (PASSENGER C4 RS ONLY) 5@ L139/�F ATTICS (NO STORAGE WITH ROOF SLOPE NOT STEEPER THAN 3 N 12) ATTICS 'LI'MiTE: ATTIC STORAGE) 2@ -L9 /5 F DWELLING UNITS (EXCEPT SLEEPING ROOMS) 40 L56/ 5F SLEEPING ROC .5 40 1.0$'5E STAIRS 4A2 LS OF 6. OPENNGS BETWEEN GARAGE AND RESIDENCE SHALL BE EQUIPPED WiTH SOLID WOOD OR 20 MINUTE FIRE RATED 8. AL_ 71si1S5E5 ARE STOPPED AND CERTIFIED E3. A REG:5TERED ENGINEER AN% MEET Tcl "1APtFA : -JRER `t;N "TIM RE_0u4REMENT5. -1 LLt-lE!ER IN CONTACT WIT, GONCRETE AN; .OR _E55 THAN 8" FROM COIADE IS TO BE f'RESSUtRE TREATED C:✓JL" AN; ZFD,I 10 "E_ cOLLOI.UNG FLOOR SY 57EM5 AR3 OFFERS::; R_ErfR TO DRAWINGS AND /OR CU570MER SELECTION 5 -=c_ET POOQ SUBFLOOr2 r^ATE!R'AL. A. 3/4" TOKsUE AND GR✓ ./E PLYWOOD OR 055 `ORIENTED STRAND BOARD), CzLUED AND NAILED ON 2x4 O ENCz!NEEEIWs WOOD FLCR T/R✓55ES • 24 O.C. 11 PRO ✓!DE 2xb STRONCs5ACKS AS LOCATED ON RA" !LING F'L N5. !2. NO CiJTT;NC,. NOTCNIN!s OR "10D!FICA'ION BE MADE TO ANY TRt.95E6 WIT «GOUT Ti4E APPriO, /4 - OF ;R.Ci :TEG'UR4L SERVICES. !3. FIRESTOPPING SHALL BE PROV'DED TO G:T OFF ALL CONCEALED DRAFT OPEN!WCs5 (BOTH VERTICAL AND HOR'ZONTAL: AND TO FOB AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BE%EEN ATOP STORY AND THE ROOF SPACE. FiRE5TOPPINCs SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: A. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS INCLUDING FURRED 51DACE5. AT THE CEILING AT FLOOR LEVEL B. AT ALL !NTERr_ N CTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES 54K.H AS OCCUR AT SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC-.t C IN CONCEALED SPACES BETWEEN STAR STRINGERS AT THE TOP AND BOTTOt' OF THE RINt p. AT OPENINGS ARO;N I VENT, PIPES, Di4GT5, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL WITH NONCOMBUBTI BLE MATERIALS. EXCEPT AS PROVIDED IN ITEM D ABOVE, FIRESTOPPING SHALL CONSIST OF TWO INCH NOMINAL LUM3ER OR TWO THICKNESSES OF ONE INCH NOMINAL LUMBER WiTH BROKEN LAP JOINTS. THE INTEGRITY OF ALL FIIRESTOPS SHALL BE MAINTAINED. 14. DiR FTBTOPPING SHALL BE PROVIDED IN ALL FLOOR - CEILING ASSEMBLIES UNDER THE FOLLOWING, CIRGtI"ISTANCES: A CEILING 18 SUSPE 4IDED UNDER THE FLOOR FRAMINGt B. FLOOR FRAMING 18 CONSTRUCTED OF TRUSS -^r'PE OR OPEN WEB PERFORATED MEMBERS. IN FLOOR"CEILING ASSEMBLIES WHERE THE AREA IS GREATER THAN "0 SQUARE FEET, THE SPACE BETWEEN THE GEILNG MEMBRANES AND FLOOR SHALL BE DIVIDED INTO TWO OR MORE APPROXIMATELY EOIJAL AREAS WITH NO AREA GREATER THAN loom SQUARE FEET. DRAFTSTOPPiNG SHALL. BE PROVIDED PARALLEL TO THE MAiN FR.4`11N53 MEMBERS. DRAFTSTOPPiNG MATERIALS SHALL BE NOT LESS THAN 112 INCH Gi'PSU M BOARD, 318 NC-44 PLYWOOD, 3/8 INCH TYPE 2- M -W PARTICLE BOARD, OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. THE INTEGRITY Cr- ALL DRAFTSTOPS SHALL 15E MAINTAINED. 15. ALL M(AJIPLE 2 X HEADERS AND MULTIPLE LVL BEAMS TO BE K46S -tJE TOGETHER AT TOP AND BOTTOM INTO EACH ADJACENT MEMBER WITH ( MINMMUM) TWO LOWS OF VD NAILS • t2 W-44 O.G. I6. ALL BEAMS WRH FLITCH PLATES ARE TO 13E BOLTED TOGETHER WITH V2 INCH DIAMETWt !JOLTS AT 12 INCH OZ. STAGGERED TOP AND BOTTOM WITH TIUO BOLTS AT EACH END UINL-ES9 OTHERWISE NOTED, R. NOTCHES IN BEARING WALT STUDS SHALL NOT EXCEED 2511 OF THE STUID WIDTH AND NO HOLES ARE TO BE BORED GREATER THAN 40% OF THE STUD WIDTH. 18. NO HOLES OR NOtG1.01b ARE ALLOWED IN BEAMS W;TH000T THE APPROVAL OF ARCHITECTURAL 6ERVIC:ES. 1% TYPICAL ROOF GONSTRLUCTiON 16 TO BE 1/16 NCH ROOF SHEATHING (AMEIRICAN PLYWOOD ASSOCIATED RATED) WiTH IV FELT AND C MFbO 1TfON ROOF SHINGLES. 20. BALLOON FRA MINCs SPECI19ICATIONS: A. •f v d MAI 14 SIZE, SPECIES 4 SPACING MAXIMUM STUD HEIGHT (1) 2 X < OPF 42 • O.G. 10' -9 3/8" (1) 2 X 4 6PF 12 0 12' O.C. 11' -10 1/4' (2) 2 X 4 OPF 02 0 16' OZ. 13' -1" (2) 2 X 4 6PF 02 0 12' OZ. 14' -I1 I /4" (3) 2 X 4 6PF 02 0 16' Or. 1 5' -6 5/5" (3) 2 X 4 SPF 02 • Qb O.C. R. 7 X e. IIJAI 1 5 SIZE, SPECIES 4 SPACING MAXIMUM STUD HEIGHT (1) 2 X 6 SYP'2 • I6" O.C. ' -6" _ (1) 2 X 6 SYP 42 0 12" O.C. 21' -5 1/4" (1) 2 X b 61Tr 'I 0 16" OZ. !I) g M 0 " O 2L STEEL LINTELS SUPPORTING MASONRY VENEER ARE AS r__A I P11 Lt. LINTEL 5404EDULE HEIGHT OF VENEER Y THM 3 8" 16" 24" 32• SPA1412 ECG FtoCsREATER L 33x35x L 35x38 x L 39x35x k/-3-rvx3.bx L 35x35x 3 • , 2& 0295 5 0L35x35x L3.5x3sx L35x3Sx 35x L5x35x 3• 025 025 025 5 0325 16' -Il• L5x35x Lix3Sx Llx4x Llx4x I L®; 4" 03125 03125 0315 0315 22. AS REMIRRED B C Y LOCAL - CODE, BRICK VENEER !WHERE INDICATED ON PLANS) TO HAVE 22 GAUGE (MiNIMUIM) GORRSXsATED, GALVANIZED STEEL WALL TIES AT W6 INC" O.C. HORIZONTAL AND 24 INCH OTC. VERTICAL. °ROvIDE C�CNTINUOU6 BASE FLASM!NG WITH WEEP HOLES AT 4'0" OG. MAXIMUM. 23. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM SPECIFICATION A36. PIPE COLUMNS AND BASE /GAP PLATES ...At i Tn AAT" APFr_r- ir_ATInNS A5O! AND A53. MECHANICAL AND j � t PLUMBING NOTES 1, ALL MECHANICAL, ELECTRiCAL AND PLUMBING WORK SHALL COMPLY WITH STATE AND NATIONAL CODES, AS WELL AS, LOCAL GOVERNING CODES AND /OR ORDIN.V CES. 2 ALL PIPES, DUCTS, VENTS, W9QJ' NG AND CHASE?9 WHICH PENETRATE CEILINGS DIRECTLY BELOW T1RU68 OR ASSEMBLIES SHALL BE RR ESTOPRED. 3. ALL EXHAUST FANS SHALL BE VENT,E ', TO OUTSIDE Al. (EXCEPT) RANGE TOP. 4. BATHROOMS WITHOUT LUINDOWS SHALL HAVE AN VED MECHANICAL VENTILATION SYSTEM CAPABLE OF ItNG A CHANGE OF AIR EVERY TWELVE M!NUrE_S. BATHROOM EXHAUSTS SHALL BE VENTED DIRECTLY TO THE ODUT5ID 5. ATTIC VENTILATION: THE NET FREE vSNTILATING AREA SHALL BE NOT LESS THAN I TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE AREA MAY BE 1 TO 300, PROVIDED AT LEAST 50 PERCENT OF THE R'aEQJIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCA IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST THREE FEET ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. THE NET FREE CROSS - VENTILATION AREA MAY BE NOT LESS THAN i TO 300 OF THE AREA OF THE SPACE VENTILATED WHEN THE VAPOR BARRIER HAVING A TRANSM186ION RATE NOT EXCEEDING I PERM IS INSTALLED ON THE WARM SIDE OF THE (CEILING. AIR INFILTRATION NOTES 4� I. CONTRACTOR SHALL INSTALL FIBEfdsLA88 SILL SEALER BETWEEN ALL SILL PLATES AND TOP OF FOUNDATION WALL. 2, CONTRACTORS SHALL GLUE AND BEAL PLATES AT FLOOR AND CEILMCs, AND ALL WINDOW AND FLOOR FLANGES /JAMBS PRIOR TO AND DURING ERECTION. 3. ALL SHEATHING PENETRATIONS DURING CONSTRUCTION SHALL BE PATCHED AND REPAIRED ACC ORDIWj TO MAPR.FACTURER'S SPECIFICATIONS. INSULATION NOTES 1. THE FOLLOWING i #FORMATION DESCRIBES R`' LAND'5 MINIMUM ENE%aY CONVERSATION PACKAGE. INSULATION CONTRACTORS ARE HEREBY REQUIRED TO BID AND INSTALL INSULATION BY THIS SCHEDULE UNLESS INSTRUCTED IN WRITING BY RYLAIND TO DO OTHERWISE. 2. CEILN55 - R -38 I5LOUJN WOOL OR FIBERGLASS. 3- CATHEDRAL CEILINGS - R -30 BATT INSULATION WITH KRAFT FACE VAPOR BARRIER DOWN. 4. EXTERIOR WALLS - R -13 BATT iNSUiLATiON WiTH KRAFT FACE VAPOR BARRIER TO INSIDE. 5. EXTERIOR BASEMENT EXPOSED FOUNDATION WALLS - R O. 6. FLOORS AT OVERRHANG6 - R -19 BATT INSULATION U ATH KRAFT FACE VAPOR BARRIER UP. 1. FLOORS OF HABITABLE SPACE OVER GARAGE AND CRAILL SPACE - R -30 BATT INSULATION WITH KRAFT FACE VAPOR BARRIER TO INVDE. ELECTRICAL NOTES I 1. ALL ELECTRICAL MTALLATION SHALL MEET THE REC"IREMENTB OF THE NATIONAL ELECTRICAL CODE. ALL MATERIAL AND ECal"ENT SHALL BEAD THE LABEL OR APPROVAL OF THE UNDERWR1TEttb LADORATORMS, W- 2. ELECTRICAL CONTRACTOR SHALL, BEFORE CONSTRUUCTION, VERIFY SPACE REQUIRED FOR METER INSTALLATION AND SHALL NOTIFY GENERAL- CONTRACTOR AND ARCHITECT OF ANY PROBLEMS. 3. NO POINT ALONG FLOOR LiNE MEASURED HORIZONTALLY SHALL BE MORE THAN 6' -0" FROM A RECEPTACLE OUTLET. 4. VERIFY LOCATION OF ALL RECEPTACLES FOR APPLIANCES WITH MANUFACTURER'S SPECIFICATIONS. 5, GROUND FAULT INTERCEPTERS SMALL 15E PROVIDED AT ALL BATHROOM OUTLETS PER THE NATIONAL ELECTRICAL CODE. b. ALL SWITCHES TO BE 4' -b" ABOVE FINISH FLOOR TO CENTER LINE OF SWITCH LNNLESB OTHERWISE NOTED. 1. ALL CONVENIENCE OUTLETS ARE 1' -0" ABOVE FINISH FLOOR TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED. 8. ALL CONVENIENCE OUTLETS WITH SWITCHES TO 155E SWITCHED AT TOP ONLY. 3 ALL EXTERIOR WALL BRACKET FIXTURES TO BE 6' -0" ABOVE FINISH FLOOR TO CENTER LINE OF FIXTURE INDIANAPOLIS NOTES ! MONARCH SPECIFICATIONS: EXTERIOR WOOD TRIM 18 NOT PER PRINT. N AN EFFORT TO PROVIDE A LOWER MAINTENANCE EXTERIOR, WOOD TRiM IS USED ONLY AROUND GARAGE DOORS, FRONT DOORS, AND FRONT PORCHES. 2. PREMIER (HIGH -SWING) SPECIFICATIONS: (INCLUDING BRADLEY, BRIARWOOD, CARLISLE, GENEVA, HAMILTON, MANCHESTER, PRESTWICPC AND WESTON) EXTERIOR WOOD TRIM 18 NOT PER PRINT. ALL WOOD FASCIA RECEIVES WOOD SOFFIT. ONLY FRONT- FACING WOOD TRiM iS STANDARD. SIDES AND REAR TRIM IS ALUMINUM OR VINYL WRAPPED. (WOOD TRIM AT 'SIDES AND REAR'S AVAILABLE AS AN OPTION). CI Y- af c ce z! j U Y �1 u�X�2 aiU1� L j W_ LL U_ lu ul � r 711 -3 d) i d) ! in m j 0 QI Qi V4 04 mmmm u Q a a 0 dm��oL 30 71, 40 co C x go e T U g o 0 o 3 0 _ w O O rm z O 4 d) z F Z t�,s V a 0 O Y 3 R� x 'A w O O rm z O 4 d) z F Z t�,s V a 0 O