Loading...
HomeMy WebLinkAbout0298.95.28SUPERVISOR W O R K S H E E T FOUNDATION CHECKLIST BASEMENT PROJECT INFORMATION HOUSE NAME / ELEV. SET NUMBER PLAN / JOB NUMBER STANDARD OR REVERSED ANY NON -STD. CHANGES? FRONT OR SIDE LOAD STD., ENLARGED, OR FULL BSMT. (IN SET •) (OPT. 293) (OPT. 295) ALL SIDING OR BRICK FRONT (IN SET ") (OPT. 490) BSMT. WINDOW OPT. QTY. (MARK LOCATIONS) ON PRINT FIREPLACE OPT. NOTE: INSTALL BRICK LEDGE ON MASONRY FIREPLACES BUILDING PERMIT NUMBER I CHECKLIST MASONRY PRE -FAB SUMP PUMP LOCATION MARKED SUMP PUMP SLEEVE LOCATION MARKED - - - -_ _ -- MARK OUT ALL ►4AUNCHES NOT USED MARK IN FRONT PORC+ -+ WALL iF NOT ON PRINTS SEWER AND WATER SLEEVE LOCATIONS MARKED (3' W/ 4" SEWER COUPLER, 5'W/ 1 1/2" SLEEVE) HIGHLIGHT ALL BEAM POCKETS H-41C IGHT ALL PAD FOOTING LOCATIONS SLAB PROJECT INFORMATION HOUSE NAME / ELEV. [ i ^ tom: .1 STANDARD OR REVERSED ANY NON -STD. CHANGES? FRONT OR SIDE LOAD ALL SIDING OR BRICK FRONT iN SET 01 (OPT, 490 FIREPLACE OPT. NOTE: ' NSTALL BRICK LEDGE ON MASONRY F`x2E1'L,�CES BUILDING PERMIT NUMBER MASONRY PRE -FAB CHECKLIST OUT AL,. "A.:NCHE5 NO' _&I D "!ARC 'N FRONT F'OR� :r+ ,4A+ LS +F NOT ON PRINTS �Lo4'ER 5LEE VE LGG�; "'ON M.RCED ALL '++GKFNED SLAB FOOTINGS Ai..- PAD FOOTING _0GATiON5 DO NOT REMOVE BLUEPRINTS FROM JOBSITE 1. EXCAVATOR PLACE PRINT TUBE INSIDE OF EXCAVATION. 2. WALL CONTRACTOR LEAVE ON TOP OF WALL. III � FRAME PUNCH -OUT CHECK LIST 1. GARAGE GARAGE DOOR OPENING FRAMED TO CORRECT SIZE: 71' HT,, 8' OR I6' WIDE. GARAGE ATTIC ACCESS FRAMED TO CORRECT 51ZE AND LOCATION. NAILERS AT ALL CORNERS OF GARAGE AND CEILING. _zARAGE STEP FRAMED AND KICK PLATE UNDER DOOR BOW STUDS STRAP ANCHOR NAILED CORRECTLY LUMBER RACK BUILT t EXTRA MATERIAL STACKED ON 2. HOUSE CHECK FOR BOW STUDS GHECK FOR NAILERS MARK DOOR SWING DIRECTION AND SIZE CHECK FOR CASING ROOM (MIN. 2" ON EACH SIDE) CHECK. CENTERLINE OF KITCHEN WINDOW CHECK BULKHEAD DIMENSIONS CHECK WALL SIZES IN REL ATiON TO CABINET SPACE G«iECK VANIT`' SIZES IN RELATION TO IUALL SPACE CHECK vANITY DEPTH TO DOOR OPENING (MIN. 24 1/2 ") CHECK DOOR OPERATION AND INSTALLATION --- - - - - -- CHECK WINDOW OPERATION AND INSTALLATION C+4ECK BASEMENT STAIR AND 2nd FLOOR STAIR INSTALLATION PITCH RAIL WALL INSTALLED 142'; BELOW STRINGER ►- +ALF- ;L,41_L 42" FROM FLOOR AND SAME PITCH AS STAIRS (BOTH STAIRWAYS) �4ALF -WALL AT STAIRS PAST STRINGER 1 1/2" TUB PLATFORM BUILT CORRECTLY" 16 ir," HT., 39'' X 51" INSIDE -- - - -___ NO 5TJD5 * 24" O.G. AT GERAM'G AREAS. (16" O.G. MAX.) TUB BLOCKS INSTALLED AT CERAMIC AREAS. NAILERS FOR PIBERGLA55 TUBS INSTALLED MEASURE ' ✓INYL AREAS FOR SQUARE CB PANELS HAVE BLOCKS ON ENDS GNEGK FOR LOAD- BEAR!NG POINTS IN HOUSE AND PROPER LOAD TRANSFER STRAP ANCHORS SECURED IN µOUSE ---- - - - - -- CRAWL SPACE AND BASEMEN' CLEANED OUT --- - - - - -- STAIRWAY SHIMMED (MAX. 1/2" GAP EACH 51DE) !at AND 2na FLOORS LINE UP 'N S?A!R W1=-LL NO GAPS ABOVE STAIRWAY DRAFT5TOP 5T,41RWAY DROP CEILING DONE CORRECTLY (CHECK PRINTS) RISER INSTALLED AT TOP BASEMENT STEP HANDRAIL BLOCKS INSTALLED 32'` FROM' STAIR NOSING SAFETY BOOTS AND RAILS INSTALLED STRONGBACK IN FLOOR TRU55E5 BLOCKED AND NAILED TIGHT FLOOR SHEATHING NAILED PER SPEC.'b FALL PROTECTION INSTALLED A* STAIR WALL OPENINGS EYEBOLT AND ANGHOR POINT IN PLACE ALL DRAFT STOP INSTALLED ON CHASE AND BAND JOISTS ALL TY VECK STAPLED IN -PLACE EXTERIOR ALL +40LE6 PATCHED IN INSULATION BOARD ALL TRIM INSTALLED PER PRINT 3 1/2" RIP5 1/2 SHEATHING INSTALLED ON CORNERS ALL WINDOWS TAPED ON TOP AND GLUED ON FOUR SIDES ALL DOORS 'APED ABOVE PRINT HUNG ON NAIL IN GARAGE PERIMETER AND PANELS GLUED INTERIOR WALLS GLUED DOWN INTERIOR AND EXTERIOR WALLS NAILED INTO TRUSSES BELOW SE' TUBS INTO ROOM AND WIPE -OUT ATTIC ACCESS iNSTALLED IN HOUSE PER PRINT, 12" 51DES ALL WINDOWS iNSTALLED PER PRINT, ELEVATION AND STACK _____ 3/4" BLOCK UNDER CENTER OF DOUBLE WINDOWS