Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.4 Reflected Ceiling Plan.pdf
Project Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: RA I N H A I R S A L O N Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - S u i t e 1 1 3 41 W . C i t y C e n t e r D r i v e COPYRIGHT & OWNERSHIP OF DOCUMENTS N 1 2 3 4 DN MM MMM MMM MM M M MMMM MMMM MMMM MMMM TRASH DISP.DA3 Mtr R m 1A-2 ( A 1 4 8 ) StairSA4 ElevEA12 StairSA3 ElevEA6 StairSA5 StairSA1 ElevEA9ElevEA8 ElevEA1 StairSA2 StairSA6 ElevEA11 ELEVEA4ELEVEA5 ElevEA3 ElevEA2 ElevEA7 ElevEA10 KEY PLAN SUITE 113 PEDCOR DESIGN GROUP, L.L.C. A1.4 Reflected Ceiling Plan LES MC03/09/2012 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, ANDPEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, ORPORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007,2008, 2009, 2010, 2011 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA STATE RELEASE SET: 03/09/2012 ADDENDUM #1: 05/04/2012 ADDENDUM #2: 05/15/2012 ADDENDUM #3: 05/15/2012 ADDENDUM #4: 05/15/2012 N 1 1 1 3 3 3 28 27.5 27 26.5 M NM.5 1 A4.3 1 A4.3 1'-0"1'-0"2'-0"4'-0"2'-0"2'-4"6"3'- 0 " 6'- 0 " 6'- 0 " 6'- 0 " 6'- 0 " 6'- 0 " 6'- 0 " 41 ' - 1 0 3 / 8 " 4'-0"2'-9 1/4" 3' - 5 1 / 4 " 7'- 0 " 4'-9" 14 ' - 1 1 3 / 4 " 4'- 0 " 4' - 0 1 / 2 " 4' - 0 1 / 2 " 12'-0" 3'-10 1/2"8'-0 1/2"11'-9 7/8" 16'-0"2'-11 7/8"4'-0"1'-0" 12'-0" 7'-3"4'-9" 5' - 0 " 13 ' - 1 1 3 / 4 " 8'- 1 " 3' - 5 1 / 4 " 9'- 4 " 5'- 5 1 / 4 " 12 ' - 0 " 2' - 0 " 11'-3" 6'-0" 1' - 3 " 6'-0" 1' - 0 " 6' - 0 " 1'- 0 " 2' - 5 3 / 4 " 3'-9"6'-8 1/8"3'-6" 2'- 0 " 4'- 0 " 4' - 0 " 2' - 0 " 3'- 0 " 4' - 0 " 2' - 0 " 3'-0"11 1/2"4'-0"11 1/2"3'-0" 2' - 0 " 1'- 6 " 2' - 5 " 3' - 2 7 / 8 " 4' - 0 " 3'-10 1/2"3'-10 3/8" 7' - 2 7 / 8 " 12'-8 1/2" 12'-8 1/2" 9'-0" 9'-0" 10'-0" 9'-0" OPEN OPEN OPEN 10'-0" OPEN 10'-0" OPEN R 42'-6" R 4'-101/2" R 3'-111/2" R 3'-111/2" 3 A4.3 CP2 CP1 CP2 CP2 CP3 CP4 CP4 CP3 CP5 CP6 CP6 CP7 CP7 CP8 CP9 CP9 CP10 CP10 CP11 CP6 CP6 CP11 CP5 CP5CP3 CP5 CP5 CP3 CP2 CP6 CP4 CP7 CP11 D D D D D D D D D D D D D D D D D D D D D D D D D D B B B B B B BA E D1 D1 D1D1 D1 D1 C E D1 D1 D1 D1 F F F H H H D D G P7 P7 ACT1 ACT1 P8 P8 P6 P6 P6 P6 ACT2 G B P6 P8 D DD ACT1P8 F D 2 A4.3 ACCESS PANELS ARE TO BE PROVIDED IN NON-ACCESSIBLE CEILINGS AS NEEDED AND AT EXISTING EXTERIOR JUNCTION BOXES. PANELS ARE TO BE PAINTED TO MATCH THE ADJACENT CEILING SURFACE. COORDINATE LOCATION OF ACCESS PANELS WITH THE ARCHITECT. ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. GENERAL CEILING NOTES: CEILING PLAN NOTES: PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. EMERGENCY STROBES TO BE WHITE AND EMERGENCY LIGHT FIXTURES TO BE WHITE UNLESS NOTED OTHERWISE. COORDINATE IN THE FIELD WITH THE ARCHITECT AND TENANT. INSTALL ACOUSTICAL CEILING PANELS WITH GRAIN/TEXTURE RUNNING IN THE SAME DIRECTION UNLESS NOTED OTHERWISE. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. COORDINATE ALL SWITCHING AND LOCATIONS WITH THE TENANT AND ARCHITECT. LIGHTING TIMER IS TO BE PROVIDED TO MEETING ENERGY CODE. CP1 10. 9. 8. 7. 4. 5. 6. 3. 1. 2. HVAC DIFFUSERS AND GRILLES, FIRE SPRINKLERS ARE TO BE CENTERED WITHIN CEILING TILES. REFLECTED CEILING LEGEND: ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. SEE M-SERIES,E-SERIES AND P-SERIES SHEETS FOR MEP CONSULTANTS DRAWINGS. ALL QUESTIONS OR DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR IS TO VERIFY THERMOSTAT LOCATIONS WITH THE TENANT BEFORE PROCEEDING. CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE. HEIGHTS ARE NOTED ABOVE +2'-0" (TENANT CONCRETE SLAB). CP6 PROVIDE AND INSTALL DIMMER SWITCHES FOR LIGHT FIXTURES ON MOTION SENSORS AT THIS LOCATION. COORDINATE CIRCUITS AND SWITCHING WITH THE ARCHITECT. PROVIDE OPEN CEILING, ALL EXPOSED SURFACES TO BE PAINTED P6. PROVIDE SPIRAL DUCT, HARD PIPE CONDUIT FOR ALL WIRING, AND ALIGNMENT OF ALL VISIBLE ITEMS. PROVIDE ELECTRICAL FOR TENANT SUPPLIED ALARM SYSTEM AND SECURITY CAMERAS. LOCATIONS FOR CAMERAS ARE TO BE DETERMINED WITH THE TENANT ONCE A PROVIDER IS DETERMINED. SYSTEM IS TO BE CONTROLLED IN STORAGE 105. CP3 CP7 PROVIDE 2'x2' SUSPENDED ACOUSTICAL CEILING TO BE ACT1. PROVIDE 3 1/2" BATT INSULATION ABOVE ENTIRE AREA OF CEILING TILE. HOLD DOWN CLIPS ARE TO BE PROVIDED ON CEILNG TILES ADJACENT TO DIFFUSERS, EXHAUST AND RETURN AIR GRILLES. CP9 PROVIDE 2'-0" HIGH PAINTED DRYWALL CEILING WITH DOWNLIGHTS. SEE PLAN FOR PAINT COLORS AND LIGHTING LOCATIONS. HOLD BACK VISIBLE FRAMING 3'-0" AND CANTILEVER THE EDGE. SPRINKLER HEADS AND LINES ARE TO BE RAISED AS NEEDED TO MAINTAIN DESIRED CEILING HEIGHTS.CP4 ALARM SYSTEM AND SOUND SYSTEM ARE TO BE PROVIDED BY THE TENANT AND COORDINATED WITH THE CONSTRUCTION MANAGER. SPEAKERS ARE TO BE WIRELESS. 11. BLOCKING AND SUPPORTS ARE TO BE PROVIDED FOR ALL CEILING MOUNTED FIXTURES AS NEEDED. 12. EMERGENCY NIGHT LIGHTS. PROVIDE EMERGENCY LIGHTS AS REQUIRED AND DETERMINED BY MEP CONSULTANT. FIXTURES ARE TO BE: COOPER LIGHTING - SURE LITES - APEL. LIGHTING CONTROL. GYPSUM BOARD CEILING TO BE PAINTED. SEE FINISH SCHEDULE FOR PAINT SELECTIONS. INDICATION DUAL-LITE TO BE: COOPER LIGHTING - SURE LITES - ES. CEILING MOUNTED EXIT LIGHT W/ DIRECTION 2' X 2' SUSPENDED CEILING TO BE ACT1 OR ACT2. D RECESSED DOWN LIGHT TO BE: HALO - 1200 SERIES LED DOWNLIGHTS WITH 49X SERIES TRIM - ML712-8-35-TUNVD010-493WBS06. COLOR TEMPERATURE IS TO BE XXXX K. LIGHT FIXTURES ARE TO BE DIMMABLE. CHAIN HUNG LIGHT FIXTURE TO BE: COOPER LIGHTING - METALUX - DIF-232-UNV-EB81-U. FIXTURE TO BE MOUNTED AT 12'-0" AFF. LIGHT FIXTURES ARE TO BE ON OCCUPANCY SENSORS. E EXHAUST GRILLE IN CEILING FOR USE WITH BUILDING'S EXHAUST SYSTEM. TRACK HEAD TO BE: EUREKA - 1202-RCB-PAR30. TRACK IS TO BE SUSPENDED FROM OPEN CEILING WITH ALTHREAD AND UNISTRUT. TRACK AT DRYWALL CEILING IS TO BE ATTACHED TO THE CEILING. COLOR TEMPERATURE TO BE 3500K. TRACK AND FIXTURE ARE TO BE WHITE. TRACK TO BE MOUNTED AT 10'-0" AFF TO THE BOTTOM IN THE OPEN CEILING. F FIRE PROOFING IS TO BE REMOVED FROM THE DECK AND OTHER ITEMS IN OPEN CEILING AREAS THAT ARE NOT NEEDED TO BE FIRE PROOFED. 13. CEILING FINISHES: PAINT - SHERWIN WILLIAMS - URBANE BRONZE SW7048.P6 CP8 PROVIDE 2'x2' SUSPENDED ACOUSTICAL CEILING TO BE ACT2. CP5 PROVIDE EXHAUST GRILLE IN STYLING AREA, COLOR BAR AND RESTROOMS. CONNECT EXHAUST TO BUILDING SYSTEM. FIVE PERCENT (5%) ATTIC STOCK IS TO BE PROVIDE TO THE TENANT FOR ALL CEILING TILES. THESE ARE TO BE PROVIDED TO THE TENANT IN UNOPENED BOXES. 14. HVAC DIFFUSERS AND GRILLES ARE TO BE PAINTED TO MATCH THE ADJACENT CEILING.15. 16. PROVIDE AWNINGS. SEE DETAILS ON SHEET A4.4.CP10 CEILING CLOUD SUPPORTS FOR ALL ACOUSTICAL CLOUDS ARE NOT TO BE VISIBLE. 17.MEP CONSULTANT TO RUN THE NECESSARY CALCULATIONS TO DETERMINE THAT THE LIGHTING LAYOUT MEETS THE ENERGY CODE. IF IT DOES NOT PLEASE ADDRESS THIS WITH THE ARCHITECT AND THE TENANT TO REVISE LIGHT SELECTIONS AS NEEDED. 18.MEP CONSULTANT IS TO SUBMIT DRAWINGS SHOWING LOCATIONS OF ALL NECESSARY HORN STROBES, FIRE PULLS AND EMERGENCY LIGHTS. CP2 LIGHT FIXTURES IN BREAK 104, STORAGE 105, AND RESTROOM 107 ARE TO BE ON OCCUPANCY SENSORS. A B LINEAR LIGHT FIXTURE TO BE: FOCAL POINT - AVENUE C - FAVCS-FL-1T5H-1C -D - WHITE. SPECIFICATION GRADE FLUORESCENT LAMPS ARE TO BE USED (835K). COLOR TEMPERATURE IS TO BE 3500K. FIXTURE TO BE MOUNTED AT 10'-0" AFF. TO THE BOTTOM. LIGHT FIXTURE IS TO BE DIMMABLE. C WALL WASH LIGHT FIXTURE TO BE: FOCAL POINT - AVENUE A - FAVAS-NS-1T5HO-1C-SM - WHITE. FIXTURE IS TO HAVE THIN BLUE ACETATE THEATRICAL GEL ADDED.SPECIFICATION GRADE FLUORESCENT LAMPS ARE TO BE USED (835K). COLOR TEMPERATURE IS TO BE 3500K. FIXTURE TO BE MOUNTED TO THE DRYWALL CEILING. D1 RECESSED DOWN LIGHT TO BE: HALO - 900 SERIES - LED DOWNLIGHTS WITH 49X SERIES TRIM - ML709-8-35-ICAT120D-493WBS06. COLOR TEMPERATURE IS TO BE XXXX K. LIGHT FIXTURES ARE TO BE DIMMABLE. ACCENT PENDANT LIGHT TO BE: PRIMA LIGHTING - 5335-CG DEW DROP I. PENDANTS ARE TO BE MOUNTED TO 6'-6" AFF TO THE BOTTOM. PENDANTS ARE TO BE MOUNTED TO TRACK. TRACK TO BE: PRIMA LIGHTING 40-00-5335 AND MOUNTED TO THE DRYWALL CEILING. TRACK ABOVE RECEPTION 108 IS TO BE MOUNTED AT 10'-0" AFF AND ATTACHED TO THE DECK ABOVE. COLOR TEMPERATURE TO BE 3500K. WALL SCONCE TO BE: EUREKA - MOONSET CLASSIC - 3531-WH. MOUNT VERTICALLY. SPECIFICATION GRADE FLUORESCENT LAMPS ARE TO BE USED (835K). COLOR TEMPERATURE IS TO BE 3500K. WALL SCONCE TO BE MOUNTED AT 3'-8" AFF TO THE BOTTOM OF THE FIXTURE. LIGHT FIXTURE IS TO BE ON OCCUPANCY SENSOR. G H 19.CONTACT MELINDA DYKSTRA WITH SPECIFIED LIGHTING SYSTEMS REGARDING LIGHT FIXTURES. LINEAR LIGHT FIXTURE TO BE: FOCAL POINT - AVENUE D - FAVDS-PL-1T5H - WHITE. SPECIFICATION GRADE FLUORESCENT LAMPS ARE TO BE USED (835K). COLOR TEMPERATURE IS TO BE 3500K. FIXTURE TO BE MOUNTED AT 10'-0" AFF. TO THE BOTTOM. LIGHT FIXTURES IN MULTIPURPOSE 106 ROOM ARE TO BE DIMMABLE. LOCATE HVAC UNITS ABOVE ACCESSIBLE CEILING OR IN THE STORAGE ROOM.CP11 PAINT - SHERWIN WILLIAMS - BLUE NILE SW6776.P7 PAINT - SHERWIN WILLIAMS - CEILING BRIGHT WHITE SW7007.P8 ACT1 ACOUSTICAL CEILING - CEILUME. ACT2 ACOUSTICAL CEILING - DUNE TEGULAR. 20.CURVED DRYWALL BULKHEAD ABOVE STYLING AREA IS TO MATCH THE CURVE OF THE FLOORING TRANSITION BELOW. SCALE: 1/4" = 1'-0" 1 Reflected Ceiling Plan A1.4