Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.5 Electrical Finish Plan.pdf
Project Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: RA I N H A I R S A L O N Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - S u i t e 1 1 3 41 W . C i t y C e n t e r D r i v e COPYRIGHT & OWNERSHIP OF DOCUMENTS N 1 2 3 4 DN MM MMM MMM MM M M MMMM MMMM MMMM MMMM TRASH DISP.DA3 Mtr R m 1A-2 ( A 1 4 8 ) StairSA4 ElevEA12 StairSA3 ElevEA6 StairSA5 StairSA1 ElevEA9ElevEA8 ElevEA1 StairSA2 StairSA6 ElevEA11 ELEVEA4ELEVEA5 ElevEA3 ElevEA2 ElevEA7 ElevEA10 KEY PLAN SUITE 113 PEDCOR DESIGN GROUP, L.L.C. A1.5 Electrical Finish Plan LES MC03/09/2012 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, ANDPEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, ORPORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007,2008, 2009, 2010, 2011 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA STATE RELEASE SET: 03/09/2012 ADDENDUM #1: 05/04/2012 ADDENDUM #2: 05/15/2012 ADDENDUM #3: 05/15/2012 ADDENDUM #4: 05/15/2012 N 1 3 4 4 28 27.5 27 26.5 M NM.5 W RECEPTION 108 RETAIL 109 STYLING 101 COLOR 102 WASHING 103 BREAK 104 STORAGE 105 RESTROOM 107 MULTIPUPOSE 106 GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER,CONSTRUCTION MANAGER, AND/OR DESIGN- BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE UNLESS NOTED OTHERWISE. FLOOR OUTLET COVERS ARE TO BE GREY. COORDINATE IN THE FIELD WITH THE ARCHITECT AND TENANT. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. ALL OUTLETS ARE TO BE WHITE UNLESS NOTED OTHERWISE. COLORS AND LOCATIONS ARE TO BE VERIFIED IN THE FIELD. 6. 7. 5. 4. 3. 2. SOUND SYSTEM AND ALARM SYSTEM ARE TO BE CONTROLLED AT THIS LOCATION. CONSTRUCTION MANAGER IS TO COORDINATE INSTALLATION WITH THE TENANT. PROVIDE (2) OUTLETS AT THE BOTTOM ON THE PHONE BOARD. DUPLEX WALL OUTLET. D CABLE TV OUTLET. ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX, CONDUIT AND PULL STRING). +44"HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. EP1 EP2 LOCATION OF ELECTRICAL PANEL IN SERVICE CORRIDOR. PROVIDE LOCKING DOOR FOR PANEL. PROVIDE POWER SOURCE FOR WASHER/DRYER. WASHER/DRYER TO BE: XXX. CONSTRUCTION MANAGER IS TO INSTALL TENANT PROVIDED WASHER AND DRYER. EP3 EP4 8.ALL PENETRATIONS THROUGH THE DEMISING WALLS BETWEEN TENANTS AND BETWEEN THE TENANT AND THE SERVICE CORRIDOR NEED TO BE FIRE RATED. 9.FIRE ALARM SYSTEM SHALL BE COMPATIBLE AND TIED TO THE EXISTING BUILDING FIRE ALARM SYSTEM. EP5 EP6 PROVIDE POWER SOURCE FOR PEDICURE BOWL. BOWL TO BE: ETOPA - JADEN PEDICURE BENCH. CONSTRUCTION MANAGER IS TO INSTALL TENANT PROVIDED PEDICURE BOWL. EP7 PROVIDE POWER SOURCE FOR WATER HEATER AND WATER SOFTENER. 1. ELECTRICAL JUNCTION BOX PROVIDE POWER AND DATA AT THIS LOCATION FOR A TENANT SUPPLIED AND INSTALLED COPIER/PRINTER/FAX MACHINE. SURFACE MOUNTED CONDUIT IS TO BE RUN VERTICALLY. COORDINATE LOCATIONS OF ANY SURFACE CONDUIT IN THE FIELD WITH THE ARCHITECT. 10. DEDICATED QUAD WALL OUTLET. PROVIDE POWER SOURCE FOR WASHING SINKS. SINKS TO BE: XXX. CONSTRUCTION MANAGER IS TO INSTALL TENANT PROVIDED WASHING SINKS. EP8 NOT USED. D DEDICATED QUAD FLOOR OUTLET. EP9 ELECTRICAL OUTLETS ARE TO BE INSTALLED HORIZONTALLY ABOVE WORK SURFACE AND BELOW TRANSACTION TOP. OUTETS IN STAINLESS STEEL BACKSPLASH ARE TO HAVE STAINLESS STEEL COVER PLATES. DATA OUTLETS TO INCLUDE CONDUIT WITH PULL STRING TO WALL ABOVE THE PHONE BOARD.11. SEE M-SERIES,E-SERIES AND P-SERIES SHEETS FOR MEP CONSULTANTS DRAWINGS. ALL QUESTIONS OR DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. F W 10 ' - 1 0 " 2' - 4 " 15 ' - 7 1 / 2 " 2' - 1 " 10 ' - 2 " 10 " 4'-11 1/2"2'-2 1/2" 7' - 1 " 10 " 6'-0" 4' - 6 " 5' - 8 1 / 2 " 11 " EP1 EP2 EP3EP3EP3EP3 EP5 EP4 EP6 EP7 EP8EP8 EP9 EP9 EP9 EP9 EP9 EP5 EP9 +44" GFID+44" GFI GFI+42" GFIDD D D D D DD +42" GFI +39"+39" +39"+39" +39" +57" DD DD D 20A +42" GFI +42 +57" SCALE: 1/4" = 1'-0" 1 Electrical/Data Plan A1.5