Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SP.4 Specifications.pdf
Project Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: RA I N H A I R S A L O N Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - S u i t e 1 1 3 41 W . C i t y C e n t e r D r i v e COPYRIGHT & OWNERSHIP OF DOCUMENTS N 1 2 3 4 DN MM MMM MMM MM M M MMMM MMMM MMMM MMMM TRASH DISP.DA3 Mtr R m 1A-2 ( A 1 4 8 ) StairSA4 ElevEA12 StairSA3 ElevEA6 StairSA5 StairSA1 ElevEA9ElevEA8 ElevEA1 StairSA2 StairSA6 ElevEA11 ELEVEA4ELEVEA5 ElevEA3 ElevEA2 ElevEA7 ElevEA10 KEY PLAN SUITE 113 PEDCOR DESIGN GROUP, L.L.C. SP.4 Specifications LES MC03/09/2012 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, ANDPEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, ORPORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007,2008, 2009, 2010, 2011 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA STATE RELEASE SET: 03/09/2012 ADDENDUM #1: 05/04/2012 ADDENDUM #2: 05/15/2012 ADDENDUM #3: 05/15/2012 ADDENDUM #4: 05/15/2012 PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. CONTRACT EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND ALARMS THE ONWER SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS ADDITIONAL CHARGE TO THE PARTY AFFECTED. ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE OWNER THE OWNER SHALL PROTECT THE BUILDING PREMISES AND CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, LIGHT FIXTURES ( CATALOG CUTS ). HVAC DIFFUSERS, THERMOSTATS, GRILLES ( CATALOG CUTS AND PLANS ). PAINT ( 8" X 10" DRAW DOWN). FLOORING AND BASE ( COLOR SAMPLES ). SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6" X 6" ACOUSTICAL ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND "FURNISHED AND/OR INSTALLED" ITEMS. OWNER SHALL INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE THE OWNER SHALL COORDINATE AND SCHEDULE WORK BY OTHERS BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON-REGULAR WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN SUBMIT THE FOLLOWING INFORMATION: 1.8 1.7 1.6 AGENT. 1.5 .8 .7 .6 .5 PANEL ). .4 DOORS, FRAMES AND HARDWARE. .3 METAL FABRICATIONS..1 FOLLOWING ITEMS: 1.4 WORKMANSHIP. 1.3 1.2 1.1 GENERAL REQUIREMENTS1 MANUFACTURER'S RECOMMENDATIONS. 0.7 INTERPRETATION. FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI EQUIPMENT, PROVIDE FIRE-RETARDANT TREATED PLYWOOD PANELS, APA PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, STANDARDS. JURISDICTION. CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH PLYWOOD WITH FIRE-RETARDANT CHEMICALS TO COMPLY WITH AWPA FIRE-RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND C-D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32". CONTENT. .1 6.4 6.3 6.2 GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE WOOD AND PLASTIC REQUIRED TO COMPLETE WORK. METAL FABRICATIONS DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE RECORD SEPIA TO SERVE AS PART OF THE "AS-BUILT" SET. 6.1 6 5.1 5 2.11 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. OWNER SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED SERVICES IN USE. OWNER SHALL SECURELY CAP AND/OR VALVE- OWNER SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. EXIT STAIR DOORWAYS, ETC. CARPET MATS PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING IN SCOPE OF CONTRACT. 2.10 2.9 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS FINISHES. ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED ON EXISTING-CONSTRUCTION-TO-REMAIN, THOROUGHLY REMOVE DRAWINGS. BE INCLUDED. 2.7 2.8 2.5 2.4 "TREMCO ACRYLIC LATEX 834"; TREMCO, INC. "SONOLAC"; SONNEBORN BUILDING PRODUCTS "AC-20"; PECORA CORP. "CHEM-CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV. ACRYLIC-EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS "PROGLAZE WHITE"; TREMCO CORP. 8.1 DOORS AND WINDOWS8 .4 .3 .2 .1 SURFACES: 7.2 .5 .4 "863 #345 WHITE"; PECORA CORP. "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. "DOW CORNING 786"; DOW CORNING CORP. FIXTURES AND JOINTS IN TOILET ROOMS: ONE-PART MILDEW-RESISTANT SILICONE SEALANT - AT COUNTERS, GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL WIDTH NOT TO EXCEED 1/8 U.O.N. JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM STRAIGHT WITH NO DISTORTIONS. INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND .3 .2 .1 7.1 JOINT SEALERS7 OUTLETS. 6.11 6.10 6.9 CASEWORK: FURNISHINGS SEMI RECESSED, DUO-PANEL, FIELD PAINTED. BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES, FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO .1 12.1 12 10.1 YORKTOWNE CABINETS.3 MERILLAT INDUSTRIES, INC. .2 IMPERIAL CABINET CO., INC. .1 FOLLOWING: MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE LATEX TEXTURE COATING-SAND FINISH (WET AREAS) SPECIALTIES WITHOUT WRINKLES, GAPS OR OVERLAPS. WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLE PRECAST CONCRETE: 10 .2 .1 9.11 2. 1. A. 13. 2. SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6" FROM OUTSIDE CORNERS. ACCEPTABLE. KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT TEXTURE COATING. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX LATEX HOUSE PAINT PRIMER. PRIMER: 1 COAT #1502 WONDER-SHIELD ACRYLIC LATEX SATIN ENAMEL. FINISH: 2 COATS #35XX WONDER TONE ACYRLIC NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND RESPONSIBILITIES OF THE OWNER WHICH MAY BE PARAPHRASED THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1997 EDITION, 0.6 GOVERN THE WORK. 0.5 SPECIFIED CAPACITIES OF THE EQUIPMENT. 0.4 PROJECT. 0.3 RULES AND REGULATIONS. 0.2 CONTRACTOR'S RESPONSIBILITY. 10.1 WORKMANSHIP. 3.14 3.7 3.3 PROCEEDING WITH CONSTRUCTION. 3.2 AS FOLLOWS: 0.1 CONTRACT CONDITIONS0 SPECIFICATIONS AND GENERAL NOTES WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR WORK. EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE 2.3 2.2 2.1 DEMOLITION THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL REQUIREMENTS. EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT HOISTING, CARTING, ELEVATOR SERVICE, STANDARD AND OVERTIME 2 1.12 1.11 OPERATING FOR TEN DAYS. WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH OR EQUAL. SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF MANUFACTURED BY KNAPE & VOGT. HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS WITH POSITIVE STOP AND LOCKOUT POSITION, WITH DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES 6.8 6.7 .5 .4 MANUFACTURED BY STANLEY. MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH PULLS: MOCKETT DP32A. BY GRASS OR EQUAL. HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES" CABINET HARDWARE SCHEDULE: SEMI-EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP-28. (0.028" NOMINAL THICKNESS); EDGES: GP-28 (0.028" NOMINAL GP-50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP-28 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: .3 .2 .1 .3 .2 THICKNESS). .1 THE OWNER SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. 1.10 1.9 .4 .3 .2 AFFECT THE CONTRACT SUM AND CONTRACT TIME. ACCOMMODATE THE SUBSTITUTION. PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 400B FOR EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL NEMA LD 3 AND GP-50 (0.050" NOMINAL THICKNESS). COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH 6.6 SURFACES. .1 6.5 ACRYLIC LATEX SATIN ENAMEL FINISH: GYPSUM WALLBOARD: ACRYLIC LATEX SEMI-GLOSS ENAMEL FINISH: ACRYLIC LATEX SATIN ENAMEL FINISH: 1. A. 10. 2. 1. A. WOOD:8. 2. 1. A. CONCRETE:7. PRIMER-SEALER. PRIMER: 1 COAT #50801 WONDER TONES LATEX SEMI-GLOSS ENAMEL. FINISH: 2 COATS #83XX MIRROLAC-WB ARCYLIC PRIMER-SEALER. PRIMER: 1 COAT #51701 WONDER-PRIME LATEX LATEX SATIN ENAMEL. FINISH: 2 COATS #35XX WONDER TONES ACRYLIC PURPOSE PRIMER-SEALER. PRIMER: 1 COAT #51801 KILSTAIN-WB ALL- 9.2 MECHANICAL AND ELECTRICAL15/16 WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE "X" TAPERED REDUCIBLE ACRYLIC DRY FOG COATING. FINISH: 2 COATS #57601 UNI-GRIP-WB WATER1. ACRYLIC DRY FOG FLAT FINISH: REDUCIBLE ACRYLIC DRY FOG COATING FINISH: 2 COATS #57601 UNI-GRIP-WB WATER ACRYLIC DRY FOG FLAT FINISH: SEMI-GLOSS FINISH FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC LATEX PRIMER. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC ACYRLIC SEMI-GLOSS ENAMEL FINISH: SEMI-GLOSS ENAMEL. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC LATEX PRIMER. A. NON-FERROUS STRUCTURE:4. 1. A. FERROUS STRUCTURE:3. 2. 1. A. NON-FERROUS METAL:2. 2. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC ACRYLIC SEMI-GLOSS ENAMEL FINISH: FOR THE VARIOUS SUBSTRATES, AS INDICATED. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 1. A. FERROUS METAL:1. .1 REINSTALL SUCH ITEMS. 9.10 SURFACE VARIATION OF " IN 10 FEET, NON-CUMULATIVE. HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS 9.8 .2 .1 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN REFLECTED CEILING PLAN SHALL GOVERN. IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL RESILIENT FLOORING:9.7 CASED OPENING UNLESS NOTED OTHERWISE. 9.5 UNLESS NOTED OTHERWISE. .2 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM .1 DAMAGED OR SOILED TILES. 9.4 CRITERIA ESTABLISHED IN GA 214 AS FOLLOWS: COMPLY WITH ASTM C 840 STANDARD SPECIFICATION FOR APPLICATION 3. LEVEL 5 - GYPSUM WALLBOARD ON ALL FINISHED CEILINGS AND ALL COMMON AREA WALLS. LEVEL 4 - GYPSUM WALLBOARD ON INTERIOR WALLS FOR ALL TENANT SPACES. AND FINISHING OF GYPSUM BOARD; GA 214 RECOMMENDED LEVELS OF LEVEL 2 - GYPSUM WALLBOARD BEHIND AN APPLIED WALL COVERING, GYPSUM BOARD FINISH; AND GA 216-2000 APPLICATION AND FINISHING OF GYPSUM BOARD; PROVIDE GYPSUM WALLBOARD MINIMUM FINISH LEVELS MEETING THE 2. AND WALLS AND CEILINGS IN MECHANICAL AND EQUIPMENT ROOMS. LEVEL 1 - GYPSUM WALLBOARD PERMANENTLY CONCEALED FROM VIEW.1. B. DRYWALL FINISHING: 4. A. 15/16.0 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY JUNCTION BOXES ARE NOT PERMITTED. TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE. SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT OWNER SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. FLOOR SLAB DOES NOT VARY BY MORE THAN " IN 20'-0" NON- LIMITED TO APPLIANCES AND FILES, OWNER SHALL CONFIRM THAT FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. OWNER SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED EXISTING CONSTRUCTION AND WALL TYPES. SEE WALL LEGEND FOR SYMBOLS RELATED TO TO BOTTOM OF FINISHED CEILINGS. TO TOP OF FINISHED FLOORS. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. TO FINISHED FACE OF GYPSUM BOARD. DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: PROCEEDING WITH CONSTRUCTION. REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO OWNER TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND OBSERVE PRIOR TO ANY COMMENCEMENT OF "ROUGH-IN" LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO ELECTRICAL CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL PROVIDING PROPER ACCESS TO RECEPTACLES. SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD OUTLETS, UNLESS OTHERWISE NOTED. DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. OWNER SHALL DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS COORDINATE WITH OTHER CEILING COMPONENTS. SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A DESIGN/BUILD DRAWINGS FOR FIRE PROTECTION, MECHANICAL, ELECTRICAL AND OWNER IS TO PROVIDE A COMPLETE PACKAGE OF INSTALLATION AND INTER-SYSTEM COORDINATION OF MECHANICAL AND SHALL BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE DESIGN BUILD CONTRACTOR ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTIN AND HVAC) AND TENANT UNLESS NOTED OTHERWISE. GN.10 GN.9 CLOSE-IN OF WALLS. GN.8 GN.7 OBSERVATION. GN.6 WITH CONSTRUCTION. GN.5 OTHERWISE. GN.4 GN.3 D. C. B. A. GN.2 GN.1 GENERAL NOTESGN CONSTRUCTION. 15/16.13 FOR SPECIFIC LOCATION. 15/16.12 15/16.11 WHITE. 15/16.10 15/16.9 INSTALLATION SHALL OCCUR. 15/16.8 15/16.7 EQUIPMENT. 15/16.6 OWNER'S AGENT. 15/16.5 15/16.4 15/16.3 CERTIFIED ENGINEER. 15/16.2 ELECTRICAL SYSTEMS. 15/16.1 WALL CONSTRUCTION, MEP SHELL SPECIFICATIONS: IN ADDITION TO THE NOTES BELOW, THE PREVIOUSLY ISSUED SPECIFICATION FOR DVISIOIN 15 AND 16 SHALL BE APPLICABLE TO ALL WORK UNDER THESE CONTRACT DOCUMENTS. COPIES OF THESE SPECIFICATIONS ARE AVAILABLE FROM THE ARCHITECT (PEDCOR DESIGN GROUP) AND THE OWNER. PROVIDE SHOP DRAWINGS FOR OWNER'S APPROVAL PRIOR TO FABRICATION. INTERIOR DOOR FRAMES: PROVIDE HOLLOW METAL FRAME UNLESS NOTED OTHERWISE. FRAMES TO BE PREPPED AND PAINTED IN THE FIELD. COLOR SPECIFIED BY DESIGNER. NATURAL BIRCH, ROTARY CUT. PLY PC-7 PARTICLE BOARD SOLID CORE. WOOD VENEER FACES: INTERIOR DOORS: AWI SECTION 1300 "PREMIUM GRADE" PRE-MACHINED 7-8.2 .1 MANUFACTURER'S STANDARD FACTORY PRIMED. COLOR APPLIED IN THE FIELD. COLOR TO BE SELECTED BY THE ARCHITECT. .2 WARRANTY: LIFETIME WARRANTY ON ALL ARCHITECTURAL FLUSH WOOD DOORS, INCLUDING THOSE DOORS WITH VIEW PANELS AND LOUVERS. PROVIDE DRAFT COPY OF WARRANTY WITH SUBMITTALS. GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. REQUIREMENTS FOR HEAT-STRENGTHENED GLASS. GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 9.1 FINISHES9 8.4 AND LOCKSETS. SEE DOOR SCHEDULE ON A1.2. 8.3 DOOR HARDWARE: PROVIDE MEDIUM DUTY WITH ADA LEVER HANDLE LATCH PLUMBING FIXTURES ( CATALOG CUTS AND PLANS ). .9 FIRE EXTINGUISHERS ( CATALOG CUTS ). WALL FINISHES ( COLOR SAMPLES )..8 .7 .9 COLD FORMED METAL FRAMING..2 .10 ELECTRICAL PLAN. AWNING (PLAN & CATALOG CUT). .11 FIRE PROTECTION PLAN..12