Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.4 REFLECTED CEILING PLAN.PDF
Project Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: OF F I C E S P A C E Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r 41 W . C i t y C e n t e r D r i v e COPYRIGHT & OWNERSHIP OF DOCUMENTS Su i t e s 7 0 , 7 4 , 7 6 N 19 R @ 6 2 5 / 3 2 " = 1 0 ' - 8 3 / 4 " 18 T @ 1 1 2 9 / 6 4 " = 1 7 ' - 2 3 / 6 4 " UP SCALE: 1/128"= 1'-0" KEY PLAN SUITES 70, 74, 76 PEDCOR DESIGN GROUP, L.L.C. A1.4 REFLECTED CEILING PLAN AJR MC07/27/2012 STATE RELEASE SET: 07/27/2012 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL ANDUNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, ANDPEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, ORPORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2012JAMES R. STUTZMAN, AIA, Carmel, Indiana. N ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. GENERAL CEILING NOTES: CEILING PLAN NOTES: PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. EMERGENCY STROBES TO BE WHITE AND EMERGENCY LIGHT FIXTURES TO BE WHITE UNLESS NOTED OTHERWISE. COORDINATE IN THE FIELD WITH THE ARCHITECT AND TENANT. INSTALL ACOUSTICAL CEILING PANELS WITH GRAIN/TEXTURE RUNNING IN THE SAME DIRECTION UNLESS NOTED OTHERWISE. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. COORDINATE ALL SWITCHING AND LOCATIONS WITH THE TENANT AND ARCHITECT. LIGHTING TIMER IS TO BE PROVIDED TO MEETING ENERGY CODE. CP1 11. 10. 9. 8. 5. 6. 7. 4. 1. 2. 3. HVAC DIFFUSERS AND GRILLES, FIRE SPRINKLERS ARE TO BE CENTERED WITHIN CEILING TILES. REFLECTED CEILING LEGEND: ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE. PROVIDE AND INSTALL TIMER CONTROL SYSTEM AT THIS LOCATION. ALL LIGHTS NOT CONTROLLED WITH OCCUPANCY SENSORS ARE TO BE CONTROLLED ON THE TIMER. COORDINATE CIRCUITS AND SWITCHING WITH THE ARCHITECT. PROVIDE OPEN CEILING, ALL EXPOSED SURFACES TO BE UNFINISHED. PROVIDE SPIRAL DUCT, HARD PIPE CONDUIT FOR ALL WIRING, AND ALIGNMENT OF ALL VISIBLE ITEMS. CP3 CP4 12. BLOCKING AND SUPPORTS ARE TO BE PROVIDED FOR ALL CEILING MOUNTED FIXTURES AS NEEDED. 13. EMERGENCY NIGHT LIGHTS. PROVIDE EMERGENCY LIGHTS AS REQUIRED AND DETERMINED BY MEP CONSULTANT. FIXTURES ARE TO BE: MERCURY LIGHTING, MER-R1. MOTION SENSOR. INDICATION DUAL-LITE TO BE: MERCURY LIGHTING MER-ELXTE OR EQUAL. CEILING MOUNTED EXIT LIGHT W/ DIRECTION 2' X 2' SUSPENDED CEILING TO BE: ARMSTRONG, 2'X2' DUNE SQUARE LAY-IN, W/ PRELUDE XL 15/16" GRID. EXHAUST GRILLE IN CEILING FOR USE WITH BUILDING'S EXHAUST SYSTEM. FIRE PROOFING IS TO BE REMOVED FROM THE DECK AND OTHER ITEMS IN OPEN CEILING AREAS THAT ARE NOT NEEDED TO BE FIRE PROOFED. 14. PROVIDE EXHAUST GRILLE IN RESTROOMS. CONNECT EXHAUST TO BUILDING SYSTEM. 15. HVAC DIFFUSERS AND GRILLES ARE TO BE UNFINISHED. 16. MEP CONSULTANT TO RUN THE NECESSARY CALCULATIONS TO DETERMINE THAT THE LIGHTING LAYOUT MEETS THE ENERGY CODE. IF IT DOES NOT PLEASE ADDRESS THIS WITH THE ARCHITECT AND THE TENANT TO REVISE LIGHT SELECTIONS AS NEEDED. MEP CONSULTANT IS TO SUBMIT DRAWINGS SHOWING LOCATIONS OF ALL NECESSARY HORN STROBES, FIRE PULLS AND EMERGENCY LIGHTS. CP2 LIGHT FIXTURES TO BE ON OCCUPANCY SENSORS. A LINEAR LIGHT FIXTURE TO BE: MERCURY LIGHTING, MIE6-2-32-OCT-8T-10%-ELB-UNI-TILW- VH OR EQUAL. MOUNT AT 8'-0" TO BOTTOM OF FIXTURE. ALL LIGHT FIXTURES TO BE 3500K COLOR TEMPERATURE. B 2'X2' FLUORESCENT FIXTURE TO BE: MERCURY LIGHTING, 54E-232-OCT-U6-9-ELB-UNI OR EQUAL. EXISTING HVAC HEAT PUMP UNITS TO REMAIN WITH NO DISTRIBUTION ADDED.CP5 ALTERNATE 5: PROVIDE DUCT FROM ONE (1) HVAC HEAT PUMP UNITS TO SUPPLY PRIVATE OFFICE. CP6 M ADD DRYWALL TO EXISTING SOFFIT ALONG STOREFRONT WINDOWS. SOFFIT TO BE TAPED, SPACKLED, SANDED SMOOTH, WITH ONE (1) COAT OF PRIMER. CP7 PROVIDE SEPARATE TIMER ON CIRCUIT FOR WINDOW DISPLAY LIGHTS.CP8 C RECESSED DOWNLIGHTS TO BE: NORA LIGHTING NH-26Q, NTA-97 W/ 100W A19 LAMP OR EQUAL. 19 R @ 6 2 5 / 3 2 " = 1 0 ' - 8 3 / 4 " 18 T @ 1 1 2 9 / 6 4 " = 1 7 ' - 2 3 / 6 4 " UP L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L LLL L L L L L L L 8'-0" 8'-0" OPEN OPEN OPEN OPEN OPEN OPEN OPENOPEN FLOOR ACCESS COVER CP1 CP1 CP2 CP2 CP3 CP3 CP4 CP4 CP4 CP4 CP4 CP5 CP5 CP2 CP4 CP6 CP2 CP2 CP2 CP7 CP8 CP7 CP8 A A A A A A A A AA A A A A B B A A ***COORDINATE TENANT WORK FOR RESTROOM, IN FLOOR ELECTRICAL, ETC. A A AAA A A A A A A A M 24.1 24 23.1 23 22 21.9 21.5 21.4 20 21 23.6 25 24.1 24 23.1 23 22 21.9 21.5 21.4 20 21 23.6 25 Q R SR.1 R.2 R.3 R.5 R.6Q.2 Q.5P.5 Q R SR.1 R.2 R.3 R.5 R.6Q.2 Q.5P.5 SCALE: 1/8" = 1'-0" 1 REFLECTED CEILING PLAN A1.4