Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.5 ELEC_DATA PLAN.PDF
Project Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: OF F I C E S P A C E Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r 41 W . C i t y C e n t e r D r i v e COPYRIGHT & OWNERSHIP OF DOCUMENTS Su i t e s 7 0 , 7 4 , 7 6 N 19 R @ 6 2 5 / 3 2 " = 1 0 ' - 8 3 / 4 " 18 T @ 1 1 2 9 / 6 4 " = 1 7 ' - 2 3 / 6 4 " UP SCALE: 1/128"= 1'-0" KEY PLAN SUITES 70, 74, 76 PEDCOR DESIGN GROUP, L.L.C. A1.5 ELEC/DATA PLAN AJR MC07/27/2012 STATE RELEASE SET: 07/27/2012 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL ANDUNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, ANDPEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, ORPORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2012JAMES R. STUTZMAN, AIA, Carmel, Indiana. N GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY PEDCOR IT FOR SUITES 74 AND 76. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER,CONSTRUCTION MANAGER, AND/OR DESIGN- BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE UNLESS NOTED OTHERWISE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. ALL OUTLETS ARE TO BE WHITE UNLESS NOTED OTHERWISE. 7. 8. 6. 5. 4. 3. DUPLEX WALL OUTLET. D CABLE TV OUTLET. ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX, CONDUIT AND PULL STRING). +44"HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. EP1 EP2 LOCATION OF ELECTRICAL PANEL IN SERVICE CORRIDOR. PROVIDE LOCKING DOOR FOR PANEL. PROVIDE DATA OUTLET WITH CONDUIT AND WIRING TO CONNECT COPY/PRINTER TO THREE (3) LOCATIONS IN SUITE 74. EP3 EP4 9.ALL PENETRATIONS THROUGH THE DEMISING WALLS BETWEEN TENANTS AND BETWEEN THE TENANT AND THE SERVICE CORRIDOR NEED TO BE FIRE RATED. 10.FIRE ALARM SYSTEM SHALL BE COMPATIBLE AND TIED TO THE EXISTING BUILDING FIRE ALARM SYSTEM. EP5 EP6 REMOVE FURNITURE PANEL SYSTEM HARD-WIRED POWER SUPPLY FROM EXISTING MARKETING OFFICE AND INSTALL AT THIS LOCATION. PROVIDE WALL MOUNTED ELECTRICAL/DATA OUTLETS AND CONDUIT AT EXPOSED, UNFINISHED WALL LOCATIONS. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. 1. 2.ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES.ELECTRICAL JUNCTION BOX SURFACE MOUNTED CONDUIT IS TO BE RUN VERTICALLY. COORDINATE LOCATIONS OF ANY SURFACE CONDUIT IN THE FIELD WITH THE ARCHITECT. 11. DEDICATED QUAD WALL OUTLET. PEDCOR IT TO PROVIDE VOICE AND DATA WIRING TO TWO (2) WORKSTATIONS. PROVIDE POWER FOR BASEBOARD HEATERS AT STOREFRONT. HEATERS ARE TO BE PROVIDED AS PART OF THE VANILLA BOX. HEATERS ARE TO MATCH BUILDING STANDARD AND ARE TO HAVE FILLER PANELS SO THAT HEATERS EXTEND THE FULL WIDTH OF THE STOREFRONT. D DEDICATED QUAD FLOOR OUTLET. DATA OUTLETS TO INCLUDE CONDUIT WITH PULL STRING TO WALL ABOVE THE PHONE BOARD.12. 19 R @ 6 2 5 / 3 2 " = 1 0 ' - 8 3 / 4 " 18 T @ 1 1 2 9 / 6 4 " = 1 7 ' - 2 3 / 6 4 " UP TACK BOARDS EP1 EP1 EP2 EP3 EP4 EP5 EP5 EP5 EP5 EP5 EP6 EP6 REST ROOM 105 REST ROOM 104 SUITE 76 103 OFFICE 102 48 " 48 " LA T . F I L E BE L O W 42 " 24 " LA T . F I L E BE L O W 42 " 42 "42" PED. BELOW 42" PED. BELOW LAT. FILE GFI SUITE 74 101 SUITE 70 100 RA M P RA M P RAMP SERVICE CORRIDOR 106 GFI SERV. CORR. 107 SERV. CORR. 108 SERV. CORR. 109 ***COORDINATE TENANT WORK FOR RESTROOM, IN FLOOR ELECTRICAL, ETC. STOR. CLO. 1 STOR. CLO. 2 STOR. CLO. 3 STOR. CLO.4 STOR.CLO.5 STOR.CLO.6 STOR.CLO.7 STOR.CLO.9 STOR.CLO.8 STOR. CLO. 10 STOR.CLO.11 24.1 24 23.1 23 22 21.9 21.5 21.4 20 21 23.6 25 24.1 24 23.1 23 22 21.9 21.5 21.4 20 21 23.6 25 Q R SR.1 R.2 R.3 R.5 R.6Q.2 Q.5P.5 Q R SR.1 R.2 R.3 R.5 R.6Q.2 Q.5P.5 SCALE: 1/8" = 1'-0" 1 ELECTRICAL/DATA PLAN A1.5