HomeMy WebLinkAbout1034.95.2PARTIAL SITE PLAN u METAL TRACK -� BRACE WALL TO 5TRUGTURE ABOVE A5 REQUIRED �- WIRE HANGER 5U5PENDED ACOU5TICAL CEILING 5/8" DRYWALL TO BOTTOM OF DECK ABOVE O VACANT (FUTURE) I ATM LOBBY 3 5/8" 20 6A. METAL 5TUD5 TO BOTTOM OF DECK ABOVE O Lu X to ACOU5TIC BATT I N5ULATI ON METAL TRACK,,, I 11 1 i- VINYL BASE FIN15H FLOOR LINE TYP. WALL SECTION 5GALE: 1/2" = 1' -0" HVAO 6FN- � NOTE5: ALL EXISTING DUCT RUNS, HVAC EQUIPMENT AND NECESSARY PARTS TO REMAIN IN PLACE UNLESS CONTRACTOR DETERMINES IT IS NECESSARY TO REPLACE. FIT AND QUANTITY OF THE DUCT RUNS, HVAC EQUIPMENT, THE VARIOUS NECESSARY PARTS AND MATERIALS TO MAKE A COMPLETE AND FINISHED JOB, SHALL BE VERIFIED AND COORDINATED PRIOR TO THE START OF CONSTRUCTION AND ARE THE EXCLUSIVE RESPONSIBILITY OF THE HVAC CONTRACTOR. THE ENTIRE HVAC SHALL BE INSTALLED ACCORDING TO ALL APPLICABLE LOCAL, STATE OR FEDERAL CODES. ALL FIXTURES, EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURE'S SUGGESTED INSTALLATION REQUIREMENTS AND IN A NEAT AND WORKMANSHIP LIKE MANNER. THE HVAC CONTRACTOR IS RESPONSIBLE FOR THE START UP AND BALANCING OF THE ENTIRE HVAC SYSTEM, FURNISHING OPERATING AND MAINTENANCE INSTRUCTIONS, AND A ONE YEAR GUARANTEE. DUCTWORK SHOWN IS DIAGRAMMATIC AND MUST BE FIELD VERIFIED FOR EXACT ROUTING. ALL RECTANGULAR DUCTWORK WILL BE WRAPPED WITH 1" DUCT WRAP FOIL INSULATION. ALL ROUND PIPE TO BE FLEXIBLE INSULATED VINYL COATED DUCT, 7 MAXIMUM LENGTH. CEILING DIFFUSERS 4 -WAY BLOW (NECK SIZE VARIES). RETURN AIR GRILLES AND TRANSFER GRILLES TO BE 1/2- X 1/2- PLASTIC EGGCRATE. HVAC PLAN SCALE: I/8" = 1' -0" ELECTRIC NOTES I. FIT AND QUANTITY OF THE WIRING, ELECTRICAL EQUIPMENT, THE VARIOUS NECESSARY PARTS AND MATERIALS TO MAKE A COMPLETE AND FINISHED JOB SHALL BE VERIFIED AND COORDINATED PRIOR TO START OF CONSTRUCTION AND ARE THE EXCLUSIVE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 2. THE ENTIRE ELECTRICAL SHALL BE INSTALLED ACCORDING TO ALL APPLICABLE LOCAL, STATE OR FEDERAL CODES. 3. ALL FIXTURES, EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S SUGGESTED INSTALLATION REQUIREMENTS IN A NEAT AND WORKMANSHIP LIKE MANNER. 4. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR THE START UP OF THE ENTIRE ELECTRICAL SYSTEMS, FURNISHING OPERATING AND MAINTENANCE INSTRUCTIONS, AND A ONE YEAR GUARANTEE. 5. ALL ELECTRICAL EQUIPMENT SHALL HAVE "UL" LABELS. 6. WIRING DEVICES TO BE SPECIFICATION GRADE. -7. ELECTRICAL SHOWN IS DIAGRAMMATIC AND MUST BE FIELD VERIFIED FOR EXACT ROUTING. 8. TEMPERATURE CONTROL WIRING WILL BE COMPLETED BY THE MECHANICAL CONTRACTOR. Q. ALL WIRE SHALL BE COPPER, MINIMUM SIZE #12 AWG. ALL CONDUCTORS SHALL HAVE TYPE "THHN" INSULATION. CONDUCTORS jf10 AND SMALLER MAY BE SOLID. 10. FURNISH AND INSTALL A BREAKER PANEL AS MANUFACTURED BY SQUARE D OR ITE. INSTALL PANEL SO TOP BREAKER IS NO HIGHER THAN 6'- 0" A.F.F. II. FURNISH AND INSTALL TYPEWRITTEN DIRECTORY. IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. 12. CONDUIT IN FINISHED AREA TO BE CONCEALED TYPE EMT OR AC ARMOUR CABLE AS PERMITTED BY CODE. 13. ALL UNDERFLOOR CONDUITS WILL BE P.V.C. 14. ALL SWITCHES TO BE RATED 20 AMP., 125 VOLT AND SHALL BE MOUNTED 4' -6" A.F.F., UNLESS NOTED OTHERWISE. 15. ALL RECEPTACLES TO BE 15 AMP., 125 VOLT, GROUNDING TYPE AND SHALL BE MOUNTED V -4" A.F.F., UNLESS NOTED OTHERWISE. 16. LIGHTING FIXTURES TO BE FURNISHED AND INSTALLED COMPLETE WITH LAMPS AS DETAILED ON THE PLANS AND FIXTURE SCHEDULE. SEE THE REFLECTED CEILING PLAN FOR THE EXACT LOCATION OF THE CEILING GRID, UGHT FIXTURES, ETC. 17. SEE THE ELECTRICAL DRAWINGS FOR THE FIXTURE SCHEDULE, NOTES AND OTHER SPECIFICATION REQUIREMENTS. 18. LIGHT AND POWER PANEL SHALL BE A SIZE OF 120/208 VOLTS, 3 PHASE, 4 WIRE 100 AMP MAIN LUG, 100 AMPS MAIN BREAKER. EXISTING WIRE AND CONDUIT MAY BE REUSED IF LARGE ENOUGH AND IN PERFECT CONDITION. ALL BRANCH CIRCUITS SHALL BE AT LEAST 12 GA. THW. PROVIDE DISCONNECT OR CORD AND RECEPTACLE FOR EACH PIECE OF EQUIPMENT. VERIFY TENANT'S ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION. ELECTRICAL PLAN SCALE: 1/8" = 1' -0" SYMBOLS ® EXIT LIGHT �D V EMERGENCY LIGHT OV ELEC WATER HEATERS ❑J JUNCTION BOX 120 VOLT DUPLEX OUTLETS b TELEPHONE CHASE 5 SINGLE POLE SWITCH ® HVAC DIFFUSER �Q 2X4 FLUORESCENT FIXTURE EXISTING 3V G 5ERVI6E 1201208 4# 500MGM 0 / EXISTING MAIN BRK'R GT CABINET E METER------ ETER 120/208v I OOA NOTE - VERIFY ALL A5PECT5 OF EXI5TING 5ERVIGE W/ UTILITY CO. PRIOR TO BIDDING, INCLUDE ALL COA5T5. GROUNDING NOTE - GROUND TO BE I' ¢c 10' GROUNDING ELECTRODE (COPPER GLAD) W 1/0 GROUNDING ELECTRODE CONDUCTOR FROM THE 5ERVIGE ENTRANCE EQUIPMENT TO THE GROUNDING ELECTRODE. AL50 PROVIDE 1/0 TO STREET SIDE OF WATER. MAIN W/ 1/0 JJMPER AROUND WATERMAIN. POWER RI 5ER D I AORAM a EXI5TIN6 FURNACE TO REMAIN EXISTING CONG. BLOCK WALL (TO REMAIN) EXI5TIN6 TENANT WALL (TO REMAIN) NEW 3 5/8" METAL STUD WALL TO ROOF DECK ABOVE 18' -Q" m o ATM LOBBY CARPET EX15T. STORE FRONT (TO REMAIN) FLOOR PLAN SCALE: 1/8" = 1' -0" CONSTRUCTION NOTES X� _s I. DIMENSIONS ARE TAKEN FROM FACE OF NEW ROUGH STUD WALLS, AS SHOWN, AND FACE OF EXISTING FINISHED WALLS. 2. WALLS ARE A NOMINAL 12' -0" HIGH (VERIFY) AND SHALL BE 3 5/8" METAL STUDS AT 24" O.C. WITH PAINTED 5/8" GYPSUM BOARD ON BOTH SIDES FROM FLOOR TO CEILING WITH 4" VINYL BASE, UNLESS INDICATED OTHERWISE. (INTERIOR FINISHES TO BE SELECTED BY OWNER). 3. PROVIDE NECESSARY BLOCKING AND SUPPORT FOR ITEMS SECURED TO THE STUD WALLS. 4. ALL NEW DOOR JAMBS, HINGE EDGE OF DOOR, ARE LOCATED 6" FROM FACE OF ROUGH STUD. 5. NEW DOOR OPENINGS TO CONSIST OF 3' -0" X 1 3/4" SOLID CORE WOOD DOOR WITH FRAME AND HARDWARE. WOOD, FINISH, FRAME AND HARDWARE AS SELECTED BY OWNER. 6. ALL NEW INSTALLED DOOR FRAMES SHALL BE INSTALLED WITH TIGHT AND NEAT JOINTS AND SHALL ADHERE TIGHTLY AGAINST THE WALL. IF NECESSARY, ALL GAPS OR JOINTS SHALL BE CAULKED TO ASSURE A NEAT AND FINISHED APPEARANCE. -1. EXIT DOORS SHALL HAVE THUMB TURN LOCKS WITH A SIGN ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS ". THE LETTERS SHALL BE 1" HIGH AND HAVE A CONTRASTING BACKGROUND. 8. ALL DOORS TO HAVE "BEST LOCK" KEYED CYLINDERS, UNLESS INSTRUCTED OTHERWISE. G. FLOOR COVERINGS TO BE SELECTED BY TENANT. GENERAL NOTES I. THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS AND THE TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. 2. IT IS THE OWNER'S AND /OR TENANTS RESPONSIBILITY TO CHECK THE CONSTRUCTION DOCUMENTS AND VERIFY ANY AND ALL LOCATIONS, SIZE, QUANTITY, QUALITY AND SPECIFIC MATERIALS USED IN CONJUNCTION WITH THE OWNER'S SPECIAL EQUIPMENT LAYOUT, USE OR FUNCTION. 3. THE COORDINATION OF ALL MATERIALS, LABOR AND THE SUB - CONTRACTORS' WORKMANSHIP IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4. THE CONTRACTOR MUST VERIFY ALL CONDITIONS BEFORE STARTING CONSTRUCTION. IF A DISCREPANCY OCCURS, CONTACT THE ENGINEER BEFORE PROCEEDING FURTHER WITH CONSTRUCTION. 5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING LOCAL BUILDING OFFICIALS AND INSPECTORS FOR PERMITS AND INSPECTIONS. ADVISE THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. 6. ALL FIXTURES, EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS, RECOMMENDATIONS AND SUGGESTED INSTRUCTIONS. -7. THE MAKE AND MODEL NUMBERS SPECIFIED ARE PREFERRED OR MINIMUM STANDARDS. OTHER EQUIPMENT MAY BE CONSIDERED, IF PROVEN EQUAL. 8. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE AND SHALL BE INSTALLED IN ACCORDANCE TO ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES. Q. ITEMS NOTED "N.I.C." (NOT IN CONTRACT), "BY OWNER" OR "EXISTING" SHALL NOT BE INCLUDED IN THE CONTRACT, BUT PROVISION SHALL BE MADE BY RESPECTIVE TRADES TO ALLOW INSTALLATION OF ITEMS NOTED. ALL FINISHES OF FLOORS, BASES, WAINSCOTS, WALLS AND CEILINGS BEHIND, UNDER AND /OR OVER THESE ITEMS SHALL BE INCLUDED IN THE GENERAL CONTRACT UNLESS OTHERWISE NOTED. 10. THIS STRUCTURE SHALL HAVE INTERIOR FINISHES WITH A FLAME SPREAD CLASSIFICATION OF III (76 -200 TUNNEL TEST) AND A SMOKE DENSITY OF NO GREATER THAN 450. II. TRANSPORT TRASH, RUBBISH AND DEBRIS FROM SITE AND LEGALLY DISPOSE OF SAME. THE MANNER OF REMOVAL MUST BE CONFIRMED WITH THE OWNER AND AS ALLOWED BY CITY AND STATE REGULATIONS. DATE 10 -16 -95 DRAWN BY REC CHECKED BY FILE NAME 5145AI REVISIONS 0" (VACANT) m FUTURE N W a m EX15T. GONG. M NEW 3 5/8" METAL STUD WALL TO ROOF DECK ABOVE 18' -Q" m o ATM LOBBY CARPET EX15T. STORE FRONT (TO REMAIN) FLOOR PLAN SCALE: 1/8" = 1' -0" CONSTRUCTION NOTES X� _s I. DIMENSIONS ARE TAKEN FROM FACE OF NEW ROUGH STUD WALLS, AS SHOWN, AND FACE OF EXISTING FINISHED WALLS. 2. WALLS ARE A NOMINAL 12' -0" HIGH (VERIFY) AND SHALL BE 3 5/8" METAL STUDS AT 24" O.C. WITH PAINTED 5/8" GYPSUM BOARD ON BOTH SIDES FROM FLOOR TO CEILING WITH 4" VINYL BASE, UNLESS INDICATED OTHERWISE. (INTERIOR FINISHES TO BE SELECTED BY OWNER). 3. PROVIDE NECESSARY BLOCKING AND SUPPORT FOR ITEMS SECURED TO THE STUD WALLS. 4. ALL NEW DOOR JAMBS, HINGE EDGE OF DOOR, ARE LOCATED 6" FROM FACE OF ROUGH STUD. 5. NEW DOOR OPENINGS TO CONSIST OF 3' -0" X 1 3/4" SOLID CORE WOOD DOOR WITH FRAME AND HARDWARE. WOOD, FINISH, FRAME AND HARDWARE AS SELECTED BY OWNER. 6. ALL NEW INSTALLED DOOR FRAMES SHALL BE INSTALLED WITH TIGHT AND NEAT JOINTS AND SHALL ADHERE TIGHTLY AGAINST THE WALL. IF NECESSARY, ALL GAPS OR JOINTS SHALL BE CAULKED TO ASSURE A NEAT AND FINISHED APPEARANCE. -1. EXIT DOORS SHALL HAVE THUMB TURN LOCKS WITH A SIGN ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS ". THE LETTERS SHALL BE 1" HIGH AND HAVE A CONTRASTING BACKGROUND. 8. ALL DOORS TO HAVE "BEST LOCK" KEYED CYLINDERS, UNLESS INSTRUCTED OTHERWISE. G. FLOOR COVERINGS TO BE SELECTED BY TENANT. GENERAL NOTES I. THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS AND THE TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. 2. IT IS THE OWNER'S AND /OR TENANTS RESPONSIBILITY TO CHECK THE CONSTRUCTION DOCUMENTS AND VERIFY ANY AND ALL LOCATIONS, SIZE, QUANTITY, QUALITY AND SPECIFIC MATERIALS USED IN CONJUNCTION WITH THE OWNER'S SPECIAL EQUIPMENT LAYOUT, USE OR FUNCTION. 3. THE COORDINATION OF ALL MATERIALS, LABOR AND THE SUB - CONTRACTORS' WORKMANSHIP IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4. THE CONTRACTOR MUST VERIFY ALL CONDITIONS BEFORE STARTING CONSTRUCTION. IF A DISCREPANCY OCCURS, CONTACT THE ENGINEER BEFORE PROCEEDING FURTHER WITH CONSTRUCTION. 5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING LOCAL BUILDING OFFICIALS AND INSPECTORS FOR PERMITS AND INSPECTIONS. ADVISE THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. 6. ALL FIXTURES, EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS, RECOMMENDATIONS AND SUGGESTED INSTRUCTIONS. -7. THE MAKE AND MODEL NUMBERS SPECIFIED ARE PREFERRED OR MINIMUM STANDARDS. OTHER EQUIPMENT MAY BE CONSIDERED, IF PROVEN EQUAL. 8. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE AND SHALL BE INSTALLED IN ACCORDANCE TO ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES. Q. ITEMS NOTED "N.I.C." (NOT IN CONTRACT), "BY OWNER" OR "EXISTING" SHALL NOT BE INCLUDED IN THE CONTRACT, BUT PROVISION SHALL BE MADE BY RESPECTIVE TRADES TO ALLOW INSTALLATION OF ITEMS NOTED. ALL FINISHES OF FLOORS, BASES, WAINSCOTS, WALLS AND CEILINGS BEHIND, UNDER AND /OR OVER THESE ITEMS SHALL BE INCLUDED IN THE GENERAL CONTRACT UNLESS OTHERWISE NOTED. 10. THIS STRUCTURE SHALL HAVE INTERIOR FINISHES WITH A FLAME SPREAD CLASSIFICATION OF III (76 -200 TUNNEL TEST) AND A SMOKE DENSITY OF NO GREATER THAN 450. II. TRANSPORT TRASH, RUBBISH AND DEBRIS FROM SITE AND LEGALLY DISPOSE OF SAME. THE MANNER OF REMOVAL MUST BE CONFIRMED WITH THE OWNER AND AS ALLOWED BY CITY AND STATE REGULATIONS. DATE 10 -16 -95 DRAWN BY REC CHECKED BY FILE NAME 5145AI REVISIONS 0" W co W a I r_ M O N O N CO Z z 0 a z t c z W W c� z � o 6 O o= r• U) Lu � W W J W a (o 0 z W � V U) Lu � W W CV M' a w mO 0 U)z< J Y a Q a cl cr Es Z_ a Qz2 .z �°QLV w J a �" T U W \ 0 cc J W LL C - GO �`� � •affil' ��iF�;. $TATE OF 00 0 e VS 000 SHEET A -1 OF 1 PROJECT NO. 95145