HomeMy WebLinkAbout1036.95.1GENERAL NOTES I. THE DRAWI1465 INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DE516N CONCEPT, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS AND THE TYPE OF STWJGTURAL, MECHANICAL AND ELECTRICAL 5Y5TEM5. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT NECE-55ARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREI`- ' OF THE CONTRACT DOCUMENTS. ON THE BA515 OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. 2. IT 15 THE OWNER'S AND /OR TENANTS RESPONSIBILITY TO CHECK THE CONSTRUCTION DOCUMENTS AND VERIFY ANY AND ALL LOCATIONS, SIZE, QUANTITY, QUALITY AND SPECIFIC MATERIALS USED IN CONJUNCTION WITH THE OI^NER'S SPECIAL EQUIPMENT LAYOUT, USE OR FUNCTION. 3, THE COORDINATION OF ALL MATERIALS, LABOR AND THE 5UB- CONTRACTOR5' WORKMANSHIP 15 THE 50LE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4. THE CONTRACTOR MUST VERIFY ALL CONDITIONS BEFORE STARTING CONSTRUCTION. IF A D15GREPANGY OCCURS, CONTACT THE ENGINEER BEFORE PROGEEDIW7 FURTHER WITH GONISTRUCTI ON. 5. THE GENERAL CONTRACTOR 15 RE51PON510LE FOR GONTACTIN6 LOCAL BUILDING OFFICIALS AND INSPECTORS FOR PERMITS AND INSPECTIONS. ADV15E THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. 6. ALL FIXTURES, EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS, RECOMMENDATIONS AND 5UG6E5TED INSTRUCTIONS. 7. THE MAKE AND MODEL NUMBERS SPECIFIED ARE PREFERRED OR MINIMUM STANDARDS. OTHER EQUIPMENT MAY BE CONSIDERED, IF PROVEN EQUAL. 6. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE AND SHALL BE INSTALLED IN ACCORDANCE TO ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES. 9. ITEMS NOTED "N.I.G." (NOT IN CONTRACT), "BY OWNER" OR "EX15nN6" SHALL NOT BE INCLUDED IN THE CONTRACT, BUT PROVISION SHALL BE MADE BY RESPECTIVE TRADES TO ALLOW INSTALLATION OF ITEMS NOTED. ALL FIN154 IE5 OF FLOORS, BASES, WAINSCOTS, WALLS AND CEILINGS BEHIND, UNDER AND /OR OVER THESE ITEMS SHALL BE INCLUDED IN THE 6ENERAL CONTRACT UNLE55 OTHERWISE NOTED. 10, THI5 STRUCTURE SHALL HAVE INTERIOR FINISHES WITH A FLAK SPREAD CLASSIFICATION OF III (76 -200 TUNNEL TEST) AND A SMOKE DENSITY OF NO GREATER THAN 450. II. TRANSPORT TRASH, RUBBISH AND D H3RI5 FROM SITE AND LEGALLY DISPOSE OF SAME. THE MANNER OF REMOVAL MUST BE CONFIRMED WITH THE OWNER AND AS ALLOWED BY CITY AND STATE REGULATIONS. DE "-10LITION NOTE i. EX15TIN6 FIN15HES TO REMAIN UNLE56 NOTED OTHERWISE. 2. REMOVE EXISTING ITEMS AS INDICATED. PATCH AND REPAIR ADJACENT FINISHES AT WALL, GEILIN6 AND FLOORS AS REQUIRED. 3 ANY ITEMS TO BE REMOVED ARE TO BE STORED AND REUSED IF P0551BLE. 4. UPON REMOVAL OF EXISTING WALLS, GEILING GRID AND TILES ARE TO 13E REWORKED AS REQUIRED FOR A UNIFORM APPEARANCE IN LAYOUT, COLOR AND TEX7URE. �C N TR,J(- T�Ov NOTE- 1. DIMENSIONS ARE TAKEN FROM FACE OF NEW RQU6H STUD WALLS, AS SHOWN, AND FACE OF EXISTING FINISHED WALLS. 2. WALLS ARE A NOMINAL 12' -0" HIGH (VERIFY) AND SHALL BE 3 5/8" METAL STUDS AT 24' O.G. WITH PAINTED 5/8" GYPSUM 80ARD ON BOTH 51DE5 FROM FLOOR TO CEILIN6 WITH 4" VINYL BASE, UNLESS INDICATED OTHERWISE. (PAINT SHOULD FIF DEVOE MOON MA616 SEMI -GLOSS ENAMEL OR EQUAL). 3. PROVIDE NEGE55ARY BLOCKING AND SUPPORT FOR ITEMS SECURED TO THE STUD WALLS. 4. ALL NEW DOOR JAMBS, HINGE EDGE OF DOOR, ARE LOCATED 6" FROM FACE OF ROU6H STUD. 5. NEW DOOR OPENINGS TO CON515T OF 3' -0" X 1 3/4" SOLID GORE WOOD DOOR WITH FRAME AND HARDWARE. HEIGHT, WOOD, FINISH, FRAME AND HARDWARE TO MATCH ADJACENT DOORS. REUSE EXISTING DOORS, FRAMES AND HARDWARE IF AVAILABLE AND APPLICABLE. 6. ALL NEW INSTALLED DOOR FRAMES SHALL BE INSTALLED WITH T16HT AND NEAT JOINTS AND SHALL ADHERE T16HTLY A&AIN5T THE WALL. IF NECESSARY, ALL GAPS OR JOINTS SHALL BE CAULKED TO A55URE A NEAT AND FINISHED APPEARANCE. 7. EXIT DOORS SHALL HAVE THUMB TURN LOCKS WITH A SIGN ADJACENT TO THE DOOR STATING *THIS DOOR TO REMAIN UNLOCKED DURING BU51NE55 HOURS ". THE LETTERS SHALL BE I" H16H AND HAVE A CONTRASTING BACKGROUND. 8. OFFICE AND ENTRY DOORS TO HAVE "BEST LOCK" KEYED CYLINDERS. q. FLOOR GOVERIN65 BY TENANT. ELE( TRi(✓ NOTE, I . FIT AND QUANTITY OF THE WIRING, ELECTRICAL EQUIPMENT, THE VARIOUS NECESSARY PARTS AND MATERIALS TO MAKE A COMPLETE AND FINISHED JOB SHALL BE VERIFIED AND COORDINATED PRIOR TO START OF CONSTRUCTION AND ARE THE EXCLUSIVE RE51PON51BILITY OF THE ELECTRICAL CONTRACTOR. 2. THE ENTIRE El EGTRICAL SHALL BE INSTALLED AGCORDING TO ALL APPLICABLE LOCAL, STATE OR FEDERAL CODES. 3. ALL FIXTURES, EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S SUGGESTED INSTALLATION REQUIREMENTS IN A NEAT AND WORKMANSHIP LIKE MANNER. 4. THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR THE START IF OF THE ENTIRE ELECTRICAL 5Y5TEM5, FURNISHING OPERATING AND MAINTENANCE INSTRUCTIONS, AND A ONE YEAR GUARANTEE. 5. ALL ELECTRICAL EQUIPMENT SHALL HAVE "UL' LABELS. 6. WIRING DEVIGES TO BE SPECIFICATION GRADE. 7. ELECTRICAL SHOWN 15 DIAGRAMMATIC AND MUST BE FIELD VERIFIED FOR EXACT ROUTING. 8. TEMPERATURE CONTROL WIRIN6 WILL BE COMPLETED BY THE MECHANICAL CONTRACTOR. q. ALL WIRE SHALL BE COPPER, MINIMUM 51ZE #12 AW6. ALL CONDUCTORS SHALL HAVE TYPE "THHN" INSULATION. CONDUCTORS #10 AND SMALLER MAY BE SOLID. 10. FURNISH AND INSTALL A BREAKER PANEL AS MANUFACTURED BY SQUARED OR ITE. INSTALL PANEL 50 TOP BREAKER 15 NO HIGHER THAN 6'- O" A.F.F. II. FURNISH AND INSTALL TYPEYrRITTEN DIRECTORY. IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. 12. CONDUIT IN FINISHED AREA TO 13E CONGEALED TYPE EMT OR AG ARMOUR GABLE AS PERMITTED BY CODE. 13. ALL UNDERFLOOR GONDUITS WILL BE P.V.G. 14. ALL SWITCHES TO 13E RATED 20 AMP., 125 VOLT AND SHALL BE MOUNTED 4'-6" A.F.F., UNLE55 NOTED OTHERWISE. 15. ALL RECEPTACLES TO BE 15 AMP., 125 VOLT, GROUNDING TYPE AND SHALL BE MOUNTED 1' -4" A.F.F., UNILE55 NOTED OTHERWISE. I6. LIGHTING FIXTURES TO BE FURNISHED AND INSTALLED COMPLETE WITH LAMPS AS DETAILED ON THE PLANS AND FIXTURE SCHEDULE. SEE THE REFLECTED CEILING PLAN FOR THE EXACT LOCATION OF THE GEILING GRID, LIGHT FIXTURES, ETC. 17, SEE THE ELECTRICAL DRAWINGS FOR THE FIXTURE SCHEDULE, NOTES AND OTHER SPECIFICATION REQUIREMENTS. 18 LIGHT AND POWER PANEL SHALL BE A 51ZE OF 120/208 VOLTS, 3 PHASE, 4 WIRE 200 AMPS MAIN LU65, 200 AMPS MAIN LU65, 200 AMPS MAIN BREAKER. EXI5TIN6 WIRE AND CONDUIT MAY 13E REUSED IF LARGE ENOUGH AND IN PERFECT CONDITION. ALL BRANCH GIRGUITS SHALL BE AT LEAST 12 GA. THW. PROVIDE DISCONNECT OR CORD AND RECEPTACLE FOR EACH PIECE OF EQUIPMENT VERIFY TENANT'S ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION. YMBOL_ L_Ec- ENE BATH FAN ® EXIT LIGHT �D EMERGENCY LIGHT O ELEG WATER HEATERS ❑J JUNCTION BOX 120 VOLT DUPLEX OUTLETS p TELEPHONE CHASE S SINGLE POLE SWITCH hw REMOVE EXISTING RELOCATE EXISTING PLUMBING FIXTURES WATER HEATER TO ABOVE GAP ALL WATER CEILING. GAP ALL AND WASTE UNUSED WATER LINES LINES ABOVE CEILING ABOVE CEILING AND BELOW FLOOR AND BELOW FLOOR 3 WAY SWITCH L.A SPRINKLER HEAD ( EXISTIN6 TO REMAIN) ° DIFFUSER 120 /20bV ®HVAC (EXISTING TO REMAIN) HVAG DIFFUSER (RELOCATED EXI5TIN6) 2X4 FLUORESCENT FIXTURE hw REMOVE EXISTING RELOCATE EXISTING PLUMBING FIXTURES WATER HEATER TO ABOVE GAP ALL WATER CEILING. GAP ALL AND WASTE UNUSED WATER LINES LINES ABOVE CEILING ABOVE CEILING AND BELOW FLOOR AND BELOW FLOOR II �� L.A 4x 50OMGM REMOVE EXISTING I I ° REMOVE EXISTING 120 /20bV FLOOR COVERINGS IOOA ELECTRICAL PANEL cn DASHED LINES c Z F INDICATE EXISTING BL DOORS I��I Iii I IPI e� - - - - _j' I r J RELOCATE I I EXISTING WALLS I REMOVE EiSTING EXISTING S.A. DIFFU5ER5I TO REMAIN I FLOOR COVERINGS EXISTING LIGHT EXISTING WALL FIXTURES TO BE TO REMAIN I RELOCATED � � I1�! I��)I II �� L.A 4x 50OMGM REMOVE EXISTING I I EXI5TIN6 r Cam> 120 /20bV FLOOR COVERINGS IOOA MAIN BRK'R cn DASHED LINES c Z F INDICATE EXISTING BL DOORS I e� FIXTURES BE REMOVED I r J RELOCATE I I (TYPICAL) EXISTING S.A. DIFFU5ER5I EXISTING LIGHT EXISTING WALL FIXTURES TO BE TO REMAIN I RELOCATED I ; (TYPICAL) 1� I NOTE! EXISTING CEILING GRID TO REMAIN EXISTING WALL EXISTING GEILIN6 TILE5 TO BE REMOVED REPLACE AND REPAIR EXISTING TO REMAIN II "T " GRID AS REQUIRED F-I ii F -1 Irk t L I L y L_ A � �I j REMOVE EXISTING CARPET REWORK EXISTING (TYPICAL) GLAZING TO PROVIDE 21" W. X 24" H. OPENIN61 FOR VERTICAL DROP I F- SLOT (PROVIDED BY F REMOVE EXI5TIN6 F 7 r ' TENANT). r', > ; DOOR HARDWARE ` J < (VERIFY LOG W/ TENAN'Fj ; <' AND SECURE DOOR J� REMOVE EXISTING WALL AND BRICK AND REWORK EXIST. STOREFRONT TO PROVIDE FOR NEW DBL. 3/0 ENTRANCE DOORS DEMOLITION PLAN SCALE: 1/8" = 1' -0" LlUrll 1 INU / k;WLINU POLAN v -- E x ISTI N6 SCALE: 1/8" = l' -O" 5ER ,1ICE !20J < ^OE ! Ex15TIW- ,:T �AB4NET t METER Xt _15l SGREW EXISTING DOORS / TO *ROORE9/6 CLOSED AND / " CLOSEUP EXISTING OPENINGS W/ DRYWALL 6RAB r BARS 11'-2 3 1b" � 3/O m OFF I (----E CA-055P EXISTING GARRET BY TENANT OPENING W/ MT'L. STUDS AND DRYWALL VERIFY EXIST. COLUMN WRAP W1 DRYWALL r� I�ARPET BY TENANT 5Q' -6" PROVIDE NEW 3/0 DEIL. ENTRY n •` EXI5TIN6 3/0 EXIT DOOR TO REMAIN 5/8" DRYWALL ON METAL FURRIN6 OVER EXI5TIN6 BLOCK WALL EXISTING COLUMN + � O FLOOR PLAN SCALE: 1/8" = 1' -0" ELECTRICAL FYIC,TINrs NOTE - VERIFY ALL ASPECTS OF Ex15TIN6 SERVICE NV UTILITY G0 PRIOR TO BIDDING NCLkVE ALL (.OA4T';, GROUNDING NOTE - GROUND TC BE l' * 10' 6RO1JNpIN& ELECTRODE (COPPER GLAD) FV 1/0 6ROUNDIN6 ELECTRODE CONDUCTOR FROM THE SERVICE ENTRANCE EGIUIPMENT TO THE &ROUNDING ELECTRODE. AL50 PROVIDE 1/0 TO STREET SIDE OF WATER MAIN W/ VC DER AROUND r4ATERMAIN ry W cr% r.Arr SCALE: 1/8" = 1' -0" NEW 120/208V 200A MAIN BRK'R SEE NOTE DATE q -25-85 DRAWN BY CHECKED BY FILE NAME 5141AI REVISIONS Lei � 4x 50OMGM I •r EXI5TIN6 r Cam> 120 /20bV IOOA MAIN BRK'R NOTE - VERIFY ALL ASPECTS OF Ex15TIN6 SERVICE NV UTILITY G0 PRIOR TO BIDDING NCLkVE ALL (.OA4T';, GROUNDING NOTE - GROUND TC BE l' * 10' 6RO1JNpIN& ELECTRODE (COPPER GLAD) FV 1/0 6ROUNDIN6 ELECTRODE CONDUCTOR FROM THE SERVICE ENTRANCE EGIUIPMENT TO THE &ROUNDING ELECTRODE. AL50 PROVIDE 1/0 TO STREET SIDE OF WATER MAIN W/ VC DER AROUND r4ATERMAIN ry W cr% r.Arr SCALE: 1/8" = 1' -0" NEW 120/208V 200A MAIN BRK'R SEE NOTE DATE q -25-85 DRAWN BY CHECKED BY FILE NAME 5141AI REVISIONS J W O a W cc 0 Q M 0 oC-) O W tO Z cr J W z7 N tY IL to to Q 44 U N T cc 0 a W cc Av� c " Goo��'G jsa G t0 � � SPATE OF news. k1- /C.7�- 4 C e L SHEET a -1 OF 1 PROJECT NO, Lei W °° I •r I r Cam> N N t cn J 0 a c Z N Wz e� Z J W O a W cc 0 Q M 0 oC-) O W tO Z cr J W z7 N tY IL to to Q 44 U N T cc 0 a W cc Av� c " Goo��'G jsa G t0 � � SPATE OF news. k1- /C.7�- 4 C e L SHEET a -1 OF 1 PROJECT NO,