HomeMy WebLinkAbout1040.95.2NOTE: OFFSET FACE OF STUD 112'
3/4' RIGID INSULATION FROM FACE OF FOUND. WALL
4' CONCRETE SLAB n,
0
a ve d d ve d d e d e n
11-112' MIN. GRANULAR FILL e ° e e °
p° °° p °
0 0 0 ° e
° ° e ° v
0 0 . v
112' EXPANSION MAT'L °° °° ° 0,- 0,-
°0 °o
o 0 0 0 o °
° ° e °
°
ve d e a v
ev oe ° v ev
O ° v
vv
cu °
v e v
e ° e ° e °
1'-4"
FOUNDATION WALL at PORCH -BRICK
TWO -STORY SLAB FOUNDATIONS
NOTE: OFFSET FACE OF STU& 112'
FROM FACE OF FOUL. WALL
BRICK VENEER
3/4' RIGID INSULATION
ANCHOR BOLTS AT 6' O.C.
°
A d .1Z
e
GRADE
°0 00
' 0 0 e
00 00
• ° e ° e
° L ° v
v vv
° e °
e
O • d v e d
sv °
CL s ° s ° L
° e ° v
v vv
° e
d L d ve d
e °
1'-4*
-13 BATT INSULATION
/ 2 MIL. VAPOR BARRIER
ANCHOR B(ILTS AT 6' 0. C.
4' CONC. SLAB ON GRADE
W/ 6 MIL. VAPOR BARRIER OVER
2'x2' CONTINUOUS PERIMETER INSULATION
GRANULAR FILL
TYPICAL FOUNDATION WALL:
x 8' "L" BLOCK ON 8' C.M.U.
x 16'x24* CONT. CONC. TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) r4 BARS CONT. ON
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
2,000 P.S.F.
R -13 BATT INSULATION
W/ 2 MIL. VAPOR BARRIER
2x4 STIRS AT 16' 0. C.
3 1/4' BASE
4' CONC. SLAB ON GRADE
W/ 6 MIL. VAPOR BARRIER OVER
2'x2' CONTINUOUS PERIMETER INSULATION
MIN. 12' GRANULAR FILL
TYPICAL FOUNDATION WALL:
x 8' "L* BLOCK ON 8' C.M.U.
x 16'x24" CONT. CONC. TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) #4 BARS CONT. ON
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
2,000 P.S.F.
FOUNDATION WALL of HOUSE - BRIgC
TWO -STORY SLAB FOUNDATIONS
2x WOOD FINISH
DOORFRAME MATERIAL
Ix2 DOOR TRIM
BY 0. H. DOOR
MANUFACTURER
4' CONC. SLAB ON GRADE
4' GRANULAR FILL
112' EXPANSION MATERIAL
d ° d v
° 00 00 �
e r !1 a f1
det.estF49
2' OVERHEAD DOOR
IDE THICKENED
AT FRONT
4' CONC. SLAB ON GRADE
6'-B* GRANULAR FILL
3 TYPICAL FOUNDATION of GARAGE DOOR
ALL FOUNDATION TYPES at...,F37
det.estF64
NOTE: OFFSET FACE OF STUD 112'
BRICK VENEER FROM FACE OF FOUND. WALL 2x4 STUDS AT 16' O.C.
3/4' RIGID INSULATION
112" DRYWALL
R-13 BATT INSULATION 4' CONC. SLAB ON GRADE
W/ 2 MIL. VAPOR BARRIER W/ 6 MIL. VAPOR BARRIER OVER
2'x2' CONTINUOUS PERIMETER INSULATION
� e ° e
FIN. GRADE ° 0. ANCHOR BOLTS AT 6' 0. C.
Z
�F
1
CL.1
O
0.
0
° MIN. 12' GRANULAR FILL
O. O.
v ° v
v ° e °
d d TYPICAL FOUNDATION WALL:
L v ° e° v e
x 8' *L" BLOCK ON 12' CAP BLOCK
Cu ° v v * 16'x24' CONT. CONC. TRENCH
d vp d e d FOOTING ON VIRGIN SOIL OR
W/ (2) M4 BARS CONT. ON
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
1'-4" 2,000 P.S.F.
FOUNDATION WALL at HOUSE - BRICK
TWO -STORY SLAB FOUNDATIONS
NOTE: OFFSET FACE OF STUD 112'
det.estF24
SIDING FROM FACE OF FOUND. WALL 2x4 STUDS AT 16' O.C.
3/4' RIGID INSULATION 112' DRYWALL
R -13 BATT INSULATION 4' CONC. SLAB ON GRADE
W/ 2 MIL. VAPOR BARRIER W/ 6 MIL. VAPOR BARRIER OVER
e d v 2x2' CONTINUOUS PERIMETER INSULATION
FIN. GRADE
° ANCHOR BOLTS AT 6' 0. C.
o °0
00 00
°0 12' GRANULAR FILL
° L ° e
Z e ° �, ° TYPICAL FOUNDATION WALL:
o e d p e x 8' 'L' BLOCK ON 8' C.M.U.
•R, C ° V ° e ° x 16'x24' CONT. CONC. TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) M4 BARS CONT. ON
e d v e e
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
1'-4* 2.000 P.S.F.
18 FOUNDATION WALL at HOUSE - SIDING
TWO -STORY SLAB FOUNDATIONS det.estF18
NOTE: OFFSET FACE OF STUD 112'
FROM FACE OF FOUND. WALL
112" DRYWALL
2x4 STUDS AT 16' 0. C.
W
4' CONC. SLAB ON GRADE
112' INSULATION SHEATHING
SIDING
ANCHOR BOLTS AT 6' O.C.
GRANULAR FILL d a J FIN GRADE TYPICAL FOUNDATION WALL
O
cu
- .. ... x B' GP BLOCK ON 8' C.M.U.
°� � °� � °� � ° x 16'x24' CONT. CONC. TRENCH
o. o� oo FOOTING ON VIRGIN SOIL OR
Y/ (2) #4 BARS CONT. ON
CERTIFIED COMPACTED FILL V/
MIN. BEARING CAPACITY OF
2.000 P.S.F.
FOUNDATION WALL at GARAGE - SIDING
TWO -STORY SLAB FOUNDATIONS
det.estF17
F---- .2% SLOPE
e° a ° e ° e ° e° a °1
° v ° ° v ° ° v °
v v o °0 °0 °0 00
FINISH GRADE p0 p0 p0 p0
1 1/2 0 00 00 00 00
vv
°
d v e d e d
O v e v ° e ° v
° e ° e °
v ° e
vv
°
d v e d e d
v e v
e ° e
1' -4"
SLAB OVERHANG at PORCH
TWO -STORY SLAB FOUNDATIONS
SIDING
3/4' RIGID INSULATION
4' CONC. SLAB
W /THICKENED EDGE
112' EXPANSION JOINT MATERIAL
11 112' GRANULAR FILL
W
W
x
W
0
NOTE: OFFSET FACE OF STUD 112'
FROM FACE OF FOUND. WALL
O
L I
11 a
°
v°
v
L
v v v e v
v °0 o °
v
o °
0,- 0'. °o o °e
o
p pe po v ° po
po
v °o °0
o o
o
°
v e d e d v
e v ° e ° v e v
vv
°
v e d e d v
e v ° e ° v e v
1'-4-
4' CONC. SLAB ON GRADE W/
THICKENED SLAB AT FRONT AND
2% DOWNSLOPE TOWARDS FRONT
GRANULAR FILL
TYPICAL FOUNDATION WALL:
x 8' CAP BLOCK
*
16'x24" CONT. CONC. TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) w4 BARS CONT. ON
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
2.000 P.S.F.
det.estFl6
112" DRYWALL
R -13 BATT INSULATION
W12 MIL. VAPOR BARRIER
ANCHOR BOLTS AT 6' O.C.
4' CONC. SLAB ON GRADE
W/ 6 MIL. VAPOR BARRIER OVER
2'x2' CONTINUOUS PERIMETER INSULATION
12' GRANULAR FILL
TYPICAL FOUNDATION WALL:
x 8' 'L' BLOCK ON 8' C.M.U.
x 16' x24' CONT. CONC. TRENCH
FOOTING ON VIRGIN SOIL OR
W/ (2) #4 BARS CONT. ON
CERTIFIED COMPACTED FILL W/
MIN. BEARING CAPACITY OF
2.000 P.S.F.
FOUNDATION PALL at PORCH - SIDING
TWO -STORY SLAB FOUNDATIONS
112' DRYWALL
3 114 BASE TRIM
d V d d I7 d d
o ° ° a 0. °o °o >'7 v 0 a °0 ° °0 0° 1 ) ° °
° ° oC
° 0_- 1 ,
WIDTH - SEE S1
TYPICAL THICKENED SLAB
at BEARING WALL
det.estFl4
112' DRYWALL
2x4 AT 16' 0. C.
4' CONC. THICKENED SLAB
MIN. 12' GRANULAR FILL
det.estF3
0
0
z
Q
cn
I
CU
cu L;
co a
i-
W
� C
z
z �
Q
J C
(3- u
8