HomeMy WebLinkAbout0889.95.2•i � a�a a�� a�i .
I 1 1 1 i
1 1 1 1 I 1
r- - - - - --
1
- 1 1 i - 1- - -- - _
-----------
------- ------ ----------------
- - -- NOTE:
PATCH EXISTING
GYP. BOARD CLG.
_ - - - WHERE SHOWER
dG GRID & SPRINKLER RECEPTION WAS REMOVED.
S REQUIRE REWORK 101 REPAINT .ENTIRE
AISE FROM 8' -11" I - - -- ---- - - - - -- CEILING.
'-6" CEILING.
.C. TO BE REWORKED
TO NEW CEILING GRID 1 1 ------
C
°
N
CP, 1 1 1 1 i
TELEPHONE
103
NOTE:
PROVIDE HIGH TEMPERATURE
SPRINKLER HEAD IN THIS
ROOM r
II
-- - - - - -- -- - - - - - - - --- --- - - - - -�
II
- - - - -- - - -- ----- - - - - -- L--
I
--- - - - - -- -- - - - - -- - - - - - - - - -
- IT
- - --
REMOVE EXISTING BULKHEAD
NOTES:
1. NEW SUSPENSION CEILING GRID
& ACOUSTICAL CEILING TILES
REQUIRED IN THIS AREA, MATCH
EXISTING.
2. THE (4) EXISTING SPRINKLERS
HEADS WILL NEED TO BE LOWERED.
3. REMOVE THE (2) 8' -0" LENGTH
FLUOURESCENT STRIP FIXTURES.
NOTE:
PUBLIC CORRIDOR WORK
NOT REQUIRED.
3 �1
+ 7— 1 1 "'
N
STAFF
RESTROOM
115
115
FAN) CORRIDOR 1
113
EXISTING FIXTURE
NOTE:
THIS ROOM MUST BE EXHAUSTED
DIRECTLY TO THE OUTSIDE
SOILED STORAGE
114
DISCONNECT NIGHT LIGHT
FIXTURE
DR.WEEKS
AND RELOCATE TO LAB /WEIGH IN c L— _DR.TRA G R
CORRIDOR. PATCH DRYWALL U 109
AS REQUIRED
t"%011 IA1f%- 01 A KI
r
NORTH
KEY PLAN
WALL LEGEND
EXISTING PARTITION
40
NORTH
- EXISTING CONSTRUCTION TO BE REMOVED
W1 = NEW WALL CONSTRUCTION TO BE:
3 5/8- METAL STUDS ® 16" O.C.
WITH 5/8" GYP. BOARD EACH SIDE.
WALLS TO EXTEND TO UNDERSIDE
OF CEILING LINE — PROVIDE SOUND
ATTENUATION BLANKETS IN WALL CAVITY
& 2' -0" EITHER SIDE OF WALL ABOVE
W2 = NEW WALL CONSTRUCTION TO BE:
3 5/8" METAL STUDS ® 16" O.C.
WITH 5/8" GYP. BOARD EACH SIDE,
TO DECK STRUCTURE ABOVE. PROVIDE
SOUND ATTENUATION IN WALL CAVITY
(INSULATION).
W3 - 42" HEIGHT HALF WALL WITH 3 5/8"
METAL STUDS ® 16" O.C. WITH 5/8"
GYP. BOARD EACH SIDE. WALL TO
HAVE 6-1/2-W. WOOD TOP CAP.
REFLECTED CEILING NOTES
1. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND REPORT ANY
DISCREPANCIES TO ARCHITECT PRIOR TO CONSTRUCTION.
2. EXISTING SUSPENDED LAY —IN CEILING TO REMAIN. REPLACE
ANY DAMAGED OR MISSING TILES TO MATCH EXISTING.
CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND
CONDITION.
3. SUCCESSFUL LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR
DESIGN /BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO
VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY
DEVICES (EXIT SIGNS, ALARMS, etc) AND VERIFY CONFORMANCE (=Architect,.
LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR
IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR Engineers &Intl
REVIEW AND OBTAINING PERMITS.
4. ALL LIFESAFETY REQUIRING ELECTRICAL HOOK —UP ARE 9100 Keystone Crossing
TO UTILIZE 4 —WIRE, 16 —GAUGE WIRE. Suite 200
5. PAINT EXISTING GYPSUM WALL BOARD BULKHEADS TO MATCH 317.848.78, Indiono 46240
CEILING AS REQUIRED. FAX 317.574,
FAX 317.574,0957
6. EXISTING DIFFUSER CFM'S TO BE VERIFIED AND BALANCED WITH
NEW DIFFUSERS FOR BALANCED AIR DISTRIBUTION THROUGHOUT Architecture
THE SPACE. MECHANICAL CONTRACTOR TO VERIFY EXISTING CFM'S. Engineering
EXISTING TRUNK LINES TO REMAIN. Land Pktrrkg
Historic Arctvtecture
7. ALL ROOM WALLS TO UNDERSIDE OF SUSPENDED CEILING L Archdale
TYPICAL UNLESS OTHERWISE NOTED. Space Planning
8. ALL WORK MUST MEET APPLICABLE STATE AND LOCAL CODES.
VERIFY ANY CHANGES FROM DRAWINGS WITH ARCHITECT.
9. PATCH, REPAIR, AND /OR REPLACE CEILING GRID SYSTEM WHERE
WALLS OR PARTITIONS HAVE BEEN REMOVED TO MATCH EXISTING.
10. RE —USE EXISTING LIGHT FIXTURES WHERE POSSIBLE, CLEAN
Drawings
SALVAGED FIXTURES, RE —LAMP AND REPLACE ANY DAMAGED
LENSES.
.t
11. MECHANICAL AND ELECTRICAL IS DESIGN— BUILD. DESIGN—
BUILD CONTRACTOR TO VERIFY LOCATION OF: DIFFUSERS,
SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT
LIGHTS, EMERGENCY /NIGHT LIGHTS, THERMOSTATS. Revi�ons
LOCATIONS OF ALL OF THE ABOVE ITEMS NEED TO BE
SUBMITTED TO DESIGNER FOR APPROVAL. LOCATIONS
PROVIDED ON THIS SHEET. ALL QUESTIONS ARE TO BE
BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE
PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR
RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY
WITH TENANT BEFORE PROCEEDING.
12. LIGHT SWITCH REQUIRED FOR EACH ROOM.
S NEW SPRINKLER HEAD REQUIRED
cat RELOCATE EXISTING SPRINKLER HEAD IN CONFLICT WITH Date Drawn By
ARCHITECTURAL ELEMENT
7/31/95 DBR
cP3 ADDITIONAL H.V.A.0 REQUIRED (SUPPLY)
cPa ADDITIONAL H.V.A.0 REQUIRED (RETURN)
cPS H.V.A.C. DIFFUSER IN CONFLICT WITH NEW WALL OR ARCHITECTURE
ELEMENT PLEASE RELOCATE
cPe PROVIDE 3 —WAY SWITCHES FOR RECEPTION 101.. z
cP� REPLACE DAMAGED CEILING TILE IN THIS LOCATION W
O
W
cPa NEW BULKHEAD WITH 18" VERTICAL DROP. OVERHEAD
CABINETS WILL BE SECURED TO UNDERSIDE OF BULKHEAD.
PROVIDE APPROPRIATE BLOCKING. 0
OcPS REMOVE EXISTING LIGHT SWITCH COVERPLATE. REMOVE W
WIRING. PATCH DRYWALL HOLE.
Q
REFLECTED CEILING LEGEND.
EXISTING 2 X 4 (18888 ACRYLIC
LENSE FLUORESCEN LIGHT
RE —USED LIGHTING IN
1G�1 NEW LOCATION
1 �J- REMOVE & REUSE EXISTING LIGHTING
EXISTING 1 X 4 ACRYLIC
LENSE FLUORESCENT LIGHT
NEW 2 X 2 DEEP CELL FLUORESCENT
- CELL FLUORESCENT LIGHT
- CEILING MTD. EXIT LIGHT
01 W /DIRECTION INDICATION
DUAL —LITE
EMERCENCY /NIGHT LIGHT
- -Q SMOKE ALARM
2 x 2 RETURN AIR GRILL
2 x 4 RETURN AIR GRILL
SLOT DIFFUSER
DIFFUSER
MERGENCY LIGHTING
EXISTING UNLESS OTHERWISE NOTED)
EXISTING 2 X 2 LAY —IN GRID
SUSPENSION SYSTEM
NEW 2 X 2 SUSPENSION CEILING GRID
AND TILE TO MATCH EXISTING
f� 6" X 6" VENT
THERMOSTAT
SPRINKLER
SWITCH
�E EXISTING LIGHT SWITCH TO REMAIN
TD DIMMER SWITCH
�3 THREE —WAY SWITCH
NOTE: CEILING HEIGHT IS 9' -6" A.F.F.
UNLESS OTHERWISE NOTED
v
Z
1 1
1 1
�1
1
IK Al
1
1
AND RELOCATE TO LAB /WEIGH IN c L— _DR.TRA G R
CORRIDOR. PATCH DRYWALL U 109
AS REQUIRED
t"%011 IA1f%- 01 A KI
r
NORTH
KEY PLAN
WALL LEGEND
EXISTING PARTITION
40
NORTH
- EXISTING CONSTRUCTION TO BE REMOVED
W1 = NEW WALL CONSTRUCTION TO BE:
3 5/8- METAL STUDS ® 16" O.C.
WITH 5/8" GYP. BOARD EACH SIDE.
WALLS TO EXTEND TO UNDERSIDE
OF CEILING LINE — PROVIDE SOUND
ATTENUATION BLANKETS IN WALL CAVITY
& 2' -0" EITHER SIDE OF WALL ABOVE
W2 = NEW WALL CONSTRUCTION TO BE:
3 5/8" METAL STUDS ® 16" O.C.
WITH 5/8" GYP. BOARD EACH SIDE,
TO DECK STRUCTURE ABOVE. PROVIDE
SOUND ATTENUATION IN WALL CAVITY
(INSULATION).
W3 - 42" HEIGHT HALF WALL WITH 3 5/8"
METAL STUDS ® 16" O.C. WITH 5/8"
GYP. BOARD EACH SIDE. WALL TO
HAVE 6-1/2-W. WOOD TOP CAP.
REFLECTED CEILING NOTES
1. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND REPORT ANY
DISCREPANCIES TO ARCHITECT PRIOR TO CONSTRUCTION.
2. EXISTING SUSPENDED LAY —IN CEILING TO REMAIN. REPLACE
ANY DAMAGED OR MISSING TILES TO MATCH EXISTING.
CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND
CONDITION.
3. SUCCESSFUL LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR
DESIGN /BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO
VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY
DEVICES (EXIT SIGNS, ALARMS, etc) AND VERIFY CONFORMANCE (=Architect,.
LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR
IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR Engineers &Intl
REVIEW AND OBTAINING PERMITS.
4. ALL LIFESAFETY REQUIRING ELECTRICAL HOOK —UP ARE 9100 Keystone Crossing
TO UTILIZE 4 —WIRE, 16 —GAUGE WIRE. Suite 200
5. PAINT EXISTING GYPSUM WALL BOARD BULKHEADS TO MATCH 317.848.78, Indiono 46240
CEILING AS REQUIRED. FAX 317.574,
FAX 317.574,0957
6. EXISTING DIFFUSER CFM'S TO BE VERIFIED AND BALANCED WITH
NEW DIFFUSERS FOR BALANCED AIR DISTRIBUTION THROUGHOUT Architecture
THE SPACE. MECHANICAL CONTRACTOR TO VERIFY EXISTING CFM'S. Engineering
EXISTING TRUNK LINES TO REMAIN. Land Pktrrkg
Historic Arctvtecture
7. ALL ROOM WALLS TO UNDERSIDE OF SUSPENDED CEILING L Archdale
TYPICAL UNLESS OTHERWISE NOTED. Space Planning
8. ALL WORK MUST MEET APPLICABLE STATE AND LOCAL CODES.
VERIFY ANY CHANGES FROM DRAWINGS WITH ARCHITECT.
9. PATCH, REPAIR, AND /OR REPLACE CEILING GRID SYSTEM WHERE
WALLS OR PARTITIONS HAVE BEEN REMOVED TO MATCH EXISTING.
10. RE —USE EXISTING LIGHT FIXTURES WHERE POSSIBLE, CLEAN
Drawings
SALVAGED FIXTURES, RE —LAMP AND REPLACE ANY DAMAGED
LENSES.
.t
11. MECHANICAL AND ELECTRICAL IS DESIGN— BUILD. DESIGN—
BUILD CONTRACTOR TO VERIFY LOCATION OF: DIFFUSERS,
SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT
LIGHTS, EMERGENCY /NIGHT LIGHTS, THERMOSTATS. Revi�ons
LOCATIONS OF ALL OF THE ABOVE ITEMS NEED TO BE
SUBMITTED TO DESIGNER FOR APPROVAL. LOCATIONS
PROVIDED ON THIS SHEET. ALL QUESTIONS ARE TO BE
BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE
PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR
RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY
WITH TENANT BEFORE PROCEEDING.
12. LIGHT SWITCH REQUIRED FOR EACH ROOM.
S NEW SPRINKLER HEAD REQUIRED
cat RELOCATE EXISTING SPRINKLER HEAD IN CONFLICT WITH Date Drawn By
ARCHITECTURAL ELEMENT
7/31/95 DBR
cP3 ADDITIONAL H.V.A.0 REQUIRED (SUPPLY)
cPa ADDITIONAL H.V.A.0 REQUIRED (RETURN)
cPS H.V.A.C. DIFFUSER IN CONFLICT WITH NEW WALL OR ARCHITECTURE
ELEMENT PLEASE RELOCATE
cPe PROVIDE 3 —WAY SWITCHES FOR RECEPTION 101.. z
cP� REPLACE DAMAGED CEILING TILE IN THIS LOCATION W
O
W
cPa NEW BULKHEAD WITH 18" VERTICAL DROP. OVERHEAD
CABINETS WILL BE SECURED TO UNDERSIDE OF BULKHEAD.
PROVIDE APPROPRIATE BLOCKING. 0
OcPS REMOVE EXISTING LIGHT SWITCH COVERPLATE. REMOVE W
WIRING. PATCH DRYWALL HOLE.
Q
REFLECTED CEILING LEGEND.
EXISTING 2 X 4 (18888 ACRYLIC
LENSE FLUORESCEN LIGHT
RE —USED LIGHTING IN
1G�1 NEW LOCATION
1 �J- REMOVE & REUSE EXISTING LIGHTING
EXISTING 1 X 4 ACRYLIC
LENSE FLUORESCENT LIGHT
NEW 2 X 2 DEEP CELL FLUORESCENT
- CELL FLUORESCENT LIGHT
- CEILING MTD. EXIT LIGHT
01 W /DIRECTION INDICATION
DUAL —LITE
EMERCENCY /NIGHT LIGHT
- -Q SMOKE ALARM
2 x 2 RETURN AIR GRILL
2 x 4 RETURN AIR GRILL
SLOT DIFFUSER
DIFFUSER
MERGENCY LIGHTING
EXISTING UNLESS OTHERWISE NOTED)
EXISTING 2 X 2 LAY —IN GRID
SUSPENSION SYSTEM
NEW 2 X 2 SUSPENSION CEILING GRID
AND TILE TO MATCH EXISTING
f� 6" X 6" VENT
THERMOSTAT
SPRINKLER
SWITCH
�E EXISTING LIGHT SWITCH TO REMAIN
TD DIMMER SWITCH
�3 THREE —WAY SWITCH
NOTE: CEILING HEIGHT IS 9' -6" A.F.F.
UNLESS OTHERWISE NOTED
v
Z
�
�
J
Cr
W
0
U
�
p
c
W
`d
Cl)
w
W
W
J
LL
W
a�
cr
p
� r 6
Sheet No.
lA2(
Of Sheets
Fie No.
95201