Loading...
HomeMy WebLinkAboutC800 Sanitary Sewer Details-Layout1Notes'. No more than 12' of adNSlmenI rings Anything above 12 n barrel seclion must be added PLAN VIEW 30 I/2" OUTSIDE DIAMETE 24" INSIDE DIAMETER --- 1/4 (TYPICAL)s 1' 1/4" (I 5/8' 3D I/8' DUISIDE DIAMETER __J APLMmmtw„Rf„„ SECTION A —A AO A c( sail OP GIST 7? o KENT SEAL PRECAST CONCRETE ADJUSTING RING OR FLANGE OF CASTING —BUTTE RUBBER COATING WIN PLASTIC WRAP COVER JOINT DETAIL 2 " -12" g - 19300219 'et • STATE OF 4/3 o %:2 /AIDIAN„'aG\ S �``M „` AONALm S"# /2 RISER RING THICKNESS 4' -12 OUTSIDE DIAMETER 34" OR 35" ADJUSTING RING DETAIL Schneider /Date 12/05/06 CLAY TOWNSHIP REGIONAL WASTE DISTRICT ADJUSTING RING DETAIL File T: \81(\8366 \O01 \DIN S \DEtAIiS\IN- DTIS.DVIG NOTE: TO BE USED SEMEN CLEAR DISTANCE (FROM EXTERIOR POE DAMEI[R N EXTERIOR PIPE DIAMETER) BETWEEN SANITARY SEWER PIPING (MANES. LATERALS FORCE MATHS. ETC.) AND ALL OTHER PIPES IS 18' OR LESS. PER ENGINEER'S DIRECTION. OR WHERE NOTED W THE CONSTRUCTION PLANS A MINIMUM CLEAR DISTANCE OF 3' MUST BE PROMDEO TO MAINTAIN STRUCTURAL INTEGRITY OF THE CONCRETE. y1110N„4 ,.D A Coq 4W P ▪ No. a - 19300219 ot STATE OF 4/35 %I?* 4Xf vXP ��. S9'' /S,S /ONAL' 3.7,x°3 eta ce_A BOTTOM OF 1500 PSI CONCRE \ /j / /\\ UNDISTURBED EARN \ / /j / \: PERSIECfif Vow -EARW CUT AWAY CRADLE SHALL BEAR ON CONCRETE CRADLE DETAIL Schneider CLAY TOWNSHIP REGIONAL WASTE DISTRICT CONCRETE CRADLE DETAIL Date 12/06/06 File T: \62\6366 \001 \TOGS\DET IIS\IN -DTIS.DMG ENCH 10 FEET TRENCH BOX OR OTHER IOWA ACCEPTABLE TRENCH SAFETY SYSTEM 1/2 0 t 12 FOR PVC PIPE V2 D E 6' MR DI 1/1 D SEE FIRST LATER BFLDNG TABLE BELOW 12 STONE AS REWIRED BY ENGINEER FOR INSTABLE SUIL CONOIPONS - DEPTH 10 STABLE GROUND PER ENGINEER Al 10P W EXOAVATI TRENCH EOM SHALL N01 EXCEED BOX j" "CLEAN' BACKFILL MATERIAL FREE OF ROCKS ITC. LARGER THAN 5' OR OTHER EXTRANEOUS MATERL (COMPACT TO PREVENT SETTLEMENT). RN AREAS WITHIN 5' OF ROAD SURFACE. BACKFILL PER REQUIREMENTS OF INDIANA DEPARTMENT OF TRANSPRIATION AND COMPACT D1 10 95% MOORED PROCTOR DENSITY. j \\ Arapaintren / /% // FIRST LAYER BEDDING TABLE PIPE WE 6.1015 16l OVER BEDDING BELOW THE PIPE BARREL AND BELL MINIMUM • 6' MINIMUM m 10' pOWI{INlxlll /„4 „/q (l's \D Ac * ox) �EGLSTC193002, STATE DF ,� >' . /NOIANw �aas' S�” /OVAL'- SAS \< NUMBER 8 CRUSHED STONE OR NUMBER 8 FRACTURED FACE AGGREGATE nu MATERIAL IS TO RE PLACED FROM 6 INCHES BELOW 10 12 INCHES ABOVE THE PPE ME TRENCH SHOULD BE A MINION OF 18 INCHES MBE, SHOVEL SUQD, HARD TAMPED AND WALKED IN. y8 CRUSHED STONE SHOVEL SLICED, HAND TAMPED AND WALKED IN. (BELL HOLE EXCAVATED) / EWER AS PER CONSTRUCTION PLANS PIPE SIZE A e UP ro IBS— 3 -0 2 -fi IC' AND GREATER 0 + 24" D t 18' SANITARY SEWER TRENCHING. BEDDING AND BACKFILL DETAIL (0) Schneider CLAY TOWNSHIP REGIONAL WASTE DISTRICT SANITARY SEWER BEDDING AND BACKFILL DETAIL Date 12/06/06 File T: \61(\6366 \ OBI \DIY S \DETAILS\ IN- DTLS.DWG CLAY TOWNSHIP REGIONAL WASTE DISTRICT SUMMARY OF LATERAL INSTALL T10N REQUIREMENTS 1. AB houses, botnhgs, etc., snag canned to The District's sane sewer system wittnn 90 days of notice frog Ping a sewer is winin 300 feet for Hamilton County or 100 feel for Boone County of the properly line as defined lnrngn Indiana Code (IC 13.25.5.2). Si* one bulMIrg may conned to Me sewer main per'aleral unless oterwlse approved by the District. 2. No foupdagon, Sump. Downspouts other storm water drains shaipb M ted lo Dishas sanitary sewer as aidgessed through our 111 Ordinance 12 O8.C8 and IA Pokyfound on our websile al dlwe,rg. 3. The existing sower hie from the building to the sego tank may only be Bd if it is healed under a b lding addnin patio, porch or paved diveway. Air test Is g a H show l acceptable Io - Tne propeny oggner shall de r tne cost a all .. - g The OW[i Inspector most duration of the e The r1 shall potily u [Patrol pi ig the lee /meal so In District can make ped delemgne I the ()ISMS Sewer liSe ordinance Lateral stubs shall remain capped nigh an Inspector Is ite. Final I shall only be made under direct supervision or a CTRWDinspector. S a1 nolticonn snag He made 24 bows pear d thr the inspection. if the inspection tats and a second nspectkm Is required, or cotractor is not on she for scheduled nspecion, or nth to cancel mepecthn. an addClmatiee of 5100.00wil be me Tnk must be paid pior to me Ole OM follow up hspedhn. 6. Properly owners are hereby advised Mal the County Board of Hearn regulates the operation and maintenance a plvale sewage disposal (po]c) systems. 1 n County Ordinance provides h pan Ms, upon connection a a p ,iblb sewer, a set* lank'. .shall he abandoned umped glean) and pled mnpkle'y wild eadh n material or stone in a safe and sanitary mauler' Please contact the appropriate County Board ul Health for Further'nrorrtri and to vilify the depadmenl of the abandonment.. 6. Acceptable Pips Matenais: PVC PIPE: SDR 95w SDR 26, ASTM D3034. SIX INCH PIPE PVC PRESSURE RATED PIPE. SDR 21, ASTM D2241, SIX INCH PIPE HES rHAINEU JOIN f PVC PPE (DIRECTIONAL DRILL): YeWnme SRD 21, ASTM 02241, SIX INCH PIPE (use oily per aaprovalofhe District Engheer) OASHETED JOINTS'. ASTM D3212 GASKETS. ASTM P471 FITTINGS. SDR 26 or toter ND 1emco'a allowed). DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERLgh IF CONNED NG INTO A LOW PRESSURE FORCE MAIN- CTRWDnmslceconladedforexl/ anm' rwl ofallowabk pumps and pump regu'eeAems •1 zs HDPE DR 11 IPS MP) L'dnnedions a-e lo be made INN Conpnessvo Fittings (Polypropylene or Rmss), MoaaniCal FAings w Eittnausan ALL PUMF CONNECTIONS -PUnms located mile than a perpendtaar m or run long¢uddaly along the building for more tan 3' shall have a dean,Phstal'M and me pipe shall be bansaicned to 6' SDR 35 pipe for connection into the pump Mallon CLEAN CUTS ARE TO BE LOCATED ND MORE THAN THREE FEET FROM THE FOUNDATICNANDFOR GRAVITY LATERALS NO MORE THAN 100 FEET APART(plsaSe see Clean OW Del &IS Type 2 and Type 3for muItple dearloul in,lelabn requirements ;. CLEAN OUT CAP REQUIREMENTS: 6' IPVC dreaded Caps Redding'' Use Number a crushed stone or Number 8 fractured lace aggregate Number 8 stone back011 modal Is to be paced from 8 inches below to 121n01es above the pipe The trench should be a minimum el 18 Inches wide (six inches on both sides of the pipe) Laterals shall be kSSibd no tloser than 20 led Ran wale, wets unhss PVC pressure grade pipe Is used meeing SDR 21 and ASTM D2241. My proposed installation requhing pressure Pope shall be reviewed and uosp4UJ by the Dssil and the DrstittY engineer prior to ujJg-n. B Mere a transition is made belmen SDR 35 pipe and p grade SDR 21 pp met-tonic-al couPlhg shag be used 10. lS shell lenninate wnho f eet ate building unkss the 0011060ns h 03 a0ove eie met No clued ne shall _ -de Ihree lee of b 0E000 foundeonergs. 11 Ad I I mate n e sa and peetk : may he the Dish-1010.0110e durhg business hours of 800am.te 4:30 pm. Monday g F - v A DIPnn t be !waled on ow web eh al hitPJn ch d.org. Clay Township Regional OU Ao District 10 /01 Noah College Suite A Indianapolis, Indiana 45283 Phone: 844-9200 Far 8449203 12. Septic emuenl shall not be pumped out Flo Ile linden/ sewer system. 13. The Datum shag Inspect Al laterals . Phase cal the g tni mice at 84x920024 hours prior m lime of imcedlm 14. Contractors shall lay 14 oil uoe.ona wire the entire lengthofthe Umnlw is be paced on top a the lateral. the used inspector ,Mil vefy pawnor-it of the wire . Alter Inspection. bedding k to he Placed on L. Wire Al exteriors swclures and ppig are subject b be tested a nyor televised upon me Ulffiels discretion. Exanre of swaures that may Le i¢Ldei ale lnaNtdes. gig RenwIols pcno pits. grease inlerceplors. etc. Tes]ny repnrements are lo verify that all strtggesare wage-light and Ina? they cmfomt l0 the Clsides VI Policy 16 Call before you diyl IUPPS- hdana 011, 48 hours prior to digging. L AIeral rev 03-26-03V TEMPORARY GLUED CAP NOTE:ALL SLAB AND CRAWL SPACE CONNECTIONS MUST BE A MINIMUM OF 3” BELOW THE FOOTER AND EXIT THE BUILDING AT THE FRONT OF THE STRUCTURE TO PROVIDE THE SHORTEST, MOST DIRECT ROUTE FROM THE BUILDING TO THE EXISTING LATERAL STUB. FOUNDATION (FOOTER) 3' MAXIMUM 6' PVC CAP FINAL GRADE :S\ * s 3 MINIMUM 6" PVC PIPE TRACER WIRE (6" X 6" X 6 ") TEE -WYE 4" SEVER 6" MINIMUM. SEE SANITARY SEWER TRENCHING, BEDDING AND BACKFILL DETAIL 4X6 RIGID 6" SEWER LATERAL CLEANOUT TYPE 1 (ONLY LANDSCAPED SURFACES WITHIN THREE FEET OF BUILDING) 4,, Schneider CLAY TOWNSHIP REGIONAL WASTE DISTRICT TYPE 1 CLEANOUT DETAIL Date 12/06/06 TRUNK LINE File T: \ GI( \ 6366 \001 \DIN S\ DETAILS \IN- DTLS.DTG BUILDING LATERAL MINIMUM SIZE= 4 1/8 BEND A MINIMUM 4" DIA. PIPE CLEANOUT SHALL BE INSTALLED WITHIN THREE (3) FEET OF OUTSIDE BUILDING WALL. A PLUG SPECIFIED BY THE PIPE MANUFACTURER SHALL BE USED TO ENSURE 100% WATERTIGHT- NESS. �IImV=U- 3' FROM It BUILDING (TYP.) oiL II� .11 col( LATERA MINIMUM SIZE= 6" II I i -- u � -- � 1/8 BEND PLAN iwlj�►����% ial • COMPACTION OF GRANULAR BACKFILL IS CRITICAL UNDER WYE AND BEND. IF PROPER COMPACTION CANNOT BE ACHIEVED, PLACE A MIN. OF 6" OF CLASS B CONCRETE AROUND 1/8 BEND. ERVICE WYE V 1 C.I. LOCATOR ROD MAG- NETIC I TPER INSTALLED PER SECTION 702 -C VIEW MIN FALL= 1/4 PER FOOT BELL HOLES SHALL BE PROVIDED UNDER PIPE ELEVATION 30 i1I RIGHT -OF -� WAY LINE SERVICE CONNECTION FOR SHALLOW SEWERS (LESS THAN 15' DEEP) NOT —TO —SCALE FINISHED GRADE NOTE: WATER MAINS SHALL BE LOCATED ON AN UNDISTURBED LEDGE. i \ \ \ \\ WATER MAIN \ J. SANE ARY SEWER.. JOINT 1C MINIMUM WATER MAIN` SANITARY SEWER- A \V I0• MINIMUM JOINT FLOW — 1 IF "Ail IS IF aB' IS THEN SANITARY SEVER PIPE SEGMENT SHALL BE 18' DR MORE 10' OR MORE NO SPECIAL PIPE MATERIAL OR GRADE REQUIREMENTS LESS MAN 18' LESS THAN 10' PVC (EITHER ASTM D 2241 (OUR 21) OR ANSI /AWWA C900 (DR 18) OR ANSI /AWWA C905 (DR 21) DR WCTILC IRON (CLASS 51 MINIMUM) NOTE: SEPARATION ISIANCES FROM WATER SUPPLIES AND PIPE CLASSIFICATIONS SHALL CONFORM 10 INDIANA STAR BOARD OF HE LTH'S 'ON -SITE WATER SUPPLY AND WASTEWATER DISPOSAL FOR PUBLIC AND COMMERCIAL EST BUSIIMENTS - BULLETIN S.E. 13' WELL /WATER SUPPLY & SEWER CROSSING DETAIL . L llIlDNx„„„/ „„ 45SPy \o A cce tie £�ad`O �G{sTEge r 's • 0 = � C . 1ry3AND00 ToA 2 N1P F *� r <Q S S /OEG . . Schneider CLAY TOWNSHIP REGIONAL WASTE DISTRICT WATER LINE CROSSING DETAIL Date 12/06/06 File T: \6K\ 6366 \001 \DIN S\DETAILS\IN- DTIS.DWG m m REVISED PER TAC COMMENTS REVISIONS CO <” s.53OEPp "i : ". . STEgO...F,V No. 's: 19358 -o• _ `' STATE OF /,Q' 'rss/ONA; ,,,a wow CO CC 1— Or o I- O z 0 w ¢ Q 0 w)- 0 Z O w 0 < >� I- cc mm F- cNo 0 > ai z¢� m • <00 z 0 o p azm0 0wzwre > 0 VT 11 CC I1 II-f a1K II— CZ W xo h we co J o - N z.2 W T a LE A CL 3 N 1..V am W xo ex 0 Lin 4s SANITARY SEWER >2 J U 0) r IL 7 00 U LLJ W 0 V) HAMILTON COUNTY, INDIANA CLAY TOWNSHIP DRAWN BY \RG CHECKED BY. BAH SHEE NO. C800 & A JOB NO, 55960PUL