HomeMy WebLinkAbout0551.95.26U E V R 1 R 1N R K H E E T
RYLAND
FOUNDATION CHECKLIST
FRAME PUNCH -OUT CHECK LIST
t GARAGE
BASEMENT
� SLAB
�. DOOR OPENIr� FRAMED TO CORRECT SIZE: ,' HT„ s' OR 16' WIDE.
GARAGE ATTIC ACCESS FRAMED TO CORRECT SIZE AND LOCATION.
PROJECT INFORMATION
PROJECT INFORMATION
NAILERS AT ALL CORNERS OF GARAGE AND CEILING.
GARAGE STEP FRAMED AND KICK PLATE UNDER DOOR
BOW STUDS
STRAP ANCHOR NAILED CORRECTLY
LUBBER RACK BUILT t EXTRA MATERIAL STACKED ON
HOUSE NAME / ELEV.
HOUSE NAME / ELEV.
2. HOUSE
CHECK FOR BOW STUDS
SET NUMBER
SET NUMBER
CHECK FOR NAILERS
MARK DOOR SWIW3 DIRECTION AND SIZE
PLAN / JOB NUMBER
PLAN / JOB NUMBER
cHEac FOR CASING ROOM (MIN. 2" ON EACH SIDE)
CHECK CENTERLINE OF KITCHEN WINDOW
STANDARD OR REVERSED
STANDARD OR REVERSED
CHECK BULKHEAD DIMENSIONS
CHECK WALL SIXES IN RELATION TO CABINET SPACE
CHECK VANITY SIZES IN RELATION TO WALL SPADE
ANY NON -STD. CHANGES?
ANY NON -STD. CHANGES?
CHECK VANITY DEPTH TO DOOR OPENING (MIN. 24 1/2 ")
CHECK DOOR OPERATION AND INSTALLATION
FRONT OR SIDE LOAD
FRONT OR SIDE LOAD
GHEC-.IK WINDOW OPERATION AND INSTALLATION
CHECK BASEMENT STAIR AND 2nd FLOOR STAIR INSTALLATION
PITCH RAIL WALL INSTALLED 1/2" BELOW STRINGER
STD., ENLARGED, OR FULL BSMT.
ALL SIDING OR BRICK FRONT
HALF -WALL 42" FROM FLOOR AND SAME PITCH AS STAIRS (BOTH STAIRWAYS)
(N SET ') (OPT. 293) (OPT. 295)
(IN SET «) (OPT. 490)
HALF -WALL AT STAIRS PAST STRINGER 1 1/2"
TUB PLATFORM BUILT CORRECTLY ib 1/2" HT., 39" X 51" INSIDE
ALL SIDING OR BRICK FRONT
MASONRY
NO 5TUD5 * 24" O.G. AT CERAMIC AREAS. (Vol' OZ. MAX.)
TUB BLOCKS INSTALLED AT CERAMIC AREAS.
(N SET «) (OPT. 4W)
FIREPLACE OPT. PRE -FAB
NAILERS FOR FIBERGLASS TUBS INSTALLED
BSMT. WINDOW OPT. QTY.
NOTE. INSTALL BRICK LEDGE ON MASONRY FIREPLACES
MEASURE VINYL AREAS FOR SQUARE
CB PANELS HAVE BLOCKS ON ENDS
(MARK LOCATIONS) ON PRNT
BUILDING PERM 1 T NUMBER
CHECK FOR LOAD - BEARING POINTS IN HOUSE AND PROPER LOAD TRANSFER
MASONRY
STRAP ANCHORS SECURED IN HOUSE
FIREPLACE OPT. PRE -FAB
CRAWL SPACE AND BASEMENT CLEANED OUT
STAIRWAY SHIMMED (MAX. 1/2" GAP EACH SIDE)
NOTE: INSTALL BRICK LEDGE ON MASONRY FIREPLACES
Iet AND 2nd FLOORS LINE UP N STAIR WELL
NO GAPS ABOVE STAIRIJAY DRAFTSTOP
BUILDING PERMIT NUMBER
STAIRWAY DROP CEILING DONE CORRECTLY (CHECK PRINTS)
RISER INSTALLED AT TOP BASEMENT STEP
HANDRAIL BLOCKS INSTALLED 32" FROM STAIR NOSING
CHECKLIST
CHECKLIST
SAFETY BOOTS AND RAILS INSTALLED
STROW35ACK IN FLOOR TRUSSES BLOCKED AND NAILED TIGHT
SUMP PUMP LOCATION MARKED
MARK OUT ALL HAUNCHES NOT USED
FLOOR SHEATHING NAILED PER SPEC.'e
SUMP PUMP SLEEVE LOCATION MARKED
MARK IN FRONT PORCH WALLS IF NOT ON PRINTS
FALL PROTECTION INSTALLED AT STAIR WALL OPENINGS
MARK OUT ALL HAUNCHES NOT USED
WATER SLEEVE LOCATION MARKED
EYEBOLT AND ANCHOR POINT IN PLACE
MARK N FRONT PORCH WALL IF NOT ON PRNTS
HIGHLIGHT ALL THICKENED SLAB FOOTINGS
ALL DRAFT STOP INSTALLED ON CHASE AND BAND JOISTS
SEWER AND WATER SLEEVE LOCATIONS MARKED
SEE 4" SEWER COUPLER 5' O 1 TI SLEEVE)
HIGHLIGHT ALL PAD FOOTING LOCATIONS
ALL TYVECK STAPLED IN -PLACE EXTERIOR
ALL HOLES PATCHED IN INSULATION BOARD
HIGHLIGHT ALL BEAM POCKETS
ALL TRIM INSTALLED PER PRINT
HIGHLIGHT ALL PAD FOOTING LOCATIONS
3 112" RIPS 1/2 SHEATHING INSTALLED ON CORNERS
ALL WINDOWS TAPED ON TOP AND GLUED ON FOUR SIDES
ALL DOORS TAPED ABOVE
PRINT HUNG ON NAIL IN GARAGE
DO NOT REMOVE BLUEPRINTS FROM JOBSITE
AND PANELS GLUED t' !
INTERIOR WALLS GLUED DOWN t'
INTERIOR W
INTERIOR AND EXTERIOR WALLS NAILED INTO TRUSSES BELOW
1. EXCAVATOR PLACE PRINT TUBE INSIDE OF EXCAVATION.
SET TUBS INTO ROOM AND WIPE -OUT
ATTIC ACCESS INSTALLED N HOUSE PER PRINT, 12" SIDES
2. WALL CONTRACTOR LEAVE ON TOP OF WALL.
ALL WINDOWS INSTALLED PER PRINT, ELEVATION AND STACK
3. PLUMBING CONTRACTOR LEAVE ON TOP OF WALL.
JOIST HANGERS "LEDTFRONT OF AND DEBT
4. CONCRETE CONTRACTOR LEAVE ON TOP OF WALL.
SITE PIGGED UP AND Put IN PILE SAC# -I DAY
2X4 AROUND TOP OF CHIMNEY, I I/2" PAST G- iIMNEY FLAT
ALL GIRDER TRUSSES NAILED PER ENCsiNEERNG
1