Loading...
HomeMy WebLinkAbout0658.95.2N N — FIN. FLR. — FIN. FLR. GARAGE SLAB --�� WATER PROOFING W/'`� PROOFING PERIMETER PERIMETER DRAIN SLAB GONG. DRAIN 4" GONG. SLAB 16" WIDE x 8" DEEP I6" WIDE x 6" DEEP • GONG. FTC. GONG. FOOTING ON/ (2) #5 BARS GONT. O W/ (2) #5 BARS GONT. ry N FIN. FLR. — FIN. FLR. PORGH SLAB GARAGE 5LAB c�`i GONG. BLOCK N GONG. BLOCK 16 "x8" DEEP 16 "x8" DEEP GONG. FOOTING GONG. FOOTING W/ (2) #5 BARS W/ (2) #5 BARS GONT. ® GONT. LON FOUNDATION DETAILS_ BASEMENT PLAN SCALE= 1/4 " =1' -0" FOUNDATION. NOTES: I. ALLOWABLE 501L PRESSURE 2000 PSF. 2. FLOOR SLAB AREAS TO BE COMPACTED TO a5% MAX. DRY DENSITY. 3. STANDARD BASEMENT AND GARAGE SLAB TO BE 4" CONCRETE ON 6 MIL. VAPOR BARRIER OVER 4" GRAVEL FILL. 4. STRUCTURAL CONCRETE FOOTING TO BE 2500 PSI, 5LA135 3500 P51. 5. BOTTOM OF ALL FOOTINGS TO BESET BELON LOCAL FROST LINE. SEE DETAILS. 6. PROVIDE ANCHOR BOLTS 1/2" DIA. xIO" STARTING ® 6" FROM EACH CORNER ® 6-0" O.G. AND AT EAGH SIDE OF ALL OPENINGS, MIN. (2) PER PIECE OF SILL. Design Loads: FLOOR 40 PSF LIVE LOAD 10 P5F DEAD LOAD ROOF 30 PSF LIVE LOAD 10 P5F DEAD LOAD Design Loads: I. THE CARPENTER SHALL CAREFULLY LAY OUT AND ERECT ALL STRUCTURAL MEMBERS OF ROUGH CARPENTRY, FRAMING, SHEATHING, AND BRIDGING. ALL MEMBERS SHALL BE PROPERLY PLUMBED, LEVELED, AND BRACED UNTIL ALL STRUCTURAL CONNECTIONS ARE IN PLACE. A SUFFICIENT NUMBER OF NAILS, 5GREW5, AND BOLTS SHALL BE USED TO INSURE THE RIGIDITY OF THE CONSTRUCTION. 2. FRAMING LUMBER SHALL CONFORM WITH NATIONAL DESIGN SPECIFICATIONS FOR 5TRE55 GRADE LUMBER AND ITS FASTENINGS. JOISTS AND ALL OTHER: NO.2 DOUGLAS FIR LARCH OR YELLOW PINE Fb = 1450 psi Fc = 1000 psi E = 1,160,000 pdI 3. ALL FIRST FLOOR SILL PLATES, CRAWL SPACE FRAMING, AND STRUCTURAL MEMBERS EXPOSED TO WEATHER SHALL BE WOLMANIZED PRESSURE TREATED. 4. ROOF TRJ55 DESIGN, 5PECIFIGATION, AND ERECTION PROCEDURE TO BE 5UPPLIED BY THE TRU55 MANUFACTURER. 5. MICRO -LAM BEAM STRUCTURAL PROPERTIES, Fb = 2800 psi Fc = 2-700 p51 E = 2,000,000 p81 6. PROVIDE DIAGONAL BRACING AT ALL EXTERIOR CORNERS. -7. FRAMING OVER GIRDER AND BEARING PARTITIONS. J015T5 MAY BE BUTTED TOGETHER OVER THE CENTER BEARING, PROVIDE JOISTS ARE TIED TOGETHER, OR J015T5 MAY BE LAPPED AND NAILED TOGETHER. MINIMUM LAP, 4 INCHES; MAX. OVERHANG, 12" 8. FLOOR JOISTS SHALL BE DOUBLE UNDER EACH PARALLEL PARTITION. q. BRIDGING. MAXIMUM SPACING 10'. BRIDGING SHALL BE GRO555RIDGIN6 USING Ix3 INCH BOARDS OR SOLID BRIDGING OF JOIST DIMENSION. 5ET SOLID BRIDGING IN AN OFFSET FASHION. 10. WALL 4 PARTITION FRAMING. UNLESS OTHERWISE SHOWN 5PAGE STUDS ® 16" O.G. DOUBLE STUDS AT OPENINGS. CONSTRUCT PARTITION CORNERS WITH NO LE-55 THAN 3 FULL MEMBERS. WALLS AND BEARING PARTITIONS SHALL HAVE DOUBLE TOP PLATES. PLATES RESTING ON MA50NRY OF GONGRETE SHALL BE ANCHORED WITH BOLTS. 11. GLUE 5UB -FLOOR USING RECOMMENDED ADHESIVE, APPLY GLUE BEAD TO FRAMING AND ALONG PANEL GROVE EDGES, NAIL W/ IOD NAILS ® 12" O.G. 12. PROVIDE NAILER5, NAILING STRIPS, AND OPOUND5 AS NECESSARY AND RIGIDLY 5EGURE IN PLACE FOR ATTACHMENT OF TRIM, FINISH, AND OTHER WORK. 13. J015T HANGERS ® ALL FLUSH BEAMS SHALL BE MIN. 16 GALV. STEEL, AND PROPERLY 51ZED TO ACCEPT JOISTS. N v N N S� �1 C-Mg