HomeMy WebLinkAbout0340.95.2.G _ I Q m i i GUNITE /CONCRETE WALL MINIMUM 8' THICK WITH #4 @12' BOTH WAYS cm I C LIGHT IN WALL SEE DETAIL 9 POOL PLAN 1/8' - 1' -0' 1 -2 75 -0 1 -2 DENOTES WALL INLET 8 REQUIRED I � 1 -2 I WATER LEVEL _n 3'-4' RADIUS MAXIMUM GUNITE /CONCRETE WALL MINIMUM 8' THICK WITH #4 @12' BOTH WAYS MAIN DRAIN SEE DETAIL 0 _I 4' CONCRETE POOL DECK 1�2' WITH 6X6 10/10 WWM POOL DECK BY G.C. WITH LIGHT BROOM FINISH, TOOL ALL EDGES AND SLOPE 1 /4' /FT. AWAY FROM POOL `L CONTINUOUS 142X14' BOND BEAM W/ 444 VERT. HOOKED GUNITE /CONCRETE WALL MINIMUM 8' THICK WITH 14 @12' BOTH WAYS 8. POOL SECTION 8 -B #-ON 1/8 = GUNITE /CONCRETE FLOOR MINIMUM 6' THICK WITH #4 @12' BOTH WAYS 6' X 6' TILE LANE MARKERS WITH RACING LANES 4' CONCRETE POOL DECK WITH 6X6 10/10 WWM POOL DECK BY G.C. WITH LIGHT BROOM FINISH, TOOL ALL EDGES AND SLOPE 1 /4' /FT. AWAY FROM POOL CONTINUOUS 14'X14' BOND BEAM W/ 444 VERT. HOOKED GUNITE /CONCRETE WALL MINIMUM 8' THICK WITH #4 @12' BOTH WAYS GUNITE /CONCRETE FLOOR MINIMUM 6' THICK WITH #4 @12' BOTH WAYS I 4 -0 3 TREADS @ 16' WATER LEA m, _ \ w m Ll cn GUNITE /CONCRETE WALL MINIMUM —7 12' THICK WITH 14 @12' BOTH MAYS L STEP SECTION C -C 3/B' = 1' -0' GUNITE /CONCRETE FLOOR MINIMUM 6' THICK WITH #4 @12' BOTH WAYS L rId- Ll L J ,I 0F: 4 CWK 951 M DAVE MAR. 30, ON