HomeMy WebLinkAbout0353.95.1ACOUSTICAL SEAL AND FIRE SEAL FOAM AT DECK NEW (1) RATED CLG. 5/8" r 5/8" Sig" �' J- CHANNEL ACOUSTICAL SEAL NEW (1) RATED CLG. 5 /8" ACOUSTICAL SEAL AND FIRE SEAL FOAM AT DECK FIRE RATED WOOD BLO AS REQUIRED TO ANCH STEEL HANDRAIL. 1/2" DIA. STEEL 4NDRAIL (PAINT) _EV. VARIES V' A.F.F. RAMP DETAIL 2 SCALE: 1 1/2 = 1' -O" EXTEND EXISTING WALL TO DECK WITH 18 GA. STUDS 16" O.C. J- CHANNEL ACOUSTICAL SEAL NEW (1) RATED CLG. REMOVE EXISTING G.W.B. 5/ BOTH SIDES 10' -0" HIGH 5/8" FIRE RATED PLYWOOD (BATTERY OR NODE ROOM SIDE ONLY) 5/8" TYPE "X" GYPSUM WALLBOARD (BOTH SIDES) ACOUSTICAL SEAL AND FIRE SEAL FOAM AT FLOOR 3 518" X 180A. MTL.-----_j (80TH SIDES) STUDS ® 16" O.C. t WALLTYPE W3- SCALE: 1 112" = 1' -0" 1 HR. FIRE RATING WHEN CONT. TO DECK 5/8" 516' NEr ACOUSTICAL SEAL AND FIRE SEAL FOAM AT DECK DETAIL 1 SCALE: 1/4" = 1' -0" O DOOR AND FRAME SCHEDULE STANLEY DOOR FRAME 10' -0" HIGH 518" HDWR REMARKS 755B SIZE FALCON QG LEVER, US3 FINISH MANUFACTURER: FIRE RATED PLYWOOD 408, 436 OR 438 SERIES, US26 #14118 -GRAY GRID NFG: ARMSTRONG SIZE: DETAILS (BATTERY OR NODE ABBREVIATIONS M NOTE: HOLD DOWN CLIPS ARE REQUIRED ROOM SIDE ONLY) r NODE ROOM AND 518" TYPE "X" GYPSUM BATTERY 5/8" TYPE "X" GYPSUM TO BE SET IN SANITARY WALLBOARD (BOTH SIDES) t TO SEAL ACOUSTICAL SEAL AND FIRE SEAL FOAM AT FLOOR WALLBOARD (BOTH SIDES) -'I LIQUID BARRIER SEAL BETWEEN R, ACOUSTICAL SEAL AND FBOTH AL FOAM AT FLOOR 3 5/8" X 18GA. MTL. 4 - (BOTH SIDES) 3 518" X 18GA. MTL. :=1 0 ~' J STUDS ® 16" O.C. O_ STUDS ® 16" O.C. I , Z WALLTYPE W1- WALLTYPE W2-1 SCALE: 1 1/2" = 1' -0" 1 HR. FIRE SCALE: 1 1/2" = 1' -0" 1 HR. FIRE W RATING WHEN Li RATING WHEN W C_D CONT. TO DECK Cn NQ CONT. TO DECK FIRE RATED WOOD BLO AS REQUIRED TO ANCH STEEL HANDRAIL. 1/2" DIA. STEEL 4NDRAIL (PAINT) _EV. VARIES V' A.F.F. RAMP DETAIL 2 SCALE: 1 1/2 = 1' -O" EXTEND EXISTING WALL TO DECK WITH 18 GA. STUDS 16" O.C. J- CHANNEL ACOUSTICAL SEAL NEW (1) RATED CLG. REMOVE EXISTING G.W.B. 5/ BOTH SIDES 10' -0" HIGH 5/8" FIRE RATED PLYWOOD (BATTERY OR NODE ROOM SIDE ONLY) 5/8" TYPE "X" GYPSUM WALLBOARD (BOTH SIDES) ACOUSTICAL SEAL AND FIRE SEAL FOAM AT FLOOR 3 518" X 180A. MTL.-----_j (80TH SIDES) STUDS ® 16" O.C. t WALLTYPE W3- SCALE: 1 112" = 1' -0" 1 HR. FIRE RATING WHEN CONT. TO DECK 5/8" 516' NEr ACOUSTICAL SEAL AND FIRE SEAL FOAM AT DECK DETAIL 1 SCALE: 1/4" = 1' -0" O DOOR AND FRAME SCHEDULE STANLEY DOOR FRAME LABEL HDWR REMARKS 755B SIZE FALCON QG LEVER, US3 FINISH MANUFACTURER: IVES 408, 436 OR 438 SERIES, US26 #14118 -GRAY GRID NFG: ARMSTRONG SIZE: DETAILS MODEL: PRELUDE FIRE GUARD ABBREVIATIONS M NOTE: HOLD DOWN CLIPS ARE REQUIRED NOTE: RESILIENT BASE IN NODE ROOM AND TO AVOID "BLOWING OUT" IN THE BATTERY ROOM IS TO BE SET IN SANITARY Cr m WD = SOLID CORE WOOD W/ PLAIN SLICED OAK VENEER TO SEAL SEAMS TO PROVIDE LIQUID BARRIER SEAL BETWEEN R, IZ V) W J 0 ~' J J O_ Z Z M BS = BUILDING STANDARD O 2 Q 2 C� Z Y U W 1- W � W (n Cn Li W W C_D QQj Cn NQ M W m J --I a Z W o _ w c� CL Q x- Q LD J W J C-D z� can J ZD LO 1 3' -0" 8' -6" 1 3/4 WD - - BS HM 16 - - - - - - - * DOOR AND HARDWARE TO MEET EILDG 5TANDARDS, SEE BEL • TENANT TO COORD. WHICH SET APPLIES TO L OR 2 3' -0" 8'-6" 1 3/4' WD - - BS HM 16 3 3' -0" 7' -0" 1 3/4 WD - - BS HM 16 4 3' -0" 7' -0" 1 314 WD - - BS HM 16 5 3' -0" 7' -0" 1 3/4' WD - - - BS JIHM 16 HARDWARE SCHEDULE PASSAGE SET (2) PAIR OF HINGES (4) SILENCERS (1) PASSAGE SET (1) STOP STANDARDS) MANUFACTURER: STANLEY FBB 179 4 112" X 4 1/2-, US3 MANUFACTURER: GLYNN JOHNSON GJ 64, US26 755B MANUFACTURER: FALCON QG LEVER, US3 FINISH MANUFACTURER: IVES 408, 436 OR 438 SERIES, US26 EXTEND EXISTING INTERIOR WALL CONSTRUCTION TO THE DECK WITH 3 5/8" X 18 GA. METAL STUDS AT 16" O.C. W/5/8" TYPE X G.W.D. FIRE SEAL AT DECK (1 HOUR FIRE RATED) LOCKSET DOORS (ENTRANCE (2) PAIR OF HINGES MANUFACTURER: STANLEY FBB 179 4 1/2" X 4 112", US3 (4) SILENCERS MANUFACTURER: GLYNN JOHNSON GJ 64, US26 (1) LOCKSET MANUFACTURER: FALCON W/ BEST CYLINDERS, QG LEVERS, US3 (1) STOP MANUFACTURER: IVES 408, 436 OR 438 SERIES, US3 (1) CLOSER MANUFACTURER: SARGENT 1250 SERIES /LCN 4010/4110, US3 I FINISH LEGEND I LEA O O FLOORING OWALLS O BASE F] CEILING NOTE: FINISHES NOTED IN THE BOX REPRESENT TYPICAL FINISHES FOR THAT AREA. ANY VARIATIONS TO THOSE FINISHES WILL BE FOUND OUTSIDE THE BOX. ANY QUESTIONS REGARDING FINISHES SHOULD BE DIRECTED TO THE ARCHITECT BEFORE PROCEEDING. sPECFCATKM FLOOR FINISHES VCT1 ITEM: VINYL COMPOSITION TILE MFG: ARMSTRONG OR EQUAL STYLE: ARMSTRONG COMPANION SQUARE #51974 COLOR: POLYCHROME WHITE SIZE: 12" X 12" CF ITEM: RAISED COMPUTER FLOOR (TO BE BID) TO BE TATE CONCORE 1250, 2'X2' WITH 2' -0" BOLT ON STRINGERS AND CONCRETE CORE TILES. TILES TO BE NEVAMAR GRAY STARLIGHT #ST -6 -1. WALL FINISHES P1 ITEM: PAINT MFG: BENJAMIN MOORE OR EQ. COLOR: EGGSHELL FINISH: #869 CEILING BASE Cl TILE MFG: ARMSTRONG B1 MATERIAL: VINYL COVE BASE STYLE: ACOUSTICAL TILE /FISSURED MODEL NO. 755B MFG: ARMSTRONG OR EQUAL SIZE: 2' X 2' X 5/8" STYLE: ARMSTRONG STANDARD COLOR: WHITE #14118 -GRAY GRID NFG: ARMSTRONG SIZE: 4" H. MODEL: PRELUDE FIRE GUARD COLOR: WHITE NOTE: HOLD DOWN CLIPS ARE REQUIRED NOTE: RESILIENT BASE IN NODE ROOM AND TO AVOID "BLOWING OUT" IN THE BATTERY ROOM IS TO BE SET IN SANITARY EVENT OF FM -200 RELEASE SILICONE TO SEAL SEAMS TO PROVIDE LIQUID BARRIER SEAL BETWEEN R, ACCESS FLOOR Of RAMP CONSTRUCTI 2 X 6 FIRE RTD. WOOD BLOCKING 3 5/8" X 18GA. STUDS ® 16" O.0 ACOUSTICAL SEAL AND FIRE SEAL FOAM AT FLOOR DETAIL 3 SCALE: 1 1/2" = 1' -0" Al I'"' PLATE THRESHOLD EXTEND EXISTING INTERIOR WALL CONSTRUCTION TO THE DECK WITH 5/8" TYPE X GYPSUM WALLBOARD FIRE SEAL AT DECK (1 HOUR FIRE RATED) VERIFY EXISTING METAL STUDS TO DECK. EXISTING WALL IS INSET +/ -6" ABOVE CEILING TO CLEAR EXISTING DUCKWORK A& FRONT ❑O Ufl -12 U5-8 U1 -4 MIN C1 81 5.05 5.04 5.03 5.02 5 AD.01 I 34.5' AL FRONT I 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 I� I I 33" AL FRONT CIA 201 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 Norm �mfl m m 2 1 7m: FINISH NOTES: 2 N 1. PAINT ALL INTERIOR HOLLOW MEAL --RAMES TO MATCH BUILDING STANDARD. Ll 2. 4" STRAIGHT RESILIENT BASE (B') SHALL BE INSTALLED AT ALL EXTERIOR WA-1-S, INTERIOR BAR' 70NS, AND COLUMN ENCLOSURES IN CARPETED AREAS. I I 3. 4" STRAIGHT RESIDENT BASE (B1) SHALL BE INSTALLED AT ALL EXTERIOR WALLS, INTERIOR PART'T OHS, AND COLUMN ENCLOSURES IN AREAS WITH VCT TILE AND RAISED COMPUTER FLOORS. 4. ALL LiN'& MATER'ALS SnALL- BE NSTALLED PER MANUFACTURERS SPECIFICATIONS. 5, PAINT ALL EXTERIOR DOORS, WALLS, AND FRAMES TO MATCH EXISTING. I 6. STAIN AND N SH ALA WOOD DOORS TO MATCH BUILDING STANDARD j I I 11'x9' -6" I COLLOCATION I I I I 11'x9' -6" I I PROVIDE ACCESS OPENING W/ SMOKE /FIRE STOP WHERE INDICATED, SEAL AIR TIGHT W/ ACOUSTICAL' SEALANT 8 "FIRE RATED PLYWOOD IISH FLOOR EXTEND EXISTING INTERIOR WALL FLOOR PLAN CONSTRUCTION TO THE DECK WITH 5/8" TYPE X GYPSUM WALLBOARD SCALE 1/4" _ ,' -O" FIRE SEAL AT DECK (1 HOUR FIRE RATED) VERIFY EXISTING METAL STUDS TO DECK. 1 1'x9' -6" NOT USED DETAIL 4 ACCESS FLOOR OR - RAMP CONSTRUCTION HANDRAIL 5/8" TYPE X G.W.B. FINISH FLOOR DETAIL 5 SCALE: 1 1/2" = 1' -0" I' i ii - ALUMINUM THRESH D j l SEE DETAIL 3 I I J � jai I 5 -0" jll CORRIDOR I o; N I I I l�I OPEN OFFICE =Architei Engineerskr 9100 Keystone Crossing Suite 200 Indianapolis, Indiana 462 317.848.7800 FAX 317.574.0957 F-Tr7=T--r1 Lend PWrrft Historic Architecture Landscape Ard*6ch" Interior Dedon ®Copyright 1995 Bowe r- araeiy. i e- Bowe Drw*W � T wm. ar a.eae a�mar"Wr d t4/ euN wr.i .r",.are aea w iwcu.viy lydcele or Aaa tar tiM pa ft 0a to t . d Me Oanbaet. tr ..apa bidcaLO er O"cfe l.ra shall /umiak of Ram .I"Clh.n did eampbtcn Date Drawn ey 4/3/96 PSWJW Z Um Q J A,. CerWod By W. No. :8605; �.c)t, a STATE OF C,(*%% jvD««�« OVAL CerMed By Sheet No. A21 Of Sheets Fk No. 9502: