HomeMy WebLinkAbout0353.95.4DROP WASTE AT THIS POINT —N, VV—> EXISTING 38"X 10" I I I ,' EG1 I REMOVE AS INDICATED I MECHANICAL FLOOR PLAN 16 "X10" ROUTE TIGHT TO BOTTOM OF BEAM AT 9' -4" AFF, THEN RISE TO STUCTURE ROUTE TIGHT TO BOTTOM OF BEAM AT 9' -4" AFF, THEN —T RISE TO STUCTURE n. DROPS GENERAL NOTES A. A MAXIMUM OF FIVE FEET OF FLEXIBLE DUCTWORK MAY BE USED AT ALL SUPPLY DIFFUSERS. BRANCH DUCTWORK TO DIFFUSER SHALL BE SAME SIZE AS DIFFUSER INLET. REFER TO DIFFUSERS IN EQUIPMENT LIST FOR INLET SIZES. BALANCE DAMPERS SHALL BE LOCATED AT BRANCH CONNECTION TO MAIN. AVOID SHARP BENDS IN FLEXIBLE DUCTWORK WHICH MAY CAUSE EXCESSIVE NOISE. DUCT SIZING BASED UPON 0.10" S.R. DROP PER 100' DUCT. B. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE, AND SHALL CONFORM WITH ALL FEDERAL, STATE, AND LOCAL CODES AND STANDARDS. THE SAME ARE MADE A PART OF THESE CONTRACT DOCUMENTS, THE SAME AS IF REPEATED HEREIN. C. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED MATERIALS INCLUDING ALL DIFFUSERS, GRILLES, AND REGISTERS. D. CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT. E. CONTRACTOR SHALL THOROUGHLY EXAMINE THE WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. F. CLEARANCE BETWEEN CEILING AND STRUCTURE ABOVE THE NODE ROOM IS AT 0' -9 ". CLEARANCE ELSEWHERE IS A MAXIMUM OF 1' -10 ". KEEP ALL DUCTWORK TIGHT TO BOTTOM OF STRUCTURE. COORDINATE ROUTING WITH LIGHTING, ETC. BEFORE INSTALLATION. G. WALLS AROUND PERIMETER OF BATTERY AND NODE ROOMS SHALL BE TO DECK. ALL PENETRATIONS THROUGH WALL SHALL BE SEALED AIRTIGHT. HVAC PLAN NOTES Z Oi FM200 EVACUATION FAN FOR FIRE /SMOKE ZONE. REFER TO SHEET FP201. UNIT SHALL BE SUSPENDED FROM STRUCTURE ABOVE WITH VIBRATION ISOLATORS AND FLEXIBLE CONNECTIONS AT DUCTWORK. REFER TO ELECTRICAL DRAWINGS FOR POWER CONNECTION, LOCATION OF MANUAL PULL STARTER, AND INTERLOCK WITH TRANSFER DUCT MOTORIZED DAMPER. 2O REMOVE EXISTING 60 "X18" GLAZING AT BOTTOM OF EXTERIOR WALL. PROVIDE 60"X18" EXTERIOR WEATHERPROOF LOUVER, ANODIZED TO MATCH EXISTING BUILDING EXTERIOR FINISH. PROVIDE BACKDRAFT DAMPER AND PLENUM BEHIND LOUVER FOR CONNECTION OF 24 "X12" EXHAUST DUCTS FROM ABOVE. 3O EXTERIOR CONDENSING UNIT FOR LIEBERT ENVIROMENTAL UNIT. PROVIDE 4" THICK CONCRETE PAD BENEATH UNIT. a0 10 TON LIEBERT UNIT: PROVIDE SHEET METAL DISCHARGE PLENUM ON TOP UNIT, EXTENDED THROUGH CEILING FOR CONNECTION BY SUPPLY DUCTWORK AT EACH END. PROVIDE OPENING THROUGH WALL FOR TRANSFER OF RETURN AIR AS SPECIFIED IN PLAN NOTE #10. ROUTE REFRIGERANT AND 1" CONDENSATE PIPING UP THROUGH CEILING, THROUGH STRUCTURE, DOWN AND OUT EXTERIOR WALL. CONDENSATE PIPING SHALL SLOPE MINIMUM OF 1/4" PER FOOT TOWARDS EXTERIOR. UNIT MANUFACTURER SHALL SIZE REFRIGERANT PIPING. PROVIDE SECONDARY DRAIN PAN WITH 2" SIDES UNDERNEATH ENTIRE UNIT. REFER TO SHEET M501 FOR SPECIFICATIONS AND ELECTRICAL DRAWINGS FOR POWER CONNECTION. 5O TAP TOP OF DUCTWORK WITH SPIN —IN FITTING AND DAMPER. ROUTE FLEXIBLE DUCTWORK THROUGH STRUCTURE AND DOWN TO DIFFUSER. 6� PROVIDE TRANSFER DUCT, GRILLE, AND MOTORIZED DAMPER THROUGH CORRIDOR WALL. DAMPER SHALL BE INTERLOCKED WITH FM200 EXHAUST FAN TO OPEN DURING FAN OPERATION. REFER TO ELECTRICAL DRAWINGS FOR WIRING. O RELOCATE EXISTING VAV BOX WITH ELECTRIC REHEAT TO POSITION INDICATED. EXTEND EXISTING ELECTRICAL SERVICE FROM EXISTING LOCATION. PROVIDE JUNCTION BOX, SPLICES, CONDUIT, AND WIRE AS REQUIRED. 8O REMOVE EXISTING VAV BOX, DUCTWORK, ETC. AS INDICATED. REMOVE TEMPERATURE CONTROLS BACK TO SOURCE. 9Q ROUTE 6 7X6" EXHAUST DUCT DOWN IN CORNER OF ROOM TO BELOW RAISED FLOOR FOR EVACUATION OF FM200. BALANCE TO 125 CFM. PROVIDE ONE (1) PERFORATED FLOOR PANEL AT OPPOSITE END OF ROOM FOR TRANSFER OF AIR THROUGH AREA BELOW THE RAISED FLOOR. 10 PROVIDE TRANSFER DUCT, GRILLE, AND MOTORIZED DAMPER THROUGH BATTERY WALL. DAMPER SHALL BE INTERLOCKED WITH LIEBERT UNIT L -1 TO OPEN DURING UNIT OPERATION FOR RETURN AIR. REFER TO ELECTRICAL DRAWINGS FOR WIRING. (.�4 EQUIPMENT LIST L -1 LIEBERT ENVIROMENTAL UNIT M# UH 125, 208/60/3 CU -1 CONDENSING UNIT FOR L -1 M# DCDF LP, 208/60/3 EF -1 GREENHECK M# SQ -140 IN —LINE CABINET EXHAUST FAN, 1800 CFM ® 0.5" SP, 1/2 HP, PROVIDE WITH DISCONNECT. EF -2 GREENHECK M# SO-140 IN —LINE CABINET EXHAUST FAN, 1650 CFM ® 0.5" SP, 1/2 HP, PROVIDE WITH DISCONNECT. EG1 24 "X24" TITUS MODEL 50F, 1/2" ALUMINUM EGGCRATE RETURN GRILLE, FRAME FOR LAY —IN CEILING EG2 12 "X12" TITUS MODEL 50F, 1/2" ALUMINUM EGGCRATE RETURN GRILLE, PERIMETER FRAME FOR WALL MOUNTING. LD1 48" TITUS MODEL TBD -10 HIGH CAPACITY PLENUM SLOT DIFFUSERS, WITH (2) 1" SLOTS AND 8" OVAL INLET. " PD1 24"X24" TITUS MODEL TMSA, ALUMINUM 10 NECK SQUARE SUPPLY DIFFUSER. PD2 24 "X24" TITUS MODEL TMSA, ALUMINUM 8" NECK SQUARE SUPPLY DIFFUSER. =Archit Engineers& 9100 Keystone Crosse Suite 200 Indionopolis, Indiono 317.848.7800 FAX 317.574.0957 ��nd I�Irlm I►rd,ll.a Interior 00"rip Im D a W, Osseo "'" 0"m 4/3/95 F0 Z JQCL a: 8� J LL .J Q z W a Z w oil, icy �..�. •. �; go ceriw ay - N x:860 0 .Q I. STAT ::y01 lom /fill carom ®y BNset No. Of minim Fie N0. FM-